Surgelogic Surge Protective Device (SPD)



Similar documents
Surgelogic Surge Protection Device EMA, EBA, and HWA Series

CPS Y S K CPS Y S C

Applications. Remote Display Mounting Kits

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Power surges can also be generated by equipment in your facility such as:

Uninterruptible Power Supply

GRX-PWM Pulse Width Modulation Interface

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type 1, 3, & 3R Enclosures

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Power Management Module 2. Installation

surge protection solutions

Lightning Arresters P KVA P KVA. Description & Installation

ASCO SERIES 185 Power Transfer Switches

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Distribution Dry Type Transformers

6 Buck Boost Transformers

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Power Supplies 3. SDN-P DIN Rail Series

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

LOXONE 12 Channel Amplifier

Three-phase monitoring relay CM-PFE

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

8146/5 Series Breaker Panelboards

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Solid State Timers Type F

Safety technique. Emergency stop module BO 5988 safemaster

A series of technology briefs spanning Tyco Electronics product portfolio

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

RC NETWORKS SALES GUIDE

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Bourns Resistive Products

Manual motor starter MS116

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Bulletin 150 SMC Flex Smart Motor Controller Specifications

SURGE PROTECTIVE DEVICES

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Series 8146/5-V37 and Series 8150/5-V37

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

LM117 LM317A LM317 3-Terminal Adjustable Regulator

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

HERZ-Thermal Actuators

Quick Connect. quick - simple - efficient.

I STAR COMPUTER CO., LTD

Continuous Power... Continuous Protection

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Centro-Matic Automatic Lubrication Systems System Controls

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Photovoltaic Solar Energy Unit EESFB

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

This section applies to the design and installation of transformers.

SMART SENSOR COLLECTION

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

48 SERIES Relay interface modules 10 A

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

38 Series - Relay interface modules A

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

White Paper: Electrical Ground Rules

DCS Input/Output Relay Card Series

Unified requirements for systems with voltages above 1 kv up to 15 kv

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

CalMod Design-Build Electrification Services

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Advanced Power Supply Topics

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermistor motor protection

ADM1TE 5/30A DIN rail single phase two wire energy meter

Telecommunication Line Protectors

Current Transformers

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Magnum Mobile Generator MMG55 Specifications

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Transcription:

Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2 pplication Information.........................................5 Selection and Specifications.....................................6 Wiring Diagrams.............................................10 Dimensions and Weights......................................16

Surgelogic Surge Protective Device () Product Description Product Description Description EM Series The Surgelogic EM Series surge protective device () is a modular parallel device. The EM device has multi-stage suppression circuits consisting of field-proven, fast-acting metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-toground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to isolate the and ensure shutdown in the event of MOV damage during severe overvoltages, even when operated on high-fault current power systems. The suppression elements are encapsulated in a UL Recognized potting material, another performance element that provides additional protection. filter provides EMI/RFI noise attenuation. On-line diagnostics continuously monitor the device status, and LEDs signal a loss of a suppression circuit. n audible alarm with an enable/disable feature and dry contacts are included in the standard diagnostic package. EM Design Features External mounting next to panelboards, switchboards, switchgear, or motor control centers (Ms) High-energy parallel design for SI/IEEE 62.41 and 62.45 category B and 3 applications. Individually fused suppression modes Duty cycle tested (SI 62.41 3, 10 k 20 kv) minimum 5000 impulses Short circuit current rating: 200 k Ten-year warranty Thermal cutout opper bus bar construction Solid state bidirectional Push-to-test on-line diagnostic display Front panel alarm with enable/disable switch LED indicators indicate loss of protection, or fully operational circuit EMI/RFI filtering up to -30 db (100 khz to 100 MHz) UL 1449 Listed UL 1283 Listed EM Performance Features Surge apacity L L G G 120 V Units 120 k/phase 60 k 60 k 120 k 90 k 160 k/phase 80 k 80 k 120 k 90 k 240 k/phase 120 k 120 k 120 k 90 k 320 k/phase 160 k 160 k 240 k 180 k 480 k/phase 240 k 240 k 240 k 180 k EM Series Voltage Specifications atalog umber Service Voltage UL Suppression Voltage Rating (SVR) L L G G L L MOV1 TVS1EM... 120/240 V, 1-phase 150 V TVS2EM... 208Y/120 V, 3-phase or 3- or 4-wire 150 V TVS3EM... 240/120 V, 3-phase high-leg delta 800/ 1500/ 275/150 V TVS4EM... 480Y/277 V, 3-phase, 3- or 4-wire 1500 V 320 V TVS7EM... 380Y/220 V, 3-phase, 3- or 4-wire 1500 V 320 V TVS8EM... 600Y/347 V, 3-phase, 3- or 4-wire 1200 V 1200 V 1200 V 2000 V 420 V 1 MOV = Maximum ontinuous Operating Voltage. 2

