Achieving the impossible



Similar documents
Using the Phoenix MultiPlus

Phoenix MultiPlus. Multi-functional inverter / battery charger with intelligent shore and generator power management

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

Stroom voor elke toepassing

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Connecting your Victron product to a computer with VE Configure

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

ENERGY. ANYTIME. ANYWHERE. MARINE

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

Manual. Solar Fountain Mobile Phone Charger

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Inverter / Charger Installation General Operations and AC and DC Connections

Your own power station: For continuous power

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

OFF-GRID BACK-UP & ISLAND SYSTEMS

User Manual of Grid Tie Inverter with Limiter

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Photovoltaic Solar Energy Unit EESFB

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

TruPower-Portable-500W. Solar Starter kit

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Current Monitoring Kit QUICK START GUIDE

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Current Monitoring Kit

Additional Solar System Information and Resources

Automatic start of a generator

User s Manual Before using the inverter, you need to read and save the safety instructions.

User Manual HomeGrid 3000 Solar Generator

Online UPS. PowerWalker VFI 1000R/1U

Combi B Alarm box. Mounting instructions

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

RO 340 ECO. The challenge of obtaining maximum energy efficiency has been overcome with the following: Maximum efficiency of each of its components:

Caravan & Leisure Power Packages

DC Electronic Loads 8500 series

Thyristor-controlled power supplies and battery chargers

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

How To Use A Power Supply Unit (Upu)

BB800 Off-Grid Solar System

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

PowerGem Pro Uninterruptible Power Supply

Connection method for charging systems a key element for electric vehicles

User Manual 1K/2K/3K Online UPS

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

Automatic management of two different energy sources

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Instruction manual. Electrobloc EBL 100-2

Diesel Generating Set

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

vacon ac drives for mining & minerals

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Energy meters For an efficient control of energy consumption

AC-115 Compact Networked Single Door Controller. Installation and User Manual

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

FIREDEX Conventional Fire Panels

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Solar Power for PC Deployments: Enabling ICT Beyond the Grid

CUTES Solar Power System

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

NGSS Data Consolidator (DC)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User s Manual AURORA 1.2K/2.2K

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

10000HXL31/15000HXL31/20000HXL31

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

USER MANUAL Online UPS 1K/2K/3K

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

LIFT CONTROL SYSTEMS CATALOGUE 2007

1.44 kw Programmable DC Power Supplies XLN Series

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

Instruction Manual for Operating Panel 301 and 302

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

How To Make A Fronius Cl Power Inverter

How to read this guide

Manual. VE.Bus to NMEA 2000 interface

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Electrical System From The Top Down By Rick Denney, GMC Eastern States April 2006

Solar Panel Experiment

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

TORKEL 820 Battery Load Unit

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Power Proportional Distribution (PPD)

How SafePlug Smart Receptacles Can Save Money in Commercial Buildings

Electrical Shore Connections / Cold Ironing

... Electronic Softstarter...

MULTIFUNCTION TIME RELAY CRM-93H

Smart DeviceNet Remote I/O Terminals

LIFT CONTROL SYSTEMS CATALOGUE 2007

SPL 2-00/-01 OPERATION INSTRUCTIONS

ACRELab Renewable Energy System Test and Support Laboratory

USER MANUAL Online UPS 1K/2K/3K Rack

Transcription:

1 Achieving the impossible Taking control of shore power with the Phoenix Multi/MultiPlus from Victron Energy * Sometimes the features of a new product are so unique that the benefits are difficult to understand or simply denied. The Phoenix MultiPlus is such a product. The purpose of this paper is to step by step clarify the many features of the Phoenix Multi/MultiPlus. Think of a situation were electricity from the grid or a generator is not available or limited in power. Think of boats, mobile homes, trucks, service vans, remote communication systems or off-grid houses. All too often shore power in the marina or on the camping ground is limited. All too often small gensets are a headache because of premature failure or frequent maintenance. The Phoenix Multi/MultiPlus solves these problems. 1. The block diagram of the Phoenix Multi and MultiPlus (M/M+) The most important components and features: 1.1. The bidirectional converter The M/M+ is built around a bidirectional converter, that operates as an inverter or as a battery charger. The converter of the M+ does more than a conventional bidirectional converter: it operates in parallel with the grid, with shore power or with a genset. It can add power to AC supply (with energy from the battery) and it will use surplus power to recharge. In most cases the M+ will also reduce the harmonic distortion of the genset voltage (this can be important for certain sensitive loads such as an induction cooker) * Victron Energy N.V. / De Paal 35 / 1351 JG Almere Haven / (+31) - (0)36-535 97 00 www.victronenergy.com

