The motherboard supports the following SATA RAID solutions:
|
|
|
- Berenice Armstrong
- 10 years ago
- Views:
Transcription
1 Setting up RAID The motherboard supports the following SATA RAID solutions: LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Technology enterprise SCU / SATA Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). Marvell RAID Utility with RAID 0, RAID 1, and RAID 10 support. RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. RAID 1E (Enhanced RAID 1) has a striped layout with each stripe unit having a secondary (or alternate) copy stored on a different disk. You can use three or more hard disk drives for this configuration. RAID 10 is data striping and data mirroring combined without parity (redundancy data) having to be calculated and written. With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and three new drives for this setup. RAID 5 stripes both data and parity information across three or more hard disk drives. Among the advantages of RAID 5 configuration include better HDD performance, fault tolerance, and higher storage capacity. The RAID 5 configuration is best suited for transaction processing, relational database applications, enterprise resource planning, and other business systems. Use a minimum of three identical hard disk drives for this setup. If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support DVD to a floppy disk before you install an operating system to the selected hard disk drive. Please refer to chapter 2 for how to select the RAID configuration utility. Move the jumper to choose between LSI MegaRAID and Intel Rapid RAID. Workstation W60 Rev3 RAID Manual Page 1
2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. Install the SATA hard disks into the drive bays following the instructions in the system user guide. 2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. 3. Connect a SATA power cable to the power connector on each drive. Setting the RAID item in BIOS You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA hard disk drives attached to the SATA connectors supported by Intel C602 chipset. To do this: 1. Enter the BIOS Setup during POST. 2. Go to the Advanced Menu > PCH SATA Configuration, then press <Enter>. 3. Set SATA Mode to [RAID Mode] 4. Press <F10> to save your changes and exit the BIOS Setup. Refer to Chapter 4 for details on entering and navigating through the BIOS Setup. RAID configuration utilities Depending on the RAID connectors that you use, you can create a RAID set using the utilities embedded in each RAID controller. For example, use the LSI Logic Embedded SATA RAID Setup Utility or the Intel Rapid Storage Technology if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel C602 chipset. Refer to the succeeding section for details on how to use the RAID configuration utility. Workstation W60 Rev3 RAID Manual Page 2
3 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility: 1. Turn on the system after installing all the SATA hard disk drives. 2. During POST, the LSI MegaRAID software RAID configuration utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Press <Ctrl> + <M> to enter the utility. LSI MegaRAID Software RAID BIOS Version A R LSI SATA RAID Found at PCI Bus No:00 Dev No:1F Device present at Port 0 ST AS MB Device present at Port 1 ST AS MB Device present at Port 2 ST AS MB Device present at Port 3 ST AS MB Press Ctrl-M or Enter to run LSI Software RAID Setup Utility. The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled. The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference. When you create RAID sets with the LSI MegaRAID software RAID configuration utility, the boot priority of the SATA optical drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD. 3. The utility main window appears. Use the arrow keys to select an option from the Management Menu and then press <Enter>. Refer to the Management Menu descriptions on the next page. At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level. Management Menu VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Workstation W60 Rev3 RAID Manual Page 3
4 Menu Description Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive Allows you to initialize the virtual drives of a created RAID set Allows you to initialize virtual drives or change the virtual drive parameters Allows you to rebuild failed drives Allows you to check the data consistency of the virtual drives of a created RAID set Creating a RAID set The LSI Software RAID Configuration Utility allows you to create a RAID 0, RAID 1, or RAID 10 set using two types of configurations: Easy and New. In Easy Configuration, the virtual drive parameters are set automatically. In New Configuration, you manually set the virtual drive parameters. Using Easy Configuration To create a RAID set using the Easy Configuration option: 1. From the Management Menu, select > Easy Configuration, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive Defines Physical Arrays. An Array Will Automatically Become A VD Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Workstation W60 Rev3 RAID Manual Page 4
5 2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow keys to select the drives you want to include in the RAID set, and then press <Space>. When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. Management Menu Easy Configuration - ARRAY SELECTION MENU PORT # 0 ONLIN A ONLIN A READY 3 READY Port # 2 DISK 74.74GB HDS728080PLA C05 SPACE-Sel,ENTER-EndArray,F10-,F2-Drive Info,F3-Virtual Drives,F4-HSP The information of the selected hard disk drive displays at the bottom of the screen. You need at least two identical hard disk drives when creating a RAID 1 set. You need at least four identical hard disk drives when creating a RAID 10 set. 3. Select all the drives required for the RAID set, and then press <F10> to configure array setting. 4. Press <Space> to select the configurable array. Management Menu Easy Configuration - ARRAY SELECTION MENU Select Configurable Array(s) PORT # A-0 SPAN-1 0 DNLIN A DNLIN A00-01 Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10- Esc-Quit Workstation W60 Rev3 RAID Manual Page 5
6 5. Press <F10> again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Virtual Drive 0 RAID = 1 Units= MB Size = MB DWC = Off RA = On Accept SPAN = NO Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 6. Select RAID from the Virtual Drive sub-menu, and then press <Enter>. 7. Select the RAID level from the menu, and then press <Enter>. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Virtual Drive 0 RAID Level RAID = 1 RAID 0 Units= MB RAID 1 Size = MB DWC = Off RA = On Accept SPAN = NO Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Workstation W60 Rev3 RAID Manual Page 6
7 8. Select Units from the Virtual Drive sub-menu, and then press <Enter>. 9. Select the units for virtual drive size from the menu, and then press <Enter>. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Select Units For VD Size MB Virtual Drive 0 GB RAID = 1 TB Units= MB Size = MB DWC = Off RA = On Accept SPAN = NO Select Units For VD Size Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 10. When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual Drive menu, and then press <Enter>. When creating a RAID 0 set, proceed to step Select On to enable the Disk Write Cache setting, and then press <Enter>. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Change DWC Off On Virtual Drive 0 RAID = 1 Units= MB Size = MB DWC = Off RA = On Accept SPAN = NO Disk Write Cache Setting Of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Enabling DWC can improve the performance, but with the risk of data loss. Workstation W60 Rev3 RAID Manual Page 7
