Spectral distribution from end window X-ray tubes

Similar documents
CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Lectures about XRF (X-Ray Fluorescence)

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

D FUNDAMENTALS AND PRACTICE OF XRF ANALYSIS

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

XRF MAPPING: NEW TOOLS FOR DISTRIBUTION ANALYSIS

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

EDXRF of Used Automotive Catalytic Converters

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Introduction to Energy Dispersive X-ray Spectrometry (EDS)

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Tutorial 4.6 Gamma Spectrum Analysis

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

GAMMA-RAY SPECTRA REFERENCES

THEORY OF XRF. Getting acquainted with the principles. Peter Brouwer

BORON IN GLASS DETERMINATION USING WDXRF

Spectra of pyroelectric X-ray generator

Coating Thickness and Composition Analysis by Micro-EDXRF

X Ray Flourescence (XRF)

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Introduction to Geiger Counters

Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist

X-ray Techniques: Overview. Ron Jenkins

Glancing XRD and XRF for the Study of Texture Development in SmCo Based Films Sputtered Onto Silicon Substrates

Preface Light Microscopy X-ray Diffraction Methods

BRUKER ADVANCED X-RAY SOLUTIONS GUIDE TO XRF BASICS

X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING

Field portable XRF analysis of environmental samples

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

Generation of X-Rays (prepared by James R. Connolly, for EPS , Introduction to X-Ray Powder Diffraction, Spring 2005)

Supporting Information

GRID AND PRISM SPECTROMETERS

X-RAY DIFFRACTION IMAGING AS A TOOL OF MESOSTRUCTURE ANALYSIS

Crystal Structure of High Temperature Superconductors. Marie Nelson East Orange Campus High School NJIT Professor: Trevor Tyson

Energy Dispersive Spectroscopy on the SEM: A Primer

Introduction to Powder X-Ray Diffraction History Basic Principles

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

PARALLEL BEAM METHODS IN POWDER DIFFRACTION AND TEXTURE IN THE LABORATORY.

2 Absorbing Solar Energy

Does Quantum Mechanics Make Sense? Size

Supporting Information

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

X-Ray Fluorescence Analytical Techniques

Quantitative Analysis Software for X-Ray Fluorescence. XRF-FP is a full-featured quantitative analysis package for XRF

High-resolution bio-imaging with liquid-metal-jet x-ray sources

X-ray Diffraction (XRD)

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

CHAPTER 7 SCINTILLATION COUNTING

Wir schaffen Wissen heute für morgen

Electron spectroscopy Lecture Kai M. Siegbahn ( ) Nobel Price 1981 High resolution Electron Spectroscopy

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

3 - Atomic Absorption Spectroscopy

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Extended spectral coverage of BWO combined with frequency multipliers

Copyright by Mark Brandt, Ph.D. 12

Electron Microprobe Analysis X-ray spectrometry:

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

Light as a Wave. The Nature of Light. EM Radiation Spectrum. EM Radiation Spectrum. Electromagnetic Radiation

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

D.S. Boyd School of Earth Sciences and Geography, Kingston University, U.K.

The Phenomenon of Photoelectric Emission:

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

SphinX:A Fast Solar Photometer in X-rays. J. Sylwester 1,, S. Kuzin 2, Yu. D. Kotov 3, F. Farnik 4 & F. Reale 5

Radiation Strip Thickness Measurement Systems

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

Chemistry 102 Summary June 24 th. Properties of Light

Experiment #5: Qualitative Absorption Spectroscopy

The accurate calibration of all detectors is crucial for the subsequent data

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye

The study of structural and optical properties of TiO 2 :Tb thin films

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

Radiation Detection and Measurement

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Portable X-ray fluorescence Spectroscopy. Michael A. Wilson Research Soil Scientist USDA-NRCS National Soil Survey Center Lincoln, NE

Gamma and X-Ray Detection

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

ANALYSIS OF LEAD IN CANDLE PARTICULATE EMISSIONS BY XRF USING UNIQUANT 4

Silicon Drift Detector Product Brochure Update 2013

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

DYNAMICS OF MOMENTUM DISTRIBUTIONS OF VACUUM EXCITATION IN FOCAL SPOT OF MODERN SUPER-POWER LASERS COUNTER BEAMS

Rigaku XRD-System Instruction Manual v4/19/03. The Krishnan Group/Wilcox 132, University of Washington

Scanning Electron Microscopy: an overview on application and perspective

Time out states and transitions

E/M Experiment: Electrons in a Magnetic Field.

