Technical catalogue convectors POLAND 2012



Similar documents
Technical catalogue panel radiators POLAND 2014

HDA

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Integral Kit Instructions

1. Geo Vertical 2. Geo Horizontal

Low-H2O valves Y EARS

How To Build A Brugman Compact Radiator

Thermostatic Actuators

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Thermostats. Technical information

Brochure EX

stainless steel pre-assembled manifolds

Luxor. Automatic retractable bollard

DSRQ - DSRSQ - DSRSQ-THERM

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

The space saving solution.

SERVER ROOM CABINET INSTALLATION CONCEPTS

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

HERZ-Thermal Actuators

How To Buy A Designo Grille

Data Centre Solutions

Slides and Drawers. The right collection

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

BEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

How To Use A Power Supply On A Powerline 2.2 (Ai)

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Select Radiators Installation Guide

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Data sheet Thermostatic sensors type RA 2000

Mikrotherm. Manual radiator valves. To be precise.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

Radiator valve accessories

BLADE S-MAX Cabinet for Blade Server

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

DE Frame with C Series Sidelight

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

PB accessories. PB accessories. Labelling option. Order Information B Printed board handle A BZA42727 BZA42724.

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

play Playful warmth, colourful comfort

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

UNIVERSAL RAILING, STEEL

All-Season Sunroom Sliding Glass Door Installation Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Product catalogue, pipe and sewer cleaning systems

Brochure EX

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

Digital inductive conductivity transmitter

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

5 axle Lowbed Semitrailer with Automatic Steering Model ST L3. (Lowbed length approx. 14,000 mm) Technical Specification no.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

MONDOATHENS BASKETBALL SET (Reference PK110)

Mounting Printed Circut Boards (PCB) Toll Free: (US & Canada) Fax: info@protocasedesigner.com

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Aluminium systems profile selection

Linkeo 19" freestanding cabinets

Powers Controls TH 192 S Single Temperature Room Thermostat

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Installation Instructions

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

K17.12 Door closers K17. Doors

CELO5. User & Installation Manual.

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Knürr Smaract. Knürr Smaract. CompactRack

BIS Gulv / Radiator Beslag

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

2013 Wireless Video Intercom INSTALLATION GUIDE

Aludesign K A T A L O G

ECOplus Solar Cylinder

Operators manual Basic water heater

Under sill units. Type FSL-B-ZAS

DELTA3-1. Delta 3 Data Centre Rack Solution

Morgue refrigeration unit

High Performance Visible Laser Diode Scanners

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CONTROL DESK SOLUTIONS

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

Industrial infrared heater IR For premises with large volumes and high ceilings

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

19" Open Rack for Network and Cabling Management

MONITOR MOUNTS. Monitor Arms OVERVIEW. Space saving benefits. Collaboration benefits. Performance benefits

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Transcription:

Technical catalogue convectors POLAND 2012

index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne VT... 27 mounting distances for Narbonne V...28 mounting distances for Narbonne V VT... 29 conversion table... 30 hydraulic characteristics for Narbonne VT and Narbonne V VT... 31 order codes... 32 selection tables for stands... 34, 36 selection tables for wall brackets... 35, 37 accessories...38 colours...42 2

Type review convectors Narbonne 4 connections height [mm]: 70, 142, 214, 286 length [mm]: 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000, 3200, 3400, 3600, 3800, 4000 Narbonne VT 5 connections height [mm]: 142, 214, 286 length [mm]: 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000, 3200, 3400, 3600, 3800, 4000 Narbonne V 4 connections height [mm]: 1600, 1800, 2000, 2200 length [mm]: 142, 214, 286, 358, 430, 502, 574, 646, 718, 790, 862 example of s NA 11 NA 22 NA 34 example of s NA 11 NA 22 NA 34 s NV 10 NV 11 NV 20 NV 21 Narbonne V VT 6 connections height [mm]: 1600, 1800, 2000 length [mm]: 214, 286, 358, 430, 502, 574, 646, 718, 790, 862 s NV 10 NV 11 NV 20 NV 21 3

convectors Narbonne Convectors Narbonne are composed of several interconnected profiled steel heating elements of a rectangular cross section. Each convector has got four connecting openings, each with internal thread G ½, enabling side connection, both from the left- and the right-hand side. Narbonne convectors are equipped with two side covers and the top masking grille. The heating profiles are mounted horizontally, so that to retain the 2 mm-wide distancing between each two, necessary to compensate for the heat expansion of the elements, and enabling the perfect varnish cover of the entire convector s surface. Most models are equipped with convective elements, increasing the heating efficiency of the convectors. technical specification Material : high quality steel profiles of a rectangular cross section, dimensions: 70 x 11 x 1.5 mm (high pressure version: 70 x 11 x 2.0 mm) Metal sheet thickness : heating profiles 1.50 mm; convectors 0.50 mm Height : 70, 142, 214, 286 mm Length : from 500 up to 4000 mm Depth : from 68 up to 339 mm Connections : 4 x G ½, side connectors Max. operating pressure : 5 bar for the standard version, 8 bar for the high pressure version Max. temperature : 110 C Colour : RAL 9016, other RAL colours available, surcharge at each order Brackets : wall or floor ordered separately, at Client s preference Accessories : plug and air vent, included in the convector s kit 4

Narbonne convectors front view side view L 20 H = 286 142 214 142 70* H- 40** 70* 20 20 20 19 * only cross connection possible ** not applicable to the 70 mm-high convector H - height [mm] L - length [mm] 20 214 20 286 top view NA 11 26 NA 35 NA 46 257 129 NA 23 NA 58 NA 34 175 104 150 232 68 104 NA 22 47 47 129 339 weight and water volume weight : kg/m height [mm] 70 142 214 286 11 - - 11.1 14.5 22 7.3 14.0 20.6 27.2 23 9.2 17.0 24.8 32.7 34 12.7 23.9 35.2 46.4 35 14.5 27.0 39.4 51.9 46 18.0 33.9 49.8 65.6 58 23.4 43.9 64.3 85.8 water volume : l/m height [mm] 70 142 214 286 11 - - 1.7 2.2 22 1.1 2.2 3.3 4.4 23 1.1 2.2 3.3 4.4 34 1.7 3.3 5.0 6.7 35 1.7 3.3 5.0 6.7 46 2.3 4.5 6.8 9.1 58 2.8 5.7 8.5 11.4 5

convectors Narbonne - height 70 mm An example of the convector NARBONNE 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE 22 70 1600 47 name height length L length [mm] parameters t z / t p / t i 22 23 34 35 46 58 212 262 331 405 500 111 138 180 215 254 314 397 485 600 133 165 216 257 297 367 463 566 700 155 1 252 300 339 419 529 647 800 177 220 288 343 382 472 595 728 900 200 248 324 386 424 524 661 809 1000 222 275 360 429 466 576 727 890 1100 244 303 396 472 509 629 7 971 1200 266 330 432 515 551 681 859 1052 1300 288 358 468 558 594 734 925 1133 1400 310 386 504 601 678 838 1058 1294 1600 354 440 576 687 763 943 1190 1456 1800 399 495 648 773 848 1048 1322 1618 2000 443 551 720 859 3 1153 1454 1780 2200 488 606 792 945 1018 1258 1586 1942 2400 532 661 864 1031 1102 1362 1719 2103 2600 576 716 6 1116 1187 1467 1851 2265 2800 620 771 1008 1202 1272 1572 1983 2427 3000 665 826 1080 1288 1357 1677 2115 2589 3200 709 881 1152 1374 1442 1782 2247 2751 3400 754 6 1223 1460 1526 1886 2380 2912 3600 798 991 1296 1546 1611 1991 2512 3074 3800 842 1046 1368 1632 1696 2096 2644 3236 4000 886 1101 1440 1718 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. 475 253 570 304 665 355 760 405 855 456 950 507 1045 557 1140 608 1235 659 1330 710 1520 811 1710 912 1900 1014 2090 1115 2280 1216 2470 1318 2660 1419 2850 1520 exponent n 1.27 1.26 1.19 1.24 1.23 1.15 512 285 614 341 716 398 818 455 921 512 1023 569 1125 625 1228 682 1330 739 1432 796 1637 910 1841 1023 2046 1137 2251 1251 All Narbonne convectors available on request. 6

