Experimental Study of Active Magnetic Regenerator (AMR) Composed of Spherical GdN



Similar documents
Environmentally Friendly Magnetic Refrigeration Technology Using Ferromagnetic Gd Alloys

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

Low Temperature Adsorption Versus Pore Size in Activated Carbons

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

Development of High-Speed High-Precision Cooling Plate

Calculating Heat Loss by Mark Crombie, Chromalox

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Laser sintering of greens compacts of MoSi 2

Steady Heat Conduction

Thermal Storage Unit Using the Triple Point of Hydrogen

The Second Law of Thermodynamics

Crystal Structure of High Temperature Superconductors. Marie Nelson East Orange Campus High School NJIT Professor: Trevor Tyson

Temperature. Temperature

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

TECHNICAL BRIEF Critical Point Drying

Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Verification Experiment on Cooling and Deformation Effects of Automatically Designed Cooling Channels for Block Laminated Molds

CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER

Effective Cooling Method for Spin Casting Process

Exergy: the quality of energy N. Woudstra

The First Law of Thermodynamics

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

Development of a Diaphragm Stirling Cryocooler [THO10-1]

A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods

HEAT TRANSFER ENHANCEMENT IN FIN AND TUBE HEAT EXCHANGER - A REVIEW

Laser beam sintering of coatings and structures

18th International Congress of Mechanical Engineering

Energieffektive og miljøvenlige afkøling ved hjælp af magnetiske køling. Nini Pryds

Sizing Circuit Breakers for Self-Regulating Heat Tracers

Investigation of Experimental and Numerical Analysis on Extrusion Process of Magnesium Alloy Fin Structural Parts

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

The D-Wave 2X Quantum Computer Technology Overview

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS *

Waste Heat Recovery through Air Conditioning System

Diffusion and Fluid Flow

In order to solve this problem it is first necessary to use Equation 5.5: x 2 Dt. = 1 erf. = 1.30, and x = 2 mm = m. Thus,

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Direct Conversion of Wind Energy into Heat Using Joule Machine

Chapter 8 Maxwell relations and measurable properties

Introduction to acoustic imaging

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Physics 5D - Nov 18, 2013

WJP, PHY381 (2015) Wabash Journal of Physics v4.3, p.1. Cloud Chamber. R.C. Dennis, Tuan Le, M.J. Madsen, and J. Brown

A Practical Guide to Free Energy Devices

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Basic Properties and Application Examples of PGS Graphite Sheet

Numerical analysis of size reduction of municipal solid waste particles on the traveling grate of a waste-to-energy combustion chamber

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

Fall 2004 Ali Shakouri

Calibration of Dallas sensors

Performance Test of Solar Assisted Solid Desiccant Dryer

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

The Properties of Water (Instruction Sheet)

Calculation of Liquefied Natural Gas (LNG) Burning Rates

Type: Single Date: Homework: READ 12.8, Do CONCEPT Q. # (14) Do PROBLEMS (40, 52, 81) Ch. 12

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

The Second Law of Thermodynamics

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Name: Period: # Plate Tectonics. Journey to the center of the Earth

CONSOLIDATION AND HIGH STRAIN RATE MECHANICAL BEHAVIOR OF NANOCRYSTALLINE TANTALUM POWDER

Physical & Chemical Properties. Properties

Processes Within an Ecosystem

Der Einfluss thermophysikalischer Daten auf die numerische Simulation von Gießprozessen

Define the notations you are using properly. Present your arguments in details. Good luck!

Glancing XRD and XRF for the Study of Texture Development in SmCo Based Films Sputtered Onto Silicon Substrates

VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied.

