The Intelligent AX1 Switchgear for Medium Voltage



Similar documents
Safe and secure distribution of medium voltage with AX1

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Advantages of Fixed Circuit Breaker Switchgear

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

FAQs-Main switchboard design criteria

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

The following components are common to most cubicles; this example is an ABB HK cubicle.

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

UFES Active protection for switchgear

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

P System Cubicles. Certified for more safety

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Secondary Unit Substations

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

What will MV switchgear look like in the future? by Jean-Marc Biasse

Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications

Switchgear and Metal-Enclosed Bus

Session Four: Internal Arc Safety in New and Existing Switchgear

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Welcome IEEE Members and Guests Jan 20, 2014

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Remote Monitoring and REC 501 Control Unit Product Guide

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

Engineering Specification

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

SIVACON The Versatile Low-Voltage Switchboard

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Gas-insulated switchgear type series 8DN8. up to 170 kv, 63 ka, 4000 A. Answers for energy.

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Comparative study for cables and busbars

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Medium Voltage Switchgear

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Arc Terminator Active Arc-Resistant Switchgear

Metal Clad Indoor Instrument Transformer for Plug-In Systems

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

IEC & 2 standard. The reference for safe and reliable LV switchboards

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

30 ms High Speed Transfer System (HSTS) Product Description

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

Nothing s BetterThan the Original MODAN Power Distribution Systems

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Addendum #2 Contract UK-11-13

Disconnectors and Earthing Switches 36 kv up to 800 kv

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

How To Choose A Transformer

Sample - No Commercial Use

Choosing for tranquility

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Enhancing Personnel Safety with Arc Resistant Equipment

Primary and Secondary Electrical Distribution Systems

How To Make A Power Supply From A Power Generator

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear. Internal Arc Proof

know-how Giant in distributing electricity for industry Prisma GK

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

CAS 36 Ring Main Unit

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Power-Zone 4 Arc Resistant Low Voltage Switchgear

8146/5 Series Breaker Panelboards

Medium voltage indoor circuit breakers ANSI/IEC solutions

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

Respecting the environment

SIVACON Low Voltage Switchboard

Low Voltage Switchgear

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Power Plant Electrical Distribution Systems

MNS is Switchgear System Technical Overview

Transcription:

The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched medium voltage switchgear AX1 represents a new and functional approach to the switchgear architecture, consistently utilising new technology without the limitations given by the old type components. Besides the incorporation of software intelligence, it also results in many general advantages, such as compactness, easy installation and high personnel safety and service reliability. AX1 may even house a trolley with the battery system for the auxiliary supply. The protection relays and operating push-buttons are replaced by bay computers handling all protection, operation and the interlocking between the apparatus in the switchgear. The modern control system needs less wiring. The basic philosophy for the switchgear architecture is to keep all high voltage parts in one separate compartment, and all mechanical and auxiliary parts fully accessible outside the high voltage compartment. Parts needing access, like auxiliaries and circuit breaker actuators are in this concept fully and safely accessible, also when the high voltage parts are alive and the circuit breaker is closed. The switchgear is supplied with a specially developed and extremely fast Arc Eliminator. The concept is designed for fast and simple installation on site. The cubicles have sliding doors, safely keeping the operating area free for the operating personnel, and limiting the needed space. 1. A new switchgear architecture for modern technology 1.1 Philosophy The standard IEC 60298 for AC metal-enclosed switchgear and controlgear, 1 52 kv, defines three different types of architectures: Metal-clad, compartmented and cubicle switchgear and controlgear. With the new switchgear AX1 a completely new architecture is introduced, not defined by the standard. The definitions of metal clad and compartmented switchgear switchgear with different compartments for at least the circuit breaker, the bus-bar and the cable connection is based on the old technology with old type of high voltage components, needing regular access for maintenance. The basic function of the separate compartments is to protect personnel from accidental access to live parts when doing different maintenance work on other parts of the main circuit. A second function, not foreseen by the IEC standard but often supposed to be fulfilled, is the limitation of the failure and the damage in case of a severe failure under conditions of arcing due to an internal fault. The verification of this limitation is in fact not defined by the test according to the standard. Both those functions are however solved in a completely different way by the AX1 switchgear. 1