Surgelogic Surge Protective Device () Product Description Description EB series The Surgelogic EB series surge protective device () is a non-modular parallel device. The EB device has multi-stage suppression circuits consisting of field-proven, fast-acting metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-toground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to isolate the and ensure shutdown in the event of MOV damage during severe overvoltages, even when operated on high-fault current power systems. The suppression elements are encapsulated in a UL Recognized potting material, another performance element that provides additional protection. filter provides EMI/RFI noise attenuation. On-line diagnostics continuously monitor the device status, and LEDs signal a loss of a suppression circuit. n audible alarm with an enable/disable feature and dry contacts are included in the standard diagnostic package. EB Design Features External mounting next to panelboards, switchboards, switchgear, or motor control centers (Ms) High-energy parallel design for SI/IEEE 62.41 and 62.45 category B and 3 applications Individually fused suppression modes Duty cycle tested (SI 62.41 3, 10 k 20kV) minimum 5000 impulses Short circuit current rating: 200 k Ten-year warranty Thermal cutout Solid state bidirectional Push-to-test on-line diagnostic display Front panel alarm with enable/disable switch LED indicators indicate loss of protection or fully operational circuit EMI/RFI filtering up to -30 db (100 khz to 100 MHz) UL 1449 Listed UL 1283 Listed EB Performance Features Surge apacity L L G G 120 V Units 120 k/phase 60 k 60 k 120 k 90 k 160 k/phase 80 k 80 k 120 k 90 k 240 k/phase 120 k 120 k 120 k 90 k EB Series Voltage Specifications atalog umber L L G G L L MOV1 150 V TVS1EB... 120/240 V, 1-phase TVS2EB... 208Y/120 V, 3-phase, 3- or 4-wire 150 V TVS3EB... 240/120 V, 3-phase, high-leg delta 800/ 1500/ 275/150 V TVS4EB... 480Y/277 V, 3-phase, 3- or 4-wire 1500 V 320 V TVS7EB... 380Y/220 V, 3-phase, 3- or 4-wire 1500 V 320 V TVS8EB... 600Y/347 V, 3-phase, 3- or 4-wire 1200 V 1200 V 1200 V 2000 V 420 V 1 Service Voltage UL Suppression Voltage Rating (SVR) MOV = Maximum ontinuous Operating Voltage. 3

Surgelogic Surge Protective Device () Product Description Description HW Series The Surgelogic HW series surge protective device () is a non-modular, nipple mounted parallel device. The HW device has multi-stage suppression circuits consisting of field-proven, fast-acting metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-toground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to isolate the and ensure shutdown in the event of MOV damage during severe overvoltages, even when operated on high-fault current power systems. The suppression elements are encapsulated in a UL Recognized potting material, another performance element that provides additional protection. filter provides EMI/RFI noise attenuation. On-line diagnostics continuously monitor the device status, and LEDs signal a loss of a suppression circuit. n audible alarm and dry contacts are included in the standard diagnostic package. HW Design Features External mounting to panelboards Individually fused suppression modes Thermal cutout Solid state bidirectional LED indicators indicate loss of protection or fully operational circuit HW Performance Features High-energy parallel design for SI/IEEE 62.41 and 62.45 category, B, and 3 applications Short circuit current rating: 200 k EMI/RFI filtering up to -30 db (100 khz to 100 MHz) Ten-year warranty UL 1449 Listed UL 1283 Listed Surge apacity L L G G 50 k/phase 25 k 25 k 25 k 80 k/phase 40 k 40 k 40 k 120 k/phase 60 k 60 k 40 k HW Series Voltage Specifications UL Suppression Voltage Rating (SVR) atalog umber Service Voltage L L G G L L MOV 1 TVS1HW... 120/240 V, 1-phase 150 V TVS2HW... 208Y/120 V, 3-phase, 3- or 4-wire 150 V TVS3HW... 240/120 V, 3-phase, high-leg delta 800/ 1500/ 275/150 V TVS4HW... 480Y/277 V, 3-phase, 3- or 4-wire 1600 V 320 V TVS7HW... 380Y/220 V, 3-phase, 3- or 4-wire 1600 V 320 V 1 MOV = Maximum ontinuous Operating Voltage. 4

Surgelogic Surge Protective Device () pplication Information pplication Information The effects of lightning and the damage caused by lightning-generated transients are well known. The failure of electronic equipment in a facility located in a high lightning area can easily be attributed directly to lightning-generated transients. Transient protection can be installed on the power distribution system to protect this equipment from these externally generated transients. Lower magnitude transients generated within a facility and their effect on microprocessor-based equipment are less obvious than the transients induced by lightning. Transient voltages generated from inductive motors, pumps, electric welders, etc., may not be large enough to cause immediate damage, but they can cause equipment to malfunction. damaging transient voltage can enter a facility from several locations. The highest level of protection should be provided at the service entrance. second level of protection should be provided at distribution points serving critical areas, for example, computer rooms, accounting areas, and laboratories. Other facility entry points that should be protected include panels serving outdoor lights or outdoor equipment, such as motors. Protection should also be provided for critical areas with equipment essential to the company. Square D brand products offered by Schneider Electric provide protection at every level of the electrical distribution system. Typical applications include: Banking Education Government Petrochemical Military Publishing Transportation Wastewater/Sanitation Medical Financial Telecommunications utomated Manufacturing Retail Utility Insurance Data Processing OTE: Refer to the product-specific catalog for information about internally mounted devices. 5

Surgelogic Surge Protective Device () Selection and Specifications Selection and Specifications EM Series Service Voltage Peak Surge urrent Rating Per Phase atalog umber 1 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 3- or 4-wire 240/120 V, 3-phase, 4-wire, high-leg delta 480Y/277 V, 3-phase, 3- or 4-wire 380Y/220 V, 3-phase, 3- or 4-wire 600Y/347 V, 3-phase, 3- or 4-wire 1 * = enclosure option, _ = any other options. 120 k TVS1EM12*_ 160 k TVS1EM16*_ 240 k TVS1EM24*_ 320 k TVS1EM32*_ 480 k TVS1EM48*_ 120 k TVS2EM12*_ 160 k TVS2EM16*_ 240 k TVS2EM24*_ 320 k TVS2EM32*_ 480 k TVS2EM48*_ 120 k TVS3EM12*_ 160 k TVS3EM16*_ 240 k TVS3EM24*_ 320 k TVS3EM32*_ 480 k TVS3EM48*_ 120 k TVS4EM12*_ 160 k TVS4EM16*_ 240 k TVS4EM24*_ 320 k TVS4EM32*_ 480 k TVS4EM48*_ 120 k TVS7EM12*_ 160 k TVS7EM16*_ 240 k TVS7EM24*_ 320 k TVS7EM32*_ 480 k TVS7EM48*_ 120 k TVS8EM12*_ 160 k TVS8EM16*_ 240 k TVS8EM24*_ 320 k TVS8EM32*_ 480 k TVS8EM48*_ 6

