CB Svendsen A/S PS 2015.08.02/ rev. 1.5



Similar documents
How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

Servo Info and Centering

MOUNTING AND OPERATING INSTRUCTIONS

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Bluetooth HC-06 with serial port module Easy guide

PROXIMITY CARD READERS C-10, C-20, C60, C70

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

K-Type Thermocouple Sensor User s Guide

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

Application/Connection Examples

Manual for Fire Suppression & Methane Detection System

PRO PLM Installation Instructions

Installation Instructions. Thermo Call TC3

15 Series - Electronic step relay and dimmer. Features SERIE

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

R60 USB to CAN interface Manual (1.5 EN)

Remote Monitoring and REC 501 Control Unit Product Guide

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Installation Instructions. ThermoCall TC4. Entry/Advanced

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Inwall Room Temperature Unit

Contact Center CC-165 INSTALLATION & USER'S GUIDE

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

HERZ-Thermal Actuators

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

Users manual. TCW181B-CM_R1 Page 1

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Electronic Control Devices The European Product Catalogue 2007

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

ViZion Installation Guide

M-Bus Network Installation Notes

INSTALLATION AND OPERATION MANUAL

Setup guide. point to point wall plate extenders

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Digital Active Indoor Antenna SRT ANT 10 ECO

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

User Guide Reflow Toaster Oven Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

SECURITY SYSTEM ADP-CAN

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

TMS TANK MANAGEMENT SYSTEM

FIREDEX Conventional Fire Panels

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

MyM 3T. User Manual. English

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SYSTEM DESCRIPTION Termination Boards

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Current Monitoring Kit QUICK START GUIDE

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

8 Channel Status Input Panel model SIP-8

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

Broadway 3D Security System

Heating Controller. Building Technologies HVAC Products

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

Current Monitoring Kit

IntesisBox KNX Mitsubishi Heavy Industries AC

How To Set Up An Inverter

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Product and Application Description

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Model SRMD Setra Remote Monitoring Display

How To Program An Autodialer

WEB log. Device connection plans

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

QUICK REFERENCE MANUAL

Model 201 Wiegand Touchpad Reader Installation Guide

Digital Active Outdoor DVB-T/T2 Antenna SRT ANT 45

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

ICON Server box installation manual Rev. 1.1

Installation & User Manual Radio Remote rev1.0.3

GSM ALARM SYSTEM GCM 8

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

RC2200DK Demonstration Kit User Manual

Wireless Alarm system s manual

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Be careful when designing robots with multiple motors under simultaneous or heavy loading. There are three main points to consider:

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Installation, operation and maintenance manual TX 35A

MANUAL FOR RX700 LR and NR

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Manual for D1110 DigiCom2

GSM HOME SECURITY SYSTEM

DALI RC BASIC SO. Control unit Operating instructions

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Step by step guide to installing your own Ku Band satellite dish

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

is then retained absolutely without interruption.

Transcription:

CB Svendsen A/S PS 0.0.0/ rev... Description Installation guide for. The is designed for copying of signals from electricity-, heat- or water meters to s. This way, it is possible to connect a data logger and a at the same time. The can copy up to pulse based meters, and make timeshare for M-BUS based meter. The signals are copied through an optocoupler (pulses) and a relay (M-BUS). This ensures galvanic separation between the and the data logger. All pulse inputs towards the meters are specified with the S0 standard, and all pulse outputs towards the FA-0//0/ and the are specified with the S0 standard as well. The is CE approved cf. EN00- and EN00-. Temperature range for the is -0 C to C.. Physical placement of the CTS box The CTS box should be places close to the FA device. Maximum recommended cable length between and the FA device is meter.. Wall mounting of the The is made for wall mounting with self-tapping screws. Mounting holes are located inside the.. Connecting the CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +

CB Svendsen A/S PS 0.0.0/ rev.. Connecting a meter(s) (The left vertical connector in the ): The connector marked METER is used for connecting meters. It is only necessary to connect the number of meters that are in use. If the meter has a polarity independent pulse output (relay), there is no incorrect way to connect the pulse output of the meter. Connecting a (The right vertical connector in the ): The connector marked CTS is used for connecting a or other data acquisition equipment. It is only necessary to connect the number of outputs which are in use. Note: The can only receive signals from the if a FA (or other data logger, which can power the ) has been connected correctly! Connecting a FA type 0//0/ (The horizontal connector in the ): This connector is used for connecting a FA device. Not all terminals require a connection. Every pulse output from the meter is powered from the corresponding pulse input in the FA. A copying of pulses from a single pulse giving meter requires: wires from the FA, wires to the pulse output in the meter and wires for the copy signal for the. If the Timeshare function in the is used for a M-BUS port in a meter, terminal (P+) and terminal (G) on the horizontal connector must be connected to each other, as the function is powered through these terminals. The following pages contain some examples for typical mounting applications. x pulse setup: P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ P+ P- M+M- M+ M- 9 0 CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +

CB Svendsen A/S PS 0.0.0/ rev.. x pulse mounting: P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ P+ P- M+M- M+ M- 9 0 x M-Bus: P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ P+ P- M+M- M+ M- 9 0 CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +

CB Svendsen A/S PS 0.0.0/ rev.. x M-Bus with M-Bus converter for Siemens WR/: P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ MBUS conv. P+ P- M+M- M+ M- 9 0 x pulse, x M-Bus: P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ P+ P- M+M- M+ M- 9 0 CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +

CB Svendsen A/S PS 0.0.0/ rev.. Use of for sharing of M or M on FA-0//0/: The can be used on M or M on FA-0//0/. P+ P- P+ P- P+ P- P+ P- P+ P- P+ P- 9 0 FA-0//0/ P+ P- M+M- M+ M- 9 0 Note: T on the MUST connect to M+ (or M+). Do NOT connect to M- or M-! R on the MUST connect to M- (or M-). Do NOT connect to M+ or M+! Please note that: The has one Timeshare function, which means that an additional box is required, if both M and M are to be shared. If the multiport are to be shared as well, boxes are required. The FA-0 and FA- can connect an M-BUS meter on M and an M-BUS meter on M (along with an additional meter on the multi port). The FA-0 and FA- can connect up to M-BUS meters on M and additional meters on M (along with one additional meter on the multi port). The wiring to the is the same for FA-0//0/. The CAN NOT be used for FA-0//0/, IF an M-BUS meter requires a constant voltage on the M-BUS port. The detects when the FA device starts to power up the meters by putting a voltage on the port. The detects this, and activates a relay that reroutes the meters to the FA device. If a constant voltage is used, the meters will be permanently routed to the FA device. CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +

CB Svendsen A/S PS 0.0.0/ rev.. Sealing and powering the The is powered remotely by the FA device, and does not need any other external powering. Sealing the box (with thread or plastic) is possible via the sets of holes in two opposite corners on the.. Verifying the installation Pulse verification: After installation a test is performed, to see if the FA and receives pulses. FA- 0//0/ will flash momentarily with a red LED at every received pulse. Read the manual for the regarding test of pulses for the. M-BUS verification: When the M-BUS interface in the FA device is inactive, the M-BUS is connected directly to the through a relay. Please verify that communication can be performed between meter and (consult the manual for the CTS-system regarding this). M-BUS communication between the meter and the FA device is verified by performing a press-and-hold on the button on the FA device for more than.s, thus starting a manual reading. When the communication commence, the red LED on the will flash. This indicates that the M-BUS has been rerouted through the relay to the FA. Verify that the M- BUS reading is OK (i.e. by watching the LEDs on the FA, consult the installation guide for the FA if in doubt) and that the red LED on the turns off approximately seconds after the last activity on the M-BUS. Remember that the correct driver for the M-BUS based meter MUST be present/chosen in the FA-0//0/ before a correct result can be expected. CB-Svendsen A/S, Kirke Værløse vej, DK-00 Værløse, Tlf. +