1.2 Secluded high voltage compartment for the main circuit The basic idea with the new switchgear architecture is to install all parts of the main circuit in a separate compartment with limited access to personnel. Modern high voltage components normally need no maintenance and no easy access, except possibly for the actuators. The main circuit compartment of AX1 actually forms a strong encapsulation of its own. Access to this encapsulation is only possible through a bolted wall, being a part of the circuit breaker frame. The advantage of no regular door of the high voltage compartment is an extremely safe protection to personnel in front of the switchgear. This means protection both against accidental access to the high voltage parts and against the result of an internal arc. The test to prove the safety in the case of an internal arc is not valid for the case of an open door. The main circuit compartment is common for all cubicles in the section of the switchgear. This layout has several advantages: Simple installation, improved cooling, a better dielectric and more compact solution. It also means a lower internal pressure in case of an internal arc. Any damage by an arc is effectively avoided by the Arc Eliminator, see below. 1.3 Actuator compartment makes the breakers accessible Experience from both SF6 and vacuum circuit breakers shows, that the only part of the breaker that might need access for maintenance is the mechanical actuator. All actuators are easily accessible inside the separate actuator compartments of AX1. In a metal-clad switchgear access to any part of the circuit breaker is impossible without withdrawal of the whole circuit-breaker from the circuit breaker compartment. This means that the circuit has to be opened, as well as the enclosure for the high voltage part of the switchgear. The separate actuator compartment makes it possible to maintain and even replace the whole actuator without opening the circuit breaker, which is safely locked in its position during this operation. All auxiliaries for the breakers and disconnectors are completely outside the main circuit compartment. SF6 circuit breaker poles are also accessible from the actuator compartment for refilling of gas, even with the circuit breaker in service. With modern equipment this is normally not needed, but the possibility is favourable in the few cases. A suitable name for this circuit breaker arrangement is Accessible Circuit Breaker, since the whole breaker is always accessible for the most relevant cases of maintenance. The poles inside the main circuit compartment are connected with plug-in contacts to the bus-bars and are possible to exchange after de-energising of the bus-bars. This is however a very rare case of maintenance. Actuator for disconnector/earthing switch Actuator for circuit-breaker 1.4 Standardised control compartments The control compartment is located on the top of the actuator compartment. AX1 is controlled and operated through a baycomputer with different sets of software. The modern technology with the functions defined in software, makes it possible to standardise the wiring and make the whole customisation in the software. All the wiring is prefabricated before the assembly in the factory. This improves the final quality and simplifies future maintenance. The total wiring is also heavily reduced compared with conventional technology. 2

1.5 Support cubicle as outside interface with integrated auxiliary voltage supply All outer connections for control are collected in one separate cubicle, sometimes equipped for special function, like revenue metering. This cubicle may also be equipped with a trolley housing batteries for the auxiliary supply. The battery loading and monitoring unit is integrated in the trolley. This offers a very compact solution for many cases, when a special place for this equipment is not necessary. The battery system is mounted on a withdrawable truck in the support panel. 2. High service reliability and maximum safety for the personnel Service reliability and safety for the operating personnel are in many ways two sides of the same coin Occurring problems of one of the sorts often implicates the other. Some features of the AX1 concept are specially contributing to high reliability and safety. 2.1 Electrical operation and interlocking with integrated monitoring The safest possible operation is the remote electrical operation, which is a standard feature for both circuit-breakers and disconnectors. Operations may also be made locally, but always electrical. This means that also the interlocking between different apparatus are electrical, as a part of the software for operation and control. The disconnector replaces the racking mechanism for withdrawal of the whole breaker, compared with the metal-clad switchgear. A disconnector is generally a more reliable component than the more complicated racking mechanism. The disconnector and the circuit breaker co-operates in the cable-earthing operation. The disconnector first disconnects the circuit breaker from the bus-bar and connect it to the earthing bar of the switchgear. This is of course made with the circuit breaker in open position. After that the circuit breaker is closed and connects thus the cable to the earthing bar. The circuit breaker is a very reliable earthing switch, capable of a big number of closing operations with full short circuit current. The whole operation sequency is made automatically at one command. Earthing of the bus-bar is a very rare case for this switchgear, since all important parts for maintenance are accessible from outside. All electrical functions have a high degree of built-in monitoring. 3

