HARDWARE SUBRAID. SUBRAID MAX II STD rebuilds backup system



Similar documents
2» 10» 18» 26» PD »

ARAID 3500 / S3500 User s Manual

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

Installation Manual (AZ-SBC98) SATA SUBRAID V3

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

BounceBack Server Solution Reference Guide

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

**Please read this manual carefully before you use the product**

User s Manual. Home CR-H BAY RAID Storage Enclosure

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

USER S MANUAL.

Intel Rapid Storage Technology

SATA II 4 Port PCI RAID Card RC217 User Manual

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

XL-RAID-SATA Data Backup System. User s Guide

ACT-DASR101 Disk Array Series products

This chapter explains how to update device drivers and apply hotfix.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

How To Play Your Hard Disk Drive On A Mini Hard Disk (Ios) Or Usb (Miii) With A Hard Disk 2 (I2) Or Ios 2 (Mini Usb) With An External Hard Drive (Mini) Or Mini

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Mini-2Bay RAID Subsystem, (RAID 0,1 selectable) w/ combo 1*USB 2.0 Connector and 1*eSATA (SATAII shielding) Connector User s Manual

USB3.0 Docking Station. User Manual (DA-70546)

FUSION R400 RAID USB 3.0

Cool USB 2.0/eSATA to SATA Docking Duplicator Quick Installation Guide

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

NVIDIA RAID Installation Guide

PCIe SATA 6G Raid Card

ESATA PCI CARD. User s Manual

How To Set Up A Hard Disk Drive With A Rkd (Sr5650) And A Hard Drive (Srs5650-Wbs1/Sb2)

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

Intel Matrix Storage Manager 8.x

SATA 150 RAID. user. Model MAN UM

Guide to SATA Hard Disks Installation and RAID Configuration

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering

PCI Express SATA / esata 6Gb/s RAID Card User Manual

Dual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan. User s Manual

Mini-EPic System of RAID

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

SATA 6G PCIe Card User Manual Model: UGT-ST622

RAID installation guide for Silicon Image SiI3114

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

Version : 1.0. SR3620-2S-SB2 User Manual. SOHORAID Series

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

Mini-EPICa SATA II-to-SATA II RAID SUBSYSTEM

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

HQP-1072 Series System User Guide

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

1. User Safety Instructions

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, v1.0

5-BAY RAID STATION. Manual

Guide to SATA Hard Disks Installation and RAID Configuration

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

DF to-2 SATA II RAID Box

PCI SATA Controller Card Model: SY-PCI40010

FANTEC MR-35DU3-6G USER MANUAL

Configuring ThinkServer RAID 100 on the TS140 and TS440

Configuring ThinkServer RAID 100 on the Lenovo TS130

Guide to SATA Hard Disks Installation and RAID Configuration

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

AMD RAID Installation Guide

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

VIA RAID Installation Guide

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

AMD SP5100 Dot Hill SATA RAID Users Manual V100

This user guide describes features that are common to most models. Some features may not be available on your computer.

Dynamode External USB3.0 Dual RAID Encloure. User Manual.

USB to IDE SATA Standalone Hard Drive Duplicator Dock StarTech ID: UNIDUPDOCK

Manual IB-3620 Series

VT8237 SATA RAID User Manual

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

HDD Docking Station for 2.5 /3.5 SATA HDD with esata Connector User Manual

FASTA-2e 2 Port PCI-Express SATA 3G Card. User Manual

Serial ATA to Serial ATA

VIA / JMicron RAID Installation Guide

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.

Hard Disk Drives and RAID

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives. User Manual August 18, v1.0

Intel ESB2 SATA RAID Setup Guidelines

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Serial ATA RAID PCI Card

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration

2.5" XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (X Series) 1.

