Type: DILM32 10(24V50HZ) Article No.: 277247



Similar documents
Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technicaldata General

Three-phase monitoring relay CM-PFE

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Catalog. Modular DIN rail components Installation contactors

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Technical catalogue. Modular DIN rail components Installation contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Analog signal converters CC-E I/I Current / current isolators

Bimetallic Overload Relay Specifications

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

RM4TG20 three-phase network control relay RM4-T - range V

Manual motor starter MS116

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

38 Series - Relay interface modules A

Thermistor motor protection

Relés e Contatores de Estado Sólido SIRIUS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

38 Series - Relay interface modules A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

R.C.C.B. s two-pole LEXIC

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

PHOENIX CONTACT Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Safety technique. Emergency stop module BO 5988 safemaster

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

49 Series - Relay interface modules A. Features

Redundancy Module QUINT-DIODE/40

E-STOP relays, safety gate monitors

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Manual Motor Starter MS 116 up to 16 A Technical Data

CQM1-SF200/CS1W-SF200

Pluggable interface relays CR-P Pcb relays

Series 8146/5-V37 and Series 8150/5-V37

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

MasterINTERFACE 39 Series - Relay interface modules

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Actuator-Sensor-Interface

Thermal-Magnetic Circuit Breaker M1-..

5SV Residual Current Protective Devices

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

ZS25 Screw Clamp Terminal Blocks Feed-through

Plug and Socket Devices CES 63 A Series 8579

EMR measuring and monitoring relays

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

CompactLogix Power Supplies Specifications

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

MasterINTERFACE 39 Series - Relay interface modules

PSR The compact range Description

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Safety automation solutions

Product and functional description

D-Line Contactors, Overload Relays and Accessories

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Quick Connect. quick - simple - efficient.

Contact expansion modules

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Transcription:

Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50 60 Hz AC 3 400 V Max. rating for three phase motors, 50 60 Hz AC 3 690 V Max. rating for three phase motors, 50 60 Hz AC 4 230 V Max. rating for three phase motors, 50 60 Hz AC 4 400 V Max. rating for three phase motors, 50 60 Hz AC 4 690 V P kw 10 P kw 15 P kw 17 P kw 4 P kw 7 P kw 10 General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations 10 6 10 DC operated Operations 10 6 10 Operating frequency, mechanical AC operated Operations/h 5000 DC operated Operations/h 5000 Climatic proofing Ambient temperature Open C 25/60 Enclosed C 25/40 Storage C 40/80 Damp heat, constant, to IEC 60068 2 78 Damp heat, cyclical, to IEC 60068 2 30 1

Mechanical shock resistance (IEC/EN 60068 2 27) Half sinusoidal shock, 20 ms Main contacts Make contact g 10 Auxiliary contacts Make contact g 7 Break contact g 5 Protection type Protection against direct contact when actuated from front (IEC 536) Weight IP00 AC operated kg 0,42 DC operated kg 0,48 Terminal capacity Main cable Solid mm 2 1 (0.75 16) 2 (0.75 10) Flexible with ferrule mm 2 1 (0.75 16) 2 (0.75 10) Stranded mm 2 1 16 Solid or stranded AWG 18 6 Anschlussschraube Hauptleiter Tightening torque Nm 3 Terminal capacity Control circuit cables Solid mm 2 1 (0.75 4) 1 (0.75 4) Flexible with ferrule mm2 Solid or stranded AWG 18 14 Anschlussschraube Hilfsleiter M3.5 Tightening torque Nm 1.2 Tool Main cable Pozidriv screwdriver Size 2 Standard screwdriver Control circuit cables Pozidriv screwdriver Size 2 Standard screwdriver Terminal capacity Control circuit cables mm mm Finger and back of hand proof M5 1 (0.75 2.5) 2 (0.75 2.5) 0.8 5.5 1 6 0.8 5.5 1 6 Solid mm 2 0.75 2.5 Flexible mm 2 0.75 2.5 Flexible with ferrule mm 2 0.75 2.5 Solid or stranded AWG 18 14 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 2

Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree Rated insulation voltage AC U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 440 between the contacts V AC 440 Making capacity (cos Õ to IEC/EN 60947) up to 690 V Breaking capacity III/3 A 384 220/230 V A 320 380/400 V A 320 500 V A 320 660/690 V A 180 Component lifespan AC 3/AC 4 Tripping characteristics Maximum operating frequency AC 1; 400 V I e Ops/h 800 AC 3; 400 V I e Ops/h 800 AC 4; 400 V I e Ops/h 300 Short circuit rating Short circuit protection Maximum fuse Type 2 coordination 400 V gg/gl 500 V A 63 690 V gg/gl 690 V A 35 Type 1 coordination 400 V gg/gl 500 V A 125 690 V gg/gl 690 V A 63 AC AC 1 duty conv. therm. current 3 pole 50 60 Hz open at 40 C I th A 45 at 50 C I th A 43 at 55 C I th A 42 at 60 C I th A 40 Enclosed I th A 36 Conventional free air thermal current, 1 pole open I th A 85 Enclosed I th A 80 AC 3 duty Rated operational current AC 3 open, 50 60 Hz, 3 pole 3

220/230 V I e A 32 240 V I e A 32 380/400 V I e A 32 415 V I e A 32 440V I e A 32 500 V I e A 32 660/690 V I e A 18 Motor rating 220/230 V P kw 10 240V P kw 11 380/400 V P kw 15 415 V P kw 19 440 V P kw 20 500 V P kw 23 660/690 V P kw 17 AC 4 duty Rated operational current AC 4 open, 50 60 Hz, 3 pole 220/230 V I e A 15 240 V I e A 15 380/400 V I e A 15 415 V I e A 15 440 V I e A 15 500 V I e A 15 660/690 V I e A 12 Motor rating 220/230 V P kw 4 240 V P kw 4,5 380/400 V P kw 7 415 V P kw 7,5 440 V P kw 8 500 V P kw 9 660/690 V P kw 10 DC of three phase capacitors open DC 1 operation 60 V I e A 40 110 V I e A 40 220 V I e A 40 440 V I e A 2,9 DC 3 operation 60 V I e A 40 110 V I e A 40 220 V I e A 25 440 V I e A 0,6 DC 5 operation 4

60 V I e A 40 110 V I e A 40 220 V I e A 25 440 V I e A 0,6 Current heat loss (3 pole) Current heat loss at I th W 12,1 Current heat loss at I e to AC 3/400 V W 6,1 Impedance per pole m& 2 Magnet systems Voltage tolerance AC operated AC operated Pick up U c 0,8 1,1 Drop out voltage AC operated Drop out voltage AC operated Abfall U c 0,3 0,6 DC operated DC operated Pick up U c 0,7 1,2 DC operated DC operated Abfall U c 0,15 0,6 Power consumption of the coil in a cold state and 1.0 U c 50 Hz Pick up VA 50 50 Hz Pick up W 40 50 Hz Sealing VA 8 50 Hz Sealing W 2,4 60 Hz Pick up VA 62 60 Hz Pick up W 50 60 Hz Sealing 9,1 60 Hz Sealing VA 2,7 50/60 Hz Pick up VA 50/60 Hz Pick up W 50/60 Hz Sealing VA 50/60 Hz Sealing W DC operated Pick up W 12 at 24 V DC operated Sealing W 0.5 at 24 V 60 54 48 43 9,5 7,9 2,8 2,4 Duty factor % DF 100 Switching times at 100 % U c (approximate values) Main contacts AC operated Closing delay ms 25 Opening delay ms 25 DC operated Closing delay ms 60 Opening delay ms 15 5

Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference to EN 60947 1 Interference immunity to EN 60947 1 Mounting position, AC and DC operated Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL C2005GB INT V3.0 6