8 12. When finished setting the selected virtual drive configuration, select Accept from the menu, and then press <Enter>. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Virtual Drive 0 RAID = 1 Units= MB Size = MB DWC = Off RA = On Accept SPAN = NO Accept This VD Configuration And Go To Next VD Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10- Esc-Quit 13. Follow step 2 to 12 to configure additional virtual drives. 14. Press <Esc> to finish RAID configuration. When prompted to save configuration, select Yes from the menu, and then press <Enter>. Configuration Menu Save Configuration? Easy Configuration Yes Management Menu New Configuration No View/Add Configuration Clear Configuration Virtual Drive(s) d LD Select RAID Boot Drive Size #Stripes StripSz Status GB 2 64 KB ONLINE Select Yes Or No Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Workstation W60 Rev3 RAID Manual Page 8
9 Using New Configuration When a RAID set already exists, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option 1. From the Management Menu, select > New Configuration, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive Clear Existing Configuration And Start A New Configuration Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2. Follow step 2 to 9 of the previous section: Using Easy Configuration. 3. Select Size from the Virtual Drive menu, and then press <Enter>. 4. Key-in the desired virtual drive size, and then press <Enter>. BIOS Virtual Version Drive(s) A R d LD RAID Easy Configuration Size #Stripes - ARRAY SELECTION StripSz MENU Status Management 0 Menu GB PORT 2 # 64 KB ONLINE 0 DNLIN A DNLIN A00-01 Enter VD Size: _ Virtual Drive 0 RAID = 1 Units= MB Size = MB DWC = Off RA = On Accept SPAN = NO Enter VD Size: Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 5. Follow step 10 to 14 of the previous section: Using Easy Configuration to create the RAID set. Workstation W60 Rev3 RAID Manual Page 9
10 Adding or iewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select > View/Add Configuration, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive View/Add to The Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press <Space>. When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. View/Add Configuration - ARRAY SELECTION MENU Management Menu PORT # 0 ONLIN A ONLIN A READY 3 READY Port # 2 DISK 77247MB HDS728080PLA380 PF20A60A SPACE-Sel,ENTER-EndArray,F10-,F2-Drive Info,F3-Virtual Drives,F4-HSP The information of the selected hard disk drive displays at the bottom of the screen. 3. Follow step 3 to 12 of section Creating a RAID set: Using Easy Configuration to add a new RAID set. Workstation W60 Rev3 RAID Manual Page 10
11 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the or command on the Management Menu. Using the command To initialize the virtual drive using the command 1. From the Management Menu, select, and then press <Enter>. Management Menu VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The screen displays the available RAID set(s) and prompts you to select the virtual drive to initialize. Use the arrow keys to select the virtual drive from the Virtual Drive selection, and then press <Space>. Management Menu Virtual Drive(s) d LD RAID Size #Stripes StripSz Status GB 2 64 KB ONLINE Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, F10- Workstation W60 Rev3 RAID Manual Page 11
12 3. Press <F10> to start initialization. When prompted, select Yes from the? dialog box, and then press <Enter>. Management Menu Virtual Drives Virtual Drive 0 Virtual Drive(s) d LD RAID Size #Stripes StripSz Status GB 2 64 KB ONLINE? Yes No Init Will Destroy Data On Selected VD(s) SPACE-(De)Select, F10- Initializing a virtual drive erases all data on the drive. 4. A progress bar appears on screen. If desired, press <Esc> to abort initialization. When initialization is completed, press <Esc>. Virtual Drive(s) d Management Menu LD RAID Size #Stripes StripSz Status 0 Init 10 Of VD MB Is In Process 4 64 KB ONLINE VD 0 Initialization Complete. Press Esc.. 100% Completed Virtual Drives Virtual Drive 0 SPACE-(De)Select, F10- Workstation W60 Rev3 RAID Manual Page 12
13 Using the command To initialize the virtual drives using the command 1. From the Management Menu, select > Virtual Drive, and then press <Enter>. Management Menu Adapter Virtual Drive Physical Drive Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. Select the virtual drive to initialize from the Virtual Drives sub menu, and then press <Enter>. Vitual Drive(1) Virtual Drive 0 Management Menu Adapter Virtual Drive Physical Drive Select VD Press ENTER To Select A VD, <Del> To Delete A VD Workstation W60 Rev3 RAID Manual Page 13
14 3. Select from the pop-up menu, and then press <Enter> to start initialization. Vitual Drive(1) Virtual Drive 0 Management Menu Adapter Virtual Drive Physical Drive Vitual Drive(0) Initialze View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4. When prompted, press the <Space> to select Yes from the? dialog box, and then press <Enter>. Vitual Drive(1) Virtual Drive 0 Management Menu Adapter Virtual Drive Physical Drive Vitual Drive(0) Initialze? View/Update Parameters Yes No Init Will Destroy Data On Selected VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5. A progress bar appears on screen. If desired, press <Esc> to abort initialization. When initialization is completed, press <Esc>. Workstation W60 Rev3 RAID Manual Page 14
15 ing failed drives You can manually rebuild failed hard disk drives using the command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select, and then press <Enter>. Management Menu PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. Select the drive you want to rebuild, and then press <Space>. Management Menu REBUILD - PHYSICAL DRIVES SELECTION MENU PORT # 0 ONLIN A FAIL A00-01 Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A SPACE-(De)Select,F10-Start,F2-Drive Information,F3-View Virtual Drives Workstation W60 Rev3 RAID Manual Page 15
16 3. After selecting the drive to rebuild, press <F10>. When prompted, press <Y> to rebuild the drive. REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # 0 ONLIN A RBLD A00-01 ing Of Drive Will Take A Few Minutes. Start ing Drive (Y/N)? Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A SPACE-(De)Select,F10-Start,F2-Drive Information,F3-View Virtual Drives 4. When rebuild is complete, press any key to continue. Workstation W60 Rev3 RAID Manual Page 16
17 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the > Adapter menu. The command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Command To check data consistency using the command 1. From the Management Menu, select, and then press <Enter>. Management Menu CC Of VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The screen displays the available RAID set(s) and prompts you to select the virtual drive to check. Press <Space> to select the virtual drive from the Virtual Drive sub-menu, and then press <F10>. Management Menu Virtual Drive(s) d LD RAID Size #Stripes StripSz Status GB 2 64 KB ONLINE Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, F10- Workstation W60 Rev3 RAID Manual Page 17
18 3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press <Enter>. Management Menu Virtual Drives Virtual Drive 0 Virtual Drive(s) d LD RAID Size #Stripes StripSz Status MB 4 64 KB ONLINE Consistency Check? Yes No Select VD SPACE-(De)Select, F10- A progress bar appears on screen. Virtual Drive(s) d Management Menu LD RAID Size #Stripes StripSz Status 0 10 CC Under MB Process 4 64 KB ONLINE VD 0 Consistency Check. Press Esc to Abort. 85 % Completed Virtual Drives Virtual Drive 0 The Data On The Drives Is Inconsistency. Repair Done! SPACE-(De)Select, F10-4. While checking the disk consistency, press <Esc> to display the following options. Stop - Stops the consistency check. The utility stores the percentage of disk checked, and when you restart checking, it continues from the last percentage completed rather than from zero percent. Continue - Continues the consistency check. Abort - Aborts the consistency check. When you restart checking, it continues from zero percent. 5. When checking is complete, press any key to continue. Workstation W60 Rev3 RAID Manual Page 18
