AVIATION WARNING LIGHT WITH LED PRODUCT CODE : OPT-01



Similar documents
AVIATION WARNING LIGHT WITH LED PRODUCT CODE: OPT-04

Fire Pump Controllers Remote Alarm Panels

ISO 9001 : 2000 certified Copyright 2008 All rights are reserved

Floodlight Range Installation Guide

Cisco Unified IP Phone Power Injector

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

HERZ-Thermal Actuators

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

DALI RC BASIC SO. Control unit Operating instructions

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Water Leak Detection System

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION


SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

INDICATOR LAMPS & LED REPLACEMENT LAMPS

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

DuroSite TM High Bay Lighting

Electronic, Digital and Mechanical Vibration Switches

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Emergency lighting units EM powerled

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Product Specification instalert Rapid Messenger Variable Message Sign

SPID Azimuth Antenna rotator Type: BIG-RAK/HR

OBSTRUCTION LIGHT OL 150-LED 230V

COLOR VIDEO DOOR PHONE CDV-71BE/D

LED Anti-Collision Lighting System for Airbus A320 Family

Industrial infrared heater IR For premises with large volumes and high ceilings

D/N VARI-FOCAL IR CAMERA

Cross-beam scanning system to detect slim objects. 100 mm in

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

Superlight Compact Nano

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Business/ Home GSM Alarm System

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

WD-AMX Water Detection Controllers

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Multifunction devices

2013 Wireless Video Intercom INSTALLATION GUIDE

Installation and Operation Guide for PD5100 Automatic Transfer Switch

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

LC/LCD ranges level controllers

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

E-STOP relays, safety gate monitors

Home Security Alarm System

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Know-how makes the difference. Electrical Actuators

Evolve LED Area Light

RY2 miniature industrial relays

Dehumidifier D 850E. - Instruction manual version 02

Electric Rotary Actuator - On/Off or programmable control actuator

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Uninterruptible Power Supply

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

OLI. Oil level indicator

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Operating Instructions

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

MCR1900 Media Converter 19-Slot Chassis

GTEC transfer switch open transition

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Product and functional description

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Evolve LED Area Light

TS93 EMR T/PT/TDE. Surface applied door closer

MAJORSINE Power Inverter

Airfield Lighting Product Description F2.1 F22. Low Intensity Obstruction Light

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Medical Lighting. XL4 Patient Light

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Product Guide Specification

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Transcription:

AVIATION WARNING LIGHT WITH LED PRODUCT CODE : OPT-01 OPT-01 User Manual Page 1

Table of Contents GENERAL SPECIFICATIONS....... 3 1- Supply Voltage... 3 2- Lamp Type... 3 3- Backup System... 3 4- Simultaneous System.... 3 5- Failure Warnings System.... 4 6- Blink System.... 4 7- Continuous System.... 4 8- Operating Temprature... 4 9- Operationg Frequency... 4 10- Cable Specifications... 4 11- Certifacetes... 4 12- Mechanical Specifications... 5 13- Connection Diagram.. 6 TECHINICAL SPECIFICATIONS... 7 PRODUCING FIRM...... 8 Page 2

GENERAL SPECIFICATIONS OPTİMA Warning Lights, are designed and manufactured to warn aircrafts / helicopters for high altitude places. It is designed to use on high towers, monopole masts, high buildings, flagpoles and all warning related areas. OPT-01 System consists of one unit double lamp armature. System operates under the control of photocell relay so automatically turns the system on when ambience gets dark and turns it off when the ambience gets lighten. Upon request in ordering process, system options below are available. 1- Supply Voltage: 12V AC/DC - 24V AC/DC - 48VAC/DC - 110V AC/DC - 220V AC 2- Lamp Type : OPTİMA Led Lamp Optima Led Lamp : OPTİMA Lamps are specially designed and manufactured by OPTİMA ELEKTRONİK. Due to lamps completely made by leds, they have very long working lifes. (100.000 hours). OPTİMA Aviation Warning Lights has 5 years warranty. 3- Backup Systems : System has two lamps on two seperate arms. While one of the lamps is working the other lamp waits as a spare.(figure-1) If active lamp fails, it sends a failure code to the spare one and turn the spare one on after 3 seconds. Figure-1 4- Simultaneous System : Two lamps on two arms works simultaneously.(figure-2) If one of the lamps fails it does not effect the other lamp. Figure-2 Page 3

