GC-MS Product overview 1
|
|
|
- Hugo Riley
- 10 years ago
- Views:
Transcription
1 GC-MS Product overview 1 Agilent Technologies Agilent 5975-N singlequadrupole 1050 EI-inert, PCI, Agilent-MSD Chemstation Agiilent-6890 and 6850 spectral libraries and security pack available. Inert source, EI with CI source, Synchronous SIM/Scan, Quick swap, Dean switch, Deconvolution Reporting Software (DRS) ATAS Benelux B.V. LECO GC-TOF-MS PEGASUS IV amu EI Windows-based Data System. Dynamic Range of 4 to 6 orders, Total System Automation, max. 500 spectra/second range, ATAS Benelux B.V. JEOL JMS-T100GC amu EI CI (PCI and Direct Insertion Probe FAB EI,CI,DEI/DCI,FD/FI, > Resolution, suitable for Fast GCMS, isolation valve, ATAS Benelux B.V. Agilent Technologies 5975C Series Diffusion- and Turbopump systems singlequadrupole 1, amu EI Optional CI (PCI and Optional DIP Windows XP based Agilent-MSD Chemstation 5,200 amu/second with 0.1 amu scan step size, MS Spectral Library: NIST 02, Wiley 7th Edition, Stan Pesticide; Inert ion source: programmable up to 350 C, delivers enhanced response for active compounds and late eluters; Fully Hydrogen Safe Bruker Daltonics EM640 and EM640S mobile GC-MS single quadrupole EI, FI (option) membrane inlet for air sampling Immediately usable for shockproof, ruggedized and fast analysis. Especially well suited for detection of chemical warfare agents; direct coupling to dedicated libraries for substance identification (chemical warfare, catastrophy management)
2 GC-MS Product overview 2 Bruker Daltonics mm2 mobile GC- MS single quadrupool membrane inlet for air sampling. Immediately usable, low weight (30 kg!). Within 15 minutes identification of soil, water or air samples. Especially well suited for detection of chemical warfare agents; direct coupling to dedicated libraries for substance identification (chemical warfare, catastrophy management) Da Vinci Europe Laboratory Solutions B.V. LECO GC-TOF-MS PEGASUS IV amu EI Windows-based Data System. Dynamic Range of 4 to 6 orders, Total System Automation, max. 500 spectra/second range, Da Vinci Europe Laboratory Solutions B.V. JEOL JMS-T100GC amu EI CI (PCI and Direct Insertion Probe FAB EI,CI,DEI/DCI,FD/FI, > Resolution, suitable for Fast GCMS, isolation valve, Da Vinci Europe Laboratory Solutions B.V. Agilent singlequadrupole Technologies 5975C Series Diffusie- en Turbopomp 1, amu EI Optional CI (PCI and Optional DIP Windows XP based Agilent-MSD Chemstation 5,200 amu/second with 0.1 amu scan step size, MS Spectral Library: NIST 02, Wiley 7th Edition, Stan Pesticide; Inert ion source: programmable up to 350 C, delivers enhanced response for active compounds and late eluters; Fully Hydrogen Safe Interscience FocusDSQII single quadrupool EI, PCI,, FocusGC curved prefilter-technologie; amu/sec en tot 50 scans per seconde, vacuumslot, SIM/Fullscan simultaan, 70,250 of 400 L/sec turbo
3 GC-MS Product overview 3 Interscience TraceDSQII single quadrupool EI, PCI,, deconvolution by means of Xtract interace Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC curved prefilter-technology, vacuum slot, DIP/DEP probes and digital CIcontrol, amu/sec up to 50 scans per second, SIM/Fullscan simultaneous and PPINICI; 70, 250 or 400 L/sec turbo Interscience Focus PolarisQ ion-trap (MSx MS) EI, PCI,, FocusGC External Ionisation chamber with vacuum slot, MS-MS (MSn n=5), 70, 250 of 400L/sec turbo Interscience TracePolarisQ ion-trap (MS x