Narbonne - height 142 mm convectors An example of the convector NARBONNE 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE 22 142 1600 47 name height length L length [mm] parameters t z / t p / t i 22 23 34 35 46 58 321 399 525 599 500 165 205 276 310 385 478 630 718 600 198 246 331 371 449 558 735 838 700 231 287 386 434 513 638 840 958 800 264 328 441 496 577 717 945 1077 900 297 369 496 557 641 797 1050 1197 1000 330 410 552 619 705 877 1155 1317 1100 363 451 607 681 769 956 1260 1436 1200 396 492 662 743 833 1036 1365 1556 1300 429 533 717 805 897 1116 1470 1676 1400 462 574 772 867 1026 1275 1680 1915 1600 528 656 883 991 1154 1435 1890 2155 1800 594 739 9 1115 1282 1594 2100 2394 2000 660 821 1103 1239 1410 1753 2310 2633 2200 726 902 1214 1362 1538 1913 2520 2873 2400 792 985 1324 1486 1667 2072 2730 3112 2600 858 1067 1434 1610 1795 2232 2940 3352 2800 924 1149 1545 1734 1923 2391 3150 3591 3000 990 1231 1655 1858 2051 2550 3360 3830 3200 1056 1313 1765 1982 2179 2710 3570 4070 3400 1122 1395 1876 2106 2308 2869 3780 4309 3600 1188 1477 1986 2229 2436 3029 3990 4549 3800 1254 1559 2096 2354 2564 3188 4200 4788 4000 1320 1641 2207 2477 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.30 1.30 1.26 1.29 1.30 1.25 All Narbonne convectors available on request. 727 374 872 449 1018 524 1163 599 1309 674 1454 748 1599 823 1745 898 1890 973 2036 1048 2326 1197 2617 1347 2908 1497 3199 1647 3490 1796 3780 1946 4071 2096 4362 2245 830 438 995 525 1161 613 1327 701 14 788 1659 876 1825 964 1991 1051 2157 1139 2323 1227 2654 1401 2986 1577 3318 1752 3650 1927 7

convectors Narbonne - height 214 mm An example of the convector NARBONNE 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE 22 214 1600 47 name height length L length [mm] parameters t z / t p / t i 11 22 23 34 35 46 58 232 419 518 697 826 500 118 211 261 353 414 278 503 621 836 991 600 142 254 313 424 497 325 587 725 976 1156 700 166 296 366 495 580 371 670 828 1115 1321 800 189 338 418 565 663 418 754 2 1255 1486 900 213 380 470 636 746 464 838 1035 1394 1651 1000 236 423 522 707 828 510 922 1139 1533 1816 1100 260 465 574 777 911 557 1006 1242 1673 1981 1200 284 507 626 848 994 603 1089 1346 1812 2146 1300 307 549 679 919 1077 650 1173 1449 1952 2311 1400 331 592 731 990 1160 742 1341 1656 2230 2642 1600 378 676 835 1130 1326 835 1508 1863 2509 2972 1800 425 761 940 1272 1491 928 1676 2070 2788 3302 2000 473 845 1044 1413 1657 1021 1844 2277 3067 3632 2200 520 0 1148 1555 1822 1114 2011 2484 3346 3962 2400 568 1014 1253 1696 1988 1206 2179 2691 3624 42 2600 614 1099 1357 1837 2154 1299 2346 2898 3903 4623 2800 662 1183 1462 1979 2320 1392 2514 3105 4182 4953 3000 709 1268 1566 2120 2485 1485 2682 3312 4461 5283 3200 757 1353 1670 2261 2651 1578 2849 3519 4740 5613 3400 804 1437 1775 2403 2816 1670 3017 3726 5018 5944 3600 851 1522 1879 2544 2983 1763 3184 33 5297 6274 3800 898 1606 1984 2685 3148 1856 3352 4140 5576 6604 4000 946 1691 2088 2827 3314 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. 1036 517 1243 621 1450 724 1658 828 1865 1 2072 1034 2279 1138 2486 1241 2694 1345 2901 1448 3315 1655 3730 1862 4144 2069 4558 2275 4973 2483 5387 2689 5802 2896 6216 3103 exponent n 1.32 1.34 1.34 1.33 1.35 1.36 1.35 1296 650 1555 780 1814 910 2074 1041 2333 1171 2592 1301 2851 1431 3110 1561 3370 1691 3629 1821 4147 2081 4666 2341 5184 2601 5702 2861 All Narbonne convectors available on request. 8

Narbonne - height 286 mm convectors An example of the convector NARBONNE 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE 22 286 1600 47 name height length L length [mm] parameters t z / t p / t i 11 22 23 34 35 46 58 289 516 631 862 986 500 146 255 312 426 482 346 619 757 1034 1183 600 175 306 374 511 579 404 722 883 1206 1380 700 204 357 436 596 675 462 826 1009 1378 1577 800 233 408 499 681 771 519 929 1135 1551 1774 900 262 459 561 766 868 577 1032 1261 1723 1971 1000 291 510 623 851 964 635 1135 1387 1895 2168 1100 320 561 685 6 1060 692 1238 1513 2068 2365 1200 349 612 748 1022 1157 750 1342 1639 2240 2562 1300 378 663 810 1107 1253 808 1445 1765 2412 2759 1400 408 714 872 1192 1349 923 1651 2018 2757 3154 1600 466 816 997 1362 1543 1039 1858 2270 3101 3548 1800 524 918 1122 1532 1735 1154 2064 2522 3446 3942 2000 582 1020 1246 1703 1928 1269 2270 2774 3791 4336 2200 640 1122 1371 1873 2121 1385 2477 3026 4135 4730 2400 699 1224 1495 2043 2314 1500 2683 3279 4480 5125 2600 757 1326 1620 2214 2507 1616 2890 3531 4824 5519 2800 815 1428 1745 2384 2699 1731 3096 3783 5169 5913 3000 873 1530 1869 2554 2892 1846 3302 4035 5514 6307 3200 1 1632 1994 2725 3085 1962 3509 4287 5858 6701 3400 990 1734 2118 2895 3278 2077 3715 4540 6203 7096 3600 1048 1836 2243 3065 3471 21 3922 4792 6547 7490 3800 1106 18 2368 3235 3663 2308 4128 5044 6892 7884 4000 1164 2040 2492 3406 3856 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.34 1.38 1.38 1.38 1.40 1.40 1.39 All Narbonne convectors available on request. 1224 599 1468 718 1713 838 1958 958 2202 1077 2447 1197 2692 1317 26 1436 3181 1556 3426 1676 3915 1915 4405 2155 4894 2394 5383 2633 5873 2873 6362 3112 6852 3351 7341 3591 1511 743 1813 891 2115 1040 2418 1189 2720 1337 3022 1486 3324 1634 3626 1783 3929 12 4231 2080 4835 2377 5440 2674 6044 2971 6648 3268 9

