EX-3516 4-Port SATA3 RAID/HyperDuo PCIe(x2) Card



Similar documents
PCIe SATA 6G Raid Card

PCI Express SATA / esata 6Gb/s RAID Card User Manual

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

NVIDIA RAID Installation Guide

RAID installation guide for ITE8212F

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

Encore SATA2 RAID PCIe Card

Intel ESB2 SATA RAID Setup Guidelines

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

Intel Rapid Storage Technology

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

Serial ATA RAID PCI Card

AMD RAID Installation Guide

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.


AMD RAID Installation Guide

Intel Matrix Storage Manager 8.x

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

VIA RAID configurations

6-Port SATA II 150 PCI Host Card w/raid

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

Guide to SATA Hard Disks Installation and RAID Configuration

RAID Option Installation

SATA II 4 Port PCI RAID Card RC217 User Manual

VIA / JMicron RAID Installation Guide

RAID installation guide

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

Ultra ATA 133 RAID PCI Pro

The motherboard supports the following SATA RAID solutions:

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

AMD RAID Installation Guide

VT8237 SATA RAID User Manual

Promise FastTrak 100-Lite RAID Controller

Guide to SATA Hard Disks Installation and RAID Configuration

Marvell SATA3 RAID Installation Guide

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

Serial ATA RAID PCI. User's Manual

English. Configuring SATA Hard Drive(s)

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

VIA RAID Installation Guide

Configuring ThinkServer RAID 100 on the Lenovo TS130

PCI SATA + PATA Raid Card

SATA 150 RAID. user. Model MAN UM

Guide to SATA Hard Disks Installation and RAID Configuration

PCI ATA 133 RAID Controller Card. User Manual

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

RAID configuration and driver installation guide

How To Use A Raid

Configuring ThinkServer RAID 100 on the TS140 and TS440

RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

SATA II PCIe RAID Quick Installation Guide

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

DF to-2 SATA II RAID Box

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Serial ATA 4-Channel RAID Quick Installation Guide

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

User manual Ver: 2.0. SATA Channel PCI RAID Card

ESATA PCI CARD. User s Manual

- 1 - Model: (SATA to USB+Hub+1394a) Code Description: S---SATA Harddisk. ES---ESATA Interface. U---USB2.0 Interface. F---IEEE1394 Interface

Dynamode External USB3.0 Dual RAID Encloure. User Manual.

RocketRAID User, s Manual. Revision: 1.0 Date: Sept HighPoint Technologies, Inc.

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

Using ATI Array Management Software (WebPAM)

Low Profile Ultra ATA-133 RAID PCI Host

RocketStor SMART RAID

SERIAL ATA HOST CONTROLLER CARD USER MANUAL SATA R SATA I WARNING

PCI SATA Controller Card Model: SY-PCI40010

Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs

This user guide describes features that are common to most models. Some features may not be available on your computer.

LSI Software RAID Configuration Utility

Guide to SATA Hard Disks Installation and RAID Configuration

2S RS232 Multi Serial PCI Card Installation Guide

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

esata 6G RAID PCIe 2.0 Controller Card

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

This user guide describes features that are common to most models. Some features may not be available on your computer.

USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM

User s Manual. Home CR-H BAY RAID Storage Enclosure

1-Port R422/485 Serial PCIe Card

SATA II PCIe RAID Quick Installation Guide

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

RAID OPTION ROM USER MANUAL. Version 1.6

4-1-4 Serial ATA SATA. A. Intel ICH8R (1) SATA (1) SATA (2) BIOS SATA (3) RAID BIOS RAID (4) SATA (5) SATA

Acer RAID Ready Systems With Intel Matrix storage Manager User's Guide. Acer Incorporated. Version: v1.1 Date: August, 2007

Intel ICH5R Serial ATA RAID. Quick User s Guide

RocketRAID mini-sas 6G HBA Series Data RAID. Installation Guide

IDE2410 ATA-100 IDE RAID Card. Version 1.0

FASTTRAK USER MANUAL TX2200, TX2300. Version 3.2

Transcription:

EX-3516 4-Port SATA3 RAID/HyperDuo PCIe(x2) Card Thank you for purchasing this 4-Port SATA3 RAID/HyperDuo PCIe Card. It is designed to support up to 4 SATA3 ports in RAID 0 and RAID 1, RAID 0+1 modes and HyperDuo modes for SSD (Solid State Drive) and hard drive combination. It supports SATA3 SSD and hard drives with up to 6.0Gbps data rate. It is an ideal solution to add new SATA3 SSD and hard drives for your system. Features: 1. Introduction Supports 1-lane 5.0Gb/s PCI Express Gen.2 Data Transfer Rate Built-in 4 Internal SATA3 Ports Supports RAID 0,1, 0+1 and HyperDuo (Safe or Capacity) Modes Supports Windows based RAID GUI (Marvell Storage Utility, MSU) Supports SATA3 transfer rate up to 6.0Gb/s (600Mbytes/sec) Supports RAID 1 Rebuild by BIOS Setup Utility Supports Windows 2003, 2008, XP, Vista and Win 7 2. Board Layout J2: LED Connector JP1 BIOS Enable/Disable Jumper J1: SATA3 Ports UP: Port 1 Down: Port 0 J3: SATA3 Ports UP: Port 3 Down: Port 2 1

