Excel Smart I/O XFC 2AXX, XFC 3AXX, XFC 2DXX, AND XFC 3DXX MODULES
|
|
|
- Elwin Simon
- 9 years ago
- Views:
Transcription
1 GENERAL Excel Smart I/O modules are LONMARK association-compliant devices, and can thus be used in all open LONWORKS environments. They feature a variety of software-configurable digital and analog inputs and outputs and are suitable for installation at strategic locations throughout your buildings. The modules convert physical input signals from sensors into network variables and the network variables into physical output signals for operating actuators. The diverse mix of inputs and outputs (flexibly configurable using Honeywell's LonMaker for Windows plug-in) makes the Excel Smart I/O ideally suited for a wide range of intelligent, distributed applications. Table 1 provides a brief overview of the available versions. See Table 4 on page 7 for details. Excel Smart I/O XFC 2AXX, XFC 3AXX, XFC 2DXX, AND XFC 3DXX MODULES PRODUCT DATA FEATURES LONMARK association-compliant, thus suitable for all open LONWORKS networks Flexible, software-configurable inputs/outputs Flash memory for downloading applications (thus increasing flexibility and facilitating future upgrading) 2-wire FTT-10A LONWORKS bus interface Easily-accessible service button and a service LED Four fast digital inputs configurable for static input or totalizing (at up to 20 Hz) Four relays to which (after software-configuration) e.g. floating actuators can be directly connected Two or (depending upon model) four universal inputs, each with an extra terminal for powering 24 Vac sensors, supporting (depending upon model) different sensor types, also configurable for voltage-variable input or slow digital input Two analog outputs, each with an extra terminal for powering 24 Vac actuators, supporting (depending upon model) voltage-variable or current-variable output Greater reliability, fewer cables (thus reducing fire burden), lower installation costs, easy start-up and servicing, digital communication DIN rail (ring cabinet / fuse box) mounting and wallmounting supported Easy wiring check using the XILON Handheld MMI Fixed or removable terminals (depending upon model) 230 Vac or 24 Vac power supply (depending upon model) Optional six three-position, software-configurable manual overrides and corresponding feedback Optional terminal protection covers for wall mounting Optional swivel label holders for wiring information Table 1. Brief Overview of Excel Smart I/O Versions Version Description Power Overrides UIs DIs AOs relays XFC2A Vac no XFC2A Vac no XFC3A Vac no XFC3A Vac no XFC3A Vac no XFC2D Vac yes XFC2D Vac yes XFC3D Vac yes XFC3D Vac yes XFC3D Vac yes U.S. Registered Trademark Copyright 2002 Honeywell Inc. All Rights Reserved EN0B-0311GE51 R
2 DESCRIPTION With the Excel Smart I/O, you can choose from among ten variants featuring different assortments of universal inputs, digital inputs, analog outputs, and relays for use in conjunction with a wide range of sensor types and actuators. All module inputs and outputs are protected against overvoltages of max. 40 Vdc and 24 Vac. An extra power output terminal accompanying each analog input/output can also be used to power 24 Vac field devices. Further, the individual inputs and outputs can be flexibly configured using Honeywell's LonMaker for Windows software plug-in. Thus, each of the four fast digital inputs can be configured for static input from dry contacts or open collectors or for totalizing signals having a frequency of up to 20 Hz, while the universal inputs can be configured for analog signals from specific sensor types (depending upon model), or for voltage-variable input, or for slow digital input (max. frequency = 0.25 Hz). The XFC 2D05 and 2D06 as well as the XFC 3D04, 3D05, and 3D06 are equipped with six 3-position manual override switches. Using Honeywell's software plug-in, these switches can be configured to override the individual relays or analog outputs. These modules also feature ten status LEDs showing the condition of the inputs/outputs allocated to them. The XFC 2A05 and 2A06 as well as the XFC 2D05 and 2D06 (long housing) are equipped with a transformer enabling them to be powered with 230 Vac (+10%/-15%); standby power consumption (= all outputs are inactive, all inputs are open, and all LEDs excepting the power LED are off) is less than 10 VA. All other models (short housings) require 24 Vac (±20%); in this case, standby power consumption is less than 5 VA. All modules are equipped with a power LED as well as with a LONWORKS service button and corresponding service LED. Matching terminal protection covers and swivel label holders are available for all modules. four LONMARK open-loop sensor objects (Obj#5-8) (one for each digital input), two LONMARK open-loop actuator objects (Obj#9-10) (one for each analog output), and four LONMARK open-loop actuator objects (Obj#11-14) (one for each relay). LONMARK Node Object The LONMARK node object allows the various different objects in a node