convectors Narbonne VT Convectors Narbonne VT are composed of several interconnected profiled steel heating elements of a rectangular cross section. Each convector has got two bottom connecting openings, each with external thread G ¾, enabling bottom connection. Three side openings with internal thread G ½ are normally designed for mounting the Danfoss thermostatic valve insert with pre-regulation, plus the air vent and closing plug. Narbonne VT convectors are equipped with two side covers and the top masking grille. The heating profiles are mounted horizontally, so that to retain the 2 mm-wide distancing between each two, necessary to compensate for the heat expansion of the elements, and enabling the perfect varnish cover of the entire convector s surface. Most models are equipped with convective elements, increasing the heating efficiency of the convectors. technical specification Material : high quality steel profiles of a rectangular cross section, dimensions: 70 x 11 x 1.5 mm (high pressure version: 70 x 11 x 2.0 mm) Metal sheet thickness : heating profiles 1.50 mm; convectors 0.50 mm Height : 142, 214, 286 mm Length : from 500 up to 4000 mm Depth : from 68 up to 339 mm Connections : 2 x G ¾, bottom connectors, 3 x G ½, side connectors Max. operating pressure : 5 bar for the standard version, 8 bar for the high pressure version Max. temperature : 110 C Colour : RAL 9016, other RAL colours available, surcharge at each order Brackets : wall or floor ordered separately, at Client s preference Accessories : plug and air vent, Danfoss thermostatic valve insert included in the convector s kit 10

Narbonne VT convectors front view side view H = 286 L NA 11 NA 22 NA 23 214 142 5 50 25 26 47 104 68 150 H - height [mm] L - length [mm] NA 34 NA 35 NA 46 175 47 232 104 129 257 top view NA 11 26 NA 34 68 NA 22 47 NA 35 104 232 47 175 NA 23 104 150 NA 46 129 257 Note: the diagrams show the right-hand side versions of the convectors. weight and water volume weight : kg/m height [mm] 142 214 286 11-11.1 14.5 22 14.0 20.6 27.2 23 17.0 24.8 32.7 34 23.9 35.2 46.4 35 27.0 39.4 51.9 46 33.9 49.8 65.6 water volume : l/m height [mm] 142 214 286 11-1.7 2.2 22 2.2 3.3 4.4 23 2.2 3.3 4.4 34 3.3 5.0 6.7 35 3.3 5.0 6.7 46 4.5 6.8 9.1 11

convectors Narbonne VT N Proper initial preset can be easily and precisely obtained with no necessity of using any dedicated tools (see the diagrams below). X A B 50 25 GE 3 / 4 " detail X setting ring N 1234 Danfoss valve insert no. 013G0360 marker 567 After the valve s masking cover has been removed (pos. A), a built-in valve insert (not included in the convector s set) will be mounted (pos. B): Danfoss (RA 2994, RAW 5115), Oventrop Uni XD, Heimeier VK, Herz D, Honeywell thera-da. Tips for setting: remove the plastic valve s masking cover; rotate the setting ring to achieve the required setting (1, 2,...7, N) opposite the marker; the preset can be adjusted in the range between 1 and 7, with the resolution of 0.5 of the scale. The factory default preset values cor r espond to the highest kv value, which in turn corresponds to the N setting. Note: adjustment of preset values between the scale s elements, in the crossed-out area, is not allowed! 12

Narbonne VT - height 142 mm convectors An example of the convector NARBONNE VT 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE VT 22 142 1600 47 name height length L length [mm] parameters t z / t p / t i 22 23 34 35 46 321 399 525 500 165 205 276 385 478 630 600 198 246 331 449 558 735 700 231 287 386 513 638 840 800 264 328 441 577 717 945 900 297 369 496 641 797 1050 1000 330 410 552 705 877 1155 1100 363 451 607 769 956 1260 1200 396 492 662 833 1036 1365 1300 429 533 717 897 1116 1470 1400 462 574 772 1026 1275 1680 1600 528 656 883 1154 1435 1890 1800 594 739 9 1282 1594 2100 2000 660 821 1103 1410 1753 2310 2200 726 902 1214 1538 1913 2520 2400 792 985 1324 1667 2072 2730 2600 858 1067 1434 1795 2232 2940 2800 924 1149 1545 1923 2391 3150 3000 990 1231 1655 2051 2550 3360 3200 1056 1313 1765 2179 2710 3570 3400 1122 1395 1876 2308 2869 3780 3600 1188 1477 1986 2436 3029 3990 3800 1254 1559 2096 2564 3188 4200 4000 1320 1641 2207 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.30 1.30 1.26 1.29 1.30 All Narbonne convectors available on request. 599 310 718 371 838 434 958 496 1077 557 1197 619 1317 681 1436 743 1556 805 1676 867 1915 991 2155 1115 2394 1239 2633 1362 2873 1486 3112 1610 3352 1734 3591 1858 3830 1982 4070 2106 4309 2229 4549 2354 4788 2477 727 374 872 449 1018 524 1163 599 1309 674 1454 748 1599 823 1745 898 1890 973 2036 1048 2326 1197 2617 1347 2908 1497 3199 1647 3490 1796 3780 1946 4071 2096 4362 2245 13

convectors Narbonne VT - height 214 mm An example of the convector NARBONNE VT 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE VT 22 214 1600 47 name height length L length [mm] parameters t z / t p / t i 11 22 23 34 35 46 232 419 518 697 500 118 211 261 353 278 503 621 836 600 142 254 313 424 325 587 725 976 700 166 296 366 495 371 670 828 1115 800 189 338 418 565 418 754 2 1255 900 213 380 470 636 464 838 1035 1394 1000 236 423 522 707 510 922 1139 1533 1100 260 465 574 777 557 1006 1242 1673 1200 284 507 626 848 603 1089 1346 1812 1300 307 549 679 919 650 1173 1449 1952 1400 331 592 731 990 742 1341 1656 2230 1600 378 676 835 1130 835 1508 1863 2509 1800 425 761 940 1272 928 1676 2070 2788 2000 473 845 1044 1413 1021 1844 2277 3067 2200 520 0 1148 1555 1114 2011 2484 3346 2400 568 1014 1253 1696 1206 2179 2691 3624 2600 614 1099 1357 1837 1299 2346 2898 3903 2800 662 1183 1462 1979 1392 2514 3105 4182 3000 709 1268 1566 2120 1485 2682 3312 4461 3200 757 1353 1670 2261 1578 2849 3519 4740 3400 804 1437 1775 2403 1670 3017 3726 5018 3600 851 1522 1879 2544 1763 3184 33 5297 3800 898 1606 1984 2685 1856 3352 4140 5576 4000 946 1691 2088 2827 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. 826 414 991 497 1156 580 1321 663 1486 746 1651 828 1816 911 1981 994 2146 1077 2311 1160 2642 1326 2972 1491 3302 1657 3632 1822 3962 1988 42 2154 4623 2320 4953 2485 5283 2651 5613 2816 5944 2983 6274 3148 6604 3314 exponent n 1.32 1.34 1.34 1.33 1.35 1.36 1036 517 1243 621 1450 724 1658 828 1865 1 2072 1034 2279 1138 2486 1241 2694 1345 2901 1448 3315 1655 3730 1862 4144 2069 4558 2275 4973 2483 5387 2689 5802 2896 6216 3103 All Narbonne convectors available on request. 14