Surgelogic Surge Protective Device () Selection and Specifications EB Series Service Voltage Peak Surge urrent Rating Per Phase atalog umber 1 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 3- or 4-wire 240/120 V, 3-phase, 4-wire, high-leg delta 480Y/277 V, 3-phase, 3- or 4-wire 380Y/220 V, 3-phase, 3- or 4-wire 600Y/347 V, 3-phase, 3- or 4-wire 1 * = enclosure option, _ = any other options. 120 k TVS1EB12*_ 160 k TVS1EB16*_ 240 k TVS1EB24*_ 120 k TVS2EB12*_ 160 k TVS2EB16*_ 240 k TVS2EB24*_ 120 k TVS3EB12*_ 160 k TVS3EB16*_ 240 k TVS3EB24*_ 120 k TVS4EB12*_ 160 k TVS4EB16*_ 240 k TVS4EB24*_ 120 k TVS7EB12*_ 160 k TVS7EB16*_ 240 k TVS7EB24*_ 120 k TVS8EB12*_ 160 k TVS8EB16*_ 240 k TVS8EB24*_ HW Series Service Voltage Peak Surge urrent Rating Per Phase atalog umber 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 3- or 4-wire 240/120 V, 3-phase, 4-wire, high-leg delta 480Y/277 V, 3-phase, 3- or 4-wire 380Y/220 V, 3-phase, 3- or 4-wire 50 k TVS1HW50X 80 k TVS1HW80X 120 k TVS1HW12X 50 k TVS2HW50X 80 k TVS2HW80X 120 k TVS2HW12X 50 k TVS3HW50X 80 k TVS3HW80X 120 k TVS3HW12X 50 k TVS4HW50X 80 k TVS4HW80X 120 k TVS4HW12X 50 k TVS7HW50X 80 k TVS7HW80X 120 k TVS7HW12X Specifications Relative Humidity Operating Frequency Storage Temperature Operating Temperature Standards Fusing 0 to 95% non-condensing 47 63 Hz -40 to +65 (-40 to +149 F) EM, EB: 0 to +50 (+32 to +122 F) HW: -25 to +60 (-13 to +140 F) UL, UL 1449 Second Edition 2007, UL1283 Individually-fused suppression modes (200 kir) 7

Surgelogic Surge Protective Device () Selection and Specifications Enclosure Options Enclosure Type Environment Provides Protection gainst vailable on Series atalog Option umber EM 1 Indoor ontact with the enclosed equipment. EM, EB EM 12 Indoor irculating dust, falling dirt, dripping liquids. EM, EB EM 3R Outdoor Falling rain, sleet. Undamaged by ice. EM, EB EM 4X Stainless EM 4X Plastic Other Options Indoor/Outdoor Indoor/Outdoor Windblown dust and rain, splashing water, hose-directed water. Resists corrosion (120 k 240 k units only). Windblown dust and rain, splashing water, hose-directed water. Resists corrosion. EM, EB HW only S one (standard) Option Description vailable on Series udible larm The audible alarm provides sound if an inoperative condition occurs. ll Dry ontacts Provides available Form type contacts. ll Integral Disconnect Surge ounter Remote Monitor Flush-Mount ollar Provides a mechanical means to electrically disconnect the entire surge protective device to facilitate the servicing of the unit s components. Displays the combined total number of transient voltage surges detected from L G, L L, L, and G since the counter was last reset. Displays the alarm status of the surge protective device up to 1,000 ft (305 m) away from the unit. This option uses the dry contacts. Provides a mechanical means to install the surge protective device flush to the surface of a wall (120 k 240 k units only). EM, EB EM, EB ll EM, EB atalog Option umber one (standard) one (standard) I TVS12RMU TVS12FMK (12 in.) TVS20FMK (20 in.) EM Module Replacements 1 2 System Voltage 1 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 3- or 4-wire 240/120 V, 3-phase, 4-wire, high-leg delta 2 480Y/277 V, 3-phase, 3- or 4-wire 380Y/220 V, 3-phase, 3- or 4-wire 600Y/347 V, 3-phase, 3- or 4-wire Peak Surge urrent Rating With all system voltages, the must be grounded in accordance with all applicable standards. Phase B modules are different than Phase and Phase modules. atalog umber Phase Phase B Phase 120 k M1IM12 empty M1IM12 160 k M1IM16 empty M1IM16 240 k M1IM24 empty M1IM24 120 k M1IM12 M1IM12 M1IM12 160 k M1IM16 M1IM16 M1IM16 240 k M1IM24 M1IM24 M1IM24 120 k M1IM12 M3IM12 M1IM12 160 k M1IM16 M3IM16 M1IM16 240 k M1IM24 M3IM24 M1IM24 120 k M4IM12 M4IM12 M4IM12 160 k M4IM16 M4IM16 M4IM16 240 k M4IM24 M4IM24 M4IM24 120 k M7IM12 M7IM12 M7IM12 160 k M7IM16 M7IM16 M7IM16 240 k M7IM24 M7IM24 M7IM24 120 k M8IM12 M8IM12 M8IM12 160 k M8IM16 M8IM16 M8IM16 240 k M8IM24 M8IM24 M8IM24 8

