Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay



Similar documents
Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

How To Test For Contamination In Large Volume Water

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Introduction. Methods. Sample Processing

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Oasis HLB Cartridges and 96-Well Plates

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Opiates in Urine by SAMHSA GC/MS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

LC-MS/MS for Chromatographers

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Multifunctional Autosampler AOC-6000 C146-E272A

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

CORESTA RECOMMENDED METHOD N 72

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

DETERMINATION OF PERFLUOROCHEMICALS IN RIVER WATER AND OTHER MATRICES BY AN AUTOMATED ON-LINE SPE UHPLC-MS/MS METHOD

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Supplementary Materials and Methods (Metabolomics analysis)

S olid Ph ase Extraction (SP E) Method:

Ádám Tölgyesi Joerg Stroka. Report EUR EN

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Overview. Purpose. Methods. Results

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

How To Develop A Recipe Card

LC-MS/MS, the new reference method for mycotoxin analysis

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

A commitment to quality and continuous improvement

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Appendix 5 Overview of requirements in English

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Waters Core Chromatography Training (2 Days)

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

Transcription:

PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird 1 Shimadzu, Manchester, UK The Food and Environment Agency, York, UK

Introduction The use of natural and synthetic hormones to increase the weight of meat producing animals is prohibited in the European Union (European Council Directive 96//EC and amended by Directive 003/74/EC) to protect consumers from the harmful effects of digesting hormone residues and their metabolites. Compliance with this legislation is monitored by the screening of a large number of animals every year. Urine is collected from animals on farms and liver from animals at abattoirs. Typically, sample preparation of these urine samples involves time-consuming two-step offline-spe. Here, we have developed an online-spe method to considerably shorten the pre-treatment time. In addition to optimisation of the extraction method, chromatographic separation was optimised to decrease ion-suppression and isobaric interference. Compound ionisation was enhanced using a new heated ESI (HESI) source on the LCMS-8050 triple quadrupole mass spectrometer. Materials and Methods Sample preparation Bovine urine samples were centrifuged at 10,000 rpm for 10 minutes. The supernatant (100µL) was spiked at 0, 0.5, 0.5, 1, 1.5,, 4 and 6 pg/µl with each target compound. The sample was diluted with 58 µl water (containing internal standards), 40 µl 50mM ammonium acetate buffer and µl β-glucoronidase solution. This mixture was left at approximately 37ºC for 6 hours. This mixture was diluted with 100 µl mobile phase A and centrifuged at 10,000 rpm. The supernatant was filtered through a 0. µm filter into the auto-sampler vial. LC-MS/MS analysis A Nexera UHPLC system was used for analysis of compounds combined with a LCMS-8050 triple quadrupole mass spectrometer (Shimadzu, Kyoto). A 6 port, position switching valve was utilised to accomplish the trapping and back-flushing of the first analytical column. A flow rate of 0.4 ml/min was utilised in pumps A, B and C and the oven temperature was set at 40ºC. The UHPLC configuration is shown in Figure 1. The LC-MS/MS was operated in MRM mode using both ESI positive and negative. Source conditions were optimised: nebulising gas flow, 3 L/min; heating gas flow, 5 L/min; drying gas flow, 10 L/min; interface temperature, 400ºC; DL temperature, 150ºC, heat block temperature 300ºC. Table 1 MRM acquisition parameters Compound Ion mode RT MRM Q1 Pre Bias (V) CE Q3 Pre Bias (V) methyltestosterone 10.6 303.1 > 97.05, 109.1-1 -6, -8-19, - β-boldenone 9.1 87.1 > 11, 135.1-3, -16-13, -6 α-boldenone 10.1 87.1 > 11.05, 69. -4, -1-13, -30 α-trenbolone 9. 71.1 > 53.15, 199.1-19, -4-18, -1 Progesterone 11.9 315.3 > 97.05, 109.05 - -3, -6-19, -1 Testosterone 10.0 89.1 > 97.05, 109.1-5, -6-18, -1 Hydroxystanozolol 10.3 345.3 > 81.1, 95.0-17 -51, -44-15, -19 Dienestrol ESI- 10.6 65.1 > 93.1, 49. 19 30, 6 16, 6 Hydroxystanozolol d 3 10. 348.3 > 81.1-17 -51-15 β-boldenone d 3 9.1 90.1 > 11.0-3 -13