MS) EI, PCI,, Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC External Ionisation chamber with vacuum slot, MS-MS (MSn n=5), DIP/DEP Probes, digital CI-control, PPNICI, variabel damping gas 70 or 250 L/sec turbo Interscience Tempus Plus TOF EI, PCI, Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC Benchtop, 100 scans/sec, >10^5 dynamic range, classical spectra Interscience Syft Voice100 Selected ion flow tube CI Syft 3 precursor ions (H3O+, O2+ en NO+), analysis time from 15 sec, calibration not necessary JAS Benelux Agilent 5975 Inert MSD quadrupole amu EI, PCI en. Full LAN communication JAS Benelux JAS / Agilent quadrupole amu EI, PCI en 5975 double MSD. Full LAN communication The JAS double MSD allows both EI and CI in 1 run JAS Benelux JAS /QQQ MS Triple quad amu EI, PCI en. Full LAN communication JAS Benelux GCxGC met Agilent 5975 Inert MSD quadrupole amu EI, PCI en. Full LAN communication JEOL (EUROPE) B.V. GCMateII magnetic sector, double focussing 2,500 EI, PCI,, FAB, DIP JEOL (Windows) Agilent-7890A 5000 Resolution, Benchtop Model, Full Automatic Probe, MS/MS Linked scan
4 GC-MS Product overview 4 JEOL (EUROPE) B.V. Mstation JMS-700 magnetic sector, double focussing JEOL (EUROPE) B.V. JMS-800D magnetic sector, double focussing JEOL (EUROPE) B.V. JMS-T100GC 25,000 EI, PCI,, FAB, FD, FI, DCI, JEOL Agilent-7890A resolution 25,000 EI, PCI,, JEOL Agilent-7890A resolution specific for doxin analysis > 2,000 EI, CI, (pos & neg), DIP, DEP, DEI/DCI, FD/FI JEOL (Windows) Agilent-7890A > Resolution JEOL (EUROPE) B.V. JMS-Q1000GC Quadrapole 1,500 EI, CI, DIP JEOL (Windows) Agilent-7890A > Resolution, S/N > 120 Leco Instrumente GmbH Leco Pegasus IV GC-TOF MS amu EI Complete Automated, Quality Deconvoution, Matrix Masking of (Windows based) Agilent 6890N GC, Agilent 7890 Dynamic Range of 4 to 6 orders, Total GC, Agilent 7683 AutoSampler, System Automation, max. 500 GC-PAL AutoSampler, CombiPAL spectra/second range Robot/Sampler, RVM-LTM / MACH, Upgradable to GC GC- TOF MS MSVision MSVision MSVision IonSpec/Varian ProMALDI FTMS (7.0 Tesla magnet) IonSpec/Varian ProMALDI FTMS (9.4 Tesla magnet) MS Solutions GC- IsoTOF Ion Cyclotron Resonance (ICR) Ion Cyclotron Resonance (ICR) 15-8,500 (+ Maldi) 15-18,000 (+ Maldi) Omega 2XP (Windows XP), PeakHunter, de novo sequencing Omega 2XP (Windows XP), PeakHunter, de novo sequencing Varian CP-3800, Agilent 6890 Varian CP-3800, Agilent 6890 MS/MS options: CID, ECD, IRMPD, simultaneous ECD/IRMPD MS/MS options: CID, ECD, IRMPD, simultaneous ECD/IRMPD TOF Mass Analyser Pro (Windows XP) Agilent 6890 multidimensional GC, linear range: 6 decades
5 GC-MS Product overview 5 PerkinElmer Benelux (M. Visscher) Clarus 600 singlequadrupole GC/MS in C, T, S, or D version EI, in C- version also CI+, CI- Turbomass (Windows XP) PerkinElmer Clarus 500 GC PCI/ optie, fast scanning, SIFI Mode with Simultaneous Full Scan and SIR, LVI and unique MS Vent (columm backflush or column change without vacuum stop), Touchscreen monitoring. Different pumping capacities in C, T, S, and D versions Shimadzu Benelux QP2010S singlequadrupole EI, dual filament GCMSsolutions met MS Navigator (Windows 2000, XP) Shimadzu GC2010 (+ GC extra detector) AOC20/AOC5000 autoinjector for Headspace, SPME, Thermal Desorbtion and Pyrolysis. Direct Insertion probe and Pyrolyse unit possible, diverse specific spectral libraries available, very useful for Basic GCMS Shimadzu Benelux QP2010plus singlequadrupole EI, PCI, combinatie