2. + 4. + 6. Actuator Plug-In



Similar documents
Online Help choise of topic

1 Overview / New Functionality Content of release CD V Language information User documentation... 4

Main document. User manual. English. General part

Belimo Gateway MP to Modbus RTU - UK24MOD

InTouch Example Description

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Functional Profile: Heat Pump with Temperature Control

PC Software for VAV compact and modular controllers

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring function

All of the above software and firmware are included in the VAV-B Package. Contact Customer Service or Technical Support for this, or for cables.

Installation Guide for Crossroads Software s Traffic Collision Database

UK-1. Product Information MP/LONWORKS UK24LON Gateway LONWORKS LONMARK. Actuators for heating, ventilation, climatisation UK24LON

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

INF-USB2 and SI-USB Quick Start Guide

Tracer Controls. Tracer VV550/551 VAV Controllers CNT-PRC003-EN. October 2005

HOW TO CREATE AN HTML5 JEOPARDY- STYLE GAME IN CAPTIVATE

Getting TechWizard Version 4 Started Using Excel 2007 or Higher

ServiceTools for MicroTech II Version 2.0 Applied Terminal Systems User Manual

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Quick Installation Guide Network Management Card

Device configurator DRC200

VAV system solution for non-pressure-dependent applications in enclosed spaces

<User s Guide> Plus Viewer. monitoring. Web

PHD User Manual. Table of Contents

Excel Smart I/O XFC 2AXX, XFC 3AXX, XFC 2DXX, AND XFC 3DXX MODULES

Aeroflex USB Control Center. Operation Manual. Aeroflex USB Control Center Software (P/N )

Operating and installation manual

INFO 1.0. Greater safety and comfort in air-conditioned buildings. Actuators for heating, ventilation, air-conditioning

How to install and use the File Sharing Outlook Plugin

ValveLink Mobile Software

OEM-EP Pressure Controllers

Electronic Control Devices The European Product Catalogue 2007

Mixing Valves. ARGUS Application Note: Mixing Valves

Keep SQL Service Running On Replica Member While Replicating Data In Realtime

DDNS Management System User Manual V1.0

DEPLOYING A VISUAL BASIC.NET APPLICATION

Important Notes for WinConnect Server ES Software Installation:

Licensed Functionality: Remote Monitoring

MSI Admin Tool User Guide

ME Week 11 Introduction to Dynamic Simulation

PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER W/LON/BACNET

Managing Contacts in Outlook

Option 1 Using the Undelete PushInstall Wizard.

Installation Guide. Research Computing Team V1.9 RESTRICTED

TAC Vista. TAC Vista. Technical Manual. TAC Pangaea WorkStation

Tournament Pairing Program Installation Instructions for Windows 7

Important Notes for WinConnect Server VS Software Installation:

EVAL-UFDC-1/UFDC-1M-16

WPA-LON Series WPA-LON-1. Application. Model Chart WPA-LON-2 WPA-LON-3. Adapter Card Software

Getting Started With SPSS

Entire Connection Version 4.2.1

PC - Program to Configure the Diagnostics Node of SmartRouter RTRSD and SmartRepeater RPTSD Software Description

How To Control A Pressura Room Pressure Monitor

maxymos PC Software 1. Installing and Starting the Program 2. Tabs and their Functions

1. Navigate to Control Panel and click on User Accounts and Family Safety. 2. Click on User Accounts

POS Connector Installation and Setup Guide

Introduction: The Xcode templates are not available in Cordova or above, so we'll use the previous version, for this recipe.

ScanWin Installation and Windows 7-64 bit operating system

Autodesk Fusion 360: Assemblies. Overview

Installing and Configuring Microsoft Dynamics Outlook Plugin to Use with ipipeline MS CRM

TECHNICAL NOTE TNOI32

Promap V4 ActiveX MSI File

System Overview and Terms

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

e-gate USB Smart Card Driver Install Notes (Windows 98/98SE/Me)

HP-1000 Powerline Ethernet Adapter

2. Installation Instructions - Windows (Download)

HP-1000 Powerline USB Adapter

SharePoint AD Information Sync Installation Instruction

BASLER ACE QUICK INSTALLATION GUIDE

OMEGA STUDIO SOFTWARE INSTALLATION GUIDE

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Loyalty Program Guide

Online Backup - Installation and Setup

Replacing a MealTime Point of Sale Computer

EC-gfxProgram

CREATING AN IMAGE FROM AUTOCAD CADD NOTE 16. MENU: AutoCAD, File, Plot COMMAND: plot ICON:

Working with Multiple Devices

Enhanced Reporting Software Monitor USER MANUAL

Publishing Geoprocessing Services Tutorial

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

TCMS V2 WITH OFIS SCANNER

Installing and Using No Machine to connect to the Redhawk Cluster. Mac version

Apple Mail Setup Guide (POP3)

TeamPoS2000-M Windows XP Pro Device Installation

Rev. 06 JAN Document Control User Guide: Using Outlook within Skandocs

Programmable Logic Controllers

VPN: Installing the IPSec client

Questions: Does it always take the same amount of force to lift a load? Where should you press to lift a load with the least amount of force?

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

Analytics for Tally.ERP 9

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero

Application & Quick-Start Guide

ARKEL Vision ARL-500 Uzaktan Erişim ve İzleme Sistemi ARL-500 Remote Control and Monitoring System KULLANICI KILAVUZU USER MANUAL TR/EN

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Transcription:

2. + 4. + 6. Actuator Plug-In Description / Documentation # Tools-007-E-1 nvivalue SNVT_xxx nvovalue SNVT_xxx LONWORKS LONWORKS MP-BUS Data communication / Tools / Kem / 07.01.02 1 / 10

Contents Page 1. General 3 2. Using the Actuator Plug-In 3 3. Accessing the Actuator Plug-In from function objects 3 3.1 Actuator Plug-In access with LON actuators 3.2 Actuator Plug-In access with MFT / MFT2 actuators 4. Installing under LonMaker 2.0 or 3.0 5 5. Starting the Actuator Plug-In 6. Function pages of the Actuator Plug-In 6 6.1 Four function pages for VAV-Compact NMV-D2M 6.2 Three function pages for MFT(2) and LON actuators 6.3 Function page: Install Actuator 6.3.1 Button: "Read Serial Number" 6.3.2 Button: "Add / Replace Actuator" 6.3.3 Button: "Remove Actuator" 6.4 Function page: Setpoint 6.5 Function page: Min / Max Setpoints 6.6 Function page: Graph (this page only appears for the NMV-D2M) Data communication / Tools / Kem / 07.01.02 2 / 10

Belimo Actuator Plug-In 1. General The Belimo Damper "Actuator Plug-In" is a plug-in device with an LNS capability based on LonMaker. Its purpose is to make the commissioning of Belimo busable actuators much easier. In addition, the Actuator Plug-In can also be very helpful for monitoring the operation of existing systems. 2. Using the Actuator Plug-In The "Actuator Plug-In" can be used with the following Belimo actuators: Actuators which can be connected directly to a LONWORKS network. MFT / MFT2 actuators which can be connected to a LONWORKS network through a UK24LON Gateway unit. Damper actuators AM24LON (US) GM24LON (US) AF24LON (US) LONWORKS LONWORKS Damper actuators NM24-MFT(2) AM24-MFT(2) GM24-MFT(2) LF24-MFT(2) AF24-MFT(2) Linear actuators for globe valves and SuperCompact control valves NV24LON NVF24LON NVF24LON-E NVS24LON AS24LON AVS24LON MP-BUS Linear actuators for globe valves and SuperCompact control valves NV24-MFT(2) NVF24-MFT(2) NVF24-MFT(2)-E AV24-MFT(2) NVS24-MFT(2) AVS-MFT(2) VAV-Compact NMV-D2M 3. Accessing the Actuator Plug-In from function objects 3.1 Actuator Plug-In access with LON actuators (actuators for direct connection to LonWorks) The function profiles Node Object #0 and Damper Actuator Object #8110 are implemented in the LON actuator node. The Actuator Plug-In accesses the actuator functions through the function object of Damper Actuator Object #8110. Damper Actuator Object #8110 nvirelstpt SNVT_lev_percent nviactuatstate SNVT_switch nvoactualvalue SNVT_lev_percent nvoabsangle SNVT_angle_deg nvimanovrd SNVT_hvac_overid Node Object #0 Configuration Properties SCPTminSendTime (52) SCPTmaxSendTime (49) SCPTmaxRcvTime (48) SCPTminDeltaAngl (43) nvirequest SNVT_obj_request nvostatus SNVT_obj_status nvofiledirectory SNVT_address SCPTactuatorType (41) SCPToemType (61) SCPTlocation (17) SCPTnomAngle (58) SCPTminSetpoint (53) SCPTmaxSetpoint (50) SCPTdriveTime (45) SCPTdirection (44) Data communication / Tools / Kem / 07.01.02 3 / 10