19 Using the command To check data consistency using the command 1. From the Management Menu, select, and then select Virtual Drive from the sub-menu. 2. Use the arrow keys to select the virtual drive you want to check, and then press <Enter>. 3. Select from the pop-up menu, and then press <Enter>. 4. When prompted, use the arrow keys to select Yes from the dialog box to check the drive. 5. When checking is complete, press any key to continue. Workstation W60 Rev3 RAID Manual Page 19
20 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select > Clear Configuration, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. When prompted, use the arrow keys to select Yes from the Clear Configuration? dialog box, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration? Clear Configuration Yes Select Boot No Drive Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option The utility clears all the current array(s). 3. Press any key to continue. Workstation W60 Rev3 RAID Manual Page 20
21 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select > Select Boot Drive, and then press <Enter>. Configuration Menu Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive Select A Boot VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. When prompted, use the arrow keys to select the bootable virtual drive from the list, then press <Enter>. Bootable VDs(1):Current Boot VD(0) Configuration Boot Menu Drive 0 Easy Configuration Management Menu New Configuration View/Add Configuration Clear Configuration Select Boot Drive Select A Boot VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3. The virtual drive is selected as boot drive. Press any key to continue. Workstation W60 Rev3 RAID Manual Page 21
22 Enabling WriteCache You may manually enable the RAID controller s WriteCache option after creating a RAID set to improve the data transmission performance. To enable WriteCache When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. 1. From the Management Menu, select > Adapter, select an existing adapter, and then press <Enter> to display the adapter properties. 2. Select Disk WC, and then press <Enter> to turn on the option. Adapter 0 Rate = 30 Chk Const Rate = 30 Management Menu Adapter FGI Rate = 30 Virtual Drive BGI Rate = 30 Physical DriveDisk WC = Off Read Ahead = On Bios State = Enable Cont On Error = Yes Fast Init = Enable Auto = On Auto Resume = Enable Disk Coercion = 1GB Factory Default Disk Write Cache - Off(Write Through) or On(Write Back) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3. From the Management Menu, select > Virtual Drive, select an existing adapter and press <Enter>. Select View/Update Parameters and press <Enter> to display the adapter properties. 4. Select Disk WC, and then press <Enter> to turn on the option. Virtual Drive RAID = 0 Size = GB Management Menu Adapter Stripe Size = 64KB Virtual Drive #Stripes = 2 Physical Drive State = OPTIMAL Spans = 1 Disk WC = On Read Ahead = On Disk Write Cache Setting of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5. When finished, press any key to continue. Workstation W60 Rev3 RAID Manual Page 22
23 Intel Rapid Storage Technology Enterprise SCU/SATA Option ROM Utility The Intel Rapid Storage Technology enterprise SCU / SATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You can create RAID mode by use of onboard AHCI SATA ports. To use onboard SATA ports: 1. Install all the Serial ATA hard disk drives. 2. Turning on the system. During POST, press,del. to enter BIOS. Go to Advanced Menu > PCH SATA Configuration > SATA Mode, then press <Enter>. 3. Set SATA Mode to RAID Mode and save, then reboot system. 4. During POST, press <Ctrl+I> to display the utility main menu. To use SCU SATA ports: 1. Install all the SATA hard disk drives. 2. Turning on the system. During POST, press <Del> to enter BIOS. Go to Advanced Menu > PCH SCU SATA Configuration, then press <Enter>. 3. Confirm all the SATA hard disk drives you installed are correctly displayed, then reboot system. 4. During POST, press <Ctrl+I> to display the utility main menu. Workstation W60 Rev3 RAID Manual Page 23
24 To enter the Intel Rapid Storage Technology enterprise SCU Option ROM utility: 1. Install all the Serial ATA hard disk drives. 2. Turn on the system. 3. During POST, press <Ctrl+I> to display the utility main menu. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM Copyright(C) Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 3. Reset Disks to Non-RAID 2. Delete RAID Volume 4. Exit RAID Volumes: None defined. [ DISK/VOLUME INFORMATION ] Physical Disks: ID Drive Model Serial # Size Type/Status(Vol ID) 0 ST SS HWAS TR 279.3GB Non-RAID Disk 1 ST SS 37VN RAJ GB Non-RAID Disk 2 ST SS UEDY 279.3GB Non-RAID Disk 3 ST SS GWC G GB Non-RAID Disk [ ]-Select [ESC]-Exit [ENTER]-Select Menu The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options. The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen. The utility supports maximum four hard disk drives for RAID configuration. Workstation W60 Rev3 RAID Manual Page 24
25 Creating a RAID set To create a RAID set 1. From the utility main menu, select 1. Create RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM Copyright(C) Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Stripe) Disks: Select Disks Strip Size: 128KB Capacity: 0.0 GB Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less. [ ]Change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 2. Enter a name for the RAID set and press <Enter>. 3. When the RAID Level item is selected, press the up/down arrow key to select a RAID level to create, and then press <Enter>. 4. When the Disks item is selected, press <Enter> to select the hard disk drives you want to include in the RAID set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port Drive Model Serial # Size Status 0 ST SS HWAS TR 279.3GB Non-RAID Disk 1 ST SS 37VN RAJ GB Non-RAID Disk 2 ST SS UEDY 279.3GB Non-RAID Disk 3 ST SS GWC G GB Non-RAID Disk Select 2 to 6 disks to use in creating the volume. [ ]-Prev/Next [SPACE]-SelectDisk [ENTER]-Done 5. Use the up/down arrow key to select a drive, and then press <Space> to select. A small triangle marks the selected drive. Press <Enter> after completing your selection. Workstation W60 Rev3 RAID Manual Page 25
26 6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press <Enter>. The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. When the Capacity item is selected, enter the RAID volume capacity that you want and press <Enter>. The default value indicates the maximum allowed capacity. 8. When the Create Volume item is selected, press <Enter>. The following warning message appears. WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 9. Press <Y> to create the RAID volume and return to the main menu, or <N> to go back to the CREATE VOLUME menu. Creating a Recovery set To create a recovery set: 1. From the utility main menu, select 1. Create RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM Copyright(C) Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Stripe) Disks: Select Disks Strip Size: 128KB Capacity: 0.0 GB Sync: N/A Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less. [ ]Change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select Workstation W60 Rev3 RAID Manual Page 26