The Cost of Superconducting Magnets as a Function of Stored Energy and Design Magnetic Induction times the Field Volume

Lecture 7 Thermal Insulation & Cryostat Basics. J. G. Weisend II

Humid Air. Water vapor in air. Trace Glasses 1% Argon (A) Water vapor (H 2

Drying Parawood with Superheated Steam

Description of Thermal Oxidizers

An Experimenatl Study on Heat Transfer Behaviors of A Welded - Aluminum Minichannel Heat Exchanger

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

RESPONSE TIME INDEX OF SPRINKLERS

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

A Study of a MV Cable Joint

Figure CPT Equipment

NUCLEAR ENERGY RESEARCH INITIATIVE

Brookhaven Magnet Division - Nuclear Physics Program Support Activities

Energy Conservation Measures due to Industrial Gas Supply Business Model Innovation

Lecture: 33. Solidification of Weld Metal

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

A. Martinez, A. L. Klebaner, J. C. Theilacker, B. D. DeGraff, M. White and G. S. Johnson

Permanent Magnet Materials

A NUMERICAL AND EXPERIMENTAL STUDY OF THE FACTORS THAT INFLUENCE HEAT PARTITIONING IN DISC BRAKES

Development of large-scale H 2 storage and transportation technology with Liquid Organic Hydrogen Carrier (LOHC)

AUTOMATIC ADJUSTMENT FOR LASER SYSTEMS USING A STOCHASTIC BINARY SEARCH ALGORITHM TO COPE WITH NOISY SENSING DATA

Journal bearings/sliding bearings

Free piston Stirling engine for rural development

New Trends in the Field of Automobile Air Conditioning

Materials 10-mL graduated cylinder l or 2-L beaker, preferably tall-form Thermometer

How To Calculate The Performance Of A Refrigerator And Heat Pump

Transcription:

Experimental Study of Active Magnetic Regenerator (AMR) Composed of Spherical GdN Y. Hirayama 1, H. Okada 1, T. Nakagawa 1, T.A. Yamamoto 1, T. Kusunose 1, T. Numazawa 2, K. Mastumoto 3, T. Irie 4, and E.Nakamura 4 1 Osaka University, Osaka, Japan 2 National Institute for Materials Science, Tsukuba, Ibaraki 305-0003, Japan 3 Department of Physics, Kanazawa University, Kanazawa 920-1192, Japan 4 SANTOKU Corporation, Kobe, Hyogo 674-0093, Japan ABSTRACT An experimental study of an active magnetic regenerator (AMR) employing GdN was carried out. Spherical GdN material was synthesized by the hot isostatic pressing (HIP) method. The specific heat was measured and the magnetic entropy change ΔS and adiabatic temperature change ΔT ad were calculated. The refrigeration with an AMR cycle was tested in the temperature range between 48 and 66 K with the field swinging from 1.2 to 3.7 T at upper side and from 2.0 to 4.0 T at lower side of the regenerator bed filled with GdN spheres. A temperature span, ΔT span,was found to develop soon after starting the cycle and became more than 4.7 degree in steady state. This temperature span ΔT span was at least 1.5 times as large as the adiabatic temperature change ΔT ad. INTRODUCTION For the hydrogen society expected in the near-future, the high efficiency transport and storage of hydrogen is an important requirement. Liquid hydrogen provides the highest hydrogen densities with respect to both mass and volume. To liquefy hydrogen, it must be cooled down to 20 K. However, the efficiency of conventional cooling systems using gaseous refrigerant generally decreases with lowering temperature, so that much energy is required to liquefy hydrogen. Magnetic refrigeration has thepotential to provide higher efficiency at low temperatures, because it is based on the magnetocaloric effect (MCE) which is associated with an intrinsically small irreversibility. The magnetic entropy change ΔS is extracted by a swinging magnetic field axis externally applied to a ferromagnetic material. The change is lowest in the vicinity of the Curie temperature. This ΔS is converted directly into heat, Q = TΔS. Application of this concept to a hydrogen liquefaction system has been proposed. 1 To realize the magnetic cooling for hydrogen liquefaction, development of a suitable magnetic refrigerant is absolutely necessary. We have found several rare earth nitrides that are promising candidate materials for the magnetic refrigerant working between 4 ~ 80 K due to some remarkable characteristics. 2-6 Magnetic refrigeration has been well studied at temperatures, near 20 K 7,8 and at room temperature. 9-12 However, in the temperature range of 20 ~ 77 K, only Matsumoto et al. 7 has designed 531