to be monitored. Upon receiving an update to nvirequest, nvostatus is updated. The definition of SNVT_obj_request includes an object ID field to allow the node object to report status conditions for all objects in a node. The node self-documentation string lists the names of the individual LONMARK objects, allowing a network management node or tool to display useful information about an Excel Smart I/O; it also states (in the optional part after the semicolon) that the node is an Excel Smart I/O, and lists its version number. Example: network input sd_string("@x y") SNVT_xxx nvname; where input can be replaced by output, x refers to the object x listed within set_node_sd_string, and y is the NV index within the following LONMARK object definition: set_node_sd_string "&"&3.2@0,1[4AI,1[4DI,3[2AO,3[4DO;SmartIO_01" nvirequest SNVT_obj_request Node Object (LonMark object type no. 0) mandatory Network Variables nvostatus SNVT_obj_status INTEROPERABILITY The Excel Smart I/O is compliant with LONMARK Application Layer Guidelines V3.2. and thus interoperable with all other devices in open LONWORKS networks (including third-party devices). See also section "LonWorks Network Interface." optional Network Variables nvofiledirectory SNVT_address nvohwtype UNVT_HWType Excel Smart I/O Module Response Times The response time is defined as the interval between the updating of the physical signal and the updating of the corresponding NV (or vice versa). Response times vary somewhat due to various factors. Assuming that only a single digital input changes at any given time, the corresponding response times will typically amount to approx. 1 second. Thus, depending upon your specific circumstances, the Excel Smart I/O may be suitable for rapid-response applications. LONMARK Objects The Excel Smart I/O features a total of 15 LONMARK objects: one LONMARK node object (Obj#0) to allow monitoring and setting the status of the various sensor / actuator objects, four LONMARK open-loop sensor objects (Obj#1-4) (one for each universal input), SCPTmaxSendTime SNVT_time_sec SCPTmaxRcvTime SNVT_time_sec UCPT_Poll UCPT_Version optional configuration properties nvohwidentify UNVT_HWIdentify Fig. 1. Profile of LONMARK Node Object EN0B-0311GE51 R0802 2
3 Table 2. Node Object network variables NV Name Type Description RQ_NORMAL returns the object to the enabled, non-overridden state. RQ_DISABLED disables the object. RQ_ENABLE enables the object. RQ_UPDATE_STATUS posts the current settings of the flags of the specified object. RQ_REPORT_MASK reports the supported flags of the specified object. RQ_RESET resets the appropriate LONMARK object: If the digital input object is configured for totalizing, it resets the totalizer to (0xFFFF); if associated to the node object, it resets the node. RQ_CLEAR_RESET requests that reset_complete be cleared. All other requests read to an "invalid_request" error. object_id is the ID of the object within the node. For invalid_id, a value of "1" means that the requested object ID is not implemented in this node. For invalid_request, a value of "1" means that unimplemented function has been requested. For disabled, a value of "1" means that the object has been disabled: those I/O objects not supported by the current hardware type will always be disabled. For open_circuit, a value of "1" means that an open circuit has been detected. For unable_to_measure, a value of "1" means that an I/O line has failed. For comm_failure, a value of "1" means that network communications have failed: one or more bound input NVs specified for receive heartbeat weren't updated within the configured receive heartbeat time. For manual_control, a value of "1" means that the actuator is under local control: this field applies to the output objects and the node object, only, and notifies whether the appropriate output was manually overridden. Not supported. For in_override, a value of "1" means that the module has been overridden via nviaomanovrd or nvidomanovrd (e.g. using the XILON Handheld MMI) For report_mask, a value of "1" means that the status is an event mask. Not supported. For reset_complete, a value of "1" indicates the execution of the reset sequence. After a reset sequence, the reset flag goes to TRUE (1) and remains in this state until it is cleared (acknowledged). Valid range: Any value within user data memory of Neuron Chip. Points to a file directory nvofiledirectory SNVT_address in the address space of the Neuron Chip. Used to access the configuration properties accessed by network management read/write messages. Set at factory; stored in coprocessor's EEPROM. Represents the hardware type with nvohwtype UNVT_HWType respect to its OS number (e.g. XFC 3A01 001) and the coprocessor's software version. The hardware type is passed through the LONWORKS network as a polled output NV. Typically polled for diagnostic purposes. Set at factory; stored in coprocessor's EEPROM. Used to identify the hardware by the nvohwidentify UNVT_HWIdentify number and types of I/Os