PROFIBUS Diagnostics and Network Monitoring Tools



Similar documents
PROFIBUS diagnostics and network monitoring

PROFIBUS DP Diagnostics and Network Monitoring Tools

Top Level Design of Automation and Control Systems

PROFIBUS fault finding and health checking

PROFINET IO Diagnostics 1

PROFIBUS/PROFINET System design

PROFINET Diagnostics Software and Tools

Introduction to PROFIBUS and PROFINET

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Process automation engineering tools

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Integrating HART into PROFIBUS DP

Masterclass Maintenance & Management

Introduction to the Actuator Sensor-Interface

PROFIBUS. Design and. Good Practices

Conditie gebaseerd onderhoud met PROFIBUS in overeenstemming met NAMUR NE107

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

Software Release Notes - FieldConnex Diagnostic Manager

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Universal Adapters for Remote Monitoring

DCM. Product Brochure. Diagnostic Communication Master

remote I/O future inside

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Wireless Sensor Networks

Partner for automation Water technology

Intelligent Fieldbus Keeps your Process Running

Power network telecommunication

MOTION COORDINATOR MC206X Quick Connection Guide

obems - open source Building energy Management System T4 Sustainability Ltd

Industrial Training Schedule Spring 2012

Real pioneers don t know where to stop: Hirschmann explosion protection technology for hazardous locations.

Industrial Requirements for a Converged Network


1 How configure S7 PLC in the configuration tool

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

SIMATIC PDM software. Siemens FI /1

PROFIBUS AND MODBUS: A COMPARISON

Process Alarm Solutions

EtherCAT Cutting Costs with High-speed Ethernet

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

Introduction To SCADA and Telemetry

Parameterization, Configuration and Visualization with SIRIUS

Where s the Interoperability for Asset Management?

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Analysis of Industrial PROFINET in the Task of Controlling a Dynamic System**

Technical Information POWER PLANT CONTROLLER

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Ponto Series. A new concept for automation

TAXONOMY OF TELECOM TERMS

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

Power Generator Switching for Power Engineers Inc. with. Distrix Software Defined Infrastructure. A Distrix Networks Case Study.

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Development of a Gateway to PROFIBUS for Remote Diagnostics

Monitoring & Control of Small-scale Renewable Energy Sources

ABB RTU560A Series CMU & Modules

CANtrol EC Modular Control System Powerful and versatile

Fieldbus slave modules with I/Os, DIO

White paper The future role of ethernet and the trend to decentralised control solutions

NJ Programming Best Practices

PLCs and SCADA Systems

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

CB15/CB155. PROFIBUS Module

Everything you ever wanted to know about DPV1 diagnostics but were afraid to ask!

DS-6 Intercom System Introduction

MULTIPORPUSE PRESS CONTROL AND FORCE VS DISPLACEMENT MONITORING SYSTEM

Automation Networks. Mitsubishi Electric Automation, Inc. Discover the Many Facets of Mitsubishi Electric. The Power in Automation Solutions.

C o v e r. Thin Client Application Options. SIMATIC Thin Client s FAQ h April 2009 e et. Service & Support. Answers for industry.

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Modicon M340 The all-in-one PAC

Eight frames in three different sizes provide stylish and practical housing for the Crystal Vision modular product range

TX2123 RS485 TO ETHERNET ADAPTOR

Chameleon MOVA INTELLIGENT COMMUNICATION OUTSTATION

Validation of PROFINET plants

applicomio Profibus-DP

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Early Warning Fire Detection and Integrated Security Solution. System Overview

Monitoring and diagnostics. Field data integration to control room solution guide

Ways to Use USB in Embedded Systems

INBLOX. Intelligent modulare diagnostic repeater. We structure your network

Configuring PROFINET

Wir kriegen s geregelt Close the loop with PMA

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

EVALUATION OF ALTERNATIVE BACKUP PROTECTION SCHEMES ON A 66KV DISTRIBUTION NETWORK

Realize more value from System 800xA Apply Asset Management for more benefits

Electric actuators. with fieldbus interface. Information

Private Modbus Serial Bus Functionality via DeviceMaster UP Modbus Router

Transcription:

PROFIBUS Diagnostics and Network Monitoring Tools Andy Verwer Verwer Training & Consultancy Ltd Dave Tomlin Hitex (UK) Ltd

Outline of Presentation Briefly look at the types of problems that commonly occur in PROFIBUS systems. Examine the need for and benefits of network health checking. Briefly explore the types of standardised diagnostics in PROFIBUS systems. Dave Tomlin and myself will then discuss various state of the art fault finding and health checking tools from Softing, Pepperl & Fuchs and Procentec. You can then spend time exploring these tools and our network using the laptops provided. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 2

PROFIBUS PROFIBUS is a very reliable and cost effective technology. It is common to find extensive installations comprising thousands of PROFIBUS devices operating on complex networks which are connected together via industrial Ethernet. The reliable operation of these networks is essential to maintaining plant productivity. So, what can go wrong? PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 3

The Most Common Netwok Problems Configuration faults. Addressing faults. PLC Ethernet PC Number 1 Wiring faults: Reflections, Wire breaks, Short circuits, connector corrosion or failure etc.? PSU HMI PROFIBUS DP Instrument or I/O failure PROFIBUS DP PROFIBUS PA Number 2 Interference pickup, Particularly from drives and servos. Power supply failure. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 4

Fault categorisation These faults can be categorised in several ways: Communication faults Peripheral faults These are Bus Faults E.g. network wiring errors, interference pickup, reflections etc. Communication is disrupted. Concerned with the sensor or actuator. E.g. sensor wire break, loss of output power, sticking valve etc. Devices are still communicating. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 5