Narbonne VT - height 286 mm convectors An example of the convector NARBONNE VT 22 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE VT 22 286 1600 47 name height length L length [mm] parameters t z / t p / t i 11 22 23 34 35 46 289 516 631 862 500 146 255 312 426 346 619 757 1034 600 175 306 374 511 404 722 883 1206 700 204 357 436 596 462 826 1009 1378 800 233 408 499 681 519 929 1135 1551 900 262 459 561 766 577 1032 1261 1723 1000 291 510 623 851 635 1135 1387 1895 1100 320 561 685 6 692 1238 1513 2068 1200 349 612 748 1022 750 1342 1639 2240 1300 378 663 810 1107 808 1445 1765 2412 1400 408 714 872 1192 923 1651 2018 2757 1600 466 816 997 1362 1039 1858 2270 3101 1800 524 918 1122 1532 1154 2064 2522 3446 2000 582 1020 1246 1703 1269 2270 2774 3791 2200 640 1122 1371 1873 1385 2477 3026 4135 2400 699 1224 1495 2043 1500 2683 3279 4480 2600 757 1326 1620 2214 1616 2890 3531 4824 2800 815 1428 1745 2384 1731 3096 3783 5169 3000 873 1530 1869 2554 1846 3302 4035 5514 3200 1 1632 1994 2725 1962 3509 4287 5858 3400 990 1734 2118 2895 2077 3715 4540 6203 3600 1048 1836 2243 3065 21 3922 4792 6547 3800 1106 18 2368 3235 2308 4128 5044 6892 4000 1164 2040 2492 3406 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.34 1.38 1.38 1.38 1.40 1.40 All Narbonne convectors available on request. 986 482 1183 579 1380 675 1577 771 1774 868 1971 964 2168 1060 2365 1157 2562 1253 2759 1349 3154 1543 3548 1735 3942 1928 4336 2121 4730 2314 5125 2507 5519 2699 5913 2892 6307 3085 6701 3278 7096 3471 7490 3663 7884 3856 1224 599 1468 718 1713 838 1958 958 2202 1077 2447 1197 2692 1317 26 1436 3181 1556 3426 1676 3915 1915 4405 2155 4894 2394 5383 2633 5873 2873 6362 3112 6852 3351 7341 3591 15

convectors Narbonne V Convectors Narbonne V are composed of several interconnected profiled steel heating elements of a rectangular cross section. Each convector has got four connecting openings, each with internal thread G ½, enabling side connection, both from the leftand the right-hand side. Narbonne convectors are equipped with two side covers, but no top masking grille. The heating profiles are mounted vertically, so that to retain the 2 mm-wide distancing between each two, necessary to compensate for the heat expansion of the elements, and enabling the perfect varnish cover of the entire convector s surface. Most models are equipped with convective elements, increasing the heating efficiency of the convectors. technical specification Material : high quality steel profiles of a rectangular cross section, dimensions: 70 x 11 x 1.5 mm (high pressure version: 70 x 11 x 2.0 mm) Metal sheet thickness : heating profiles 1.50 mm; convectors 0.50 mm Height : 1600, 1800, 2000, 2200 mm Width : from 142 up to 862 mm Depth : od 68 do mm Connections : 4 x G ½, side connectors Max. operating pressure : 5 bar for the standard version, 8 bar for the high pressure version Max. temperature : 110 C Colour : RAL 9016, other RAL colours available, surcharge at each order Accessories : plug and air vent, included in the convector s kit 16

Narbonne V convectors front view side view L NV 10 NV 11 NV 20 NV 21 H - 50 H 26 26 47 47 H - height [mm] L - length [mm] 68 68 top view NV 10 26 NV 11 26 NV 20 47 NV 21 68 68 47 weight and water volume weight : kg/m height [mm] 1600 1800 2000 2200 10 44.5 49.6 54.8 59.7 11 63.4 68.5 73.7 78.8 20 85.4 95.5 105.5 115.5 21 104.4 114.4 124.4 134.4 water volume : l/m height [mm] 1600 1800 2000 2200 10 11.4 12.5 13.9 15.2 11 11.4 12.5 13.9 15.2 20 22.7 24.3 27.7 30.5 21 22.7 24.3 27.7 30.5 17

convectors Narbonne V - height 1600 and 1800 mm An example of the convector Narbonne V 21 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE V 21 1600 430 47 name height length L length [mm] parameters t z / t p / t i height 1600 mm height 1800 mm 10 11 20 21 10 11 20 21 142 (2) 247 121 281 140 416 202 452 221 281 137 314 156 469 229 509 249 214 (3) 372 182 424 211 627 305 681 333 424 207 473 235 706 345 768 376 286 (4) 497 243 566 281 839 408 911 446 566 277 632 314 944 462 1026 502 358 (5) 622 304 708 352 1050 511 1140 558 708 346 791 3 1182 578 1285 629 430 (6) 747 365 851 423 1261 614 1369 670 851 416 950 472 1419 694 1543 755 502 (7) 872 427 9 4 1472 716 1598 782 9 486 1109 551 1657 810 1801 881 574 (8) 998 488 1136 564 1683 819 1828 894 1136 556 1268 630 1895 927 2060 1008 646 (9) 1123 549 1278 635 1894 922 2057 1006 1278 625 1427 709 2132 1043 2318 1134 718 (10) 1248 610 1421 706 2105 1024 2286 1118 1421 695 1586 788 2370 1159 2576 1260 790 (11) 1373 672 1563 776 2316 1127 2515 1230 1563 764 1745 867 2608 1276 2835 1387 862 (12) 1498 733 1706 847 2527 1230 2745 1343 1706 834 1904 946 2845 1392 30 1513 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.40 1.37 1.41 1.40 1.40 1.37 1.40 1.40 All Narbonne convectors available on request. 18

Narbonne V - height 2000 and 2200 mm convectors An example of the convector Narbonne V 21 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE V 21 2000 430 47 name height length L length [mm] parameters t z / t p / t i height 2000 mm height 2200 mm 10 11 20 21 10 11 20 21 142 (2) 317 156 348 174 521 256 570 282 354 175 384 194 575 284 633 316 214 (3) 478 235 524 262 786 386 859 424 534 264 578 292 866 428 953 476 286 (4) 638 314 701 350 1050 516 1147 567 714 353 772 389 1157 572 1274 636 358 (5) 799 3 877 438 1315 646 1436 710 8 441 967 488 1448 716 1595 796 430 (6) 960 472 1054 526 1579 776 1725 852 1073 530 1161 586 1740 860 1916 956 502 (7) 1120 551 1230 614 1843 906 2014 995 1252 619 1356 684 2031 1004 2236 1116 574 (8) 1281 630 1406 702 2108 1036 2303 1138 1432 708 1550 782 2322 1147 2557 1276 646 (9) 1442 709 1583 790 2372 1166 2592 1281 1612 797 1745 880 2614 1292 2878 1437 718 (10) 1603 788 1759 878 2636 1296 2881 1424 1791 885 19 978 2905 1435 3199 1597 790 (11) 1763 867 16 966 2901 1426 3169 1566 1971 974 2134 1076 3196 1579 3519 1757 862 (12) 1924 946 2112 1054 3165 1556 3458 1709 2151 1063 2328 1174 3488 1724 3840 1917 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.39 1.36 1.39 1.38 1.38 1.34 1.38 1.36 All Narbonne convectors available on request. 19