Preview of Period 3: Electromagnetic Waves Radiant Energy II

X-Ray Study of Soft and Hard Magnetic Thin Films

Theremino System Theremino Spectrometer Technology

ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante

Raman spectroscopy Lecture

Transcription:

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 393 Spectral distribution from end window X-ray tubes N. Broll 1, P. de Chateaubourg 2 1 FORTEX - E.N.S.A.I.S. 24, bld de la Victoire, 67084 STRASBOURG Cedex, France 2 UPVM - 61, av. du Gal de Gaulle, 94010 CRETEIL Cedex, France ABSTRACT Today little information still exists on spectra profiles emitted by x-ray tubes, although the development of mathematical matrix correction procedures for x-ray fluorescence analysis showed the demand of the knowlegde of accurate spectral intensity distribution from x-ray tubes. In this paper we present measured spectral intensity distributions from end window x-ray tubes (Au, Rh, Cu and Cr anodes) typically used in wavelength and energy dispersive spectrometers. The spectral distribution of the x-ray tubes measured with an energy dispersive method allows to compare the experimental data of the continuous spectra of the x-ray tube to a semiempirical expression based on the Kramers law. Furthermore, the knowlegde of different x-ray lines contributes to the total x-ray spectral distribution. INTRODUCTION In the quantitative analysis of elements by x-ray fluorescence techniques, it is essential to know the contribution of the continuous spectra to the excitation of the fluorescence lines relative to that excited d by characteristic lines of the excitation beam. Modern x-ray generators are still built around the Coolidge tube, i.e. vacuum tube in which electrons are emitted by an heated W filament (cathode), accelerated by high voltage and focused on a water-cooled metal target (anode). Electron bombardement of solid targets is the most usual method to generate x-rays represented by spectral distributions of x- ray photons. These spectral distribution consist of a continuous spectrum (due to the Bremsstrahlung) on which are superposed a few characteristic lines depending on the target element. Spectral intensity distributions from x-ray tubes show that the continuous component is far from being negligible; the continuous spectrum represents 30 to 70% of the total intensity which is composed of this continuous spectrum and the anode s characteristic lines. It is surprising that it was long considered that the continuous spectrum was described by the Kramers law, while this law concerns the x-ray inner generation by electrons and not the x-rays leaving the anode or tube s window. Before 1970, no discontinuities were reported due to the continuous spectrum s selfabsorption in the anode. Since 1968, the accurate spectral intensity distribution from x-ray tubes became more and more important for developing the fundamental parameter method. In these time new and more accurate measurements were realized. Important deviations between the experimental spectral distributions and the one given by Kramer s law were reported. These works were not carried on consequently, and therefore there exist only a few publications of which the most are principally devoted to former types of X-ray tubes. Up to now, no systematic study was carried out, although we know that the spectral distribution shape depends on the X-ray tube geometry. Figure 1 shows measured spectral distributions for different types of X-ray tubes. The shape of the spectral distributions can be explained by a theory based on electron transmission. However, this theory is too elaborate to apply. Therefore, experimental measurements and semi-empirical relations are preferred nowadays. 1

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 394 Fig. 1 measured spectral distributions for different types of X-ray tubes EXPERIMENTAL METHODS Different methods have been used to measure spectral distributions. The first of these methods has been used by many authors assuming that the spectrum, obtained by X-ray scattering by an organic sample agreed with real tube s spectrum. Is difficult to fit such a spectrum to the real distribution. The exploitation of such a spectrum needs a lot of corrections. 2