3. Jumper Settings The JP1 can be used to disable the BIOS on the card for some critical applications, please leave the jumper at ENA all the time. JP1: BIOS Enable/Disable Jumper DIS ENA BIOS Enabled: Jumper Installed at ENA (Default) DIS ENA BIOS Disabled: Jumper Installed at DIS 4. Hardware Installation 1. Power down the computer, remove the computer cover. 2. Choose an unused PCI Express bus slot (2, 4, 8 or 16 lane), unscrew and remove the slot cover. 3. Place the SATA3 RAID PCIe Card into the slot. Carefully press the board into the slot until it seats firmly. 4. Secure the SATA3 RAID PCIe Card with the slot cover screw. 5. Install the SATA cables from the SATA connectors to your SATA devices. 6. Carefully reinstall the computer cover. Insert and tighten the computer cover screws. 7. Power up the PC and observe the monitor. The BIOS lists all Serial ATA devices attached to the SATA3 RAID/HyperDuo PCIe Card. For example: 2

If the information displayed on your monitor is correct (the installed devices are listed with the correct device name, etc.), congratulations! You have successfully installed the SATA3 RAID/HyperDuo PCIe Card in your computer. If you want to configure your RAID drives, press and hold the 2 keys, Ctrl and M, to enter the BIOS Setup Utility for this card. You can configure the SATA RAID or HyperDuo modes in the BIOS Setup. 5. RAID and HyperDuo Modes 5.1 RAID Modes This chapter will help you to know the RAID and HyperDuo modes supported by the SATA3 RAID/HyperDuo PCIe Card. 5.2 Non-RAID mode (Single Disk Mode) This mode is the Single Disk mode. Each disk drive will be treated as one disk volume in the operating system. 5.3 Striping (RAID 0) Read and write sectors of data interleaved between multiple drives. When any disk member fails, it affects the entire array. Performance is better than a single drive since the workload is balanced between the array members. This array type is for high performance systems. Identical drives are recommended (but not necessary, if the sizes differ, it will truncate the bigger drive so the sizes match, it will cause a waste) for performance as well as data storage efficiency. The disk array data capacity is equal to the number of drive members times the smallest member capacity. 3

Write data Streams.. 4, 3, 2, 1 1 3 : : Stripe member 1 Read data Streams.. 4, 3, 2, 1 5.4 Mirroring (RAID 1) 2 4 : : Stripe member 2 Writes duplicate data on to a pair of drives while reads are performed in parallel. The RAID controller performs reads using advanced data handling techniques that distribute the workload in a more efficient manner than using a single drive. When a read request is made, the RAID controller selects the drive positioned closest to the requested data, then looks to the idle drive to perform the next read access. If one of the mirrored drives suffers a mechanical or did not respond, the remaining drive will continue to function. Write data Streams.. 4, 3, 2, 1 1 2 3 4 1 Mirror member 1 (Original) Read data Streams.. 4, 3, 2, 1 1 2 3 4 2 Mirror member 2 (Mirror) 5.5 Striping/Mirroring (RAID 0+1, or RAID 10) A combination of both above array types. It can increase performance by reading and writing data in parallel while protecting data with duplication. With a four-drive disk array, 4

two pairs of drives are striped. Each pair mirrors the data on the other pair of striped drives. The data capacity is similar to a standard mirroring array with half of total capacity dedicated for redundancy. 5.6 HyperDuo The HyperDuo mode in combination with a SATA HDD and a SSD, offering a breakthrough embedded technology for new-generation 6Gb/s SATA controllers, enabling 80 percent of the performance of a solid state drive (SSD) at one-third the cost. Configured with one hard drive and one SSD, HyperDuo uses intelligent algorithms to automatically migrate hot data to the SSD, while enabling all data to be safely stored on a larger capacity SATA HDD. HyperDuo enables two modes: Safe Mode and Capacity Mode. Both modes automatically identify LBA ranges across both the SSD and HDD so that the user experience is exactly the same. By allowing consumers to view the same single drive volume (eg. Data (D:) ) as they do today, HyperDuo requires no behavioral changes by consumers to maximize simplicity and eliminates user error. 5.6.1 HyperDuo: Safe Mode Safe Mode provides optimal data protection by mirroring data from the SSD to the hard disk for maximum resiliency. 5