Communication faults Communication faults can be diagnosed using tools such as: Protocol analysers and diagnostic tools. Waveform visualisation tools such as oscilloscopes etc. Communication errors do not always produce loss of control. This is because PROFIBUS is very robust to errors that can corrupt communication data. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 6

Communication faults Quite often users are unaware that their system has communication errors because the robustness of PROFIBUS can hide these faults. Green light all must be ok! PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 7

Communication faults Quite often users are unaware that their system has communication errors because the robustness of PROFIBUS can hide these faults. Green light Oh all %&#@! must be ok! Only when the rate of data corruption reaches a critical threshold will the fault become visible. But then it is too late we have lost production. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 8

Peripheral faults Because the communication remains operational, peripheral faults can often be located and diagnosed using the communications system itself. Tools and techniques that are useful for locating peripheral faults on PROFIBUS systems include: Diagnostic reporting using on line system diagnostics. Engineering tools, protocol analysers, etc. Modern intelligent devices incorporate self diagnostic features that can identify and highlight peripheral faults. However, tools are still required to access these extended diagnostics. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 9

Intermittent Faults Permanent faults are relatively easy to fix. Because the fault disappears when we've fixed it! Intermittent faults can be a nightmare! Because we cannot be sure that we have fixed it. We may seem to have cured the problem, but then it comes back again later! Intermittent faults require long term monitoring to check that the fault is cured. Statistical reporting over an extended period can be useful. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 10

Standard PROFIBUS diagnostics Every PROFIBUS device provides a block of standard diagnostics, which provides information on the health of the device. Standard diagnostics gives information on the device and the state of communications. Standard diagnostics are generally useful for diagnosing communication faults. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 11

Communication Faults Mainly caused by poor network wiring or layout or cable/connector deterioration. Can be permanent or intermittent. Bus Fault light on when watchdog timer trips out Watchdog takes time, and so BF light may not show when errors are intermittent. SF BF #41 System diagnostics: Station 41, Communication failure, invalid response. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 12

Extended PROFIBUS diagnostics Extended diagnostics can provide information on peripheral errors. Peripheral diagnostics are an important part of a successful fault finding and maintenance strategy. Extended diagnostics are sent together with the standard diagnostics in the same telegram. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 13

Peripheral faults Typically caused by sensor/actuator failure or wiring faults. Again faults can be intermittent. System Fault light shows peripheral errors Note: Bus Fault shows communications is OK. SF BF #41 System diagnostics: Station 41, module 2, Input channel 1, Wire break. Sensor PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 14

System Health Checking Health checking is an important part of the commissioning and maintenance strategy for your plant. The health check will help to find non critical and intermittent faults that are not obvious. A health check should be carried out immediately after commissioning. We also strongly recommend repeating the health check at intervals. How much better to integrate the health checking tools into the network? To give permanent monitoring of system health. Automatically report failures. Give pre warning of impending failures and performance degradation. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 15

Permanent monitoring tools A number of new tools have appeared on the market which are designed to be permanently connected to the network to provide 24/7 network monitoring. Softing TH LINK PROFIBUS monitor Pepperl+Fuchs ADM PA segment monitor (up to four segments) Procentec COMbricks DP and PA network monitor (up to four networks, 20 segments) PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 16

The ADM provides remote monitoring of PROFIBUS PA communications including waveform visualisation, jitter measurement and statistics. Used in conjunction with the P+F modular coupler system, it allows up to four PROFIBUS PA segments to be monitored via FDT tools such as PactWare or FieldCare. Pepperl+Fuchs Advanced Diagnostics PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 17

COMbricks COMbricks is a modular repeater and gateway system from Procentec with built in ProfiTrace functionality accessible over Ethernet. COMbricks provides: Networking PROFIBUS DP and PA, PROFINET, Ethernet, copper and fibre optic. Monitoring ProfiTrace OE builtin and accessible over Ethernet (web based). Control Remote IO capability allowing low cost control and plant monitoring over the network. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 18

COMbricks The Modules available include: Head Station with ProfiTrace built in Repeater modules with optional scope and redundancy PA module Coupler and/or MBP monitor with scope Optical link modules (1 or 2 channel) PROFIBUS DP slave modules PROFINET IO device modules IO modules digital, relay, analogue etc mix and match to produce the required functionality PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 19

Example Ethernet Head Station ProfiTrace Analyser built in to the head station. Can monitor all 4 segments over Ethernet. Provides diagnostics and health checking via a web browser and plant asset management via FDT tools such as PactWare or FieldCare. 2 channel repeater modules Each of the four segments can have up to 31 devices connected. But each channel could be connected to a separate network if desired allowing up to 4 networks to be monitored simultaneously. Each network can run at a different bitrate and can have many DP (RS485), PA (MBP) or Fibre Optic segments. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 20

TH Link PROFIBUS TH Link provides controller independent access to PROFIBUS networks for plant operation and maintenance staff. Giving both network diagnostics via a web browser and plant asset management via FDT tools such as PactWare or FieldCare. PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 21

TH Link PROFIBUS Live List Inventory with particulars of devices for replacement and management Diagnostic List with diagnostic suggestions Configuration via PACTware or Fieldcare PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 22

TH Scope Monitor multiple TH Links, for PROFIBUS, PROFINET, Industrial Ethernet, etc. Trend analysis Live List, Statistics and inventory Email updates in case of issues PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 23

Master COMbricks 1 1 chan. DP repeater + PA coupler Our PROFIBUS Network Wireless Ethernet hub VTC COMbricks TH Link Segment 3 PA Rack 1 Segment 1 DP Segment 2 DP Rack 4 Rack 2 Segment 4 PA COMbricks 2 2 chan. DP repeater + PA coupler Rack 3 PROFIBUS Diagnostics & Monitoring, Andy Verwer, Dave Tomlin Page 24