supported by the actual hardware type. This information is passed through the LONWORKS network as a polled output NV. Typically polled for diagnostic purposes. Valid range: s; in increments of 1 s (default = 60.0 s). Defines the maximum SCPTmaxSendTime SNVT_time_sec period of time before output NVs are automatically updated. Defines the Maximum Send Time and is accessible using standard LONMARK mechanisms. Valid range: s (default = 0). Defines the max. time that elapses after the last SCPTmaxRcvTime SNVT_time_sec update to a bound input NV. Defines the Maximum Received Time and is accessible using standard LONMARK mechanisms. Setting to zero disables the receive failure detect mechanism. Valid range: Pre-set at factory. Configures the start-up behavior for input NVs with respect to getting an immediate update through a poll request. If enabled, any input NV UCPT_Poll bound to another node will initiate a poll request after reset, thus helping to avoid start-up problems until the next NV update. Polling based on a time grid of 1 second, only. If disabled, the input NVs remain invalid until the next update is sent. UCPT_Version Valid range: Pre-set by application program. Identifies the current application and its version. Passed through the LONWORKS network as a read-only file. Readable using standard LONMARK mechanisms. nvirequest nvostatus SNVT_obj_request SNVT_obj_status 3 EN0B-0311GE51 R0802
4 LONMARK Sensor/Actuator Objects All actuator objects have an output NV showing the actual state of the physical output and whether it is in the automatic or manual override mode. All sensor objects have a common configuration property defining the heartbeat time. LONMARK Open-Loop Actuator Objects for Analog Outputs The Excel Smart I/O makes use of two LONMARK open-loop actuator objects (one for each analog output). LONMARK Open-Loop Sensor Objects for Universal Inputs The Excel Smart I/O makes use of four LONMARK open-loop sensor objects (one for each universal input) suitable for use in applications in which the actuator provides no feedback. Open-Loop Actuator Object (LonMark object type no. 3) mandatory Network Variables optional Network Variables SCPTdirection[x] SNVT_state UCPT_AOType[x] optional configuration properties Fig. 4. Profile of LONMARK actuator objects for AOs Fig. 2. Profile of LONMARK sensor object for UIs LONMARK Open-Loop Actuator Objects for Relays The Excel Smart I/O makes use of four LONMARK open-loop actuator objects (one for each relay) individually configurable as simple ON/OFF controls or as floating outputs (in order to drive two physical outputs with configurable runtimes). LONMARK Open-Loop Sensor Objects for Digital Inputs The Excel Smart I/O makes use of four LONMARK open-loop sensor objects (one for each digital input). Fig. 3. Profile of LONMARK sensor objects for DIs Figure 5. Profile of LONMARK actuator objects for relays EN0B-0311GE51 R0802 4
5 NV Name Type Description Table 3. LONMARK sensor/actuator object NVs nvoaivaluepct SNVT_lev_percent Transmitted immediately when its value has changed by a rate higher than the configured "Send on Delta". Regularly transmitted as a heartbeat output. nvoaitemp SNVT_temp_p Transmitted immediately when its value has changed by a rate higher than the configured "Send on Delta". Regularly transmitted as a heartbeat output. nvoaiswitch SNVT_switch Transmitted immediately when its value has changed. Regularly transmitted as a heartbeat output. UCPT_AIType not applicable Used to define the appropriate input type. Stored in the configuration parameter file accessible using standard LonMark mechanisms. Used by the NEC coprocessor. UPCT_AISendDelta not applicable Defines the significant change rate of the associated input which should cause an immediate NV update to be sent. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. Applies to the universal input type when configured for "Voltage" or "Temperature Sensor", respectively, and will be ignored for other input types. UCPT_AIProperty not applicable Used to define some properties associated to the analog input. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used by the NEC coprocessor. nvodiswitch SNVT_switch Represents a slow digital input connected to the digital input terminals. According to its configuration with respect to a normally open / normally closed contact, the output NV shows "state=0 / value=0%" for the "disabled" logical state, and "state=1 / value=100%" for the "enabled" logical state. nvodicount SNVT_count Transmitted immediately when its value has changed more counts than defined in "Send on Delta". Regularly transmitted as a heartbeat output. After power-up and reset, the value 0xFFFF=65535 will be sent to the network to indicate to the receiving device that previous count values have been lost due to a reset. nvodioccupancy SNVT_occupancy Transmitted immediately when the digital input state has changed. Regularly transmitted as a heartbeat output as dictated by ncisndhrtbt. UCPT_DIType not applicable