2big Quadra ENTERPRISE CLASS. Professional 2-Disk RAID DESIGN BY NEIL POULTON. esata 3Gb/s FireWire 800 & 400 USB 2.0

2 Bay FireWire 800/400/USB RAID Solution RAID 0, RAID 1, & JBOD. User Manual

User Manual. 2 Bay Docking Station

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

Intel RAID SSD Cache Controller RCS25ZB040

Transcription:

SUBRAID MAX II STD rebuilds backup system Introduction SUBRAID MAX II STD rebuild backup system - A Real-Time-BACKUP device designed for Enterprises, Schools, and Personal use. It provides a solution for low cost, high performance, redundant Disk And backup function Functions and Features Hardware Raid System: Build in 32 bit RISC CPU with advance RAID core engine. Windows or Linux version: Motherboard bios and O/S detect Sub-raid as single hard drive. No software drives needed. Raid 1 Rebuild:. Compiles with RAID 1 data mirror function. Data Assurance: True data Verify. Read and compare master and back up data. Convenience backup: System under normal operating condition, if a backup hard disk drive being replaced. MRS SUB-RAID will automatic rebuild content of the master drive to the new backup hard disk drive as instructed. Durable and Reliable: Industrial grade server product with specific cooling design. Reliable raid controller design. High Performance: Fast valid data mirroring with SATA throughput performance. MRS Sub-raid is an independent sub-system that does not require system resource. Error Indication: When one hard disk drive crashes, your system would work as usual. High Capacity: 48 bit LBA support. Hard disk drive capacity support 1TB hard drive or above. Easy Maintenance: Support hot swap hard drive. End-user can handle normal errors and reduce IT support loading. MRS Sub-raid able to provide an off site back up drive copy with an extra hard drive and Sub-raid tray. Host Compatibility: Supports native SATA standard for onboard I/O or with MRS PCI-E SATA controller. Power requirement: +12V. Hot swappable trays: special design tray board for reliable hot swap and easy replacement. Security: Keys for security and power source functions. System requirements Page 1 of 7

Standard Native Serial ATA. O.S. supports(requires no drivers): Windows 7, Windows VISTA, Windows NT/2000/XP,Windows 2003, Windows 2008. Mac, Linux and VM Ware.. Unpacking SUBRAID MAX STD rebuild backup system 1. Unpack internal SUBRAID MAX STD system from the carton 2. Included for easy integration: - SUBRAID system with two hot swappable trays -Two keys for tray lock -SATA (onboard) to E-SATA data cable Hardware installation To install the SUBRAID MAX STD rebuild backup system, please follow these steps: 1. Turn off the power of computer. 2. Remove the cover from the computer case. 3. Put SUBRAID MAX STD rebuild backup system into the 2 conjunct 5.25 bays space and secured it properly. 4. Connect DC cable from power supply to SUBRAID MAX STD 5. Connect SATA-ESATA cable from motherboard to SUBRAID MAX STD 6. Cover computer case. Install one hard drive into upper bay as MASTER drive. You have now completed the installation of the SUBRAID MAX STD and ready for O/S installation. Page 2 of 7

SUBRAID MAX STD FRONT PANEL H.D. ACCESS LED LOGO KEY MASTER MASTER Red Button funstions 1. Press to stop Buzzer Alarm. 2. Master: OK, Backup:OK Press and hold red button till LCD shown Verify to start DATA verification. KEY BACKUP LCD BACKUP For system upgrade Be sure you do have a good back up copy of the drive or disk image of the drive before proceeding. (MRS TECHNOLOGIES is neither liable nor responsible for any unexpected outcome) After Sub-Raid Max STD been installed properly. Install original hard drive onto one of the tray. Plug the hard drive into the master bay. Turn key lock to on. Start system as normal. When Sub-raid MAX STD LCD display MASTER:OK, BACKUP:WAIT, system is ready. Create BACKUP hard drive copy - After O/S installed and system been configured properly. -Put second hard drive into BACKUP tray - Insert into SUBRAID MAX STD BACKUP bay - Turn the BACKUP key lock on - The LCD display will show from "" to "" - Then start hard drive mirror rebuild processing. Page 3 of 7