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 395 Another method to study spectral distributions consists in exploiting spectra measured by an electronic microprobe, but again, results do not exactly match with reality. Furthermore, there exists two other experimental methods which allow to determine correctly the spectral distribution. The radiation at the exit of the tube is measured directly with a spectrometer, either wavelength or energy dispersive. Figure 2a,b represent the scheme of these experimental assemblies.these two methods also need corrections to link the measured x-ray intensity with x-ray intensity effectively emitted by the tube: Fig. 2a,b Schemes of the experimental assemblies Wavelength dispersion - analysing crystal reflectivity - detectors (scintillation and flow counters) efficiency - pulse heigth analysis - supression of higher order reflections - mylar window between detector transmisson - loss of counts due to the dead time of the detector - total spectrum reconstitution from measurements with different analysing crystals Energy dispersion - detector quantum yield - detector background - excape peaks - compton effect in the detector - pile-up peaks - interference of fluorescence lines due to the spectrometer s resolution 3

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 396 EXPERIMENTAL RESULTS Measurements have been realized using the energy dispersion method, which is more easy to handle. After corrections, we record results in a table where intensity measured is noted for different excitation voltages. A full spectrum can be expressed as a distribution N(E)dE, where N(E) is the number of accumulated counts corresponding to x-ray photon energies between E and E+dE. Since wavelength is inversely proportional to energy (λ=12.3981/e), dλ=-(12.3981/e 2 )de N(E) can be written as N(E)dE=N(λ)dλ where N(λ)=N(E)E 2 /12.3981. Measurements have been made on front end window tubes (Beryllium windows thickness of 125µm) used for Siemens SRS303 spectrometers. Au, Rh, Cr and Cu anodes were studied. Figures 3,4,5,6 represent spectral distributions of the continuous spectra for different excitation voltages. Fig 3. Spectral distribution of the continuous spectra of an Au tube for different excitation voltages 4

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 397 Fig 4. Spectral distribution of the continuous spectra of a Cu tube for different excitation voltages Fig 5. Spectral distribution of the continuous spectra of a Rh tube for different excitation voltages 5

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 398 Fig 6. Spectral distribution of the continuous spectra of a Cr tube for different excitation voltages We note for the Au tube, discontinuities of absorption for M shells can not be seen, although characteristic lines are detected. This is due to the difficulty to obtain an accurate measurement in the discontinuity area because, first, the superposition of intense characteristic lines and second the poor detector resolution at low energies. In practice, this imprecision is negligible, since characteristic lines are widely prevalent. Fig 7 accounts for continous spectra importance according to the tube s target for the same excitation voltage (here e.g. 40 kev). 6

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 399 Fig 7. Continous spectra according to the tube s target for the same excitation voltage (40 kev). We note that these experimental results can be used in order to fit the data to the semi-empirical equation: λ q 1 n N( λ) ( 1) exp( Q µ, )exp( 2 A λ µ Be, λ ρ λ λ 0 Be d) The first term agrees with the Kramers law, modified by the exponent q. The second term represents the radiation self absorption in the target, where the coefficients Q and n account for the mean depth electrons penetration in the target. Finally, the third term expresses the x-ray absorption by the beryllium window. Q, n and q are fitted by a reiterative process until variations between theoretical and experimental graphs become a minimum. For example, for an excitation voltage of 50 kev, we obtain following coefficients ( n is kept constant to 1): 7

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 400 Tube q Q Cr 1.502 0.00127 Cu 1.491 0.00144 Rh 1.426 0.00096 Au 1.206 0.00041 CHARACTERISTIC LINES We have measured Kα, Kβ lines of Cr and Cu tubes, L lines of Rh tube and Lα, Lβ, Lγ, Ll and M lines of Au tube. Figure 8 represents measured intensity evolution for each characteristic line as a function of the exciting voltage. Fig. 8 Measured intensity evolution for each characteristic line as a function of the exciting voltage We have represented in table 1 these characteristic lines leaving the x-ray tubes, at different voltages, that is, after all corrections required by the energy-dispersive method. Results are expressed in per cent in respect to the total spectrum (Bremsstrahlung plus characteristic lines) 8