convectors Narbonne V VT Convectors Narbonne V VT are composed of several interconnected profiled steel heating elements of a rectangular cross section. Each convector has got two bottom connecting openings, each with external thread G ¾, enabling bottom connection. Four side openings with internal thread G ½ are normally designed for mounting the Danfoss thermostatic valve insert with pre-regulation, plus the air vent and closing plugs. Narbonne V VT convectors are equipped with two side covers, but no top masking grille. The heating profiles are mounted vertically, so that to retain the 2 mm-wide distancing between each two, necessary to compensate for the heat expansion of the elements, and enabling the perfect varnish cover of the entire convector s surface. Most models are equipped with convective elements, increasing the heating efficiency of the convectors. technical specification Material : high quality steel profiles of a rectangular cross section, dimensions: 70 x 11 x 1.5 mm (high pressure version: 70 x 11 x 2.0 mm) Metal sheet thickness : heating profiles 1.50 mm; convectors 0.50 mm Height : 1600, 1800, 2000 mm Width : from 214 up to 862 mm Depth : from 68 up to mm Connections : 2 x G ¾, bottom connectors, 4 x G ½, side connectors Max. operating pressure : 5 bar for the standard version, 8 bar for the high pressure version Max. temperature : 110 C Colour : RAL 9016, other RAL colours available, surcharge at each order Accessories : plug and air vent, Danfoss thermostatic valve insert included in the convector s kit 20

Narbonne V VT convectors front view side view L NV 10 NV 11 NV 20 NV 21 H 50 55 68 26 26 47 47 68 H - height [mm] L - length [mm] top view NV 10 26 NV 11 26 NV 20 68 47 NV 21 68 47 Note: the diagrams show the right-hand side versions of the convectors. weight and water volume weight : kg/m height [mm] 1600 1800 2000 10 44.5 49.6 54.8 11 63.4 68.5 73.7 20 85.4 95.5 105.5 21 104.4 114.4 124.4 water volume : l/m height [mm] 1600 1800 2000 10 11.4 12.5 13.9 11 11.4 12.5 13.9 20 22.7 24.3 27.7 21 22.7 24.3 27.7 21

convectors Narbonne V VT N Proper initial preset can be easily and precisely obtained with no necessity of using any dedicated tools (see the diagrams below). detail X setting ring N 1234 marker 567 Danfoss valve insert no. 013G0360 50 55 X A G 3 / 4 " B Note!!!: Narbonne V VT connection (supply and return) is opposite to Narbonne VT! After the valve s masking cover has been removed (pos. A), a built-in valve insert (not included in the convector s set) will be mounted (pos. B): Danfoss (RA 2994, RAW 5115), Oventrop Uni XD, Heimeier VK, Herz D, Honeywell thera-da. Tips for setting: remove the plastic valve s masking cover; rotate the setting ring to achieve the required setting (1, 2,...7, N) opposite the marker; the preset can be adjusted in the range between 1 and 7, with the resolution of 0.5 of the scale. The factory default preset values cor r espond to the highest kv value, which in turn corresponds to the N setting. Note: adjustment of preset values between the scale s elements, in the crossed-out area, is not allowed! 22

Narbonne V VT - height 1600 mm convectors An example of the convector NARBONNE V VT 21 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE V VT 21 1600 430 47 name height length L length [mm] parameters t z / t p / t i height 1600 mm 10 11 20 21 214 (3) 372 182 424 211 627 305 681 333 286 (4) 497 243 566 281 839 408 911 446 358 (5) 622 304 708 352 1050 511 1140 558 430 (6) 747 365 851 423 1261 614 1369 670 502 (7) 872 427 9 4 1472 716 1598 782 574 (8) 998 488 1136 564 1683 819 1828 894 646 (9) 1123 549 1278 635 1894 922 2057 1006 718 (10) 1248 610 1421 706 2105 1024 2286 1118 790 (11) 1373 672 1563 776 2316 1127 2515 1230 862 (12) 1498 733 1706 847 2527 1230 2745 1343 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.40 1.37 1.41 1.40 All Narbonne convectors available on request. 23

convectors Narbonne V VT - height 1800 mm An example of the convector NARBONNE V VT 21 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE V VT 21 1800 430 47 name height length L length [mm] parameters t z / t p / t i height 1800 mm 10 11 20 21 214 (3) 424 207 473 235 706 345 768 376 286 (4) 566 277 632 314 944 462 1026 502 358 (5) 708 346 791 3 1182 578 1285 629 430 (6) 851 416 950 472 1419 694 1543 755 502 (7) 9 486 1109 551 1657 810 1801 881 574 (8) 1136 556 1268 630 1895 927 2060 1008 646 (9) 1278 625 1427 709 2132 1043 2318 1134 718 (10) 1421 695 1586 788 2370 1159 2576 1260 790 (11) 1563 764 1745 867 2608 1276 2835 1387 862 (12) 1706 834 1904 946 2845 1392 30 1513 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.40 1.37 1.40 1.40 All Narbonne convectors available on request. 24

Narbonne V VT - height 2000 mm convectors An example of the convector NARBONNE V VT 21 RADIATOR DESCRIPTION - AN EXAMPLE : NARBONNE V VT 21 2000 430 47 name height length L length [mm] parameters t z / t p / t i height 2000 mm 10 11 20 21 214 (3) 478 235 524 262 786 386 859 424 286 (4) 638 314 701 350 1050 516 1147 567 358 (5) 799 3 877 438 1315 646 1436 710 430 (6) 960 472 1054 526 1579 776 1725 852 502 (7) 1120 551 1230 614 1843 906 2014 995 574 (8) 1281 630 1406 702 2108 1036 2303 1138 646 (9) 1442 709 1583 790 2372 1166 2592 1281 718 (10) 1603 788 1759 878 2636 1296 2881 1424 790 (11) 1763 867 16 966 2901 1426 3169 1566 862 (12) 1924 946 2112 1054 3165 1556 3458 1709 Convectors heat output [W] in accordance with PN-EN 442 standard for parameters 75/65/20 C and 55/45/20 C. exponent n 1.39 1.36 1.39 1.38 All Narbonne convectors available on request. 25

additional info Mounting distances for Narbonne WK 10-13 wall brackets: positioning for Narbonne convectors 150 X 150 Note: When using more than two wall brackets, additional brackets should be evenly placed within the X segment WK 10 brackets WK 11-M brackets NA 11 NA 22 NA 23 NA 34 WK 12 brackets WK 13 brackets SK 10-18 stands: positioning for Narbonne convectors 1 / 2 length 1 / 2 length 150 150 Note: For length values exceeding 2200 mm, it is necessary to apply the additional third SK stand! 105-175 SK 10 / SK 11 SK 12 / SK 13 SK 14 / SK 15 SK 16 / SK 17 SK 18 NA 34 NA 35 NA 46 NA 58 166,5 89 175 166,5 146 232 245 132 257 327 173 339 X X X X 115 50 68 115 25 197 50 150 197 25 175 NA 35 NA 46 NA 58 279 50 232 279 25 257 361 25 339 NA 11 NA 22 NA 23 65 33 68 88,5 46 88,5 103 150 X X X X dimension: the required distance from the wall, or glass surface, as measured from the rear wall of the convector 26