Surgelogic Surge Protective Device () Selection and Specifications EB Module Replacements System Voltage 1 Peak Surge urrent Rating atalog umber 120 M1IB12 120/240 V, 1-phase, 3-wire 160 M1IB16 240 M1IB24 120 M2IB12 208Y/120 V, 3-phase, 3- or 4-wire 160 M2IB16 240 M2IB24 120 M3IB12 240/120 V, 3-phase, 4-wire, high-lag delta 160 M3IB16 240 M3IB24 120 M4IB12 480Y/277 V, 3-phase, 3- or 4-wire 160 M4IB16 240 M4IB24 120 M7IB12 380Y/220 V, 3-phase, 3- or 4-wire 160 M7IB16 240 M7IB24 120 M8IB12 600Y/347 V, 3-phase, 3- or 4-wire 160 M8IB16 240 M8IB24 1 With all system voltages, the must be grounded in accordance with all applicable standards. 9

Surgelogic Surge Protective Device () Wiring Diagrams Wiring Diagrams EM Series EM 1-Phase, 3-Wire, Grounded Installation Phase eutral Ground ustomer onnections 120 k 240k Phase EM 3-Phase, 4-Wire, Grounded Wye Installation ustomer onnections 320 k 480k Phase Phase B B ustomer onnections 120 k 240k eutral Ground Phase ustomer onnections 320 k 480k 10

Surgelogic Surge Protective Device () Wiring Diagrams EM 3-Phase, 4-Wire, High-Leg Delta Installation PHSE B (HIGH-LEG) PHSE PHSE EUTRL GROUD B ustomer onnections 120 k 240k EM 1-Phase, 3-Wire, Grounded Installation with Integral Disconnect ustomer onnections 320 k 480k PHSE EUTRL GROUD ustomer onnections 120 k 240k PHSE ustomer onnections 320 k 480k 11

Surgelogic Surge Protective Device () Wiring Diagrams EM 3-Phase, 4-Wire, Grounded Wye Installation with Integral Disconnect PHSE PHSE B EUTRL GROUD B ustomer onnections 120 k - 240 k PHSE ustomer onnections 320 k - 480 k EM 3-Phase, 4-Wire, High-Leg Delta Installation with Integral Disconnect PHSE B (HIGH-LEG) PHSE PHSE EUTRL GROUD B ustomer onnections 120 k - 240 k ustomer onnections 320 k - 480 k 12

contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 Surgelogic Surge Protective Device () Wiring Diagrams EB Series EB 1-Phase, 3-Wire, Grounded Installation PHSE EUTRL GROUD PHSE ustomer onnections EB 3-Phase, 4-Wire, Grounded Wye Installation PHSE PHSE B B EUTRL GROUD PHSE ustomer onnections EB 3-Phase, 4-Wire, High-Leg Delta Installation PHSE B (HIGH-LEG) B PHSE PHSE EUTRL GROUD ustomer onnections 13

contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 contra Sobretensiones Transitorias / contre les Surtensions www.squared.com 8222-0004 Surgelogic Surge Protective Device () Wiring Diagrams EB 1-Phase, 3-Wire, Grounded Installation with Integral Disconnect PHSE EUTRL GROUD PHSE ustomer onnections EB 3-Phase, 4-Wire, Grounded Wye Installation with Integral Disconnect PHSE PHSE B B EUTRL GROUD PHSE ustomer onnections EB 3-Phase, 4-Wire, High-Leg Delta Installation with Integral Disconnect PHSE B (HIGH-LEG) B PHSE PHSE EUTRL GROUD ustomer onnections 14

Surgelogic Surge Protective Device () Wiring Diagrams HW Series HW 1-Phase, 3-Wire, Grounded Installation Phase eutral Ground B Phase ustomer onnections HW 3-Phase, 4-Wire, Grounded Wye Installation Phase Phase B eutral Ground B B Phase ustomer onnections HW 3-Phase, 4-Wire, High-Leg Delta Installation Phase B B B Phase Phase eutral Ground ustomer onnections 15

Surgelogic Surge Protective Device () Dimensions and Weights Dimensions and Weights EM/EB Series 12 x 12 EM 1 / 3R / 12 Enclosures 12.44 [311] 8.70 [218] 14.00 [350] 13.40 [335] 0.31 [8] Dimensions: in. [mm] 16 x 20 EM 1 / 3R / 12 Enclosures with Integral Disconnect, EM 4X Stainless Steel Enclosure with or without Integral Disconnect 16.44 [411] 12.70 [318] 22.00 [550] 21.40 [535] Dimensions: in. [mm] pprox. Weight Depth 35 lbs (15 kg) maximum 6 in. (152 mm) 16

Surgelogic Surge Protective Device () Dimensions and Weights 12 inch (305 mm) and 20 inch (508 mm) Flush-Mount ollars TVS12FMK TVS20FMK 0.50 [13] 14.10 [353] 15.10 [378] 14.10 [353] ø0.31 [8] 1.44 [37] 12.23 [306] 0.88 [22] Typ 10.34 [259] 23.10 [578] 0.50 [13] 22.10 [553] 19.1 [478] 18.10 [453] ø0.31 [8] 1.44 [37] 20.23 [506] 0.88 [22] Typ 18.34 [459] 15.10 [378] 2.38 [60] 1.44 [37] 12.23 [306] Dimensions: in. [mm] 1.44 [37] 16.23 [406] 2.38 [60] Dimensions: in. [mm] pprox. Weight Depth 5.6 lbs (2.5 kg) maximum 1.01 in. (26 mm) 20 x 24 EM 1 / 3R / 12 Enclosures for 320 k and 480 k Units with or without Integral Disconnect (Flush Mount ollar ot vailable) 20.44 [511] 15.90 [398] 25.40 [635] 26.00 [650] Dimensions: in. [mm] pprox. Weight Depth 48 lbs (21 kg) maximum 6 in. (152 mm) 17

Surgelogic Surge Protective Device () Dimensions and Weights HW EM 4X Plastic Enclosures 9.40 [239] 8.62 [219] 2.30 [58] 4.80 [122] 0.72 [18] 0.75 [19] 4.31 [109] 3/4" 14 PT Straight 1.77 [45] 1.95 [50] 2.92 [74] 3.10 [79] Dimensions: in. [mm] pprox. Weight Depth Wire Gauge Wire Length 7 lbs (3 kg) maximum 3.10 in. (79 mm) Power: #10 WG, Dry ontacts: #22 WG 24 in. (609.6 mm) 18

Surgelogic Surge Protective Device () Dimensions and Weights 19

Schneider Electric US 1601 Mercer Road Lexington, KY 40511 US 1-888-SquareD (1-888-778-2733) www.schneider-electric.us Schneider Electric anada 19 Waterman venue, M4B 1 Y2 Toronto, Ontario 1-800-565-6699 www.schneider-electric.ca 1310T0202R05/09 Replaces 1310T0202R5/07 dated 05/2007.