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 401 [kv] 20 25 30 35 40 45 50 Cr tube Brems. 34.09 31.10 29.60 28.02 25.73 26.53 26.84 K α 57.92 60.54 61.64 63.18 65.15 64.45 64.23 K β 7.99 8.36 8.76 8.80 9.12 9.02 8.93 Cu tube Brems. 58.41 51.64 47.27 44.97 43.64 41.45 39.08 K α 36.52 42.50 46.38 48.49 49.59 51.44 53.42 K β 5.07 5.86 6.35 6.54 6.77 7.11 7.50 Rh tube Brems. 55.82 54.73 55.07 55.07 53.57 54.82 55.21 L 44.18 54.27 44.28 43.47 43.88 41.41 39.74 K α 0.55 1.25 2.16 3.21 4.21 K β 0.10 0.21 0.40 0.57 0.84 Cr tube Brems. 71.79 69.19 67.01 65.36 63.97 63.76 63.39 M a,b 21.80 19.45 17.54 15.78 14.47 12.83 11.97 Mn4 0.51 0.38 0.34 0.23 0.26 0.21 0.21 L l 0.16 0.37 0.42 0.52 0.60 0.64 0.64 L α 3.71 6.45 8.70 10.46 11.90 12.72 13.37 L β 1.87 3.80 5.26 6.72 7.68 8.60 9.22 Lγ 0.15 0.37 0.72 0.93 1.12 1.24 1.19 Table 1 Characteristic line intensities leaving the X-ray tubes at different voltages Figure 9 illustrates these variations in per cent as a function of the exciting voltage for each X-ray tube. 9

Copyright (C) JCPDS-International Centre for Diffraction Data 1999 402 Fig. 9 Variations of the characteristic line intensities in per cent as a function of the exciting voltage CONCLUSION Our collected spectral data are used in different software packages with fundamental parameter coefficients method. It is interesting to know the importance of different x-ray lines in order to determine their contributions to element analysis. In practice, the accuracy of the results is widely satisfied. In order to have more accurate measurements, it will be necessary to measure the discontinuities area (at low energies) by energy and wavelength dispersive method, and then to adjust the two measured spectra. Furthermore, it will be possible to realize a statistical study for determine the reliability of this method (exactness). We finally note that the spectral distribution does not remain constant during the x-ray tube lifetime. Characteristics can change by ageing and impurities. REFERENCES 1. H.A. Kramers, Philo. Mag. 46, 836 (1923) 2. C.T. Ulrey, Phys. Rev. 11,401 (1918) 3. H. Kulenkampff, Ann. der Phys. 69, 548 (1922) 4. H. Kulenkampff, L. Schmidt, Ann. der Phys. 43, 494 (1943) 5. J.W. Criss, L.S. Birks, Anal. Chem 40, 1080 (1968) 6. J.V. Gilfrich, L.S. Birks, Anal. Chem 40, 1077 (1968) 7. D.B. Brown, J.V.Gilfrich, M.C. Peckerar, J. Appl. Phys. 46, 4537 (1975) 8. T.C. Loomis, H.D. Keith, X-ray Spectrom. 5, 104 (1976) 9. N. Broll, X-ray Spectrom. 15, 271 (1986) 10. T.Arai, T. Shoji, K. Omote, Adv in X-ray Analys 29, 413 (1985) 11. R. Görgl, P. Wobrauschek, P. Kregsamer, C. Streli, X-ray Spectrom. 21, 37 (1992) 12. R.O. Müller, Spektrochemische Analysen mit Röntgenfluoreszenz, Oldenbourg, Munich (1967) 13. P.A. Pella, L. Feng, J.A. Small, X-ray Spectrom. 14, 125 (1985) 14. R. Tertian, N. Broll, X-ray Spectrom. 13, 134 (1984) 15. N. Broll, R. Tertian, X-ray Spectrom. 12, 30 (1983). 10