PCI, CI and SEI. Dual filament GCMSsolutions met MS Navigator (Windows 2000, XP) Shimadzu GC2010 (+ GC extra detector) AOC20/AOC5000 autoinjector for Headspace, SPME, Thermal Desorbtion and Pyrolysis. Same as QP2010 except: extreme sensitivity 1pg OFN >160:1. FAST Scan/SIM. Automated Ajustable Retention TImes. Real Dual Column GCMS. Thermo Fisher Scientific Quadrupole, iontrap en TOF via Interscience Thermo Fisher Scientific DFS Magnetic sector (BE) Da EI, CI ( Pos en Neg.) FAB, FD/FI Xcalibur (Windows XP) Trace GC and Agilent 6890 Optional DIP and DCI probes. System may be upgraded to LC-MS (APCI and ESI). Special Dioxin configurations available with 1 of 2 GC's Thermo Fisher Scientific Delta V Advantage GC-IRMS (C,H,N,O en S isotoop ratio) Magnetic sector 1-80 Da at 3 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options like Elemental Analyser, Gasbench, Carbonate and LC-Isolink Thermo Fisher Scientific Delta V Plus GC- Magnetic IRMS sector (C,H,N,O en S isotoop ratio) 1-96 Da at 3 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options likeelemental Analyser, Gasbench, Carbonate en LC-Isolink. Number of collectors extendable to 10 Faraday cups Thermo Fisher Scientific Finnigan MAT253 GC-IRMS (C,H,N,O,S en isotoop ratio) Magnetic sector Da at 10 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options like Elemental Analyser, Gasbench, Carbonate and LC-Isolink; also continuous flow H/D measurements. Extentable to 8 aquisition channels
6 GC-MS Product overview 6 Varian B.V. Saturn 2100 ion-trap 650 EI, CI, MS Workstation GC MS-MS / SIS / liquid CI Varian B.V. Saturn 2200 ion-trap 650 EI, CI MS Workstation GC MS-MS / SIS / liquid CI Varian B.V GC/MS ion-trap EI, PCI,, Hybrid CI MS Workstation GC Internal and External Ionisation + Hybride Chemical Ionisation for extra selectivity; MS/MS; scan speed 10000(u/s) Varian B.V. 320 Singlequadrupole singlequadrupole 2000 EI, PCI, MS Workstation GC Direct Insert & exposure Probe / Vacuum interlock standard / Curved collision cell / possibility to upgrade to LC/MS/MS and GC/MS/MS Varian B.V. 320 Triplequadrupole triplequadrupole 2000 EI, PCI, MS Workstation GC Direct Insert & exposure Probe / Vacuum interlock standaard / Curved collision cell / possibility to upgrade to LC/MS/MS and GC/MS/MS Varian B.V Triplequadrupole triplequadrupole 800 EI, PCI, MS Workstation GC MS-MS / Probe / Vacuum interlock standaard / Curved collision cell / possibility to upgrade to LC/MS/MS Waters, Micromass technologies GCT Premier vluchttijd 1500 EI, PCI,, FI MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal Resolution 7000 at 3.5 GHz TDC; better than 1 mda for m/z < 200, better than 5 ppm for m/z > 200; Solid-probe option; DRE; Linear dynamic range 4 orders Waters, Micromass technologies Quattro-Micro-API triplequadrupool 1200 EI, PCI,, MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal Bechtop MS/MS Solid-probe option
7 GC-MS Product overview 7 Waters, Micromass technologies AutoSpec Premier Sector vanaf 3000 Naast EI, CI, de meeste alle ionisatie technologie. MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal resolution (20% valley)
How To Build An Amd Quas 3 Ar Mass Spectrometer
Classical and special AMD Magnetic Sector mass spectrometers (extracted from power point presentations) High Resolution Mass Spectromter AMD 402/403 S 6 High Resolution Mass Spectrometer AMD 604 S 8 Version
SCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?