27 2. Enter a name for the recovery set and press <Enter>. 3. When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press <Enter>. 4. When the Disks item is selected, press <Enter> to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port Drive Model Serial # Size Status 0 ST SS HWAS TR 279.3GB Non-RAID Disk 1 ST SS 37VN RAJ GB Non-RAID Disk 2 ST SS UEDY 279.3GB Non-RAID Disk 3 ST SS GWC G GB Non-RAID Disk Select 1 Master and 1 Recovery disk to create volume. [[ ]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done 5. Use the up/down arrow keys to select a drive, press <TAB> to select a Master disk, and then press <SPACE> to select a Recovery disk. A small triangle marks the selected drive. Press <Enter> after completing your selection. 6. When the Sync item is selected, use the up/down arrow keys to select a sync option that you want and press <Enter>. 7. When the Create Volume item is selected, press <Enter>. The following warning message appears. WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 8. Press <Y> to create the recovery set and return to the main menu, or <N> to go back to the CREATE VOLUME menu. If a recovery set is created, you cannot add more RAID sets even when you have more non-raid disks installed in your system. Workstation W60 Rev3 RAID Manual Page 27
28 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM Copyright(C) Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Level Drives Capacity Status Bootable Volume0 RAID0(Stripe) GB Normal Yes [ HELP ] Deleting a volume will reset the disks to non-raid. WARNING: ALL DISK DATA WILL BE DELETED. (This does not apply to Recovery volumes) [ ]-Select [ESC]-Previous Menu [DEL]-Delete Volume 2. Use the up/down arrow keys to select the RAID set you want to delete, and then press <Del>. The following warning message appears. [ DELETE VOLUME VERIFICATION ] ALL DATA IN THE VOLUME WILL BE LOST! (This does not apply to Recovery volumes) Are you sure you want to delete volume Volume0? (Y/N): 3. Press <Y> to delete the RAID set and return to the utility main menu, or press <N> to return to the DELETE VOLUME menu. Workstation W60 Rev3 RAID Manual Page 28
29 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-raid. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>. The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-raid disk. WARNING: Resetting a disk causes all data on the disk to be lost. (This does not apply to Recovery volumes) Port Drive Model Serial # Size Status 0 ST SS HWAS TR 279.3GB Member Disk 1 ST SS 37VN RAJ GB Member Disk Select the disks that should be reset. [ ]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete 2. Use the up/down arrow keys to select the RAID set drive(s) you want to reset, and then press <Space> to select. 3. Press <Enter> to reset the RAID set drive(s). A confirmation message appears. 4. Press <Y> to reset the drive(s) or press <N> to return to the utility main menu Exiting the Intel Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 4. Exit, and then press <Enter>. The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press <Y> to exit or press <N> to return to the utility main menu. Workstation W60 Rev3 RAID Manual Page 29
30 ing the RAID This option is only for the RAID 1 set. ing the RAID with other non-raid disk If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays the status of the RAID volume as Degraded during POST. You can rebuild the RAID array with other installed non-raid disks. To rebuild the RAID with other non-raid disk: 1. At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology option ROM utility. 2. If there is a non-raid SATA Hard Disk available, the utility will prompt to rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select the destination disk or press <ESC> to exit. [ DEGRADED VOLUME DETECTED ] "Degraded" volume and disk available for rebuilding detected. Selecting a disk initiates a rebuild. completes in the operating system. Select the port of destination disk for rebuilding (ESC to exit): Port Drive Model Serial # Size X XXXXXXXXXXX XXXXXXXX XX.XGB [ ]-Previous/Next [ENTER]-Select [ESC]-Exit Select a destination disk with the same size as the original hard disk. Workstation W60 Rev3 RAID Manual Page 30
31 3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM Copyright(C) Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 3. Reset Disks to Non-RAID 2. Delete RAID Volume 4. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes: * = Data is Encrypted ID Name Level Strip Size Status Bootable 0 Volume0 RAID1(Mirror) N/A 149.0GB Yes Physical Devices: Port Drive Model Serial # Size Type/Status(Vol ID) 1 ST AS 9LS0F4HL 149.0GB Member Disk(0) 2 ST AS 3LS0JYL GB Member Disk(0) Volumes with status will be rebuilt within the operating system. [ ]-Select [ESC]-Exit [ENTER]-Select Menu 4. Exit Intel Rapid Storage Technology and reboot the system. 5. Under Microsoft Windows OS, select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage Manager utility. 6. From the View menu, select Advanced Mode to display the details of the Intel Rapid Storage Console. 7. From the Volumes view option, select RAID volume to view the rebuilding status. When finished, the status is changed to Normal. ing the RAID with a new hard disk If any of the SATA hard disk drives included in the RAID array failed, the system displays the status of the RAID volume as Degraded during POST. You may replace the disk drive and rebuild the RAID array. To rebuild the RAID with a new hard disk: 1. Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port. Select a destination disk with the same size as the original hard disk. 2. Reboot the system and then follow the steps in section ing the RAID with other non-raid disk. Workstation W60 Rev3 RAID Manual Page 31
32 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi- RAID using the Intel Rapid Storage Technology. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. Reboot the system and press <Del> to enter the BIOS setup utility during POST. 2. Go to the Boot menu and select the boot option priority. 3. Use up/down arrow keys to select the boot priority and press <Enter>. See section Boot menu for details. 4. From the Exit menu, select Save Changes & Exit, then press <Enter>. 5. When the confirmation window appears, select Yes, then press <Enter>. Workstation W60 Rev3 RAID Manual Page 32
33 Intel Rapid Storage Technology Enterprise Utility (Windows) The Intel Rapid Storage Technology enterprise utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. Before you using Intel Rapid Storage Technology enterprise utility, you need to change BIOS setting first: 1. Enter the BIOS Setup during POST. 2. Go to the Advanced Menu > Chipset Configuration > PCH Configuration> Onboard SATA Oprom, then press <Enter>. 3. Set Onboard SATA Oprom to [Enabled]. 4. Press <F10> to save your changes and exit the BIOS Setup. You need to manually install the Intel Rapid Storage Technology enterprise utility on a Windows operating system. Please refer to the installation instructions in Chapter 6. To enter the Intel Rapid Storage Technology enterprise utility under Windows operating system: 1. Turn on the system to windows desktop. 2. Click the Intel Rapid Storage Technology enterprise icon to display the main menu. Your storage system is configured for data protection, increased performance and optimal data storage capacity. You can further optimize your storage system by creating additional volumes. You can click Rescan to re-scan any attached hard disks. Workstation W60 Rev3 RAID Manual Page 33
34 Creating a RAID set To create a RAID set 1. From the utility main menu, select Create Volume and select volume type. 2. Then click Next. 3. Enter a name for the RAID set, then select the array disks. 4. Select Volume Size tab, you can drag the bar to decide the volume size. 5. Then click Next. If you hard disk with existing data and you don t want to keep data from one of the selected disks, choose NO in next column (If displayed). If you want to Enable volume write-back cache or volume, you can click Advanced tab to slelect. Workstation W60 Rev3 RAID Manual Page 34