3.2 Actuator Plug-In access with MFT / MFT2 actuators The Node Object #0 is implemented once in a UK24LON unit and the Damper Actuator Object #8110 eight times (once for each of the actuators that can be connected to a UK24LON unit). In addition, the Open Loop Sensor Object #1 is also implemented eight times. This object allows sensor values to be transferred to a LonWorks network. The Actuator Plug-In accesses actuators 1...8 through the function object of the corresponding Damper Actuator Object #8110. The Sensor Plug-In accesses sensors 1...8 through the function object of the corresponding Open Loop Sensor Object #1 (a description will be found in separate documentation 2.+4.+6. Sensor Plug-In # Tools-008-E-1) Node Object #0 1x implemented nvirequest SNVT_obj_request Node Object #0 nvostatus SNVT_obj_status nvofiledirectory SNVT_address Configuration Properties SCPTdevMajVer (165) SCPTdevMinVer (166) SCPTobjMajVer (167) SCPTobjMinVer (168) Damper Actuator Object #8110 8x implemented Damper Actuator Object #8110 nvirelstpt SNVT_lev_percent nviactuatstate SNVT_switch nvoactualvalue SNVT_lev_percent nvoabsangle SNVT_angle_deg nvimanovrd SNVT_hvac_overid nvoabsairflow SNVT_flow Configuration Properties SCPTobjMajVer (167) SCPTobjMinVer (168) SCPTminSendTime (52) SCPTmaxSendTime (49) SCPTmaxRcvTime (48) SCPTminDeltaAngl (43) SCPTminDeltaFlow (47) SCPTactuatorType (41) SCPToemType (61) SCPTlocation (17) SCPTnomAngle (58) SCPTnomAirFlow (57) SCPTminSetpoint (53) SCPTmaxSetpoint (50) SCPTdriveTime (45) SCPTdirection (44) Open Loop Sensor Object #1 8x implemented Open Loop Sensor Object #1 nvosensorvalue SNVT_xxx Configuration Properties SCPTobjMajVer (167) SCPTobjMinVer (168) SCPTminSendTime (52) SCPTmaxSendTime (49) SCPTsndDelta (27) UCPTadFunction (1) UCPTadTranformation (2) SCPTtrnsTblX (28) SCPTtrnsTblY (29) Data communication / Tools / Kem / 07.01.02 4 / 10

4. Installing under LonMaker 2.0 or 3.0 1. Extract file DAPlugIn.zip (DAPlugIn.cab, setup.exe, setup.lst) to a temporary folder. 2. Double-click on file setup.exe which is now in the temporary folder. 3. Follow the instructions given by the Setup program. 4. Setup will suggest the link... \Programme\BELIMO LNS Actuator Plug-In\Damper Actuator. Accept the suggestion. 5. Copy the following files from the folder... \Programme\BELIMO - LNS Plug-in\Damper Actuator to folder \LonWorks\import mod_1_0a.xif mod_1_0a.xfb uk_1_1.xif uk_1_1.xfb uk_2_0.xif uk_2_0.xfb uk_3_0a.xif uk_3_0a.xfb Application uk_3_0a is suitable for 8-times UK24LON units (LonWorks linking of 8 MFT(2) actuators and 8 sensors) Application mod_1_0a is suitable for LON actuators (actuators incorporating a LON chip) 5. Starting the Actuator Plug-In Procedure: Select the required actuator object (as Fig.) Select "Configure (as Fig.) Actuator Plug-In will then start Data communication / Tools / Kem / 07.01.02 5 / 10

6. Function pages of the Actuator Plug-In 6.1 Four function pages for VAV-Compact NMV-D2M Click on the appropriate buttons to choose between 4 different function pages in the case of the NMV-D2M. 6.2 Three function pages for MFT(2) and LON actuators Click on the appropriate buttons to choose between 3 different function pages in the case of MFT / MFT2 / LON actuators. 6.3 Function page: Install Actuator This page allows actuators to be integrated into a Belimo MP-network, removed from an MP-network or identified. With LON actuators (actuators for direct connection to a LonWorks network) the page can also be used for simply reading out the Serial No. of the actuator. The buttons "Read Serial Number", "Add / Replace Actuator" and "Remove Actuator" are inoperative in the case of LON actuators. 6.3.1 Button: "Read Serial Number" Pressing this button asks the actuator to give you its Serial No. The number appears in the Serial No. field. Data communication / Tools / Kem / 07.01.02 6 / 10