AutoSpec Premier Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements? Looking for sensitivity, selectivity and dynamic range? The AutoSpec Premier is the latest
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
25-4-2007 MALDI-MS Product overview 1 Company Instrument Benchtop (j/n)
25-4-2007 MALDI-MS Product overview 1 Voyager TM DE- PRO ja ja
INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,
High resolution mass spectrometry (HRMS*) in Graz
High resolution mass spectrometry (HRMS*) in Graz 10.2.2012 * Instruments with high resolution where exact mass measurements can be performed 1 HRMS in Graz s and Ionization Techniques 2 6 3 5 4 1 TU Graz
Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
8-9-2009 LC-MS Productenoverzicht 1 Leverancier (contactpersoon) Agilent Technologies (Martin Haex, afd. LSCA)
8-9-2009 LC-MS Productenoverzicht 1 Technologies Technologies - 6110/6120/6130/6140 LC-MS single quad -6224 LC-MS- TOF Single quad 2-3000 AMU ESI, nano ESI, APCI, APPI, Multi Mode ESI/APCI, chip LC, DART
Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
Thermo Scientific ConFlo IV Universal Interface
m a s s s p e c t r o m e t r y Thermo Scientific ConFlo IV Universal Interface The Universal Interface Part of Thermo Fisher Scientific ConFlo IV Universal Interface The Universal Interface The development
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250
API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
#5 - MUTE YOUR PHONE Upgrading your Lab to Windows 7? Server 2008?
#5 - MUTE YOUR PHONE Upgrading your Lab to Windows 7? Server 2008? Steve Miller Agilent Technologies Informatics Specialist Agenda What is OpenLAB? What are the products? What is the new Architecture?
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
GC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.
Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012 Introduction Screen captures in this document were taken from MassHunter B.05.00
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography
Waters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
WATERS QUANTITATIVE ANALYSIS solutions
More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
How To Use Gc-Ms
The CHROMacademy Essential Guide Understanding GC-MS Analysis Part 1 Speakers John Hinshaw GC Dept. Dean CHROMacademy Tony Taylor Technical Director Crawford Scientific Moderator M ( g ) e M ( g ) 2e Peter
MassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
QGA Quantitative Gas Analyser
QGA Quantitative Gas Analyser A compact bench-top system for real-time gas and vapour analysis Detailed product information / introduction catalysis studies environmental gas analysis fermentation off-gas
Tuning & Mass Calibration
Tuning & Mass Calibration 1 1 The Sample List Sample List Name Project Name 2 The sample list is the top level screen in the TurboMass Gold Software. Data storage is set up in PROJECT files and within
Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview
Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview Authors Xiaofei Ping Agilent Technologies (Shanghai) Co Ltd 412 Yinglun Road, Shanghai, 200131 P.R. China
Product information CHRONOS 4.1
Date: April 2014 the universal automation platform for chromatographic analytics Automation is an important topic in chromatographic laboratories. A decrease in the number of personnel and increasing requirements
aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS
aurora M90 A new era in ICP-MS Innovation with Integrity ICP-MS Your Partner in ICP-MS Solutions Bruker continues to find new and novel ways to meet your changing needs. As a leader in elemental analysis
Pesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Mark Belmont and Alexander N. Semyonov, Thermo Fisher Scientific, Austin, TX, USA Ming Gu, Cerno Bioscience,
How To Analyze Pesticide Levels In Lemon Oil
AppNote 9/2006 Target GC-MS Analysis using Accelerated Column Heating and Interactive Deconvolution Software Albert Robbat Tufts University, Chemistry Department, Medford, MA 02155, USA Andreas Hoffmann
C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer
C146-E087F GCMS-QP2010 Plus Shimadzu Gas Chromatograph Mass Spectrometer The performance you have been waiting for is here. GCMS-QP2010 Plus GCMS-QP2010 Plus Shimadzu Gas Chromatograph Mass Spectrometer