Used to set up the type of DI. It is stored in the configuration parameter file accessible using standard LONMARK mechanisms. UCPT_DIProperty not applicable Used to define the properties associated with a digital input. nvoaoactposnfb SNVT_switch Represents the current status of the analog output, including feedback related to manual override initiated from either nviaomanovrd or the manual override switches. Typically used for monitoring purposes at supervisory stations or for diagnostic purposes. In the case of an override, the state is equal to -1. nviaoswitch SNVT_switch Used to drive the analog output to %. Typically bound to a LONWORKS control device issuing an output level %. A value of 110% is also possible (corresponding to a voltage range of V). nviaovaluepct SNVT_lev_percent Used to drive the AO to %. Typically bound to a LONWORKS control device issuing an output level %. A value of 110% is also possible (corresponding to a voltage range of V). nviaomanovrd SNVT_switch Used to manually override the analog output to %. Has priority over nviaoswitch and nviaovaluepct. Typically used during start-up and commissioning, supported by the XILON Handheld MMI, and does not have to be bound. If the relay is at present manually overridden, this will be reflected in nvoaoactposnfb, accordingly. The manual override remains in force until explicitly reset to normal operation via power-up and reset. This state is therefore stored in EEPROM. If there has been a manual override to the same output, this will have priority over nviaomanovrd. SCPTdirection SNVT_state Used to set the actuator sense of rotation and the safety position in case of any failure. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. UCPT_AOType not applicable Used to set up the various properties associated with an analog output point. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. 5 EN0B-0311GE51 R0802
6 nvodoactposnfb SNVT_switch Represents the current status of the relay, including feedback related to manual override initiated from either nvidomanovrd or the manual override switches. Typically used for monitoring purposes at a supervisory station or for diagnostic purposes. In the case of floating actuator, nvodoactposnfb will monitor the actual valve position based on the calculation of the position within the motor model. In the case of an override, the state is equal to -1. nvidoswitch SNVT_switch Used to drive the relay, which can be configured for different models, such as simple ON/OFF output, or floating output. Typically bound to a LONWORKS control device issuing an output level ON/OFF or %, as the case may be. nvidovaluepct SNVT_lev_percent Used to drive the relay to % when configured for floating type. Typically bound to a LONWORKS control device issuing an output level %. If both nvidoswitch and nvidovaluepct receive valid values, nvidovaluepct will have priority. nvidomanovrd SNVT_switch Used to manually override the relay to ON/OFF. Has priority over nvidoswitch and nvidovaluepct. Typically used during start-up and commissioning, supported by the XILON Handheld MMI, and does not have to be bound. If the relay is at present manually overridden, this will be reflected in nvodoactposnfb, accordingly. The manual override remains in force until explicitly reset to normal operation via power-up and reset. This state is therefore stored in EEPROM. If there has been a manual override to the same output, this will have priority over nvidomanovrd. UCPT_DOType not applicable Used to set-up the type of the relay point. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used by the NEC coprocessor. UCPT_DOProperty not applicable Used to set-up the various properties of a relay. Depending upon the selected output type, various different properties can be set-up which are stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used by the NEC coprocessor. UCPT_StatusLED not applicable Used to set-up the various properties associated with a status LEDs. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used by the NEC coprocessor. UCPT_ManOvrdSw not applicable Used to set-up the manual override switches accordingly. Stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used by the NEC coprocessor. TECHNICAL DATA General The Excel Smart I/O is equipped with a 10-MHz 3150 Neuron Chip (which executes the application program and implements the LonTalk protocol) and a NEC coprocessor (for handling the inputs and outputs). It communicates within the LONWORKS network at a rate of 78 kilobaud via an FTT-10A Free Topology Twisted Pair Transceiver Each module is equipped with four 230 Vac, 6 A digital outputs, i.e. relays (including two normally open [N.O.] and two changeover [C.O.] relays). Floating actuators can be directly connected to these relays once they have been configured using Honeywell's LonMaker for Windows plugin. Further, each Excel Smart I/O is equipped with four fast digital inputs. Each fast digital input can be reconfigured (using the Honeywell plug-in) to