2 1.2. A multifunctional relay This relay can a. o. be programmed to start a generator based on power demand and / or battery voltage. 1.3. A RS485 port All parameters of the M/M+ are programmable. The most important parameters can be programmed with a push button code, but it is much more convenient to use the MK.1 RS485 to RS232 converter, VEConfigure software (downloadable from our website) and a PC Notebook computer. Examples of programmable parameters: - inverter DC voltage cut out - charge curve - maximum charge current - parallel operation and 3 phase operation - programming the multifunctional relay 1.4. Connector for parallel operation and 3 phase operation Up to 6 Multi s can be parallel-connected to increase power to 15 kw. In 3 phase configuration up to 18 Multi s can be used to build a 45 kw inverter / charger! 1.5. AC input with 16 Amp thermal breaker and safety relay The maximum AC input current of the M/M+ is 16 A. The safety relay makes sure that no dangerous AC voltage will be present on for example the shore power plug when disconnected. 1.6. The Multi Control Panel (16 A or 30 A) The rotary knob on this panel is crucial: with this knob the maximum AC input current can be set, to a maximum of 16 A or 32 A. 1.7. AC output To connect the AC appliances. 1.8. The drawbacks of a conventional combined inverter / charger A conventional combi will operate as an inverter when there is no AC input voltage present, and as a battery charger when AC is available. That s it. When AC is available the input current will be the current drawn by the battery charger plus the current taken by the connected AC appliances. A powerfull battery charger draws a lot of current: a 24 V 70 A charger for example will take nearly 10 A from the AC supply. When connected to a 16 A socket only 6 A will be left for the remaining AC equipment on board. The result is that a powerfull combi will trip a 16 A circuit breaker as soon as some household equipment is switched on (a high output battery charger will have the same effect) 1.9. PowerControl: how the Phoenix Multi solves the problem described in par. 1.8. The Phoenix Multi measures the AC input current and gives priority to the connected AC equipment. The PowerControl function makes sure that only whatever current is left over is used to charge the batteries. This will be explained below with several examples.

3 1.10. PowerAssist: this function, unique to the MultiPlus, takes PowerControl to a further dimension, allowing the MultiPlus to supplement the capacity of the AC source. This is where we achieved the impossible : the bidirectional converter of the MultiPlus operates in parallel with the AC input and will add current (with energy from the battery) whenever demand exceeds the capacity of the supply! More power needed than the AC supply permits? The MultiPlus will supply the difference with power taken from the battery. Has the load been reduced? The MultiPlus will use any surplus power to recharge the battery. 2. How it works in practice Below are several examples to clarify the benefit of PowerControl (available on both the Multi and the MultiPlus) and of PowerAssist (MultiPlus only). For the first examples we assume an AC supply limited to max. 4 A. To make it work the input current limit should be set at 4 A on the Multi Control Panel. Example 2.1 In this example all AC loads are off. With the Multi Control Panel set at 4 A the converter will not take more than 4 A, which limits the battery charge current to about 60 A. Example 2.2 Now some small loads are switched on and the load increases to 2 A. Only 4 2 = 2 A is left to charge the batteries and the charge current is reduced to about. 30 A. Shore current is automatically limited to 4 A and the circuit breaker will not trip!

4 Example 2.3 The coffee machine is switched on and current consumption increases to 4 A. Nothing is left to charge the batteries: the charge current is automatically reduced to 0. And again: the shore current circuit breaker does not trip! Example 2.4 And now the impossible happens: the water heater switches on and the current increases to 10 A. This is where PowerAssist (available on the MultiPlus only) is needed. The bidirectional converter starts operating as inverter to add 6 A to the 4 A that is available from the shore-side: total 6 + 4 = 10 A, and no overload on the AC supply! As soon as the load reduces to less than 4 A any current that is left over will be used to recharge the battery. Example 2.5 In this example a 16 A supply is assumed. On the Multi Control Panel the current limit can now be set at 16 A. The logic remains the same: with 16 A available and 10 A load, 6 10 = 6 A is left over, which results in a maximum charge current of 90 A.

5 3. More power needed: parallel operation With a washing machine on board (and possibly also a dishwasher, electric cooker, oven and airconditioning) the current needed will increase to much more than 16 A. What to do? One solution is a stronger AC power supply. But more than 16 A shore power is not always easy to find, and berths for mega yachts are expensive! Why not installing a set of parallel Multi s as shown in the examples below? Example 3.1 In this example 3 Multi s 24/3000/70 are operating in parallel. The AC supply is rated at 16 A and therefore the Multi Control Panel is also set at 16 A. When power demand is low (during the night for ex.) the batteries will be charged. With 6 A needed for different loads, 16 6 = 10 A is left over. Therefore the batteries will be charged at max. 70 A. This is much less than the maximum charge current of 3 x 70 = 210 A the 3 Multi s are capable of, but then the shore side circuit breaker would trip immediately! Example 3.2 Turning on the washing maschine (current 13 A) will, during a short period, increase the load to 6 + 13 = 19 A. PowerAssist is now needed to supply the missing 3 A. This is made possible by installing 1 MultiPlus (as Master) and 2 Multi s (as Slave). The complete set of 3 units will then have PowerAssist functionality. And again: the load is 19 A but the supply is only 16!