LCMS-8050 Triple-quadrupole MS Chromolith Fast Gradient RP-18e 50-mm A Water with 0.mM ammonium fluoride B Methanol with 0.mM ammonium fluoride Waste EXP Trap Cartridge, 1mm x 5mm, HALO C8 C Water: methanol 90:10 with 0.mM ammonium fluoride Figure 1 Online-SPE-LC-MS/MS configuration Results and discussion Method development A heated ESI source was utilised for the effective ionisation of all target compounds using positive and negative mode. Four MRM transitions were optimised for each compound using an automated MRM optimization program within the LabSolutions workstation. Table 1 lists the quantifier and one qualifier transition. A Chromolith Fast Gradient RP-18e (50 x mm) column was utilised for target compound separation. This column was utilised in order to minimise the system back pressure that can often be high as a result of back-flushing the trapping column. This monolithic column was found to provide near identical results to a Kinetex C18 (50 x.1,.6µm ), but with a back pressure of only approximately 50 bar, in comparison to the Kinetex of approximately 400 bar. Various mobile phases were tested for analytical separation. A common mobile phase in steroid analysis is the use of ammonium hydroxide, whereas in this study the response for target compounds was far superior using a mobile phase containing 0.mM ammonium fluoride. Figure displays chromatograms comparing the two solvent results. A: Water 0.05% ammonium hydroxide B: Methanol 0.05% ammonium hydroxide A: Water 0.mM ammonium fluoride B: Methanol 0.mM ammonium fluoride 1 4 7 8 5 1 4 5 6 7 8 6 3 3 Figure Comparison of two different mobile phase solvents (pumps A and B) for eight target steroids. Peak #1 β-boldenone, # α-trenbolone, #3 Dienestrol, #4 Testosterone, #5 α-boldenone, #6 Hydroxystanozolol, #7 methyltestosterone, #8 Progesterone 3

In order to improve response at low levels and to improve recoveries, a multiple injection scheme was explored, essentially by using the trapping column as pre-concentration device. A bovine urine sample spiked at 10 pg/ul was injected multiple times using injection volumes of (5 µl, 10 µl, 0 µl, 30 µl) to give different total volumes loaded on the trap. Figure 3 displays the results of this study. It was found that several smaller injections, rather than one larger injection, provided much improved compound response. This difference was particularly evident in the results for β-boldenone. The final method utilised an injection scheme of 3 x 5 µl injections. A total injection volume of 15 µl was enough to acquire the necessary response at the lower calibration levels. Figure 3 Optimization of multiple loading injections onto the trapping column with different injection volumes (5 µl, 10 µl, 0 µl, 30 µl) Final method performance The final online trapping LC-MS/MS method was developed for eight steroids with LOQs below 0.5 pg/µl and a method cycle time of 0 minutes. This sensitivity permitted the quantification of steroids below the typical screening target concentration (STC) applied by food safety laboratories in bovine urine. Linearity was determined to be excellent for all compounds in the range 0.5 6 pg/µl, with R > 0.998 for all compounds studied. Peak area repeatability (n=6), assessed on the same day, was determined to be less than 4.6 % RSD for all compounds at pg/µl, and less than 3.6 % RSD at the higher concentration of 6 pg/µl. Matrix effects were assessed at 10 pg/µl for each compound and were found to vary significantly. The highest suppression was observed for dienestrol (90 %) and hydroxystanozolol (68 %), whereas lower suppression was observed for progesterone (14 %) and β-boldenone (9%). Deuterated internal standards were utilised to compensate for recovery and matrix effects. Figure 4 displays the calibration results (linear, 1/x) for each compound and an example chromatogram from a 1pg/ µl bovine urine sample. Calibration levels were analysed in duplicate and either Hydroxystanozolol d 3 or β-boldenone d 3 were used as internal standards for each compound. 4

Methyltestosterone R = 0.9994 β-boldenone R = 0.9979 α-boldenone R = 0.9997 α-trenbolone R = 0.9999 Progesterone R = 0.9994 Testosterone R = 0.9996 Hydroxystanozolol R = 0.9990 Dienestrol R = 0.9980 Table 4 Calibration curves (linear, 1/x) for each compound and example chromatogram in bovine urine spiked at 1 pg/µl 5

Conclusion An online-spe-lc-ms/ms method was developed for the quantification of eight steroids at low concentrations required by food safety laboratories. The methodology involved simple sample preparation and offers significant time savings in comparison to a two-step offline-spe procedure that is commonly used for this application. Preliminary validation data displayed excellent linearity for all compounds, low intraday %RSD, and good sensitivity at the lowest calibration level of 0.5 pg/µl. Multiple injections onto the trapping device were explored to improve compound response. It was found that several smaller injections, rather than one larger injection, provided much improved compound detection. Matrix effects were determined to be significant for most compounds, therefore deuterated internal standards were utilised to compensate. First Edition: June, 014 www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Shimadzu Corporation, 014