2.2 Bus-bar technology for high service reliability and compact dimensions AX1 is an air-insulated switchgear for maximum 24 kv of about the same size as a gas-insulated switchgear for the same rating. The total dimensions have been minimised by the optimisation of the design from dielectric point of view. The bus-bar system is made of copper tubes, having the ideal geometrical design for an even dielectric field and for the best conductivity per area. The connections are either welded or of a special plug-in design with a helicon spring with a very low total resistance. This way the dependency of the mounting and ageing of a bolt connection is avoided. The bus-bars are built from round tubes, having the ideal electrical field and the most efficient current carrying capability. The connetions between the tubes are either welded or made by special flexible spring-contacts. Both those contact types are more reliable than the conventional bolted contact, which is dependant from the assemble quality and affected by temperature cycling and material saturation. The spring contacts are formed as a helix with many turns, resulting in a high conductivity and flexibility. The contacts are silver plated, greased and covered with a rubber protection gasket to increase the resistance to aggressive environments. Even though the bus-bar concept is relatively new, the type of spring contact has been used for many years in high voltage circuit breakers with a very good experience. Uniformed electromagnetic fields make a compact design with small phase-to-phase clearances. The O-ring and sealing gland protect the coil springcontacts as per degree of protection IP6X. 2.3 Pre-fabricated touchable cable connections The old type of on-site fabricated cable connections has caused many flash-overs, when not properly made. They may also be destroyed by mice, if they can enter the switchgear. AX1 is designed only for pre-fabricated cable connections. For ratings up to and including 1250 A regular outer-cone connections are used. For higher currents a new type of plug-in connections has been developed. The connections to the switchgear are single-phase and covered by metal, in principle touchable. This simplifies the design of the cable compartment, since open arcs cannot occur in this compartment. Outer cone cable termination for max 1250A Plug-in type >1250A 4

2.4 Internal arcs immediately eliminated An open arc due to a severe fault in a switchgear is basicly prevented by a good design of the switchgear and its components, including the prevention of animals to enter the high voltage enclosure. The hazard to personnel in front of the switchgear in case of an internal arc is evaluated by the special type test according to IEC 60298. This is not a mandatory test, but more and more demanded by the switchgear users. It proves the resistance of the encapsulation to the high temperature and the following high pressure caused by open arcs inside the encapsulation. It does not deal with the poisonous gases created by the arc burning in air on copper bars. If those gases (nitrous and others) are let out in the switchgear room, this will become a very dangerous place for the personnel. Both the hazard for the personnel and the damage of the switchgear by the arc is very dependant of the arcing time. The thermal damage is substantially limited even with an arcing time beow 100 ms, compared with an arcing time of 1s. To limit the mechanical damage, caused by the high pressure from heated internal air, the arcing time has to be reduced below 10 ms. The normal time for opening pressure release flaps in arc-proof switchgear is 20 40 ms. This defines the maximum pressure, normally 0,5 to 1 bar gauge. The AX1 switchgear has an integrated extremely fast acting Arc Eliminator, eliminating the arc within about 5 ms. An open arc is detected by an optical sensor and the device connects automatically the bus-bars to earth. The arc fault is converted to a normal short circuit, interrupted in the normal way. The switchgear is designed to withstand the short circuit forces and the very short arcing time does not cause any high pressure, nor any thermal damage at all. This also means, that there is no problem with poisonous gases in the switchgear room special outlet channels to protect people from such gases are not needed. It also means, that different compartments are not needed to limit the arc damage to a certain part of the switchgear. The Arc Eliminator thus contributes to a very simple and safe design of the high voltage part of the switchgear, with air insulation instead of partitions with bushings. The arc eliminator is a standard device in AX1, even though the design of the switchgear has been proven to withstand an internal arc for 1 s. The Arc Eliminator is possible to reset by opening after a closing operation. The arc eliminator is integrated in the busbar-support insulators Operating sequence of active arc eliminator 5