accept static input (from dry contacts or open collectors) or to totalize input signals (having a frequency of up to 20 Hz). Depending upon the given model, each module is also equipped with a varying number of different universal inputs and analog outputs (see section "Universal Inputs and Analog Outputs" below), each of which has an extra power output terminal for supplying 24 Vac power to field devices. Certain models also feature six 3-position manual override switches and ten status LEDs (see section "Manual Overrides and Status LEDs" below). Optional accessories include swivel label holders and terminal protection covers (see "Optional Accessories" below). A power LED, a LONWORKS service LED, and a corresponding LONWORKS service button (see sections "LONWORKS Service LED" and "LONWORKS Service Button" below) are located on the top of each module. There are two standard module sizes: the long module (with a built-in 230 Vac transformer) and the short module (which requires 24 Vac power). See section "Long and Short Housings" below. Universal Inputs and Analog Outputs Further, depending upon the given model, the modules are equipped with a variable number of different universal inputs and analog outputs. Universal Inputs The term "universal inputs" refers to analog inputs for temperature-sensor signals which can also be reconfigured (using the Honeywell plug-in) as voltage-variable or slow digital inputs (e.g. for dry-contact/open-collector signals). EN0B-0311GE51 R0802 6
7 Each module is equipped with universal inputs of one of the following three types: The first type can be configured for analog signals from NTC20k sensors or for Vdc/2..10 Vdc voltage signals or for slow digital input (max. frequency = 0.25 Hz). The second type can be configured for analog signals from three-wire PT100 sensors or for Vdc/2..10 Vdc voltage signals or for slow digital input (max. frequency = 0.25 Hz). The XFC 3A04001 and XFC 3D04001 are equipped with two universal inputs of this type, the reconfiguration of which yields four voltage-variable or slow digital inputs. The third type can be configured for analog signals from PT1000, Ni1000, and Ni1000TK5000 sensors or for Vdc/2..10 Vdc voltage signals or for slow digital input (max. frequency = 0.25 Hz). Each universal input features an extra power output terminal for supplying 24 Vac power to active sensors. Analog Outputs Each module is equipped with two analog outputs providing either V, 1 ma signals or ma/4..20 ma signals (depending upon model). Each analog output features an extra power output terminal for supplying 24 Vac power to actuators. Other Module-Specific Features / Options Manual Overrides and Status LEDs The XFC 2D05 and 2D06 as well as the XFC 3D04, 3D05, and 3D06 are each equipped with six 3-position (ON, OFF, AUTO) manual override sliding switches with which the individual digital/analog output signals can be overridden. The manual override switches can be configured using Honeywell's plug-in. These same modules are each equipped with a total of ten colored status LEDs: The four 3-color software-configurable LEDs can be used to test whether signals from e.g. digital inputs are changing. They can also indicate whether the hardware is defective. The four yellow software-configurable LEDs are ordinarily used for relays. The two red variable-intensity LEDs are connected to the analog outputs; their brightness varies according to the strength of the corresponding signal (i.e. 0 volts / 0 ma = dark LED, 10 volts / 20 ma = bright LED) See also the section of the plug-in's on-line help on status LED configuration. Long and Short Housings The XFC 2A05 and 2A06 as well as the XFC 2D05 and 2D06 are each equipped with a transformer enabling them to be powered with 230 Vac, and they thus feature long housings (W x L x H = 180 x 76 x 110 mm). All other models require a 24 Vac power supply and are enclosed in short housings (W x L x H = 126 x 76x 110 mm). Optional Accessories Optional accessories include matching terminal protection covers (available in packs of 8) and swivel label holders (available in packs of 8). Those Excel Smart I/O modules featuring override switches require swivel label holders onto which the labels containing customer-specific wiring information can be applied. The swivel label holders are snapped into place on the housing. Table 4. Detailed Overview of Excel Smart I/O Versions XFC2A05 XFC2A06 XFC3A04 XFC3A05 XFC3A06 XFC2D05 XFC2D06 XFC3D04 XFC3D05 XFC3D06 housing long long short short short long long short short short power supply 230 Vac 230 Vac 24 Vac 24 Vac 24 Vac 230 Vac 230 Vac 24 Vac 24 Vac 24 Vac screw terminals fixed fixed fixed fixed fixed removable removable removable removable removable man. overrides none none none none none six six six six six status LEDs ten ten ten ten ten PT1000* two two two two UIs NTC20k four four four four PT100 two** two** fast DIs four four four four four four four four four four AOs V two two two two two two two two ma two two N.O. / C.O. relays two / two two / two two / two two / two two / two two / two two / two two / two two / two two / two *or Ni1000 or Ni1000TK5000 **or four analog inputs (if configured for voltage-variable or slow digital input instead of for input from three-wire PT100 sensors) 7 EN0B-0311GE51 R0802