532 SUB-KELVIN, MAGNETIC, AND NOVEL REFRIGERATORS and constructed an Ericsson magnetic regenerator using a 5 T superconducting magnet. They employed DyAl 2.2 as the magnetic working substance and obtained temperature span of 8.4 degree (58.7 ~ 50.3 K). 13 Active magnetic regenerator (AMR) refrigeration is as alternative cycle proposed for refrigeration and gas liquefaction. This technology is based upon the magnetocaloric effect, a nearly reversible temperature change induced by a magnetic field change. AMR refrigeration devices have the potential to be more efficient than those using conventional refrigeration techniques. In this paper, we report on the magnetic refrigeration test with the AMR cycle employing GdN spheres as the magnetic refrigerant in the 48 ~ 66 K temperature range. EXPERIMENT Starting materials of spherical Gd metal (φ: 0.85 ~ 1.00 mm, 99.9% purity) were processed in a Hot Isostatic Press (O 2 -Dr. HIP; Kobelco Co., Ltd.) at 1873 K in 200 MPa N 2 gas of 99.9999% purity for 2 hour. This condition was allowed the starting materials to be transformed into spherical GdN free from unwanted deformation and/or cracks caused by unbalanced progresses of nitrogen diffusion and nitride formation leading to a density gap. The X-ray diffraction (XRD) pattern of the product was measured with a diffractometer (RINT Ultima+, Rigaku) using Cu-Ka radiation to examine the resultant phases. The specific heat was measured using a physical property measurement system (PPMS model 6000, Quantum Design, Inc.) at 2-100 K under several magnetic fields (0, 1.2, 2.0, 3.8, 4.0, 5.0, 7.0 T). These temperatures and fields are anticipated for the regenerator bed in the present refrigeration test. The regenerator bed was filled with the GdN spheres with a total mass of 313 g. Two thermometers were located near upper and lower sides of the regenerator bed as shown in Fig. 1(a). Helium gas at 0.13 MPa filled the cylinder as heat transfer fluid. In this apparatus, the AMR cycle was operated by moving the regenerator bed and the gas in a superconducting magnet along its axial direction. The gas flow through the bed was driven by moving the closed cylinder separately. The present AMR cycle consists of four processes as shown in Fig. 1(b). In the magnetization process, (1) (2), the regenerator bed and the cylinder go into the magnet, then the GdN is magnetized and heated by the magnetocaloric effect. In the hot-to-cold flow process, (2) (3), only the cylinder goes up making the He gas flow upward through the bed and remove heat from the magnetic material whic makes a temperature gradient in the regenerator bed across its lower (cold) and upper (hot) sides. In the demagnetization process, (3) (4), the regenerator bed and the cylinder come out of the magnet, which demagnetizes and cools the GdN. In cold-to-hot flow process, (4) (1), only the cylinder goes down making the He gas flow downward through the bed and gives heat to the GdN. By cycling these processes, a temperature span is obtained in the regenerator bed. The total cycle period was 8 sec, consisting of these four processes (magnetization, hot-tocold, demagnetization, and cold-to-hot) of 2 sec each. The swinging magnetic field applied to the (a) Regenerator bed (b) AMR cycle Figure 1. (a) Inner structure of regenerator bed, (b) Four elementary processes of AMR cycle, (1) (2); magnetization, (2) (3); cold-to-hot flow, (3) (4); demagnetization, (4) (1); hot-to-cold flow.

ACTIVE MAGNETIC REGENERATOR OF SPHERICAL GDN 533 bed was 1.2 ~ 3.7 T at the upper side and 2.0 ~ 4.0 T at the lower side of the regenerator bed. These field strengths were indirectly determined from readings of a magnetic sensor attached to the outer surface of the cylinder at its axial positions and magnet currents. The AMR cooling experiment starts after the system has attained a thermal equilibrium at 51 K which is given as a balance between cooling and heating respectively performed by a GM refrigerator and heaters attached to the cylinder. RESULTS AND DISCUSSION XRD patterns of the GdN product indicated an NaCl-type structure only and free from that of oxide. 14 Figure 2 shows a photograph of GdN synthesized by HIP which shows a spherical shape (0.986 mm, mean diameter) without unwanted deformation and/or cracks. Figure 3 shows the specific heats vs. temperature curve of the GdN sample measured under each magnetic field. Note that the curve measured at zero-field exhibits a clear lambda-type peak at 65 K, evidencing occurrence of a ferro-para transition. 15 Increasing the magnetic field, the peak is diminished gradually and the curve at 7 T increases monotonically with temperature. T CH ( T) By substituting these C H versus T data sets into SH ( T) = dt, entropy curves as shown 0 T in Fig. 4 were obtained for each field. From these S H T curves, the magnetic entropy change ΔS and the adiabatic temperature change ΔT ad are obtained graphically. The ΔS T curve is thus obtained in Fig. 5(a). Fig. 5(b) is ΔT ad plotted against the temperature at which the demagnetization is given and the cooling starts. It is noticed that these curves have peaks located near the Curie temperature. At the beginning of the AMR operation, there is no temperature span at 51 K. Figure 6(a) shows time traces of the temperatures measured at upper and lower sides of the regenerator bed Figure 2. Photograph of spherical GdN particles Figure 3. Specific heat, C H, of GdN as a function of temperature at each magnetic field (0, 1.2, 2.0, 3.8, 4.0, 5.0, 7.0 T). Figure 4. Entropy, S H, calculated from specific heat measurement data set under magnetic at each magnetic field (0, 1.2, 2.0, 3.8, 4.0 T).

534 SUB-KELVIN, MAGNETIC, AND NOVEL REFRIGERATORS Figure 5. Temperature dependence of ΔS; (a) and ΔT ad ; (b) as magnetic field swings from 3.7 to 1.2 T at upper side and from 4.0 to 2.0 T at lower side. Figure 6. (a) Temperature time traces at upper and lower sides of the regenerator bed filled with GdN in 300 sec. (b) Temperature span ΔT span in each cycle read in Fig. 6(a). from 0 300 sec. As the cycle proceeds, temperature spans develop and attain steady states after 150 sec. The temperature spans observed at the lower and the upper sides are both about 2 degrees. Besides the spans, both of the temperatures are noticed to rise gradually, which is attributed to a heat influx from the shaft which drives the regenerator bed. ΔT span (= T upper, max T lower, min ) in one cycle after steady state is shown in Fig. 6(b). ΔT span is maintained about 4.7 degrees through 54 ~ 66 K, which is 1.5 times larger than the adiabatic temperature change ΔT ad of GdN as shown in Fig. 5(b). These findings directly indicate that the AMR cycle indeed works. Note a peak near 63 K corresponding to the peak in Fig. 5(b), which provides evidence that the temperature spans observed in this test are induced by the magnetocaloric effect of GdN. SUMMARY Spherical GdN material without deformation and/or cracks was successfully synthesized by hot isostatic pressing. The refrigeration test of the AMR cycle was performed. The steady state was produced in 150 sec and α ΔT span of more than 4.7 degrees was achieved in the temperature range between 54 ~ 66 K at ΔH = 2 2.5 T (3.7 ~ 1.2 T; upper side, 4.0 ~ 2.0 T; lower side). The specific heat, C H, was measured under different fields (0, 1.2, 2.0, 3.8, 4.0, 5.0, 7.0 T). ΔS and ΔT ad were calculated from the C H T curves. A temperature span, ΔT span, was 1.5 times as large as ΔT ad in a wide temperature range (54 K ~ 66 K), proving that AMR cycle works well. ACKNOWLEDGMENTS This research was partially supported by Grant-in-Aid for Scientific Research (A), (No. 19206074), by Grant-in-Aid for JSPS Fellows (No. 22.726) and by the JST in the project of Collaborative Development of Innovation Seeds, Potentiality verification stage ( 08). The support of the Institute of Applied Energy provided by NEDO in the project of Search and Research of Inno-

ACTIVE MAGNETIC REGENERATOR OF SPHERICAL GDN 535 vative and Leading Technologies was greatly appreciated. An Experimental support is provided by Mr. Hattori and Hirano who belong to the Nakagome Lab. in Chiba University. REFERENCES 1. Pecharsky, V. K. and K. A. Gschneidner Jr, Magnetocaloric effect and magnetic refrigeration, Journal of Magnetism and Magnetic Materials, Vol. 200, No. 1, (1999), pp. 44-56. 2. Nishio, S., T. Nakagawa, et al., Specific heat and thermal conductivity of HoN and ErN at cryogenic temperatures, Journal of Applied Physics, Vol. 99, 08K901, (2006). 3. Hirayama, Y., T. Nakagawa, et al., Magnetocaloric effects of binary rare earth nitrides, Material Research Society, (2008), pp. 152-157. 4. Hirayama, Y., N. Tomioka, et al., Magnetocaloric effect, specific heat and adiabatic temperature change of Ho x Er 1-x N (x = 0.25, 0.5, 0.75), Journal of Alloys and Compounds, Vol. 462, L1-2, (2008). 5. Nakagawa, T., T. Arakawa, et al., Magnetocaloric effects of ferromagnetic erbium mononitride, Journal of Alloys and Compounds, Vol. 408-412, No. (2006), pp. 191-195. 6. Yamamoto, T. A., T. Nakagawa, et al., Magnetocaloric effect of rare earth mono-nitrides, TbN and HoN, Journal of Alloys and Compounds, Vol. 376, No. 1-2, (2004), pp. 17-22. 7. Matsumoto, K., et al., Magnetic refrigerator for hydrogen liquefaction, Journal of Physics: Conference Series, Vol. 150, No. 1, (2009), 012028. 8. Barclay, J. A., W. F. Stewart, et al., Experimental results on a low-temperature magnetic refrigerator, Adv. in Cryogenic Engineering, Vol. 31, Plenum Publishing Corp., New York, (1986), pp. 743-752. 9. Rowe, A. and A. Tura, Experimental investigation of a three-material layered active magnetic regenerator, International Journal of Refrigeration-Revue Internationale Du Froid, Vol. 29, No. 8, (2006), pp. 1286-1293. 10. Zimm, C., A. Boeder, et al., Design and performance of a permanent-magnet rotary refrigerator, International Journal of Refrigeration, Vol. 29, No. 8, (2006), pp. 1302-1306. 11. Zheng, Z. G., H. Y. Yu, et al., Design and performance study of the active magnetic refrigerator for roomtemperature application, International Journal of Refrigeration, Vol. 32, No. 1, (2009), pp. 78-86. 12. Kim, Y. and S. Jeong, Investigation on the room temperature active magnetic regenerative refrgerator with permanent magnet array, Adv. in Cryogenic Engineering, Vol. 55, Amer. Institute of Physics, Melville, NY (2010), pp. 87-94. 13. Matsumoto, K., T. Ito, et al., An Ericsson Magnetic Refrigerator for Low Temperature, Adv. in Cryogenic Engineering, Vol. 33, Plenum Publishing Corp., New York (1988), pp. 743-750. 14. Nakagawa, T., Sako, K., et al., Magnetocaloric effects of binary rare earth mononitrides, Gd x Tb 1-x N and Tb x Ho 1-x N, Journal of Alloys and Compounds, Vol. 408-412, (2006), pp. 187-190. 15. Hirayama, Y., Nakagawa, T., et al., Magnetocaloric Effect of Rare Earth Nitrides, IEEE Transactions on Magnetics, Vol. 44, No. 11, (2008), pp. 2997-3000.