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide
Application of Structure-Based LC/MS Database Management for Forensic Analysis
Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application
Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT
AppNote 6/2003 Analysis of Flavors using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Kevin L. Goodner USDA, Citrus & Subtropical
UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Expectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will
EQuan MAX Getting Connected Field Service Guide
EQuan MAX Getting Connected Field Service Guide This guide provides procedures to connect the various components for the Thermo Scientific EQuan MAX automated high-throughput LC-MS system. Contents Hardware
LC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum
Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in uman Serum Technical verview Clinical Research Authors Anthony Macherone, Ph.D. Agilent Technologies,
Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific
Pesticide residue analysis: New Trends Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Why pesticide analysis? Extensively used in agriculture to control
amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database
C146-E175A Technical Report Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database Hitoshi Tsuchihashi 1 Abstract: A sample consisting
Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?
Mass spectrometry What are the principles behind MS? What do all MS instruments have in common? What are the different types of MS? Lecture outline: 1) Introduction to mass spectrometry 2) sample introduction
Analysis of Phthalate Esters in Children's Toys Using GC-MS
C146-E152 Analysis of Phthalate Esters in Children's Toys Using GC-MS GC/MS Technical Report No.4 Yuki Sakamoto, Katsuhiro Nakagawa, Haruhiko Miyagawa Abstract As of February 29, the US Consumer Product
RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH
RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH Cristiana C. Leandro 1, Peter Hancock 1, Christian Soulier 2, Françoise Aime 2 1 Waters Corporation, Manchester,
Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report
of melamine-ware by GC-MS and LC-MS/MS Page 1 of 15 Method development for analysis of formaldehyde in foodsimulant extracts of melamine-ware by GC-MS and LC-MS/MS December 2012 Contact Point: Chris Hopley
A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015
A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method
Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS-1603. No. SSI-GCMS-1603. Shilpi Chopra, Ph.D.
Gas Chromatograph Mass Spectrometer No. GCMS-1603 Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS Shilpi Chopra, Ph.D. Introduction Organophosphorus (OP) pesticides are a class
Micromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
Mass Frontier 7.0 Quick Start Guide
Mass Frontier 7.0 Quick Start Guide The topics in this guide briefly step you through key features of the Mass Frontier application. Editing a Structure Working with Spectral Trees Building a Library Predicting
The Use of Hydrogen Carrier Gas for GC/MS
Technical Note The Use of Hydrogen Carrier Gas for GC/MS Gas Chromatography/ Mass Spectrometry Highlights Guidelines that can mitigate dangers and leverage benefits of using hydrogen Key safety factors
CATALYSIS & THERMAL ANALYSIS
CATALYSIS & THERMAL ANALYSIS MASS SPECTROMETERS FOR CATALYSIS & THERMAL ANALYSIS HIDEN MS MASS SPECTROMETERS for Catalysis and Thermal Applications Hiden Analytical have been designing and developing the
Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes
Metabolomics Software Tools Xiuxia Du, Paul Benton, Stephen Barnes Outline 2 Introduction Software Tools for LC-MS metabolomics Software Tools for GC-MS metabolomics Software Tools for Statistical Analysis
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
MassLynx 4.1 Getting Started Guide
MassLynx 4.1 Getting Started Guide 71500113203/Revision A Copyright Waters Corporation 2005. All rights reserved. Copyright notice 2005 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA AND IRELAND.