8 LONWORKS Network Interface The Excel Smart I/O communicates within the LONWORKS network at a rate of 78 kilobaud via an FTT-10A Free Topology Twisted Pair Transceiver. This transceiver provides transformer isolation so that the bus wiring does not have a polarity. Devices equipped with this transceiver can be wired in daisy chain, star, loop, or any combination thereof as long as the max. wire length requirements are met. The recommended configuration is a daisy chain with two termination modules. This layout allows for maximum bus length, and its simple structure presents the least number of possible problems, particularly when adding on to an existing bus. For more information, please refer to Configuration and Binding The network variables of the Excel Smart I/O are configured and bound using Honeywell's LonMaker for Windows plug-in. Wiring Check The XILON Handheld MMI is used to check the wiring of the modules. See also Excel Smart I/O Installation Instructions (EN1B- 0180GE51) for more-detailed information. LONWORKS Service LED All models feature a LONWORKS service LED connected to the Neuron Chip service LED output. The service LED displays numerous different behaviors indicating various module states for use in troubleshooting. See also Excel Smart I/O Installation Instructions (EN1B- 0180GE51) for a complete description of these behaviors. For more information on standard service LED behavior, refer to Motorola LONWORKS Technology Device Data Manual, page AL-190. Accessories, Standards, Ratings, and Literature Accessories Swivel label holders; short and long variants (required for modules equipped with manual override switches). 24 Vac models, order number: XAL_LAB_S 230 Vac models, order number: XAL_LAB_L B Termination Module (one or two required, depending on LONWORKS bus layout; see Excel 500 Installation Instructions, EN1R-1047 for details). Terminal protection covers; short and long variants (required for wall/ceiling mounting). 24 Vac models, order number: XAL_COV_S 230 Vac models, order number: XAL_COV_L Approvals and Standards CE and EN LONMARK Application Layer Guidelines Version 3.2 Housings IP20 or IP30 (standard housing) No knowledge of LONWORKS is necessary to use XILON. Refer also to XILON Handheld MMI for LONWORKS Networks User Guide (EN2B-0214GE51) for more information. LONWORKS Service Button All models feature a LONWORKS service button accessible from the outside on the top of module for use in installation and troubleshooting. When the service button is pressed, the following actions take place: The service pin message is issued on the network. When the service button has been pressed longer than 30 seconds, the node reverts to normal mode. The service pin message is broadcast: whenever the service button has been pressed; after each reset due to power-up, software reset; when changing the mode from offline to online. Environmental Ratings Operating temperature: F ( C) Shipping/storage temperature: F ( C) Relative humidity (operation and storage): %, noncondensing Applicable Literature XILON Handheld MMI for LONWORKS Networks User Guide (EN2B-0214GE51) Excel Smart I/O Installation Instructions (EN1B- 0180GE51) Excel 50/500 LONWORKS Mechanisms (EN0B- 0270GE51) Excel 10 FTT/LPT B Termination Module Installation Instructions, form Honeywell's Excel Smart plug-in help file EN0B-0311GE51 R0802 8
9 DIMENSIONS 9 EN0B-0311GE51 R0802
10 By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Control Products Control Products Control Products Honeywell Inc. Honeywell Limited-Honeywell Limitee Honeywell AG Honeywell Plaza 155 Gordon Baker Road Böblinger Straβe 17 Manufacturing P.O. Box 524 North York, Ontario D Schönaich location certified to Minneapolis, MN M2H 3N7 Germany USA Canada EN0B-0311GE51 R0802 printed in Germany Subject to change without notice
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Functional Profile: Heat Pump with Temperature Control
Heat Pump with Temperature Control: 8051 LONMARK Functional Profile: Heat Pump with Temperature Control LONMARK Functional Profile: Heat Pump with Temperature Control 1 8051-10 1996, LONMARK Interoperability
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
Programmable Logic Controllers
Performance & Features con t Digital/Analog Inputs Each Smart is equipped with 8 digital inputs for you to utilize in your applications. On selected models such as FL1D-H12RCE, FL1D-B12RCE and FL1D-H12SND,
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
2. + 4. + 6. Actuator Plug-In
2. + 4. + 6. Actuator Plug-In Description / Documentation # Tools-007-E-1 nvivalue SNVT_xxx nvovalue SNVT_xxx LONWORKS LONWORKS MP-BUS Data communication / Tools / Kem / 07.01.02 1 / 10 Contents Page 1.