35 6. Confirm volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can contuine using other applications during this time. When display Volume Ceation Complete message, you can click OK to finish. You still need to partition your new volume using Windows Disk Management before adding any data. When you are finished, you will see the following screen in Volumes field and you can change related items in the Volume Properties field. Workstation W60 Rev3 RAID Manual Page 35
36 Change Volume Type When you are finished to create a RAID set, you can view or change related items in the Volume Properties field. According to the following steps to change the type in Volume Properties: 1. Click the SAS array items you want to change in Volumes field. 2 From the Volume Properties field, select Type:RAID 1 Change type. 3. You can change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 4. Then select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and then click OK. The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. Workstation W60 Rev3 RAID Manual Page 36
37 Delete volume Take caution when deleting a volume. You will lose all data on the hard disk drives.back up data before continuing. To delete a volume: 1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes field you want to delete. 2. Then select Delete volume in Volume Properties field. The following screen appears. 3. Click Yes to delete the volume and return to the utility main menu, or click No to return to the main menu. Workstation W60 Rev3 RAID Manual Page 37
38 Preferences System Preferences Allow you set to show the notification area icon and show system information, warning, or errors here. Preferences Allow you set to sent of the following events: Storage system information Storage system warnings Storage system errors Workstation W60 Rev3 RAID Manual Page 38
39 Marvell RAID utility The onboard Marvell SATA 6.0 Gb/s controller allows you to create a RAID 0, RAID 1 or RAID 10 array using two SATA hard disk drives. Refer to Chapter 2 of your system user manual for the exact location of the Marvell SATA 6.0 Gb/s connector. To enter the Marvell utility, press <Ctrl> + <M> during POST. All exisiting data on the hard disk drives will be erased when creating or deleting a RAID array. Ensure that you have back up all your data in your hard disk drives before making any change to the drive status. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Topology Information HBA 0: Marvell 0 Vendor ID : 1B4B Virtual Disks Device ID : 9130 Free Physical Disks Revision ID : B1 PD 0: ST AS BIOS Version : PD 8: ST AS Firmware Version: PCIe Speed Rate : 5.0Gbps SATA as: AHCI Mode Help Marvell RAID on chip controller. ENTER: Operation F10: Exit/Save ESC: Return Create a RAID Array 1. Move the selection bar to HBA 0: Marvell 0 and press <Enter>. 2. Select Configuration Wizard and press <Enter>. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. ->Select free disks HBA 0: Marvell 0 Virtual Disks Free Physical Disks * PD 0: ST AS PD 8: ST AS Port ID : 0 PD ID : 0 Type : SATA PD Status : Unconfigured Size : MB Feature Support : MCQ 3G 48Bits Current Speed : 3G Model : ST AS Serial : 9LS0F4HL FW Version : 3.AAE Help Use space bar to select the free disks to be used in the array. ENTER: Operation SPACE: Select F10: Exit/Save ESC: Return 3. Press <Space> to select the hard drives to be included in the RAID array. An asterisk (*) appears in front of the selected hard drive. After selecting all the drives needed for the RAID array, press <Enter> to continue. Workstation W60 Rev3 RAID Manual Page 39
40 Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. ->Select free diskscreate Virtual Disk HBA 0: Marvell 0 RAID Level : RAID 0 Virtual Disks Max Size(MB) : Free Physical Disks Stripe Size : 64KB * PD 0: ST AS Gigabyte Rounding : 1G * PD 8: ST AS Quick Init : Yes Name : Default Threshold(%) : 90 Next Help Virtual disk configurations. ENTER: Select F10: Exit/Save ESC: Return 4. Use the up or down arrow key to move the selection bar and press <Enter> to configure further RAID settings. RAID Level: Select a RAID Level. Configuration options: [RAID 0] [RAID 1] [RAID 10] [HyperDuo] Stripe Size: Specifies the size of single data block on the virtual disk. In general, a larger stripe size is recommended for applications requiring large data transfers such as audio, video, and graphics. A smaller stripe size is better for applications with content in much smaller size, such as s and documents. Configuration options: [32K] [64K] Gigabyte Rounding: In the event of a single physical disk failure in a RAID 1 virtual disk, Gigabyte Rounding allows the replacement physical disk to be of a size slightly smaller than the existing physical disk. The capacity of the rebuilt virtual disk equals to the size of the smaller physical disk included in the RAID 1 array. The configuration options represent the tolerance value of drive capacity difference. Configuration options: [None] [1G] [10G] Name: Enter a name with 1 10 letters (no special characters) for the RAID array. 5. Move the selection bar to Next and press <Enter>. The following warning message appears: Create Virtual Disk Do you want to create this virtual disk? Yes No Press <Y> to create the RAID array, or press <N> to cancel. The new RAID array appears under Virtual Disks, as shown in the image below. Workstation W60 Rev3 RAID Manual Page 40
41 Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Topology Information HBA 0: Marvell 0 Virtual Disks VD 0: New_VD PD 0: ST AS PD 8: ST AS Free Physical Disks Vendor ID : 1B4B Device ID : 9130 Revision ID : B1 BIOS Version : Firmware Version: PCIe Speed Rate : SATA as: 5.0Gbps AHCI Mode Help Marvell RAID on chip controller. ENTER: Operation F10: Exit/Save ESC: Return 6. Press <F10>. The following warning message appears: Exit Do you want to exit from Marvell BIOS Setup? Yes No Press <Y> to save the RAID setting and exit the Marvell RAID utility. Delete an existing RAID Array 1. Select the RAID array to delete and press <Enter>. Select Delete and press <Enter>. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Topology Information HBA 0: Marvell 0 ID : 0 Virtual Disks Name : New_VD VD 0: New_VD Status : Functional PD 0: ST AS [Delete] Stripte Size : 64K PD 8: ST AS RAID Mode : RAID0 Free Physical Disks Size : MB BGA Status : N/A Number of PDs : 2 Members : 0 8 Help Delete the selected virtual disk. ENTER: Operation F10: Exit/Save ESC: Return Workstation W60 Rev3 RAID Manual Page 41
42 2. The following warning message appears: Delete Virtual Disk Do you want to delete this virtual disk? Yes No Press <Y> to delete the selected RAID array. The following warning message appears: Delete MBR Do you want to delete MBR from this virtual disk? Yes No Press <Y> to delete the Master Boot Record (MBR) from the selected RAID array. 3. Press <F10>. The following warning message appears: Exit Do you want to exit from Marvell BIOS Setup? Yes No Press <Y> to save the RAID setting and exit the Marvell RAID utility. Workstation W60 Rev3 RAID Manual Page 42
LSI Software RAID Configuration Utility
LSI Software RAID Configuration Utility E8581 First Edition August 2013 Copyright 2013 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
PCI Express SATA / esata 6Gb/s RAID Card User Manual
PCI Express SATA / esata 6Gb/s RAID Card User Manual Specifications : - 2 x SATA 6Gb/s Port (SATA version) - 2 x esata 6Gb/s Port (esata version) - Max. 6Gb/s transfer rate per port - Supports both SATA
VIA / JMicron RAID Installation Guide
VIA / JMicron RAID Installation Guide 1. Introduction to VIA / JMicron RAID Installation Guide. 3 2. VIA RAID Installation Guide. 3 2.1 VIA BIOS RAID Installation Guide.. 3 2.1.1 Introduction of RAID.