2.5 Modern voltage and current sensors Rogowski coil current sensors are standard for protection measurement. These sensors cover the whole range of currents, from small normal current to short-circuit currents. Conventional current transformers sometimes have to be reconnected to keep their sensibility at increased normal current of the feeder. This operation is not applicable for the Rogowski sensors, which also contributes to keep the main circuit compartment free from access during all its service. For voltage measurements and indications resistive and capacitive voltage dividers are used. These have no iron and thus no ferrous-resonance problems. 3. Easy and fast installation on site 3.1 Pre-installation of cable compartments and cable connections A conventional switchgear consists of a number of cubicles, mounted together in a row at site. After the switchgear installation the cables may be cut in proper lengths and connected inside the cubicles. The AX1 concepts offers an installation possibility the other way around. The basic cubicle of AX1 is excluding the cable connection compartment. This is created by a framework of aluminium profiles, delivered as flat packs to the site. The framework may be fully mounted before the delivery of the cubicles. A simple tool is available, to indicate the precise location of the cable connection points of the cubicles. By this the pre-fabricated cable connections may be fully mounted in advance and later fast connected to the cubicles after their installation. Lower framework with cable termination adapter. 3.2 Fast installation of cubicles with plug-in bus-bars and pre-tested wiring and software The assembly of the cubicles on the plane pre-mounted framework is very simple. The plug-in type of bus-bar connections are easy to finalise and the auxiliary cable connections are also prepared with plug-in contacts. The soft-ware and wiring has been tested in the factory before delivery. All this decreases the installation time of the switchgear substantially. Together with short delivery times, possible by the highly standardised concept, the total time from order to service may be very much reduced. 6

4. A compact air-insulated switchgear The overall design of the main circuit compartment with the tubular bus-bars results in a very compact switchgear, comparable with gas-insulated designs, even though it is airinsulated. A switchgear room needs space not only for the switchgear itself but also to provide a safe situation for personnel in the room. Different regulation specifies the necessary space for withdrawal of breakers and safe escape from the room in case of a severe fault. Normal swinging doors opens into the operating area and may severely danger the escape possibilities. So does circuit breaker trolleys, parked in front of the switchgear. The AX1 concept gives access to important parts of circuit breakers, still inside the switchgear. It also has doors sliding vertically, never interfering with the operator area. The result is decreased total space requirements and increased personnel safety. The sliding doors also gives better survey and makes the work easier. 5. Designed with Environmental Care An important issue for the design of new products is to minimise the environmental impact of the product for its whole life cycle. This means that the material shall be recyclable and the amount of energy needed for production and usage (service losses) shall be minimised. During the last decade different algorithms have been developed for this assessment, called Life Cycle Assessment, LCA. Every analyses is made with different focus and in different detail. It is therefore not possible to present one single value of the environmental load for a certain product. The calculation is however very useful to compare different design alternatives for a product, and assessments for alternative products are comparable, if they are made with the same conditions. AX1 has been developed with LCA as a tool for the choice of material and technology. The overall compact solution contributes highly to the lower environmental load compared with conventional switchgear. As a result of the analyses insulated bus-bars have been avoided, to make the material recyclable. An interesting fact is that aluminium, used as profiles in both the front and the framework, has a low environmental impact compared with other metals, if it is recyclable, but a high impact if it is not recyclable. This is due to the relatively high amount of energy needed to make the metal from bauxite and the low amount of energy needed to melt aluminium at recycling. It is also obvious from an LCA, that the energy loss by the switchgear itself gives a substantial contribution to the total environmental load from the cradle to the grave. This gives an extra bonus for the high current carrying capability also for lower rated feeders, that is a result of the consistent standardisation of AX1 with a minimum of different variants of bars. 7