Excel 100/500/600 CONTROLLERS HONEYWELL EXCEL 5000 OPEN SYSTEM SYSTEM OVERVIEW. Copyright 2011 Honeywell Inc. All Rights Reserved
Excel 100/500/600 CONTROLLERS HONEYWELL EXCEL 5000 OPEN SYSTEM SYSTEM OVERVIEW Copyright 2011 Honeywell Inc. All Rights Reserved EN0B-0091GE51 R0611 EXCEL 100/500/600 SYSTEM OVERVIEW EBI/SymmetrE REPORT
INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS
VMC A4 INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS PRODUCT DATA SHEET FEATURES RF to 0-10 VDC out, analogue or PWM Maximal 3 digital inputs to RF RF communication with other equipment Wireless
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
SmartRouters Optionally with Bus Diagnostics RTRS RTRSD
SmartRouters Optionally with Bus Diagnostics RTRS RTRSD Data Sheet The present instruction is intended to support you concerning installation and use of the device. The information has been composed with
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL
N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
HCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
IntesisBox ASCII Server - LON
IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi
LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10
LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows
Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power
July 2010 PACSystems* RX3i Non-Isolated Analog Output Module with HART Communications, IC695ALG728 Non-Isolated Analog Output Modules, IC695ALG704, IC695ALG708 MODULE OK FIELD STATUS TB IC695ALG708 Q1
Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01
Introduction The requirements relating to driving safety, driving comfort, exhaust emissions and fuel economy are are becoming ever more stringent. This entails more intensive information exchange between
UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation
UPS PIco Uninterruptible Power Supply with Peripherals and I 2 C control Interface to be used with Raspberry Pi B+, A+, B, and A HAT Compliant Raspberry Pi is a trademark of the Raspberry Pi Foundation
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
Smile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
THE INPUT/OUTPUT SYSTEM. Key Points
M O D U L E T W O THE 2 INPUT/OUTPUT SYSTEM Key Points In the first module, you learned about the basic architecture and operation of the Allen-Bradley Micrologix 1000, including a brief introduction to
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
Y7230A CO 2 Alarm System
Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
InTouch Example Description
InTouch Example Description This document describes how to work with the InTouch example. It contains the following sections: Using the LNS DDE Server Examples 2 Using the Example LNS Database 2 Sequence
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
Operating and installation manual
Operating and installation manual Functional module LON-WA1/FT3 For the monitoring and control of fire dampers and smoke control dampers with an electric actuator Operating manual LON-WA1/FT3 / Technical
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
MNL-10Rxx Series MNL-15Rxx Series MNL-20Rxx Series
MNL-10Rxx Series MNL-15Rxx Series MNL-20Rxx Series TAC I/A Series MicroNet MN 100, MN 150, and MN 200 Controllers Installation Instructions Application The TAC I/A Series MicroNet MNL-10Rxx, MNL- 15Rxx,
Programming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
M-series FOUNDATION Fieldbus I/O
April 2013 Page 1 M-series FOUNDATION Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system Increases input/output Takes advantage of all smart device
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
DMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
ABB i-bus KNX IP Router IPR/S 2.1
Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.
SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01 Safety Guidelines
Powerline 1200 User Manual
User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product.you can visit www.netgear.com/support to register
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
Operating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Technical Information
Technical Information Interface with DDC 6 720 642 841-00.1RS Logamatic LON-Gateway For heating contractors during project planning 6 720 643 554 (11/2010) US/CA Contents Contents 1 Explanation of symbols
EXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy