25-4-2007 MALDI-MS Product overview 1 Company Instrument Benchtop (j/n)

Similar documents
MALDI-MS 1. Target type (Samples/target)

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

CARE. Price List for CARE Products. Version CARE in JPY as of Jan, 2015 Prices are subject to change without prior notice. Innovation with Integrity

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Functional Data Analysis of MALDI TOF Protein Spectra

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Per Andrén Dept. of Pharmaceutical Biosciences Medical Mass Spectrometry, Uppsala University, Uppsala, Sweden

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

La Protéomique : Etat de l art et perspectives

GC-MS Product overview 1

High resolution mass spectrometry (HRMS*) in Graz

Mass Spectrometry Based Proteomics

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Application Note # MT-90 MALDI-TDS: A Coherent MALDI Top-Down-Sequencing Approach Applied to the ABRF-Protein Research Group Study 2008

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Introduction to Proteomics

Introduction to Proteomics 1.0

Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE

ProteinPilot Report for ProteinPilot Software

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Appendix 5 Overview of requirements in English

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

NUVISAN Pharma Services

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Master course KEMM03 Principles of Mass Spectrometric Protein Characterization. Exam

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

Proteomics in Practice

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Applications for MALDI-TOF MS in Clinical Microbiology. MALDI-TOF is not a Cocktail. The Ideal Identification System 9/10/2012

Proteomic Analysis using Accurate Mass Tags. Gordon Anderson PNNL January 4-5, 2005

Electrospray Ion Trap Mass Spectrometry. Introduction

WATERS QUANTITATIVE ANALYSIS solutions

Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Proteomic data analysis for Orbitrap datasets using Resources available at MSI. September 28 th 2011 Pratik Jagtap

Challenges in Computational Analysis of Mass Spectrometry Data for Proteomics

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Bio and Polymer Analytics. RD Instrumental Analytical Chemistry. Organic Trace Analytics. RD Environmental & Process Analytics

Session 1. Course Presentation: Mass spectrometry-based proteomics for molecular and cellular biologists

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Mass spectrometry. Dr. Kevin R. Tucker

flexanalysis User Manual

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

LC-MS Productenoverzicht 1 Leverancier (contactpersoon) Agilent Technologies (Martin Haex, afd. LSCA)

For the next half hour I m going to be describing some of the different options for peak peaking. The profit is with getting better protein ID or

Week 9: MS in Space and Proteomics

Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going

LC-MS/MS for Chromatographers

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

NIRCal Software data sheet

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

Mascot Integra: Data management for Proteomics ASMS 2004

How Mascot Integra helps run a Core Lab

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Micromass LCT User s Guide

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

How To Build An Amd Quas 3 Ar Mass Spectrometer

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Agilent G2721AA/G2733AA Spectrum Mill MS Proteomics Workbench

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Introduction to mass spectrometry (MS) based proteomics and metabolomics

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Alignment Laser System.

App. Note # FTMS-47+MT-113 MALDI Imaging with Single Cell Resolution at 10 µm Pixel Size

Microarray Technology

Error Tolerant Searching of Uninterpreted MS/MS Data

Introduction to Proteomics

Summary of the characteristics of different mass analyzers

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

Specifications. MassHunter WorkStation for Agilent 7700 Series ICP-MS. Specifications: MassHunter Workstation (G7211A) for the Agilent 7700 Series

A Streamlined Workflow for Untargeted Metabolomics

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Waters Core Chromatography Training (2 Days)

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

TS2Mascot. Introduction. System Requirements. Installation. Interactive Use

Preprocessing, Management, and Analysis of Mass Spectrometry Proteomics Data

Transcription:

25-4-2007 MALDI-MS Product overview 1 Voyager TM DE- PRO ja ja <20 ppm () 2x96, 100, 384, 400 well, 337 nm N2 DE TM, Time-ion selection, PSD, Collision-induced dissociation (CID) Voyager TM DE- (s)str ja <5 ppm () 2x96, 100, 384, 400 well, 337 nm N2 (optie Nd-YAG) DE TM, Time-ion selection, PSD, CID, high sensitivity Detector 4700, MALDI- TOFTOF; Proteomics Discovery System TM ja <2 ppm () 2x96, 100, 384, 400, 1536 well, membrane/gel, Weefsel target, hydrofobic masks, Opti- Solid State 355 nm, 200 Hz laser DE TM, accurate Timed-ion selection, real MS/MS, hoog resolutie MS/MS, High sensitivity Detector, Unattended Automated High Throughput with RDA TM (Result Dependent Analysis), Oracle data management, GPS TM (Global Proteome Server), diverse sample prep. robots Windows 2000/XP, BioMarker Discovery, PTM analyses, Abs. en Rel. Quantificatie analyses, Global Proteome Server, RDA, Imaging MS, LC-MALDI, LIMS 4800 Plus, MALDI- TOFTOF; Proteomics Discovery System TM ja <2 ppm () 2x96, 100, 384, 400, 1536 well, membrane/gel, Weefsel target, hydrofobic masks, Opti- Solid State 355 nm, 200 Hz OptiBeam laser DE TM, accurate Timed-ion selection, real MS/MS, hoog resolutie MS/MS, High sensitivity Detector, Unattended Automated High Throughput with RDA TM (Result Dependent Analysis), Oracle data management, GPS TM (Global Proteome Server), diverse sample prep. robots Windows 2000/XP, BioMarker Discovery, PTM analyses, Abs. en Rel. Quantificatie analyses, ProteinPilot, Markerview, RDA, Imaging MS, LC-MALDI, cicat, itraq, SILAC, LIMS QSTAR Elite quadrupoolvluchtijd hybride ja <5 ppm 2x96, 100, 384, 400 well,, Cyphergen-source TEMPO MALDI spot robot, LC PROTEINPILOT met PARAGON, Packings Probot, MS-MS met ANALYST (Windows2000/XP), Add on hoog-resolutie in MS2. Met LINAC tools: IDA (Information Dependent (PULSAR)TM botsingscel. Acquisition) anauwkeurigheid <5 ppm, differentiele expressie studies, hoge automatisatie graad uitbreidbaar met prep. Robot, SELDI-analysis, Opti-TOF

25-4-2007 MALDI-MS Product overview 2 microflex LT yes linear only 105. < 75 Target size exactly ¼ of industry standard microtiter plates Various 96-spot targets available Compatible with Bruker Daltonics, sample preparation robotics Patented AnchorChip techlogy for fast, automated data acquisition, increased sequence coverage and 10-100fold sensitivity increase 20Hz N 2 laser Gridless design of ion source with improved Pulsed Ion Extraction (PIE TM ). Ultrastable power supplies for TOF analyzer, detector and ion source. especially well integrated with Clinprotools software for biomarker discovery, Getools for DNA SNP getyping and DNA QC applications plus an unique and innvative Biotyper module for identification of microorganisms is available. microflex yes 105 linear or 196. Linear: < 50 : < 15 ppm Target size exactly ¼ of industry standard microtiter plates Various 96-spot targets available Compatible with Bruker Daltonics, sample preparation robotics Patented AnchorChip techlogy for fast, automated data acquisition, increased sequence coverage and 10-100fold sensitivity increase Nitrogen laser with up to 20 Hz repetition rate >15000 resolution microscout TM Ion Source with state-of-the-art pulsed ion extraction Optional MS/MS capability (PSD) Service features Remote on-line service capability Extended self diagstics Fully integrated in the powerful CompassTM suite Highly intuitive GUI for simple instrument and workflow control Smooth data transfer to peripherals and library search engines Optional Compass security pack for regulated environments Linear and high-resolution TOF analyzer Powerful Compass software suite Fully integrated in PROTEINEER, CLINPROT and GENOLINK system solutions. Supplementary IQ, OQ-PV procedures available MALDi molecular imager optional, 120 linear < 20 slide adapter for 2 glass slides with conductive coating to be used in MALDI imaging of tissue 200 Hz solid state new imageprep robot for tissue (incl new preparation with <50 micrometer SMARTbeam) with droplets and high spectral quality. software controlled spot sizes between 10 and 200 microns Fleximaging (tissue imaging) as part of the clinprot solution package for Biomarker Analysis. ClassImaging multivariate statistics for classification of several images.

