Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008



Similar documents
Upstand Rooflight Natural Light Translucent Upstand Systems

Kingspan Envirodek Structural Green Roof System

Kingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

ALUMINIUM. Product Data Sheet

Composite Panel Firewall Systems

Building to the Power of

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Rockwool Cladding Roll

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Construction details. Technical specifications

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Installation Detailed installation instructions are provided which should be strictly followed.

Corus Panels and Profiles. Roof and Wall Composite Panels

Colonnade Security Pipe

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Preformed Metal Roofing and Siding

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Glass partitions SFB 3074

PROFILED METAL ROOFING DESIGN GUIDE

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

The WANZ Guide to Window Installation

Installation Window Building In Details

Light Architecture. Colors Sweden. Light

Fire Resistant Systems

MULTI ROOFING. Our Services.

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

The Kingspan Insulation Price List 1 st January 2013

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Architectural composite panels

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

ProRox Slabs (formerly known as RW slabs)

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

The WANZ Guide to Window Installation

I-Line - Snap-On Feature

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Prefabricated building PVC vertical sliding window

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

December J-Ply Roofing, Flooring and Decking

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Peninsula Place, Greenwich, London

Rockwool Flexi Insulation Application Guide

Unbeatable energy efficient glass curtain wall system

SECTION STANDING SEAM METAL ROOFING

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Low Energy Low Carbon Buildings

comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites.

Building Owners Guide to a Duro-Last System!

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Colours from Kingspan

SECTION STANDING SEAM METAL ROOF

KALZIP STANDING SEAM ROOF SYSTEMS KALZIP DECK ROOF SYSTEM

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Ubiflex. Non-lead flashing system

Steel-framed Walls. Insulation

Sun Windows General Information Sun New Construction Window Installation Instructions

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Product Data Sheet ROCKPANEL Rockclad

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

DELTA Premium Moisture Management Systems for Foundations.

Confort 160. Sliding Systems. Sapa Building System

CDW Systems Ltd Contemporary Doors & Windows

BETONYP building boards. The modern way of living.

Data Centre Integrated Construction Solutions

Low Energy Low Carbon Buildings

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

GYPSUM AREA SEPARATION FIREWALLS GA

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Transcription:

Insulated Panels CI/SfB (4-) Rh2 September 2008 INSULATED WALL SYSTEMS Longspan Architectural Frame to Frame Insulated Panel System Approved to LPS 1181 Certificate No. 186a & 260a

Longspan is a frame to frame insulated wall panel system which can eliminate secondary steel work The paper we have printed on is from 80% postconsumer waste and the remaining 20% pulp is TCF (Totally Chlorine Free). This fibre is FSC certified (see fsc.org for details). In recognition, the range has been awarded both the NAPM and Eugropa recycled marks, two of the most prestigious and recognisable recycled certificates available. The ink we have used is vegetable based, allowing the document to be recycled. Sustainable Forest Recyclable Vegetable Based 2

Contents Contents Introduction 5 Product Data 6 Construction Details 10 3

4 The Longspan system is a high performance construction solution providing external architectural aesthetics combined with faster on-site installation

Introduction The KS1000 LS Longspan System is a cost effective architectural wall system which provides quicker project completion, simpler installation and guaranteed performance. KS1000 LS Longspan wall panels can span up to 8.2 metres from support to support, providing enhanced aesthetics and reducing the need for secondary steelwork. Performance Advantages Property & Business Protection - Loss Prevention Certification Board (LPCB) LPS 1181 certified insurer approved systems deliver certainty of performance and insurability. Complies with HSA/HSE and CDM safety requirements. Fully complies with Part L2 (England & Wales) Building Regulations and Section 6 (Scotland) Technical Handbooks. Lifetime insulation continuity, thermal performance and airtightness (5m 3 /hr/m 2 ) certainty. Frame to frame spanning capability of up to 8.2 metres. Available in cover widths of 600, 900 and 1000mm. Standard Architectural Panel Six external architectural profiles available Simple integration with doors, windows, glazing, louvres and traditional construction materials. Suitable for horizontal or vertical application. Accelerated build speed through pre-engineered, single component, single-fix installation, that can reduce site times by up to 50%. Introduction Environmentally sustainable system - zero ODP and non-deleterious. Guaranteed for up to 25 years for thermal and structural performance through TOTAL Guarantee. Quality approved to ISO 9001: 2000. s manufacturing plants are ISO 14001 (Environmentally) and ISO 18001 (Health & Safety) accredited. Approved to LPS 1181 Certificate No. 186a & 260a KS600/900/1000 LS Longspan Panel 5

Product Data Application KS1000 LS Longspan is a frame to frame long spanning, secret fixed system which can be laid horizontally and vertically. It is suitable for all building applications except where there are low temperature controlled environments. Product Reference KS600/900/1000 Application Description KS1000 LS Longspan wall panel with Loss Prevention Certification Board (LPCB) approval for wall applications. KS600/900/1000 LS 600/900/1000mm cover width Core thickness A - Core thickness (mm) 80 100 120 140 Weight (kg/m 2 ) 0.63/0.63 steel 15.4 16.2 17.0 17.8 Product Tolerances Cut to Length (mm) -5 +5 Cover Width (mm) -2 +2 Thickness (mm) -2 +2 End Square (mm) -3 +3 Flatness per metre (mm) -2 +2 Profiles Available The external weather sheet is available in six profiles: MR (Micro-Rib) EB (Euro-Box) MM (Mini-Micro) WV (Wave) CX (Convex) FL/FL-S (Flat) Available Lengths Standard lengths of 1.8 to 12.0 metres, 12.1 to 16 metre panels can be supplied but are subject to a transport surcharge. Panels less than 1.8m long can be supplied and are subject to an extra cost. Panel length Material Steel Substrate Standard external sheet thickness 0.63mm, standard internal sheet thickness 0.63mm. Other thicknesses can be supplied to special order. Coatings External Weather Sheet XL Forté : 200 micron thick high performance coating applied to the weatherside of the panel. Designed to achieve high levels of durability and colour stability and is highly resistant to damage in transit and on-site. Spectrum - polyurethane semi-gloss coating. Colorcoat Prisma - 50 micron thick coating. 16 metallic colours. HPS200 Ultra - Nominal 200 micron thick high performance coating. Reverse side of sheet coated with grey polyester coating. The steel is available in either plain or stucco embossed finish. Coatings Internal Liner Sheet Bright White Polyester: Coating developed for use as the internal lining of insulated panels. Standard colour is bright white with an easy clean surface. Aquasafe 200: 200 micron thick coating used in areas where there is high internal humidity, or a corrosive environment. Cleansafe: a chemically inert polymer film bonded to steel substrate for cladding of cold stores, food processing buildings and other hygiene applications. Reverse side of sheet coated with a light grey polyester coating. The sheet is available in either plain or stucco embossed finish. These panels cannot be end lapped. 6

Insulation Core The core of KS1000 LS Longspan is a, closed cell PIR insulation which is non-deleterious with zero Ozone Depletion Potential (zero ODP). Seals Factory Applied Side Joint Seal All side joints have a factory applied seal fitted into the groove to automatically seal the joint between panels. Performance Thermal Insulation Panel Thickness (mm) U-value W/m 2 K 80 0.30 100 0.23 120 0.17 140 0.15 U-value - Thermal transmittance W/m 2 K Biological KS1000 LS Longspan panels are resistant to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the manufacture of the panels. Fire Steel inner and outer facings have a Class 1 surface spread of flame to BS476 Part 7: 1987, and are Class 0 as defined by the Building Regulations. KS1000 LS Longspan is approved by the Loss Prevention Certification Board (LPCB) to LPS1181. KS1000 LS Longspan panels have a core which has been specially formulated to provide the following benefits: Stable protective char No flash over No flame spread No flame propagation Acoustics All KS1000 LS Longspan panels have a single figure weighted sound reduction Rw = 25dB. Sound Reduction Index (SRI) Frequency (Hz) SRI (db) 125 20.1 250 21.1 500 24.6 1000 24.9 2000 29.6 4000 38.0 Quality insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, approved to ISO 9001: 2000. manufacturing plants are ISO 14001 (Environmentally) and ISO 18001 (Health & Safety) accredited. Guarantees insulated panels are available with the TOTAL Guarantee offering 25 years thermal and structural performance guarantee. Packing Standard Packing KS1000 LS Longspan panels are stacked face up and require turning over during unpacking / erection. Removable hot melt adhesive is laid between each panel. The top, bottom, sides and each end are protected with polystyrene and timber packing and the entire pack is wrapped in polythene. The number of panels in each pack depends on the panel thickness, as shown in the table below. Typical pack height is 1100mm. Panel Core Thickness 80 100 120 140 No. panel/pack (max.) 11 10 7 7 Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. Delivery All deliveries (unless indicated otherwise) are road transport to project site. Off loading is the responsibility of the cladding contractor or installer. Typical Spans Product Reference Typical Single Span (m) KS1000 LS 80 5.0 KS1000 LS 100 6.0 KS1000 LS 120 7.0 KS1000 LS 140 8.0 Notes: These typical spans are based on a design wind pressure and suction of 0.9kN/m 2, for guidance only. Please check exact design wind loads for building (obtained from the project engineer) with the load/span table on page 8. Product Data 7

Structural Unfactored Load/Span Table (use calculated design windload values unfactored) Span Core Load Uniformly Distributed Loads (kn/m 2 ) Condition Thickness Type Span L in metres (mm) 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Single Span 80 Pressure 3.12 2.31 1.73 1.34 1.04 0.81 - - - - - Outer sheet Suction 2.75 1.98 1.44 1.08 0.81 0.61 - - - - - 0.63mm steel 100 Pressure 3.57 3.05 2.41 1.89 1.51 1.20 0.97 0.73 - - - Inner sheet Suction 3.55 2.78 2.10 1.61 1.26 0.98 0.77 0.61 - - - 0.63mm steel 120 Pressure 3.75 3.21 2.80 2.45 1.98 1.61 1.32 1.10 0.92 - - L Suction 3.75 3.21 2.68 2.12 1.72 1.36 1.10 0.88 0.73 - - 140 Pressure 3.75 3.21 2.80 2.45 2.24 2.00 1.66 1.39 1.18 0.99 0.85 Suction 3.75 3.21 2.80 2.34 1.90 1.56 1.31 1.12 0.96 0.81 0.68 Notes: 1. Values have been calculated using the limit state method described in the European recommendations for the design of sandwich panels. (ECCS document No.115 2001). Taking imposed loads, temperature and creep into account. 2. For each value individual and combined load cases with appropriate load factors and temperatures have been considered. These are detailed under Structural Performance in the Building Design Section of the Design & Construction Guide. 3. The table is for dark coloured panels. 4. The following deflection limits have been used: Pressure loading L /100 Suction loading L /100 5. For Intermediate values linear interpolation may be used. 6. The actual wind suction load resisted by the panel is dependant on the number of fasteners used. The fastener calculation should be carried out in accordance with the appropriate standard. For further advice please contact envirocare Technical Services. 7. The allowable steelwork tolerance between bearing planes of adjacent vertical columns is 10mm to NSSS (National Structural Steelwork Specification). 8. Load span tables for the panel specifications not shown are available from the envirocare Technical Services. 8

9 Product Data

Construction Details Vertical Joint Details Option A Detail Panel fasteners at joint only. Number dependent upon design wind suction loadings. 40mm Air seal EPDM bubble gasket 95 x 10mm, Ref: VJ2 Supplied in 25m rolls PIR board insulation with fire rated canister insulation to fill any gaps if required to maintain continuity of insulation AWP joint filler and gun-grade sealant Air seal gun-grade sealant to male joint 4mm diameter butyl rubber sealant (site applied) Option A top hat (roll formed) 30mm deep with 100mm sealed butt straps. Supplied in max. 6000mm lengths 30mm KS1000 LS Longspan TM horizontally laid Snap on cover flashing. Maximum 6000mm lengths 10

Option B Detail Panel fasteners at joint only. Number dependent upon design wind suction loadings 40mm Air seal EPDM bubble gasket 95mm x 10mm, Ref: VJ2 Supplied in 25m rolls PIR board insulation with fire rated canister insulation to fill any gaps if required to maintain continuity of insulation AWP joint filler and gun-grade sealant Air seal gun-grade sealant to male joint 4mm diameter butyl rubber sealant (site applied) Option B top hat (roll formed) 30mm deep with 100mm sealed butt straps. Supplied in max. 6000mm lengths 30mm KS1000 LS Longspan TM horizontally laid Construction Details 11

Vertical Joint Details Option C Detail 10mm Air seal EPDM bubble gasket 95mm x 10mm, Ref: VJ2 Supplied in 25m rolls Panel fasteners at joint only. Number dependent upon design wind suction loadings. 25mm 25mm Site applied fire rated canister insulation AWP joint filler and gun-grade sealant Air seal gun-grade sealant to male joint 15mm 4mm diameter butyl rubber sealant (site applied) 80mm KS1000 LS Longspan TM horizontally laid Option C Shadow Line feature flashing with 100mm sealed butt straps. Supplied in max. 6000mm lengths Option D Detail Air seal EPDM bubble gasket 95 x 10mm, Ref: VJ2 Supplied in 25m rolls 50mm Panel fasteners at joint only. Number dependent upon design wind suction loadings PIR board insulation with fire rated canister insulation to fill any gaps if required to maintain continuity of insulation AWP joint filler and gun-grade sealant Air seal gun-grade sealant to male joint EPDM integral fir tree seal. Supplied in 50m rolls 34mm KS1000 LS Longspan TM horizontally laid Option D extruded aluminium top hat section TH30 30mm deep with 100mm sealed butt straps. Supplied in 6000mm lengths extruded aluminium insert section Ref: IN11. Supplied in 6000mm lengths. 12

Option E Detail Panel fasteners at joint only. Number dependent upon design wind suction loadings 50mm Air seal EPDM bubble gasket 95mm x 10mm, Ref: VJ2 Supplied in 25m rolls PIR board insulation with fire rated canister insulation to fill any gaps if required to maintain continuity of insulation AWP joint filler and gun-grade sealant Air seal gun-grade sealant to male joint EPDM integral fir tree seal. Supplied in 50m rolls Option D extruded aluminium top hat section TH30 30mm deep with 100mm sealed butt straps. Supplied in 6000mm lengths. Note: extruded aluminium sections are supplied mill finished as standard or can be specified polyester powder coated to BS or RAL colours 34mm KS1000 LS Longspan TM horizontally laid extruded aluminium insert section Ref: IN23. Supplied in 6000mm lengths Drip Detail 140mm thick panel Column face KS1000 LS Longspan TM horizontally laid Internal closure flashing with 100mm sealed laps Air seal 9mm x 3mm butyl rubber sealant Canister applied insulation Drip flashing Base channel (Ref: LS BC 140) for full length of panel levelled with packers and fixed to floor slab at 500mm maximum centres Air seal continuous bead of gun-grade sealant Construction Details 13

Drip Detail 80mm thick panel Column face KS1000 LS Longspan TM horizontally laid Internal closure flashing with 100mm sealed laps Air seal 9mm x 3mm butyl rubber sealant Base channel (Ref: LS BC 80) for full length of panel levelled with packers and fixed to floor slab at 500mm maximum centres Canister applied insulation Air seal continuous bead of gun-grade sealant Drip flashing 14

Vertical Joint Layout KS1000 LS Longspan TM horizontally laid Top hat support cleats at 500mm max centres using avex rivets Avex rivets 4mm diameter butyl rubber seal Vertical top hat Top hat fixed to top hat support cleats Snap on cover cap Construction Details 15

Insulated Roof, Wall & Façade Systems Roof Systems KS1000 RW Trapezoidal KS1000 SF Secret Fix KS1000 TS Slate & Tile Support KS500/1000 ZIP Kingzip Standing Seam KS1000 LP Lo-Pitch EnergiPanel KS1000 CR Curved Roof Roof Tile KS1000 FC Box Profile Envirodek Polycarb Rooflight Wall & Façade Systems & 1000 Optimo & 1000 MR Micro-Rib & 1000 EB Euro-Box & 1000 FL Flat & 1000 FL-S Stucco & 1000 MM Mini-Micro & 1000 CX Convex & 1000 WV Wave & 1000 LS Longspan KS1000 RW Trapezoidal KS1000 FC Box Profile EnergiPanel Thermatile Thermabrick Thermastone WoodTherm Wall-Lite Ancillaries Gutters, Tophats & Flashings Limited UK: Telephone: +44 (0) 1352 716100 Fax: +44 (0) 1352 710161 Email: info@kingspanpanels.com Ireland: Telephone: +353 (0) 42 96 98500 Fax: +353 (0) 42 96 98572 Email: sales.ire@kingspanpanels.com Details for the following countries; Australia, Belgium, Czech Republic, France, Germany, Hungary, Netherlands, New Zealand, Norway, Poland, Romania, Slovakia & Sweden can be found by visiting our website www.kingspanpanels.com or our group website www.kingspan.com Care has been taken to ensure that the contents of this publication are accurate, but Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Limited and its subsidiaries accept no liability in respect thereof.