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
RAID configuration and driver installation guide
Server systems and motherboards RAID configuration and driver installation guide For AP130-E1 5U Rackmount Server AP1720-E2 5U Rackmount Server NCCH-DL Motherboard PSCH-L Motherboard E1600 First edition
How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)
4-1-4 Configuring SATA Hard Drive(s) To configure SATA hard drive(s), follow the steps below: (1) Install SATA hard drive(s) in your system. (2) Configure SATA controller mode and boot sequence in BIOS
Intel ESB2 SATA RAID Setup Guidelines
Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines After all the hardware has been installed, you must first configure Intel ESB2 SATA RAID Settings before you install the Windows
VIA RAID configurations
VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R southbridge chipset. It supports RAID 0, RAID 1 and JBOD with two independent Serial
Configuring ThinkServer RAID 100 on the Lenovo TS430
Configuring ThinkServer RAID 100 on the Lenovo TS430 Contents Overview 02 Embedded RAID 100 features on TS430 02 RAID Overview 02 Choosing the RAID Level 02 RAID 0 02 RAID 1 02 RAID 5 03 RAID 10 03 Configuring
Configuring ThinkServer RAID 100 on the TS140 and TS440
Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES
RAID installation guide for ITE8212F
RAID installation guide for ITE8212F Contents Contents 2 1 Introduction 3 1.1 About this Guide 3 1.2 The Basics 3 1.2.1 What is RAID? 3 1.2.2 Advantages of RAID 3 1.2.3 Disadvantages of RAID 3 1.3 Different
NVIDIA RAID Installation Guide
NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista TM / Vista
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines After all hardware has been installed, you must fi rst confi gure the Intel SATA HostRAID settings
English. Configuring SATA Hard Drive(s)
Configuring SATA Hard Drive(s) To configure SATA hard drive(s), follow the steps below: (1) Install SATA hard drive(s) in your system. (2) Configure SATA controller mode and boot sequence in BIOS Setup.
PCIe SATA 6G Raid Card
PCIe SATA 6G Raid Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...
Configuring ThinkServer RAID 100 on the Lenovo TS130
Configuring ThinkServer RAID 100 on the Lenovo TS130 Contents Overview 02 Embedded RAID 100 features on TS130 02 RAID Overview 02 Choosing the RAID Level 02 RAID 0 02 RAID 1 03 Configuring RAID 03 BIOS
www.devicemanuals.eu
AMD RAID Introduction The integrate one SATA host controller separately, and support RAID function for performance and reliability. SB950 SATA RAID provides support for RAID 0 (Striping), RAID 1 (Mirroring),
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows XP / XP 64-bit / Vista / Vista 64-bit With
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista / Vista 64-bit / XP /
User Guide - English. Embedded MegaRAID Software
User Guide - English Embedded MegaRAID Software April 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2
Table of Contents Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2 (1) Installing IDE hard drive(s) in your system... 2 (2) Configuring GigaRAID controller mode and boot sequence
EX-3516 4-Port SATA3 RAID/HyperDuo PCIe(x2) Card
EX-3516 4-Port SATA3 RAID/HyperDuo PCIe(x2) Card Thank you for purchasing this 4-Port SATA3 RAID/HyperDuo PCIe Card. It is designed to support up to 4 SATA3 ports in RAID 0 and RAID 1, RAID 0+1 modes and
Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.
1. Introduction Onboard-RAID IEI s Onboard-RAID is designed with Promise IDE RAID controller to provide a cost-effective, high performance RAID that adds performance and/or reliability to systems using
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Confi gurations...3 2.1 Introduction
Ultra ATA 133 RAID PCI Pro
Ultra ATA 133 RAID PCI Pro 1-1 Introduction Quick Installation Guide This ultra high-speed dual channel Ultra ATA/133 RAID controller is designed to support RAID 0, 1, 0+1 and JBOD. RAID configurations
SATA+Ultra ATA RAID CONTROLLER RC212. User Manual
SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID
VIA RAID Installation Guide
VIA RAID Installation Guide 1 VIA BIOS RAID Installation Guide.... 3 1.1 Introduction of RAID... 3 1.2 RAID Configuration Precautions... 3 1.3 BIOS Configuration Utility.. 4 1.3.1 Enter BIOS Configuration
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
SATA RAID Function (Only for chipset Sil3132 used) User s Manual
SATA RAID Function (Only for chipset Sil3132 used) User s Manual 12ME-SI3132-001 Table of Contents 1 WELCOME...4 1.1 SATARAID5 FEATURES...4 2 AN INTRODUCTION TO RAID...5 2.1 DISK STRIPING (RAID 0)...5
SATA II 4 Port PCI RAID Card RC217 User Manual
SATA II 4 Port PCI RAID Card RC217 SATA II 4 Port PCI RAID Card This Manual is for many Models of SATAII RAID5 HBA that uses Silicon Image SATA II SiI3124 chipset: 1) 32bit PCI bus host card 2) 64bit PCI-X
Promise FastTrak 100-Lite RAID Controller
Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted
ITE RAID Controller USER MANUAL
ITE RAID Controller USER MANUAL 120410096E1N Copyright Copyright 2004. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated
Intel Matrix Storage Console
Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,
Serial ATA RAID PCI. User's Manual
Serial ATA RAID PCI User's Manual Chapter 1 Introduction Table of Contents 1-1 Features and Benefits. 1 1-2 System Requirements. 1 Chapter 2 RAID Arrays 2-1 RAID Overview.. 2 2-1.1 RAID 0 (striping)...
M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual
Serial ATA and Parallel ATA Host Controller Rev. 0.96 December 03, 2003 Copyright 2003 ULi Electronics Inc. All rights reserved. COPYRIGHT NOTICE All information in this document is considered ULi Electronics
SATA1.5G/ATA133 RAID Controller Card RC215 User Manual
SATA1.5G/ATA133 RAID Controller Card RC215 Features and Benefits Compliant with Serial ATA 1.0 specification Compliant with PCI Specification, revision 2.2 Provides three independent channels to connect
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel PCH RAID Configuration Utility
Intel PCH RAID Configuration Utility USER S MANUAL Revision 1.0a The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for
RAID OPTION ROM USER MANUAL. Version 1.6
RAID OPTION ROM USER MANUAL Version 1.6 RAID Option ROM User Manual Copyright 2008 Advanced Micro Devices, Inc. All Rights Reserved. Copyright by Advanced Micro Devices, Inc. (AMD). No part of this manual
USER S GUIDE. MegaRAID Configuration Software. February 2003 Version 1.0 DB15-000269-00
USER S GUIDE MegaRAID Configuration Software February 2003 DB15-000269-00 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by
RAID Manual. Edition. Trademarks V1.0 P/N: 91-187-CK8-A5-0E
RAID Manual Edition V1.0 P/N: 91-187-CK8-A5-0E Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. Contents NVIDIA RAID... 1 RAID Arrays...
NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition -
NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition - 7th Edition 12-2006 808-882425-676-G Preface The User's Guide explains the utility MegaRAID Storage Manager to be used for
VT8237 SATA RAID User Manual
VT8237 SATA RAID User Manual Enter BIOS Configuration Utility When the system powers on, the following information will appear on screen. Press the Tab key to enter BIOS configuration utility. 39 VIA Technologies,Inc.VIA
RAID User Guide. Edition. Trademarks V1.0 P/N: 91-187C51GME0-00
RAID User Guide Edition V1.0 P/N: 91-187C51GME0-00 Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. Contents NVIDIA RAID...1 RAID Arrays...1
Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer
Configuring ThinkServer RAID 500 and RAID 700 Adapters Lenovo ThinkServer October 4, 2011 Contents Overview... 4 RAID 500 features... 4 RAID 700 features... 4 RAID Overview... 4 Choosing the RAID Level...
PC Workstation 2015 RAID Service Guide
Introduction PC Workstation 2015 RAID Service Guide This document lists the SATA Disk Drives approved for use in the PCWS 2015 including RAID, suggestions for determining which drive in a mirrored pair
Adaptec SAS RAID Configuration and the Windows OS Installation Instructions
Adaptec SAS RAID Confi guration and the Windows OS Installation Instructions Adaptec SAS RAID Configuration and the Windows OS Installation Instructions After all the hardware has been installed, you must
WebBIOS Configuration Utility Guide
Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC WebBIOS Configuration Utility Guide www.dell.com support.dell.com Information in this document is subject to change without notice.
Using ATI Array Management Software (WebPAM)
Redundant Array of Independent Disks (RAID) on HP Compaq dc5750 Business PCs Using ATI Array Management Software (WebPAM) Introduction............................................................ 2 Mirroring
Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)
PRIMERGY RX300 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Overview/Note) This chapter explains the overview of the disk array and features of the SCSI array controller. Chapter
Marvell SATA3 RAID Installation Guide
Marvell SATA3 RAID Installation Guide Overview The Marvell RAID Utility (MRU) is a browser-based graphical user interface (GUI) tool for the Marvell RAID adapter. It supports IO Controllers (IOC) and RAID-On-Chip
Serial ATA RAID PCI Card
Serial ATA RAID PCI Card User Manual 1 Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification, Rev. 2.3 Compliant with Serial ATA 1.0 specification Provides two independent
SATA RAID SIL 3112 CONTROLLER USER S MANUAL
SATA RAID SIL 3112 CONTROLLER USER S MANUAL 120410056E1N Copyright Copyright 2003. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system
HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation
HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation LSI Integrated RAID controller and Host Bus Adapter... 2 Steps common to all methods for enabling LSI Integrated RAID...
MegaRAID RAID Controller Configuration Software Guide
MegaRAID RAID Controller Configuration Software Guide MAN-MR-GENSW 7/20/00 Copyright 2001 LSI Logic Corporation All rights reserved. LSI Logic Corporation 6145-D Northbelt Parkway Norcross, GA 30071 This
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.
SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled
ESATA PCI CARD. User s Manual
ESATA PCI CARD User s Manual Introduction... 3 System Requirements... 3 RAID Introduction... 3 BIOS Configuration Utility... 5 Configuring Arrays... 5 RAID Mode Definitions... 5 BIOS Configuration Utility...
SATARAID5 Serial ATA RAID5 Management Software
SATARAID5 Serial ATA RAID5 Management Software Home Edition Preliminary Draft Subject to Change Without Notice 05/7/04 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com
RAID Option Installation
RAID Option Installation Introduction RAID option is a PCI board including two HDD. The RAID option installation is carried out in 4 main phases: Pase A: Hardware installation Phase B: Configuration of
SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1
SiS 180 S-ATA User s Manual Quick User s Guide Version 0.1 Edition April 2003 Copyright Trademarks SiS is a registered trademark of Silicon Integrated Systems Corp. All brand or product names mentioned
Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.