5- Failure Warning System : With this option, user is able to control the operation of system from a distant place. User installs the system by connecting failure outputs (COM: common NO: normally open NC: normally close) to sounded or lighted warning device. In case of any failure, lamps send warning to failure warning unit inside the control box. By means of Failure Warning System, problem is solved in a short time. 6- Blink System : Lamps blinks 60 times in a minute. 7- Continuous System : On this option system works continuously without blinking. 8- Operating Temprature : -55 C / +55 C 9- Operationg Frequency : 50 Hz 10- Cable Specifications : a- System with Error Alert : 4x1.5mm2 b- System without Error Alert : 2x1.5mm2 *NYY and LIYCY cable types are recommended, the cable types are determined due to customer choice. *Cable lengths must be calculated due to tower length and distance between power supply and control center. 11- Certifacetes: CE Certifacete FUNCTIONALITY TEST OF THE SYSTEM: First tests should be conducted before the system mount on the tower. Test steps; 1-Check the physical conditions of the system. Be sure that system is not damaged. 2-Read the user manual in the package completely. Page 4

12- Mechanical Specifications : ARMATURE: 1-Armature Body : Aluminium Moulding 2-Armature Cover : Aluminium 3-Body Paint : Ral-7032 Elektrostatic Polyester 4-Bolts-Nuts-Washers : Coated 5-Lamp Protective Cover : Red Polycarbonate 6-Protection Class : IP-65 7-Dimensions : 365mmx500mmx110mm (Figure-3) 8-Weight : 2.8 kg Figure-3 Page 5

13- Connection Diagram Figure-4 Figure-5 Figure-6 Page 6

TECHNICAL SPECIFICATIONS OPTİMA AVIATION WARNING LIGHT TECHNICAL PROPERTIES TEKNİK ÖZELLİKLER: LED Number Total Candela Visibility Distance Visibility Angle Energy Spending Operating Time LED Test Alarm Output Maintanence LED Life 140 units Ultra Bright Led 810.000 mcd 10 km in dark and clear environment conditions (Annex14 standard) X Plane=360 (horizontal) Y Plane= 45 (vertical) (Annex14 standard) 6~7 Watt/hour Operates according to the lighting level, does not considers temporary lightning. For double armature; 2nd light operates when the 1st one breaks down Exists (Uninterrupted test at night, Once in 10 minutes at daytime) With dry contact output. Normally Open or Normally Closed No need to maintanence 100.000 hours (operating duration) Operating Temprature -55 C +55 C Light Store Bottom Body Operating Voltage IP Standard Mode of operation Body Paint Bolts-Nuts-Washers Weight Dimensions Fastening Bracket Polycarbonate (red)- Resistant to warming. İcing and ignition Aluminium Casting 12V AC/DC, 24V AC/DC, 48V AC/DC,110V AC, 220V-AC IP65 Lamps blinks 60 times in a minute Ral-7032 Elektrostatik Polyester Coated 2.8 Kg Figure-3 865 Gr Page 7

PRODUCING FIRM As a result of R&D studies, OPTİMA aviation warning light led lamp has been developed by OPTİMA ELECTRONIC COMPANY in 2006. OPTİMA ELEKTRİK ELEKTRONİK VE TELEKOMÜNİKASYON SANAYİ TİCARET LİMİTED ŞİRKETİ OPTİMA ELECTRIC ELECTRONIC AND TELECOMMUNICATION INDUSTRY COMMERCE LIMITED CORPORATION Dudullu Organize Sanayi Bölgesi 3. Cad. Saraçoğlu İş Merkezi No:5/37-38 ÜMRANIYE / İSTANBUL / TURKEY PHONE: +90 216 364 09 20 FAX: +90 216 364 09 21 E-MAIL: info@optimaelektronik.com.tr WEB: www.optimaelektronik.com.tr Custom Designs Special designs can be made in line with customer demand. Please contact with OPTİMA. Page 8