6 Example 3.3 The power needed will increase dramatically as soon as more household equipment is switched on, or when the electric cooker is in use. The AC current will peak to 40 A ore more. Now the Multi s must supply an additional 40 16 = 24 A to the AC source and the batteries will be discharged at a rate of some 230 A. It may be hard to believe but the total discharge of the batteries, measured in Ampere-hours (Ah), will nevertheless be limited. This is because a cooker or washing machine does need a lot of power during only a short period. Practice has shown that 16 A shore current is, on average, more than sufficient for big yachts and or luxury mobile homes. It is only when continous power requirement increases (due for ex. to airconditioning) that a more powerful supply will be needed. Please refer to our book Electricity on Board for detailed battery capacity calculations. 4. A DC genset on board When no AC supply is available (no shore current, because the yacht is sailing) the Multi s will operate as inverters and the DC genset will charge the batteries. Example 4.1: maximum power required 7 kw, average load 700 W If a lot of power is required for a short period only, a WhisperGen or a small Fischer Panda DC generator will easely supply the average load. Please refer to our book Electricity on Board for more examples

7 Example 4.2: maximum power required 7 kw, average load 2 kw Intensive use of airconditioning will raise power consumption beyond the capacity of the WhisperGen. A powerful DC generator will be needed to keep running hours and noise within acceptable limits. The multifunctional relay of the Multi can be used to automatically start the generator in case of high power demand. In addition our BMV-501 battery monitor may be used to start the generator once the batteries have been discharged to a preset percentage. Complete wiring diagrams can be found on our website www.victronenergy.com. A remark about 3 phase electric motors to drive pumps, a diving compressor or airconditioning: Three phase motors of up to 3 kw can be connected to a single phase supply by adding a 3 phase motor drive with single phase input. The motor drive then takes care of 3 phase to 1 phase conversion and will also reduce start-up current. Example 4.3: An alternative solution, using inverters and battery chargers The maximum AC supply current can also be controlled when only battery chargers are connected to it. All AC equipment should then be supplied by the inverters and the batteries are again used to absorb periods of high power demand. Using battery chargers with universal 90 to 265 V input capability will make sure that a yacht can connect to any shore power supply anywhere in the world.

8 5. How it works with an AC generator PowerAssist can also be used to boost the output of an AC genset. Next to reducing size and weight of the genset this also has the following advantages: - In most cases the harmonic distortion of the genset output will be reduced (this can be important for certain sensitive loads such as an induction cooker) - Because the generator can be reduced in size the load in % of its rated power will increase. This will improve efficiency and increase service life. Example 5.1: maximum power required 2.5 kw A lot can be achieved with a simple and compact system. As long as either the shore supply is available or the generator is running, the system can supply up to 26 A of AC current, which amounts to 6 kw. (the shore or genset supplies up to 16 A, to which the Phoenix MultiPlus will add up to 10 A) And the batteries will be recharged as soon the load reduces to less 16 A. Important building blocks of the system: a) PowerMan 230/16-0 An automatic 16 A transfer switch. b) Battery Monitor BMV 501 The BMV 501 keeps track of the state of charge of the battery. The BMV 501 can be programmed to generate a generator start signal when the batteries have been discharged to a preset percentage. Together with the start signal from the Multi the generator will start both in case of a high power requirement and when the batteries have been discharged to a preset percentage.

9 Example 5.2a and 5.2b: maximum power required 5 kw A much more robust system is obtained by installing 2 Multi s. The 2 Multi s (of which 1 unit should be a MultiPlus to have PowerAssist functionality) can supply sufficient power even when several AC loads are switched on simultaneously. And once the generator is running the system will supply up to 16 + 2 x 10 = 36 A. Moreover the 2 Multi s will easely absorb all available power from the generator when recharging the batteries, reducing running hours of the genset to the bare mininmum. Please note that a small 3000 rpm genset has limited service life and is in general not made to run at full load for long periods of time. (reduce output to 70 % of full load with the Multi Control Panel!). A 1500 rpm model is the better choice if intensive use is expected

10 Example 5.3: maximum power required 7 kw, and average power 2 kw (intensive use of airconditioning) It is now time to install a bigger genset, unless a substantial generator free period is not required. In this example transfer switch model PowerMan 230/40-2 has been used. This transfer switch will accept up to 40 A of AC input current. The genset current limit can be set inside the cubicle (indicated in red in the schematic diagram above) and is independent from the shore current setting on the PowerMan Control Panel (indicated in green in the schematic diagram above). The PowerMan Control Panel is similar but not identical to the Multi Control Panel. Up to 3 Multi s can be connected directly to the PowerManager.

11 Example 5.4: maximum power required 12 kw, and average power 4 kw (intensive use of airconditioning) By connecting to 2 shore outlets of 16 A each, up to 32 A (7 kw) of shore current is available. The trick is to connect the AC system to one outlet, and a 100 A battery charger to the other. The transfer switch is a PowerMan 230/80-2, suitable for up to 80 A input. Up to 6 Phoenix Multi s can be connected to this Power Manager. 3 phase systems Phoenix Multi s and Phoenix inverters can also be configured for 3 phase operation. We will be pleased to make a proposal for a 3 phase system.