- After rebuild processing completed, LCD will show " and " - When and If users require extra assurance for the back up drive data integrity. Press and hold on the front red button. Wait for VERIFY function been activated. Then release the red button. VERIFY : XXXXG Based on the master hard drive, Sub-Raid STD will read from both drive and verify each used sector. - When completed, LCD will display: Create off site back up copy or extra copy for safety precaution - Turn the BACKUP key lock off - Wait for LCD display changed from "" to "" - When LCD display "". Indicated it s safe to pull out BACK UP drive. The good copy can be for off site or extra rotated back up drive. (The content will only be updated to the second you turn BACKUP KEY TO OFF.) - And then put another backup drive into the BACKUP bay - Turn the BACKUP key lock on - The LCD display will show "" to "" - Then starting hard drive mirror rebuilds processing. DONE : XXXXG XXX% Page 4 of 7

- When completed, LCD will display, "" WORKING STATUS 1. The LCD shows both hard drives were unlock and SUBRAID system LCD shows: MASTER: OFF At such time, SUBRAID system does not provide DC power to MASTER and BACKUP hard drive. MRS SUBRAID STD will not provide MASTER and BACKUP hard drive Read/Write function. 2. When MASTER hard drive locked and system at good working condition, BACKUP hard drive unlocked, the SUBRAID STD system LCD shows: At such time, SUBRAID STD system will provides MASTER hard drive read/write function but no data redundancy. 3. When MASTER hard drive locked and system at good working condition, plug in BACKUP hard drive with smaller size hard drive and locked. SUBRAID STD LCD shows: MASTER: ON BACKUP: TOO SMALL When SUBRAID STD shown BACKUP: TOO SMALL indicated BACKUP Page 5 of 7

Hard drive size too small for raid 1 mirroring. Backup drive for raid 1 needed to be equal to or bigger than the master drive. 4. When MASTER and BACKUP shown both hard drives were in good condition, the SUBRAID system LCD shows: SUBRAID STD system will provide read/write function. Online back up functioning. 5. When MASTER hard drive shown OK, BACKUP hard drive was not working properly. The SUBRAID STD can not detect BACKUP hard drive. The SUBRAID system LCD shows: BACKUP: HDD FAIL? At such time, the SUBRAID MAX system still provides read/write function, but the RAID function is no longer existed. Online back up not available. Please unlock and replace a new hard disk on BACKUP bay, relock tray, SUBRAID will auto start the rebuilding. The SUBRAID system LCD shows: 6. During mirroring rebuild. MASTER hard drive suddenly failed, BACKUP hard drive has not been completely finish rebuild the SUBRAID system LCD shows: (Chances for this to occur are very rare. But it is possible. That s why we strongly recommend to swap drives after normal office hours and using 3 hard drives configuration.) MASTER: FAIL PLEASE REPLACE IT At such time, the SUBRAID STD system will stop and wait for replacing MASTER hard drive. If you are using 3 drives configuration. Replace MASTER hard drives, unlock BACKUP hard drive then restart system. This master drive s data will be as updated as the last time you swap this drive. SUBRAID system LCD shows Page 6 of 7

7. During rebuilding, MASTER hard drive shown normal, BACKUP hard drive failed. SUBRAID system LCD shows: BACKUP: HDD FAIL? At such time, the SUBRAID MAX system still provides read/write function, but the RAID function is no longer existed. Online back up not available. Replace BACKUP drive, SUBRAID will auto start the rebuilding. 8. MASTER and BACKUP hard drives were good and mirroring been completed. MASTER hard drive failed. SUBRAID system LCD shows: MASTER: HD Fail At such time, SUBRAID STD system provides read/write function. Real time BACKUP function is no longer available. As soon as you can, Power down system, Unlock, removes and replaces the failed hard drive. Move the working BACKUP DRIVE TO UPPER BAY AS MASTER DRIVE. Power on and boot system, check system configuration and data files. Plug in the new BACKUP drive, SUBRAID will auto start the rebuilding. SUBRAID system LCD shows Plug in the new BACKUP drive and lock on, SUBRAID will auto start the rebuilding. SUBRAID system LCD shows Page 7 of 7