Background Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry
ProteinScape Proteomics Data Analysis & Management Innovation with Integrity Mass Spectrometry ProteinScape a Virtual Environment for Successful Proteomics To overcome the growing complexity of proteomics
Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port
APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory
Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M
Bruker Daltonics Application Note # MS- Fast n-site Identification of Drugs with the mobile GC/MS system E²M For the detection of drugs a couple of quick tests are available which were used by the police
The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies
The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies INEF Penn State Conference 2013 Albert Robbat, Jr. and Patrick Antle Tufts University, Chemistry
AxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
Clarus 580 Gas Chromatograph
S P E C I F I C A T I O N S Gas Chromatography Clarus 580 Gas Chromatograph The PerkinElmer Clarus 580 Gas Chromatograph (GC) is a fully automated gas chromatograph. The system offers the capabilities
NIST Standard Reference Database 1A
NIST Standard Reference Database 1A NIST/EPA/NIH Mass Spectral Library (NIST 08) and NIST Mass Spectral Search Program (Version 2.0f) For Use with Microsoft Windows User s Guide The NIST Mass Spectrometry
PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW
OVERVIEW Exact mass LC/MS analysis using an orthogonal acceleration time of flight (oa-tof) mass spectrometer is a well-established technique with a broad range of applications. These include elemental
Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow
Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow Abstract There is high demand in clinical research and forensic toxicology for comprehensive,
Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible
Multi-Shot Pyrolyzer EGA/PY-3030D Flexible Versatile Reproducible Why Evolved Gas Analysis? Why Pyrolysis? Today, analytical pyrolysis encompasses much more than simple flash pyrolysis of polymeric materials.
Setting up a Quantitative Analysis MS ChemStation
Setting up a Quantitative Analysis MS ChemStation Getting Ready 1. Use the tutorial section "Quant Reports" on the MSD Reference Collection CD-ROM that came with your ChemStation software. 2. Know what
Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform
Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform Remco Swart Pittcon March 8-12, 2015 1 The world leader in serving science Outline Thermo Scientific Vanquish UHPLC
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS
aurora ICP-MS The Science of Sensitivity Innovation with Integrity ICP-MS Powers the Business of Quantification aurora ICP-MS enhanced value package Bruker s ICP-MS is famous for its innovative and unique
Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests
Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests AB SCIEX TOF/TOF 5800 System with DynamicExit Algorithm and ProteinPilot Software for Robust Protein
SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *
SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING * Wolfgang WEINMANN 1, Natalie LEHMANN 1, Michaela RENZ 1, Alexander WIEDEMANN 1, Michal SVOBODA 2 1 Institute of
Aiping Lu. Key Laboratory of System Biology Chinese Academic Society [email protected]
Aiping Lu Key Laboratory of System Biology Chinese Academic Society [email protected] Proteome and Proteomics PROTEin complement expressed by genome Marc Wilkins Electrophoresis. 1995. 16(7):1090-4. proteomics
The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success.
The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success. Introducing the Agilent 7890A Gas Chromatograph. Step up to a higher level of GC reliability, productivity
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
Micro Cryo-Trap Model 971
Micro Cryo-Trap Model 971 for Liquid CO2 Cooling Scientific Instrument Services, Inc. 1027 Old York Road Ringoes, NJ 08551 Phone (908) 788-5550 Part #951001M revised 10/ /98 Notice The information in this
5973 inert Mass Selective Detector
5973 inert Mass Selective Detector Hardware Manual Agilent Technologies 5973 inert Mass Selective Detector Hardware Manual Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced
Analyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
Analysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs
GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs Kinet C, De Pauw E, Focant JF CART, Mass Spectrometry Laboratory, Chemistry Department, University of Liège, Allée de la Chimie 3,
Mass Spectrometry. Overview
Mass Spectrometry Overview Mass Spectrometry is an analytic technique that utilizes the degree of deflection of charged particles by a magnetic field to find the relative masses of molecular ions and fragments.2
Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS
c h r o m a t o g r a p h y Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS The Next Evolution in GC Triple Quadrupoles Higher Sample Throughput Higher Productivity Detection Limits Beyond