5.6.2 HyperDuo: Capacity Mode Capacity Mode augments SSD and HDD capacity for the most cost-effective configuration. 6. Configuring a SATA Disk Array Turn on your computer and press <Ctrl> and <M> keys to enter BIOS Setup during the POST (Power-On Self-Test). Please check the Help field at the bottom of the screen for proper operations. 6

6.1 Create a Disk Array: Under Free Physical Disks, use the <Space> key to select the hard drives to be included in the RAID array. The selected hard drive will be marked with an asterisk (*). After selecting the hard drives, press <Enter> to proceed. To further configure the disk array, use the up or down arrow key to move the selection bar to select an item in the right block of the screen and press <Enter>. Set the required items in sequence and press <Enter> after each step: 1. RAID Level: Select a RAID level. Options include RAID 0 (Stripe) and RAID 1 (Mirror). 2. Stripe Size: Select the stripe block size. Options include 32 KB and 64 KB. 3. Gigabyte Rounding: Select whether to permit the installation of a replacement drive that is smaller than the failed drive when performing a RAID 1 rebuild. Options include None, 1G, and 10G. 4. Quick Init: Select whether to quickly erase old data on the hard drives when creating the array. 5. VD Name: Enter an array name with 1~10 letters (letters cannot be special characters). 6. Next: After completing the settings above, move to Next and press <Enter> to begin creating the array. When prompted to confirm whether to create this array, press <Y> to confirm or <N> to cancel. 7

7. When completed, you can see the new array under Topology\Virtual Disks. 8. Save the Settings and Exit. After you complete the RAID configuration and before you exit the configuration screen, be sure to press <F10> in the main screen. Press <Y> to confirm or <N> to cancel. 9. Now, you may proceed to create the SATA driver diskette (for AHCI mode) and the installation of the SATA driver and operating system 6.2 Delete the Disk Array: To deleted the existing array, select the array on the main menu (example: VD 0: New_VD) and press <Enter> to display the Delete option. Press <Enter>. When prompted, press <Y> to confirm or <N> to cancel. 7. Installing RAID Drivers and GUI (MSU) With the Marvell Storage Utility (RAID GUI), you can setup a disk array or view the current array status in the operating system. Before installing the MSU utility, you have to install the drivers first, the Windows Hardware Installing Wizard will invoke the drivers when you first time power up the system with the RAID card installed in the PCIe slot, you need to insert the supplied driver CD (folders as the following picture), and browse to the correct folder to complete the installation. For 64-bit Windows Platforms Please follow the following steps: For 32-bit Windows Platforms 1. While Windows Hardware Wizard asking for the drivers, browse to the correct folder \SATA3\88SE9230\Drivers\amd64 (or i386 for 32-bit Windows) to install the RAID drivers 8

2. Reboot the system to let the drivers take effect. 3. Run the RAID GUI installer (\SATA3\88SE9230\Utility\MRUSetup.exe) to install the RAID Utility. Note: After the installation, you must login the utility with the same account name and password that you use to login the operating system. If you did not set the account password before, click Login to enter the Marvell Storage Utility (MSU) directly. Note: Please refer to the manual file of Marvell Storage Utility (MSU) on the CD (in the same folder as the drivers) for more detail operations. 9

8. Troubleshooting Tips Q: What should I do if my disk array is broken? If a disk array is broken, please don t open the computer case immediately to correct the problem before you backup all your important data. It s because you are most likely to make a mistake in this abnormal condition. PLEASE BACKUP YOUR DATA FIRST! If your array is in RAID 1 mode or HyperDuo Safe mode, that means your system is still running in the critical condition instead of dead. If you backup your data by removable drives or network solution, you will have a copy of up-to-date data away from this computer. Then you are safe to correct the RAID problems even you open the computer case or change the hardware settings. Some people destroyed the data on the good drive by accident mistake when they are changing drive or cables or modes. And they lost their important data since they did NOT backup them first! For RAID 0 mode, please always backup the data since you will lost all data when the array is broken. Some broken array is caused by the connection problems. To see if it is the problem, please power off your computer and check the cable connections between the RAID card and SSD or hard drives. Or change a new power or SATA cable, then power on the computer again. These may bring the broken array back to normal if the root cause is the connection problem. If the above actions don t work, then it may be the SSD or hard drive problem. Please replace the defect drive with a good one. The RAID card then will detect the new drive and rebuild the broken array (RAID 1). Please note that you cannot rebuild a broken RAID 0 in any case. 10