Mounting distances for Narbonne VT additional info WK 10-12 wall brackets: positioning for Narbonne VT convectors 150 X 150 Note: When using more than two wall brackets, additional brackets should be evenly placed within the X segment. WK 10 brackets NA 11 NA 22 WK 11-M brackets WK 12 brackets NA 23 NA 34 NA 35 NA 46 SK 10-17 stands: positioning for Narbonne VT convectors 1 / 2 length 1 / 2 length 150 150 Note: For length values exceeding 2200 mm, it is necessary to apply the additional third SK stand! 105-175 197 50 150 197 25 175 279 50 232 279 25 257 115 50 68 115 25 SK 10 / SK 11 SK 12 / SK 13 NA 11 NA 22 NA 23 65 33 68 88,5 46 88,5 103 150 X X X SK 14 / SK 15 SK 16 / SK 17 NA 34 NA 35 NA 46 166,5 89 175 X 166,5 146 232 X 245 132 X 257 dimension x: the required distance from the wall, or glass surface, as measured from the rear wall of the convector 27

additional info Mounting distances for Narbonne V rear view 71 71 71 71 107 107 90 90 90 90 90 1600, 1800, 2000, 2200 1600, 1800, 2000, 2200 1600, 1800, 2000, 2200 1600, 1800, 2000, 2200 1600, 1800, 2000, 2200 40 40 40 40 40 130 130 130 130 130 142 214 286 358 szer. 430-862 top view NV 10 NV 11 NV KS 20 20 KS NV 21 21 60 60 48 14 60 14 60 14 Wall distancing: WA 10 and WA 11 wall brackets for Narbonne V convectors W bracket convector s W dimension [mm] WA 10 NV 10/11* 35 WA 10 NV 20/21 79.5 WA 11 NV 10/11* 45 WA 11 NV 20/21 89.5 *Tip: when mounting NV 10 and NV 11 convectors with angle connection, it is necessary to apply the adequate wall plugs, optionally the wall brackets, in order to achieve the required wall distancing. 28

Mounting distances for Narbonne V VT additional info rear view 71 71 71 71 107 107 90 90 90 90 1600, 1800, 2000 1600, 1800, 2000 1600, 1800, 2000 1600, 1800, 2000 40 40 40 40 130 130 130 130 214 286 358 szer. 430-862 top view NV 10 NV 11 NV 20 NV 21 60 60 48 14 14 60 60 14 Note: the diagrams show the right-hand side versions of the convectors. Wall distancing: WA 10 and WA 11 wall brackets W bracket convector s W dimension [mm] WA 10 NV 10/11* 35 WA 10 NV 20/21 79.5 WA 11 NV 10/11* 45 WA 11 NV 20/21 89.5 * Tip: when mounting NV 10 and NV 11 convectors with angle connection, it is necessary to apply the adequate wall plugs, optionally the wall brackets, in order to achieve the required wall distancing. 29

additional info Conversion table heating agent temperature [ C] example: conversion coefficient for the convector s heat output selection at temperatures other than t i air temperature in the heated room [ C] t z t p 5 8 12 16 18 20 22 24 95 90 0.48 0.50 0.54 0.57 0.59 0.61 0.64 0.66 85 0.50 0.52 0.56 0.60 0.62 0.64 0.67 0.70 80 0.52 0.55 0.59 0.63 0.65 0.68 0.70 0.73 75 0.54 0.57 0.61 0.66 0.69 0.72 0.75 0.78 70 0.57 0.60 0.65 0.70 0.73 0.76 0.79 0.83 90 85 0.52 0.55 0.58 0.63 0.65 0.67 0.70 0.73 80 0.54 0.57 0.61 0.66 0.68 0.71 0.74 0.77 75 0.57 0.60 0.64 0.69 0.72 0.75 0.78 0.82 70 0.59 0.63 0.67 0.73 0.76 0.80 0.83 0.87 65 0.62 0.66 0.71 0.77 0.81 0.85 0.89 0. 85 80 0.56 0.59 0.64 0.69 0.72 0.75 0.78 0.81 75 0.59 0.62 0.67 0.72 0.75 0.79 0.82 0.86 70 0.62 0.65 0.70 0.77 0.80 0.84 0.88 0.92 65 0.65 0.69 0.75 0.81 0.85 0.89 0.94 0.99 60 0.68 0.73 0.79 0.87 0.91 0.96 1.01 1.07 80 75 0.61 0.65 0.70 0.76 0.79 0.83 0.87 0.91 70 0.64 0.68 0.74 0.81 0.84 0.88 0. 0.97 65 0.68 0.72 0.78 0.86 0.90 0.94 0.99 1.05 60 0.72 0.76 0.83 0.91 0.96 1.01 1.07 1.13 55 0.76 0.81 0.89 0.98 1.04 1.10 1.16 1.24 75 70 0.67 0.72 0.78 0.85 0.89 0.94 0.98 1.04 65 0.71 0.75 0.82 0.90 0.95 1.00 1.05 1.12 60 0.75 0.80 0.88 0.97 1.02 1.08 1.14 1.21 55 0.80 0.85 0.94 1.04 1.10 1.17 1.24 1.32 50 0.85 0.91 1.01 1.13 1.20 1.28 1.37 1.47 70 65 0.75 0.79 0.87 0.96 1.01 1.07 1.13 1.19 60 0.79 0.84 0. 1.03 1.08 1.15 1.22 1.30 55 0.84 0.90 0.99 1.11 1.17 1.25 1.33 1.42 50 0.89 0.96 1.07 1.20 1.28 1.37 1.47 1.58 65 60 0.83 0.89 0.98 1.10 1.16 1.23 1.31 1.40 55 0.88 0.95 1.05 1.18 1.26 1.34 1.43 1.54 50 0.94 1.02 1.14 1.29 1.37 1.47 1.59 1.71 60 55 0.94 1.01 1.13 1.27 1.36 1.45 1.56 1.68 50 1.00 1.08 1.22 1.39 1.48 1.60 1.73 1.87 45 1.08 1.17 1.33 1.53 1.65 1.78 1.94 2.13 55 50 1.07 1.16 1.31 1.50 1.62 1.75 1.90 2.07 45 1.15 1.26 1.43 1.66 1.80 1.96 2.15 2.37 40 1.25 1.37 1.59 1.86 2.03 2.24 2.48 2.78 50 45 1.23 1.36 1.56 1.82 1.98 2.17 2.40 2.67 40 1.34 1.48 1.73 2.05 2.25 2.50 2.79 3.15 35 1.47 1.65 1.94 2.36 2.63 2.96 3.38 3.92 45 40 1.45 1.62 1.90 2.28 2.53 2.83 3.19 3.66 35 1.60 1.80 2.15 2.64 2.96 3.37 3.89 4.58 40 35 1.75 1.98 2.40 3.00 3.41 3. 4.62 5.54 30 1.96 2.25 2.79 3.61 4.21 5.01 6.14 7.87 The calculated room heat demand is 800 W. For the supply water the designed temperature is 55 C, and for the return water it is 45 C. The designed air temperature in the room is 20 C. For the values of parameters 55/45/20 C, the correction factor value of 1.96 is red off. The table has been prepared for n = 1.3 As a result of multiplying heat demand (800 W) by the correction factor (1.96), the value of heat output (800 W) by the correction factor (1.96), the value of heat output is found (1568 W). This value is used for selection of the radiator for the values of parameters 75/65/20 C. 30

Hydraulic characteristics for Narbonne VT and Narbonne V VT additional info Pressure loss diagram for the convectors Narbonne VT and Narbonne V VT with Danfoss valve inserts Initial preset value Base: supply temperature 70 C return temperature 55 C room temperature 20 C 10 3 9 8 7 6 5 4 initial preset 1 k v = 0.13 for the convectors up to approx. 500 W initial preset 2 k v = 0.21 for the convectors up to approx. 800 W initial preset 3 k v = 0.26 for the convectors up to approx. 1000 W initial preset 4 k v = 0.31 for the convectors up to approx. 1200 W water flow [l/h] 3 2 10 2 9 8 7 6 5 4 initial preset N - kv=0,75 7 - kv=0,63 6 - kv=0,52 5 - kv=0,41 4 - kv=0,31 3 - kv=0,26 2 - kv=0,21 1 - kv=0,13 initial preset 5 k v = 0.41 for the convectors up to approx. 1600 W 3 initial preset 6 k v = 0.52 for the convectors up to approx. 2000 W 2 initial preset 7 k v = 0.63 for the convectors up to approx. 2400 W initial preset N k v = 0.75 for the convectors from 2400 W 10 10 2 4 9 10 2 3 5 6 7 8 pressure loss [mbar] 2 3 4 5 1 mbar = 100 Pa = 0,1 kpa Pressure loss [mbar] double-pipe system with proportional band 2K. Corrections of the valve initial presets can also be entered in operating conditions (under working pressure). 31

additional info Order codes When ordering the NARBONNE or NARBONNE VT radiator please use the following scheme describing its, height, length, variant of execution, packing method, connection and colour. The WK wall mounting brackets or the SK floor stands for the NARBONNE and NARBONNE VT radiators must be ordered separately using the appropriate tables on the following pages and the order codes detailed in the chapter ACCESSORIES. Radiator variant II: Radiator : F83 Narbonne F86 Narbonne VT Radiator variant I: 1 with top grille and side panels Standard version working pressure 5 bar 1 without hanging lugs High-pressure version working pressure 8 bar B without hanging lugs Colour code I: 0 standard RAL 9016 1 galvanized + RAL 9016 R RAL A galvanized + RAL Colour code II: Optional when selecting R or A code in the Colour code I field Example R + 3000 = RAL3000 F83 22 021 100 1 1 3 0 0 3000 Type: Height: Length: Packing code: Connection code: 11* 22 23 34 35 46 58* 007** 70 mm 014 142 mm 021 214 mm 028 286 mm 050 500 mm step every 100 mm 140 1400 mm 160 1600 mm step every 200 mm 400 4000 mm 3 Purmo * except for the Narbonne and Narbonne VT radiators of height 70 mm and 142 mm ** except for the Narbonne VT radiator An example of order for the NARBONNE radiator: - : 22 - height: 142 mm - length: 1000 mm - connection: right hand side connection - colour: RAL 9016 For Narbonne 0 right hand side connection (CD) 1 left hand side connection (AB) E flow-through connection: supply on the top left side (AD) F flow-through connection: supply on the top right side (CB) W bottom connection: supply on the right side - return on the left side (DB) V bottom connection: supply on the left side - return on the right side (BD) For Narbonne VT 0 right hand side bottom connection (VR) Danfoss insert 1 left hand side bottom connection (VL) Danfoss insert Narbonne an example of order code - F832201410011300 An example of order for the NARBONNE VT radiator: - : 22 - height: 286 mm - length: 1000 mm - right hand side bottom connection - colour: RAL 9016 Narbonne VT an example of order code - F862202810011300 32

Order codes additional info When ordering the NARBONNE V or NARBONNE V VT radiator please use the following scheme describing its, height, length, variant of execution, packing method, connection and colour. The WA 10 or WA 11 wall mounting brackets for the NARBONNE V and NARBONNE V VT radiators must be ordered separately using the appropriate order codes detailed in the chapter ACCESSORIES. Radiator variant II: Radiator : F85 Narbonne V F87 Narbonne V VT Radiator variant I: 1 with side panels without top grille Standard version working pressure 5 bar 0 with hanging lugs High-pressure version working pressure 8 bar A with hanging lugs Colour code I: 0 standard RAL 9016 1 galvanized + RAL 9016 R RAL A galvanized + RAL Colour code II: Optional when selecting R or A code in the Colour code I field Example R + 3000 = RAL3000 F85 11 160 036 1 0 3 0 0 3000 Type: Height: Length: Packing code: Connection code: 10 11 20 21 160 1600 mm 180 1800 mm 200 2000 mm 220* 2200 mm * except for the Narbonne V VT radiator 014* 142 mm 021 214 mm 028 286 mm 036 358 mm 043 430 mm 050 502 mm 057 574 mm 065 646 mm 072 718 mm 079 790 mm 086 862 mm 3 Purmo For Narbonne V 0 right hand side connection (CD) 1 left hand side connection (AB) E flow-through connection: supply on the top left side (AD) F flow-through connection: supply on the top right side (CB) W bottom connection: supply on the right side - return on the left side (DB) V bottom connection: supply on the left side - return on the right side (BD) An example of order for the NARBONNE V radiator: - : 11 - height: 160 mm - length: 358 mm - connection: right hand side connection - colour: RAL 9016 For Narbonne V VT 0 right hand side bottom connection (VR) Danfoss insert 1 left hand side bottom connection (VL) Danfoss insert Narbonne V Narbonne V VT an example of order code - F851116003610300 An example of order for the NARBONNE V VT radiator: - : 11 - height: 160 mm - length: 358 mm - connection: right hand side connection - colour: RAL 9016 VL L R VR an example of order code - F871116003610300 33

additional info Selection tables for stands SK stands and quantity selection table for the Narbonne convectors, of the height up to 286 mm (inclusive) convector s NA 11 NA 22 stand / convector s length [mm] up to 2000 from 2200 up to 2000 from 2200 SK 10 for the finished floor 2 3 SK 11 for the unfinished floor 2 3 SK 12 for the finished floor 2 3 SK 13 for the unfinished floor 2 3 convector s NA 23 NA 34 NA 35 stand / convector s length [mm] up to 2000 from 2200 up to 2000 from 2200 up to 2000 from 2200 SK 12 for the finished floor 2 3 SK 13 for the unfinished floor 2 3 SK 14 for the finished floor 2 3 2 3 SK 15 for the unfinished floor 2 3 2 3 convector s NA 46 NA 58 stand / convector s length [mm] up to 2000 from 2200 up to 2000 from 2200 SK 16 for the finished floor 2 3 SK 17 for the unfinished floor 2 3 SK 18 for the finished floor 2 3 1 / 2 length 1 / 2 length 150 150 105-175 Note: For length values exceeding 2200 mm, it is necessary to apply the additional third SK stand! 34

Selection tables for wall brackets additional info WK wall brackets and quantity selection table for the Narbonne convectors, of the height up to 286 mm (inclusive) convector s NA 11 NA 22 NA 23 NA 34 NA 35 wall bracket WK 10 WK 10 WK 11-M WK 11-M WK 12 height [mm] length [mm] 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 70 2 3 2 3 2 3 2 3 142 2 3 2 3 2 3 2 3 214 2 3 2 3 2 3 2 3 2 3 286 2 3 2 3 2 3 2 3 convector s NA 35 NA 35 NA 46 NA 46 NA 46 wall bracket WK 12 WK 12 WK 12 WK 12 WK 12 height [mm] length [mm] 500 up to 1800 2000 up to 2600 2800 up to 3600 3800 up to 4000 500 up to 2000 2200 up to 3000 500 up to 1800 2000 up to 2800 3000 500 up to 1400 70 2 3 142 2 3 214 2 3 4 286 2 3 4 5 5 2 convector s NA 46 NA 58 NA 58 NA 58 NA 58 wall bracket WK 12 WK 13 WK 13 WK 13 WK 13 height [mm] length [mm] 1600 up to 2200 2400 up to 2800 500 up to 2000 2200 500 up to 1600 1800 up to 2200 500 up to 1100 1200 up to 1600 1800 up to 2200 500 up to 800 70 2 3 142 2 3 214 2 3 4 286 3 4 2 convector s NA 58 NA 58 wall bracket WK 13 WK 13 height [mm] length [mm] 900 up to 1300 1400 up to 1600 1800 up to 2000 2200 70 142 214 286 3 4 5 6 150 X 150 Note: When using more than two wall brackets, additional brackets should be evenly placed within the X segment 35

additional info Selection tables for stands SK stands and quantity selection table for the Narbonne VT convectors, of the height up to 286 mm (inclusive) convector s NA 11 NA 22 NA 23 stand / convector s length [mm] up to 2000 from 2200 SK 10 for the finished floor 2 3 SK 11 for the unfinished floor 2 3 up to 2000 from 2200 up to 2000 from 2200 SK 12 for the finished floor 2 3 2 3 SK 13 for the unfinished floor 2 3 2 3 convector s NA 34 NA 35 NA 46 stand / convector s length [mm] up to 2000 from 2200 up to 2000 from 2200 SK 14 for the finished floor 2 3 2 3 SK 15 for the unfinished floor 2 3 2 3 up to 2000 from 2200 SK 16 for the finished floor 2 3 SK 17 for the unfinished floor 2 3 1 / 2 length 1 / 2 length 150 150 105-175 Note: For length values exceeding 2200 mm, it is necessary to apply the additional third SK stand! 36

Selection tables for wall brackets additional info WK wall brackets and quantity selection table for the Narbonne VT convectors, of the height up to 286 mm (inclusive) convector s NA 11 NA 22 NA 23 NA 34 wall bracket WK 10 WK 10 WK 11-M WK 10 length [mm] 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 500 up to 2000 2200 up to 4000 142 2 3 2 3 2 3 height [mm] 214 2 3 2 3 2 3 2 3 286 2 3 2 3 2 3 2 3 convector s NA 35 NA 35 NA 35 NA 46 wall bracket WK 10 WK 10 WK 11-M WK 12 length [mm] 500 up to 2000 2200 up to 4000 500 up to 1800 2000 up to 2600 2800 up to 3600 3800 up to 4000 500 up to 2000 2200 up to 3000 142 2 3 2 3 height [mm] 214 2 3 286 2 3 4 5 convector s NA 46 NA 46 NA 46 wall bracket WK 12 WK 12 WK 12 length [mm] 500 up to 1800 2000 up to 2800 3000 500 up to 1400 1600 up to 2200 2400 up to 2800 142 height [mm] 214 2 3 4 286 5 2 3 4 150 X 150 Note: When using more than two wall brackets, additional brackets should be evenly placed within the X segment. 37

additional info Accessories description SK 10 stand (for the finished floor): Narbonne convector s 11 Narbonne VT convector s 11 includes: - bottom foot (80 mm) - 1 pc., - upper foot (175 mm) with sound-insulated convector contact area- 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 11 stand (for the unfinished floor): Narbonne convector s 11 Narbonne VT convector s 11 includes: - bottom foot (175 mm) - 1 pc., - upper foot (200 mm) with sound-insulated convector contact area- 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 12 stand (for the finished floor): Narbonne convector s 22, 23 Narbonne VT convector s 22, 23 includes: - bottom foot (80 mm) - 1 pc., - upper foot (175 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 13 stand (for the unfinished floor): Narbonne convector s 22, 23 Narbonne VT convector s 22, 23 includes: - bottom foot (175 mm) - 1 pc., - upper foot (200 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 14 stand (for the finished floor): Narbonne convector s 34, 35 Narbonne VT convector s 34, 35 includes: - bottom foot (80 mm) - 1 pc., - upper foot (175 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). order code AZ1BS000F1001000 AZ1BS000R1101000 AZ1BS000F1201000 AZ1BS000R1301000 AZ1BS000F1401000 38

Accessories additional info description SK 15 stand (for the unfinished floor): Narbonne convector s 34, 35 Narbonne VT convector s 34, 35 includes: - bottom foot (175 mm) - 1 pc., - upper foot (200 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 16 stand (for the finished floor): Narbonne : 46 Narbonne VT : 46 includes: - bottom foot (80 mm) - 1 pc., - upper foot (175 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 17 stand (for the unfinished floor): Narbonne : 46 Narbonne VT : 46 includes: - bottom foot (175 mm) - 1 pc., - upper foot (200 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). SK 18 stand (for the finished floor): Narbonne : 58 includes: - bottom foot (80 mm) - 1 pc., - upper foot (175 mm) with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). order code AZ1BS000R1501000 AZ1BS000F1601000 AZ1BS000R1701000 AZ1BS000F1801000 stand cover: SK 10, SK 12, SK 14, SK 16, SK 18 AZ1MS000C1001000 39

additional info Accessories description WK 10 brackets: Narbonne convector s 11, 22 Narbonne VT convector s 11, 22 includes: - wall bracket - 1 pc., - detachable fixing bracket with sound-insulated convector contact are - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). WK 11-M brackets: Narbonne convector s 23, 34 Narbonne VT convector s 23, 34 includes: - wall bracket - 1 pc., - detachable fixing bracket with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). WK 12 brackets: Narbonne convector s 35, 46 Narbonne VT convector s 35, 46 includes: - wall bracket - 1 pc., - detachable fixing bracket with sound-insulated convector contact are - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). WK 13 brackets: Narbonne convector s 58 includes: - wall bracket - 1 pc., - detachable fixing bracket with sound-insulated convector contact area - 1 pc., - grip protecting against accidental removal - 1 pc. Designed only for the convectors of up to 286 mm of height (inclusive). order code AZ1BW00011001000 AZ1BW000111010A0 AZ1BW00011201000 AZ1BW00011301000 wall bracket cover: WK 10, WK 11-M, WK 12, WK 13 AZ1MW00010001000 40

Accessories additional info wall bracket WA 10: description Narbonne V convector s 10, 11, 20, 21 (for the widths 142 mm and 214 mm) Narbonne V VT convector s 10, 11, 20, 21 (for the widths 142 mm and 214 mm) includes: - wall bracket - 1 pc., - distancing grip - 1 pc., - screw - 1 pc., wall plug - 1 pc., - overall sound-insulated wall bracket WA 11: Narbonne V convector s 10, 11, 20, 21 (for the width from 286 mm inclusive) Narbonne V VT convector s 10, 11, 20, 21 (for the width from 286 mm inclusive) includes: - wall bracket - 2 pc., - distancing grip - 2 pc., - screws and wall plugs, - overall sound-insulated order code AZ1BU00010001000 AZ1BU00011002000 Narbonne and Narbonne VT convectors s 11 and 22, of heights from 358 mm up to 790 mm, are available at request, and only in versions with dedicated wall brackets. Other Narbonne and Narbonne VT s are not available in heights exceeding 286 mm. 41