25-4-2007 MALDI-MS Product overview 3 Autoflex III 120 linear or 215. Linear: < 20 : < 5 ppm, and Twister improved sensitivity. 200 Hz solid state resolution >20,000 () (incl SMARTbeam Gridless design, DE, PSD, ISD, ) CID, HIMAS detector, improved sensitivity, Twister robot (automated analysis of up to 30,000 samples/day) Proteir Spotpicker Robot, Proteir Digest & Preparation Robot, Barcode reader, SPR(Biacore)- MS, (na)lc-maldi Mascot/Profound search, (proteins), RapiDevo (devo Proteomics), Getools (SNP getyping), imaging), Biotyper (microorganisms) Autoflex III TOF/TOF 120 linear or 215.. Uncompromi sed linear performance Linear: < 20 : <5 ppm, and Twister improved sensitivity. 200 Hz solid state same as Autoflex TOF, with LIFT (incl SMARTbeam TOF/TOF and CID MS/MS ) options. TOF performance uncompromised when TOF/TOF switched off.t3-sequencing of intact proteins possible, broad massrange resolution PAN. Mascot/Profound search, (proteins), WARP-LC (protein quantitation), RapiDevo (devo Proteomics), Getools (SNP getyping), imaging), Biotyper (microorganisms). Ultraflex III TOF/TOF 320.. Uncompromi sed linear performance Linear: < 15 : < 3 Paramic mass range calibration, and Twister improved sensitivity (<200amol) 200 Hz solid state same as Ultraflex TOF, with LIFT- (incl SMARTbeam II TOF/TOF MS/MS options. TOF ) performance uncompromised when TOF/TOF switched off. T3- sequencing of intact proteins possible. Broad massrange resolution PAN. Mascot/Profound search, (proteins), WARP-LC (protein quantitation), RapiDevo (devo Proteomics), Getools (SNP getyping), imaging), Biotyper (microorganisms).

25-4-2007 MALDI-MS Product overview 4 IonSpec/Va rian ProMALDI FTMS (7.0 Tesla magnet) n.a. (ICR cel) < 2 ppm, AB 4700 plates 1 ppm (interne standaard, andere standaardisatie Maldi target plates ) optiol 15-8,500 mass range MS/MS opties: ECD, IRMPD, simultane ECD/IRMPD Omega 2XP (Windows XP), PeakHunter, de vo sequencing IonSpec/Va rian ProMALDI FTMS (9.4 Tesla magnet) n.a. (ICR cel) < 2 ppm, AB 4700 plates 1 ppm (interne standaard, andere standaardisatie Maldi target plates ) optiol 15-18,000 mass range MS/MS opties: ECD, IRMPD, simultane ECD/IRMPD Omega 2XP (Windows XP), PeakHunter, de vo sequencing MaldiisoTOF ja j < 20 ppm AB 4700 plates standaard - Analyser Pro(Windows XP) PerkinElmer Benelux protof 2000 MALDI O- TOF Spectromet er N Y < 5 Range to 300,000 Da 96 to 1536 well reusable stainless steel or singleuse MALDI chip target plates Up to 100 Hz MALDI laser with TOFWorks software. Discriminatory extended life (> 200 million analysis of MS spectra performed by using pulses); Fmol sensitivity with >4 PG600 Biomarker Discovery Software. orders dynamic range; Orthogonal PrOTOF anf PG600 are part of TOF with Collisional Cooling; Dual PerkinElmer Biomarker Discovery Platform Processor system controller; Fully called BioXPRESSION. integrated software platform Shimadzu Benelux AXIMA-QIT (Quadrupol e Ion Trap- TOF) 337 nm N2 Ion Trap, MS n,variable CID control, precursor Ion selection resolution >1000,special adaptors for chiptechlogy, mass resl >6000 Shimadzu Benelux Axima - TOF² Shimadzu Benelux AXIMA- CFR plus Shimadzu Benelux AXIMA- CFR <10 ppm with IC 96, 384 and 1536 337 nm N2 MS/MS, range 1-500 kda, resolution > 20,000 Precursor ion selection resolution > 400 337 nm N2 Seamless PSD, Robotic Sample Processor, CID,Resolution>20,000,special adaptor for chip techlgie 337 nm N2 Seamless PSD, Robotic Sample Processor, Resolution>10,000 Shimadzu Benelux AXIMA- LNR Liniar flight tube, 1,2m <50 ppm with IC 96, 384 and 1536 337 nm N2 Seamless PSD, Robotic SampleProcessor, Resolution>4000

25-4-2007 MALDI-MS Product overview 5 Waters, Micromass techlogies Maldi-Micro- yes yes 10 ppm, internal calibation 96 of 384 positives, user definable plates 337 nm N2 TLF; standard Parallel PSD ( PSD, without parent ion selection!) Lynx 4.0 (Windows XP of Windows 2000), Lynx is CFR 21 part 11 complaint.; various integrated links to Microbelynx, Proteinlynx Global server.) Waters, Micromass techlogies MALDI-Q- TOF Premier yes < 3 ppm 96 of 384 positives, user definable plates 337 nm N2 Parent ion resolulion. Accurate mass MS and MS/MS, Lynx 4.0 (Windows XP of Windows 2000), Lynx is CFR 21 part 11 complaint.; various integrated links to Microbelynx, Proteinlynx Global server.)