Configuring ThinkServer RAID 500 and RAID 700 Adapters Contents Overview 2 Drive Policy 28 RAID 500 features 2 Disable BGI 28 RAID 700 features 2 Adapter Properties 28 RAID Overview 2 Management Tasks
Embedded MegaRAID Software
Embedded MegaRAID Software User Guide 48712-00, Rev. B Revision History Version and Date Description of Changes 48712-00, Rev. B, Revised the guide to document changes to the driver installation procedures,
RAID EzAssist Configuration Utility Quick Configuration Guide
RAID EzAssist Configuration Utility Quick Configuration Guide DB15-000277-00 First Edition 08P5520 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The
USER S GUIDE. Embedded MegaRAID Software. July 2006 Version 1.0 DB15-000356-00
USER S GUIDE Embedded MegaRAID Software July 2006 Version 1.0 DB15-000356-00 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used
SBI-7125B-T1 Blade Module RAID Setup Procedure
SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.
Setting up SATA RAID on the HP xw4600, xw6600, and xw8600 Workstations
Setting up SATA RAID on the HP xw4600, xw6600, and xw8600 Workstations Introduction This document details the steps needed to setup RAID 0, RAID 1, RAID 5, and RAID 10 disk configurations on an HP xw4600,
VAIO Computer Recovery Options Guide
VAIO Computer Recovery Options Guide This guide provides information about restoring individual software programs, software drivers, drive partition(s), or the hard disk drive to the original factory settings.
Managing Storage Using RAID
Note The RAID feature is applicable to E-Series Servers and the SM E-Series NCE. The RAID feature is not applicable to the EHWIC E-Series NCE and the NIM E-Series NCE. This chapter includes the following
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft and Windows are U.S. registered trademarks
Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs
Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs Using AMD Array Management Software (RAIDXpert) Introduction............................................................2
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Vista are U.S. registered
Encore SATA2 RAID PCIe Card
Encore SATA2 RAID PCIe Card User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. 1 Features and Benefits Compliant with PCI Express Base Specification 1.0a Compliant
Promise RAID Function
Promise RAID Function (Only For Chipset 20265/20276 Used) USER S MANUAL 12ME-RAI276-001 RAID Function Copyright Copyright by GIGA-BYTE TECHNOLOGY CO., LTD. ( GBT ) No part of this manual may be reproduced
RocketRAID 1640. User's Manual. Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc.
RocketRAID 1640 User's Manual Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc. Copyright Copyright 2003 HighPoint Technologies, Inc.. This document contains materials protected by International
RAID installation guide
RAID installation guide V1.0 Date : 2009-06-29 TWINHEAD INTERNATIONAL CORP. 10F, 550 Rueiguang Road Neihu, Taipei, Taiwan 114,ROC. TEL(886)2 5589 9999 FAX (886) 2 5555 7777 Enabling RAID in BIOS Perform
Intel Rapid Storage Technology Enterprise (Intel RSTe) Software User s Guide. Revision 1.1 February, 2012 Order Number: G40440-001
Intel Rapid Storage Technology Enterprise (Intel RSTe) Software User s Guide Revision 1.1 February, 2012 Order Number: G40440-001 Disclaimer Disclaimer Information in this document is provided in connection
4-1-4 Serial ATA SATA. A. Intel ICH8R (1) SATA (1) SATA (2) BIOS SATA (3) RAID BIOS RAID (4) SATA (5) SATA
4-1-4 Serial ATA (1) (2) BIOS (3) RAID BIOS RAID ( ) (4) (5) (a) ( RAID ) (b) (c) Windows XP 2000 (d) A. Intel ICH8R (1) ( ) ( ) RAID - 69 - (2) BIOS BIOS 1 BIOS POST (Power-On Self Test ) BIOS CMOS
SiS S-ATA User s Manual. Quick User s Guide. Version 0.1
SiS S-ATA User s Manual Quick User s Guide Version 0.1 Edition April 2003 Copyright Trademarks SiS is a registered trademark of Silicon Integrated Systems Corp. All brand or product names mentioned are
Phoenix SecureCore TM Setup Utility
Phoenix SecureCore TM Setup Utility Important information: We continually strive to bring you the latest and proven features and technologies. As part of our drive to continually improve our products modifications
SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: 91-187-U49-M2-0E
SiS964 RAID User s Manual Edition V1.0 P/N: 91-187-U49-M2-0E Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. CONTENTS Introduction...
AMD SP5100 Dot Hill SATA RAID Users Manual V100
AMD SP5100 Dot Hill SATA RAID Users Manual V100 1 Table of Contents Section 1 Dot Hill Firmware Overview Firmware Overview Page 3 Firmware Option Rom/Firmware Overview Page 3 Firmware Menus Page 4 Initialize
GigaRAID (IT8212) ATA RAID Controller USER S MANUAL
GigaRAID (IT8212) ATA RAID Controller USER S MANUAL 12ME-IT8212-006R Copyright Copyright by GIGA-BYTE TECHNOLOGY CO., LTD. ( GBT ) No part of this manual may be reproduced or transmitted in any from without
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2009 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Vista are U.S. registered
Embedded MegaRAID Software
USER S GUIDE Embedded MegaRAID Software November 2006 Version 2.0 80-00142-01 Rev. A This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to
SATARAID5 Serial ATA RAID5 Management Software. Users Manual
SATARAID5 Serial ATA RAID5 Management Software Home Edition Users Manual 03/14/05 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com Copyright 2004, Silicon
How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (
SiS964/SiS180 SATA w/ RAID User s Manual Quick User s Guide Version 0.3 Edition December 2003 Copyright 2003 Silicon Integrated Systems Corp. Trademarks SiS is a registered trademark of Silicon Integrated
SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3
SiS964/SiS180 SATA w/ RAID User s Manual Quick User s Guide Version 0.3 Edition December 2003 Copyright 2003 Silicon Integrated Systems Corp. Trademarks SiS is a registered trademark of Silicon Integrated
HP Embedded SATA RAID Controller
HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject
Serial ATA 4-Channel RAID Quick Installation Guide
Serial ATA 4-Channel RAID Quick Installation Guide Introducing the Serial ATA 4-Channel RAID The Serial ATA 4-Channel RAID is an ultra high-speed four channel Serial ATA controller for use in Pentium class
Dell SAS RAID Storage Manager. User s Guide. www.dell.com support.dell.com
Dell SAS RAID Storage Manager User s Guide www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:
HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001
HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject
USER S GUIDE. MegaRAID SAS Software. June 2007 Version 2.0. 80-00156-01, Rev. B
USER S GUIDE MegaRAID SAS Software June 2007 Version 2.0 80-00156-01, Rev. B This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or