RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:



Similar documents
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Quick Connect. quick - simple - efficient.

A project to optimise quality and energy efficiency must include metering

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Applications. diris_826_a_1_gb_cat

Energy Management Energy Meter Type EM23 DIN

Power Meter Series 700

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Metering Devices IQ Analyzer 6400/6600 Series

Energy Management Power Analyzer Type WM14-96 Basic Version

Pow-R-Con Multi Function Control

Application/Connection Examples

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Arc Terminator Active Arc-Resistant Switchgear

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Multifunction devices

E-STOP relays, safety gate monitors

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Polyphase kwh Electricity Meter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Preset Counter signo 721

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic Control Devices The European Product Catalogue 2007

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

38 Series - Relay interface modules A

T Substation Maintenance and Commissioning Test Equipment

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Specification Requirements DBL 700MX and 1000MX Series UPS

Safety technique. Emergency stop module BO 5988 safemaster

Bulletin 150 SMC Flex Smart Motor Controller Specifications

NC-12 Modbus Application

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

38 Series - Relay interface modules A

Telephone- and leased line modem for industrial applications TD-36

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Thyristor-controlled power supplies and battery chargers

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

3-phase, bidirectional energy meter

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Section D..General Auto Electrical Corporation

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

CQM1-SF200/CS1W-SF200

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PLA 44. Power quality analyzer. User and service manual. BMR trading

Waveguide Access Point WGA631. Product Guide

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Digital Clamp-on DMMs with uncompromising performance

Variable Preset Counter signo 723.1

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

SOLAR300N Rel /01/10

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

PNOZsigma - Base units

Electronic Timer - Series Micon 175

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

SINEAX U553 Transducer for AC Voltage

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

WINGLIKE ELECTRONICS CO.,LTD

Duct Humidity Transmitter

M2M The measure of efficiency

MasterINTERFACE 39 Series - Relay interface modules

1.44 kw Programmable DC Power Supplies XLN Series

March 15th 2005 EI Solutions - Submetering 1

One Meter Works for Both Energy Saving and Power Quality Surveillance

Cross-beam scanning system to detect slim objects. 100 mm in

Rack mounted telephone- and leased line modem for industrial applications

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Transcription:

Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog pane l meters. It measures electrical parameters like AC current, Voltage, frequency, Active energy import. The instrument has optional pulse output as one for Utility and another for Generator. RISH EM 3490 DS Product Features: Dual Source Energy Measurements : Rish EM 3490 DS features two energy integrator Utility & Generator. In normal operation meter accumulates energy counts in utility register & when utility shutdowns and control input signal of (10 to 60V DC/ 20 to 300V AC) is present on generator sensor energy starts accumulating in Generator register. On site programmable PT/CT ratios: It is possible to program primary of external potential Transformer (PT), primary of external Current Transformer (CT) on site locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485) User selectable PT Secondary The secondary of external potential Transformer (PT) can be programmed on locally via front panel keys by entering into Programming mode or remotely via MODBUS (Rs485) User selectable 3 phase 3W or 4W User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485). For single phase applications, single phase version is available. Low back depth: The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output Onsite selection of Auto scroll / Fixed Screen User can set the display in auto scrolling mode or fixed screen mode locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485). True RMS measurement The instrument measures distorted waveform up to 15th Harmonic. High brightness 2 line 7 digits LED display: Simultaneous displays Utility and Generator parameters. Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen. The displayed screen will get memorized only if user keeps this screen for minimum 40 sec duration before power failure for fixed screen mode. User Assignable Registers for MODBUS: Customer can assign MODBUS register address as per his need for faster response time. Hour Run, ON Hour, Number of Interruptions: Hour run records the number of hours load is connected. ON Hour is the period for which the auxiliary supply is ON. Number of Interruptions indicates the number of times the Auxiliary Supply was interrupted. All these parameters are displayed in both utility & generator mode. Energy Count storage: In case of power failure, the instrument memorizes the last energy count. Every 40 sec, the instrument updates the energy counter in the non-volatile memory. Programmable Energy format & Energy rollover count: Customer can assign the format for energy display on MODBUS (RS485) in terms of W, kw or MW. Additional to this, customer can also set a rollover count from 7 to 13 digits depending on the energy format, after which the energy will roll back to zero. Old Register This register holds the value before the last reset. The old value will be available when scrolled through screen. Optional MODBUS (RS485) Output The optional ModBus output enables the instrument to transmit all the measured parameters over standard MODBUS (RS485). Optional Pulse Output The instrument has optional pulse output one for Utility and another for Generator. The optional pulse output is a potential free, very fast acting relay contact which can be used to drive an external mechanical counter for energy measurement. Configuration of the Instrument via MODBUS: The instrument settings can be configured locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485). Note: The MODBUS communication parameters can only be set locally via front panel keys in the Programming mode. Enclosure Protection for dust and water: conforms to IP 54 (front face) as per IEC60529 Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1- 2001 EMC Compatibility Compliance to International standard IEC 61326. Page 1/8

Technical Specifications: Input Voltage: Nominal input voltage (AC RMS) Phase Neutral 57.7-277V L-N Line-Line 100-480V L-L Max continuous input voltage 120% of rated value Input Current: Nominal input current 1 and 5A AC RMS (to be specified while ordering) System CT primary values Std. values up to 4kA (1 or 5 Amp ) Max continuous input current 120% of rated value Starting current 0.4 % of In (In = Nominal Current) Auxiliary Supply: ACDC Auxiliary Supply DC Auxiliary Supply AC Auxiliary supply frequency range VA Burden: Nominal input voltage burden Nominal input current burden AC Supply burden Overload Withstand: Voltage Current Operating Measuring Ranges Voltage Current Frequency Power Factor 100V 250 VAC DC 12..48 VDC 45 to 66 Hz < 0.2 VA approx. per phase < 0.6 VA approx. per phase 4 VA 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x for 1 second, repeated 5 times at 5 min 5 120% of rated value 5 120% of rated value 40 70 Hz 0.5 Lag... 1... 0.8 Lead Reference conditions for Accuracy: Reference temperature 23 C +/- 2 C Input waveform Sinusoidal (distortion factor 0.005) Input frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Power Factor 0.5 lag.1.0.8 lead Accuracy: Voltage Current Frequency Active Power Reactive Power Apparent Power Active energy (kwh) Power Factor Phase angle Measurement error is normally much less than the error specified above. Variation due to influence quantity is less than twice the error allowed for reference condition ±0.5% of range (50... 100% of rated value) ±0.5% of range (10... 100% of rated value) 0.15% of mid frequency ±0.5% of range (10... 100% of rated Current value & 50... 100% of rated Voltage value) ±0.5% of range (10... 100% of rated Current value & 50... 100% of rated Voltage value) ±0.5% of range (10... 100% of rated Current value & 50... 100% of rated Voltage value) 1 % (IEC 62053-21) Active P.F. 0.5 lag... 1...0.8 lead 1 % of Unity 1 % of range Generator Sensor: 10 to 60 VDC / 20 to 300 VAC (For monitoring generator ON or OFF). Applicable Standards: EMC IEC 61326 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial low level Safety IEC 61010-1-2001, Permanently connected use IP for water & dust IEC60529 Pollution degree: 2 Installation category: CAT III 300V ac rms High Voltage Test 2.2 kv AC, 50Hz for 1 minute between all electrical circuits Page 2/8

Technical Specifications: Environmental Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Enclosure Enclosure style: Enclosure style Enclosure material Terminals Fixing -10 to +55 C -20 to +65 C 0... 90% non condensing Minimum 3 minute 15g in 3 planes 10... 55 Hz, 0.15mm amplitude Ip54 (front face only) 96 X 96 DIN Quadratic) Polycarbonate (Self extinguish & non dripping as per UL 94 V-0) M4 Screw Type 4 side clamps Pulsed Output Option: Two optional pulse outputs are provided one for Utility pulse out and another for Generator pulse out Relay Contact One Normally open Pulse Rate Divisor Pulse System power* 1 per Whr Up to 3600W 1 1 per kwhr Up to 3600kW 1 per MWhr Above 3600kW 1 per 10 Whr Up to 3600W 10 1 per 10 kwhr Up to 3600kW 1 per 10 MWhr Above 3600kW 1 per 100 Whr Up to 3600W 100 1 per 100 kwhr Up to 3600kW 1 per 100 MWhr Above 3600kW 1 per 1000 Whr Up to 3600W 1000 1 per 1000 kwhr Up to 3600kW 1 per 1000 MWhr Above 3600kW Note: Divisor 10,100,1000 is applicable only when Energy Display on RS485 is selected in terms of Watts *System Power = CT(Primary) x PT(Primary) *System Power = 3xCT(Primary) x PT(Primary)L-N *System Power = Root3xCT(Primary) x PT(Primary)L-L Pulse Width = 60mS, 100mS, 200mS PT Secondary Ranges for Various Input Voltage: for single Phase for Three Phase four wire for Three Phase three wire Input Voltage 110V L-L (63.5V L-N) 230V L-L (133V L-N) 415V L-L (239.6V L-N) PT Secondary Settable Range 100V 120V L-L (57V 69V L-N) 121V 239V L-L (70V 139V L-N) 240V 480V L-L (140V 277V L-N) Page 3/8

Displayed Parameters: Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire 1. System Current ü ü ü 2. Current L1 ü ü û 3. Current L2 ü ü û 4. Current L3 ü ü û 5. System Active Power (kw) ü ü ü 6. Active Power L1 (kw) ü û û 7. Active Power L2 (kw) ü û û 8. Active Power L3 (kw) ü û û 9. Utility Import kwh ü ü ü 10. Utility Run Hour ü ü ü 11. Utility On Hour ü ü ü 12. Utility Number of Interruptions ü ü ü 13. Generator Import kwh ü ü ü 14. Generator Run Hour ü ü ü 15. Generator On Hour ü ü ü 16. Generator Number of Interruptions ü ü ü 17. Total Run Hour ü ü ü 18. Total On Hour ü ü ü 19. Total Number of Interruptions ü ü ü 20. Old Utility Import kwh ü ü ü 21. Old Utility Run Hour ü ü ü 22. Old Utility On Hour ü ü ü 23. Old Utility Number of Interruptions ü ü ü 24. Old Generator Import kwh ü ü ü 25. Old Generator Run Hour ü ü ü 26. Old Generator On Hour ü ü ü 27. Old Generator Number of Interruptions ü ü ü 28. Old Total Run Hour ü ü ü 29. Old Total On Hour ü ü ü 30. Phase Reversal Indication ü ü û Page 4/8

Parameters Through MODBUS: Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire 1. System Volts ü ü ü 2. System Current ü ü ü 3. Volts L1 N ü û û 4. Volts L2 N ü û û 5. Volts L3 N ü û û 6. Volts L1 L2 ü ü û 7. Volts L2 L3 ü ü û 8. Volts L3 L1 ü ü û 9. Current L1 ü ü û 10. Current L2 ü ü û 11. Current L3 ü ü û 12. Neutral Current ü û û 13. Frequency ü ü ü 14. System Active Power (kw) ü ü ü 15. Active Power L1 (kw) ü û û 16. Active Power L2 (kw) ü û û 17. Active Power L3 (kw) ü û û 18. System Re-active Power (kvar) ü ü ü 19. Re-active Power L1 (kvar) ü û û 20. Re-active Power L2 (kvar) ü û û 21. Re-active Power L3 (kvar) ü û û 22. System Apparent Power (kva) ü ü ü 23. Apparent Power L1 (kva) ü û û 24. Apparent Power L2 (kva) ü û û 25. Apparent Power L3 (kva) ü û û 26. System Power Factor ü ü ü 27. Power Factor L1 ü û û 28. Power Factor L2 ü û û 29. Power Factor L3 ü û û 30. System Phase Angle ü ü ü 31. Phase Angle L1 ü û ü 32. Phase Angle L2 ü û û 33. Phase Angle L3 ü û û 34. Import kwh (Utility /Generator) ü ü ü 35. kvah (Utility /Generator) ü ü ü 36. Run Hour (Utility /Generator / Total) ü ü ü 37. On Hour (Utility /Generator / Total) ü ü ü 38. Number of Interruptions (Utility /Generator) ü ü ü 39. Old Import kwh (Utility /Generator) ü ü ü 40. Old Run Hour (Utility /Generator / Total) ü ü ü 41. Old On Hour (Utility /Generator / Total) ü ü ü 42. Old Number of Interruptions (Utility /Generator) ü ü ü Page 5/8

Electrical Connections: For 3 Phase 4 Wire Unbalanced Load 2 5 8 11 1 3 4 6 7 9 13 14 L1 L2 L3 N L N + - AUX SUPPLY For 3 Phase 3 Wire Unbalanced Load 2 5 8 1 3 7 9 13 14 L1 L2 L3 L N + - AUX SUPPLY For Single Phase 2 11 1 3 13 14 L1 L2 L3 N L N + - AUX SUPPLY It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5 mm. 2 2 Permissible cross section of the connection wires: <= 4.0 mm single wire or 2 2.5 mm fine wire. Page 6/8

Generator Sense Connection diagram. Generator Sense Voltages AC Voltage : 20VAC to 300VAC DC Voltage : 10VDC to 60VDC Dimensions 96 mm 80 mm 92mm+0.8 Display Area 96 mm 92mm+0.8 Panel Cutout Page 7/8

Parameter Measurement and Display: Ordering information System Type (Connection network) 3 Phase (programmable as 4 Wire or 3 Wire on site) 3 1 Phase 1 Input Voltage 110V L-L (63.5V L-N) 110 230V L-L (133V L-N) 230 415V L-L (239.6V L-N) 415 440V L-L (254V L-N) 440 Input Current 5 Amps 5 1 Amps 1 Ordering Code RISH EM 3490 DS AC Auxiliary Voltage 100V 250 V AC DC -10% / +10 % 12V 48V V DC -10% / +10 % Optional: MODBUS (RS485) output MODBUS Option not used Optional: Pulse Output for energy measurement Pulse output (Utility / Generator) Pulse Output option not used AD D R Z UG Z Order Code Example: RISH Master 3490DS 3 415-AD-R-UG RISH Master 3490DS, Rish EM 3490 DS, 3 phase( programmable onsite as 4 wire or 3 Wire), 415L-L nominal voltage, 5Amps nominal input current,100 250V AC DC Auxiliary supply, with MODBUS (RS485),with pulse output. Types 100...250VACDC 12 48 VDC Aux Aux 3490 DS ü ü 3490 DS + 2 pulse ü ü 3490 DS + Rs485 ü ü 3490 DS + 2 pulse + Rs485 ü ü Rishabh Instruments always tries for innovation and therefore product specifications are subject to change without notice Page 8/8