6.3.2 Button: "Add / Replace Actuator" Pressing this button brings up a field for entering the Serial No. of an MFT / MFT2 actuator. There are two options for using this field: a) Add - A new, non MP-addressed actuator can be assigned to a specific function block of the UK24LON unit. When the appropriate Serial No. of the required actuator is entered here and the OK button is pressed the actuator will automatically receive the appropriate MP address through the assignment of the function block. For example, if the Actuator Plug-In has previously been started on function block 3 the actuator will automatically receive MP address 4. (Function block 0 = Actuator MP1, Function block 1 = Actuator MP2, Function block 2 = Actuator MP3, etc.) b) Replace - An existing, possibly defective, actuator can be replaced by a new one. Enter the Serial No. of the new actuator in the field and press the OK button. The existing MP address will then be automatically replaced by the address of the new actuator. When the Serial No. of an actuator that already exists in the network is entered it will automatically be assigned to the function block in which the Actuator Plug-In is active. At the same time the actuator receives the MP address corresponding to the function block. Position of Serial Nos. on actuators When MFT(2) actuators are delivered they carry a label bearing their individual Serial Nos. By means of this Serial No. an actuator can be assigned either a PP address or an MP1...MP8 address. An additional detachable label bearing the identical Serial No. is also attached to the actuator. When an actuator has been installed in a specific position in a system this additional label can be stuck on to the plan of the system in the same corresponding position. This provides a record of where the actuator with the corresponding Serial No. is installed in the building. Serial No. Serial No. on detachable label 6.3.3 Button: "Remove Actuator" Pressing this button de-addresses the actuator whose Serial No. is shown in the white field. In effect it isolates the actuator function block in LonMaker from the actuator. Data communication / Tools / Kem / 07.01.02 7 / 10

6.4 Function page: Setpoint A typical use of this page is for issuing, for test purposes when commissioning, an actuator with a specific setpoint (0...100%). The setpoint issued with the slide pointer acts on SNVT nvirelstpt (SNVT_lev_percent) of the function block. The effect of entering a 0...100% setpoint: Type Effect VAV-Compact NMV-D2M 0...100% nominal flow rate Damper actuators 0...100% angle of rotation Valve actuators 0...100% lift Note: When SNVT nvirelstpt is connected the setpoint that has been preset in the Actuator Plug-In only remains effective until the SNVT receives another setpoint from a different LON node. The procedure is explained by means of the following example: Move the slide pointer to the required position (38% in the example) Data communication / Tools / Kem / 07.01.02 8 / 10

The Feedback bar shows the appropriate value as soon as the "Apply" button is pressed. The actuator now receives the preset setpoint of 38%. When SNVT nvirelstpt is connected the setpoint will only remain valid until the SNVT receives another setpoint from a different LON node. 6.5 Function page: Min / Max Setpoints Depending on the type of actuator involved this page can be used for limiting the angle of rotation, the lift or the volumetric flow to a minimum or maximum. A minimum or maximum value can be defined using the slide pointers. Pressing the "Read Min/Max button causes the values preset in the actuator to be read out from the actuator, while pressing the Write Min/Max button causes them to be written into the actuator. Data communication / Tools / Kem / 07.01.02 9 / 10

The effect of entering Maximum Setpoint : Type VAV-Compact NMV-D2M Damper actuators Valve actuators Max. limit to... 0...100% nominal flow rate 0...100% angle of rotation 0...100% lift The effect of entering Minimum Setpoint : Type VAV-Compact NMV-D2M Damper actuators Valve actuators Min. limit to... 0...100% specified maximum setpoint 6.6 Function page: Graph (this page only appears for the NMV-D2M) For the NMV-D2M this page shows the actual volumetric flow rate in l/s as a function of time that is currently effective. The indicated value of volumetric flow corresponds to that output at SNVT_flow. The scaling of volumetric flow and time is carried out automatically by the Actuator Plug-In. This page is ideal for monitoring air volume control units. Data communication / Tools / Kem / 07.01.02 10 / 10