Overview of Standards for CO Detection Products



Similar documents
908.7 (New) [IBC [F] (New)], (New), Chapter 47 (IBC Chapter 35)

CSA Group and Certification Marks

Safety & Performance in the Wire and Cable Industry

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Fire & Security DETECTORS

Effective June 27, TEXT (CO Detection Commercial Buildings)

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section , to read as follows:

ICC CODE CORNER 2012 IFC Code & Commentary

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

City of Los Angeles NAMES LIMITS OF APPROVAL APPROVED UNTIL. Recognized for: - Approval of all electrical equipment

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

TABLE OF CONTENT

Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Carbon Monoxide Alarm System - Frequently Asked Questions

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

How To Install A Carbon Monoxide Detector

Low Frequency Notification Appliances

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Vilter motor starter solutions The NEW industry standard in motor starter packages

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Lockout Specification BW Clip Maintenance-free single gas detector

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Carbon Monoxide Detection in Commercial Buildings (

System-Connected Carbon Monoxide Detectors

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

The New Paradigm for Medical Device Safety. Addressing the Requirements of IEC Edition 3.1

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Component acceptability for CE product Safety

GAS AND FLAME DETECTION

Simon XTi Installation Guide

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

NATIONAL FIRE ALARM AND SIGNALING CODE

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ex.com. ID 4016 Rev A

CalMod Design-Build Electrification Services

EMERGENCY LIGHTING AND CONTROL

CE Marking: Your Key to Entering the European Market

H.V.A.C. Design Plumbing Design

PLAN REVIEW GUIDE FOR FIRE ALARM

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE

DUCT SMOKE DETECTOR D4120

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Electrical Contractors. and the. New Jersey. Rehabilitation Code

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Ammonia Detection System Codes and Design Specifications

2014 Limited Plan Submittal Checklist

Carbon Monoxide (CO) Gas Detection and Control System

Automatic fire-extinguishing systems for commercial cooking

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

HERNANDO COUNTY FIRE ALARM GUIDELINES

Y7230A CO 2 Alarm System

aseries A13B Mini Bullet Camera User Manual

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

White Papers: Delayed Egress Hardware

BERMAD Fire Protection

1.0 General. Inspection, Testing, and Maintenance 1 of 8

Alarm Systems Using Wireless or Other Transmission Technology as a Single Path of Communication. Purpose. References. Description of Code Reference

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Rosemount 333 HART Tri-Loop

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

SECTION FIRE ALARM AND DETECTION SYSTEMS

SECTION DETECTION AND ALARM

CO2 Alarm. Operation. Application

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Buckeye Detection Systems Fixed Detection Systems Application Survey

The Mission Critical Fire Protection Experts

Chlorine Gas Detection System Operation & Maintenance

NFPA Fire Fighter II

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Fire Alarm System Monitoring - CAN/ULC-S561-03

Module 4, Lesson 12 Fire Alarm Systems

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

NEMA SB Guide for Proper Use of System Smoke Detectors

UL 2560 and Emergency Call Systems: Expanding the Standards Framework

functional Safety UL Functional Safety Mark

Who sets the rules for electrical testing and safety?

Fire Alarm System Accessories

CompactLogix Power Supplies Specifications

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

ENGINEERING SPECIFICATIONS

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller

S-series DeviceNet Interface Card

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Transcription:

Overview of Standards for CO Detection Products Rev 1.1 INTEC Controls 12700 Stowe Dr., Suite 100 Poway, CA 92064 The Right Choice info@inteccontrols.com www.inteccontrols.com Phone: (858) 578-7887 Fax: (858) 578-4633

1 General Overview... 3 2 Application and Installation Codes & Standards... 3 3 Product Standards... 4 4 Certified and Listed Products (Conforms to ANSI/UL Standards)... 6 5 State & City Authorities and Building Inspectors... 8 6 Performance... 9 7 The Right Choice... 10 INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 2 of 10 Printed in USA 100511

1 General Overview The commercial building industry (i.e., building owners and operators, design professionals, and institutions) is concerned about environmental safety and minimizing energy costs. When designing and choosing a carbon monoxide (CO) detection and control system for a parking structure, it is essential to evaluate established codes and standards. 2 Application and Installation Codes & Standards Various institutions, societies, organizations and government agencies (i.e., International Mechanical Code (IMC), Occupational Safety and Health Administration (OSHA), National Fire Protection Agency (NFPA), and other) have established codes and standards to limit carbon monoxide levels in parking structures. Most building codes and application standards allow demand-based ventilation in enclosed parking garages if carbon monoxide levels are monitored. This type of design can drastically reduce energy costs (i.e. operating of garage fans and heating system), increase fan belt and motor life, and reduce noise. A range of gas detection (sensors/transmitters) and control systems are available for handling the sequence of operations in parking structure applications. The actual parking structure s design will determine which type of gas detection (sensor/transmitter) and control system best fits the application. For additional information please refers to INTEC Controls CO Parking Garage Design Guidelines. The selected detectors (sensors/transmitters) and controllers must be capable of providing the control sequence of operations and alarming for the mechanical system design and building safety. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 3 of 10 Printed in USA 100511

3 Product Standards The American National Standard Institute (ANSI) and Underwriters Laboratories (UL) have issued appropriate standards (i.e. ANSI/UL2075, ANSI/UL2017, etc.) applicable for carbon monoxide (CO) detection and control products. Only utilize CO product solutions that are tested, certified, and listed for the intended use and in compliance with the industry s standards. Electrical Safety and Performance Codes & Standards for Gas Detection and Control Systems Products Standards and technical regulations exist for gas detection, alarm and control systems in order to impose electrical safety and performance protection for the building owner & user. Many organizations and authorities participated, in a partial or full capacity, in the process of establishing codes and standards, i.e., recommending, developing, writing, establishing consensus, preparing and publishing, and enforcing protective standards. OSHA (Occupational Safety and Health Administration) OSHA establishes and enforces protective standards to save lives, prevent injuries, and protect the health of America s workers. NFPA (National Fire Protection Association) The NFPA establishes fire safety standards, including those standards for the safe operation of process. ANSI (American National Standards Institute) ANSI is a private, non-profit organization that administers, promotes, and facilitates the U.S. voluntary consensus standards and conformity assessments. ANSI is also the official U.S. representative to the International Electrotechnical Commission (IEC) and the International Organization for Standardization (ISO). The National Electric Manufacturers Association (NEMA) publishes a number of their standards. ISA (Instrument Society of America) ISA is globally recognized as a standard writing organization, developing consensus standards and protecting facilities from flammable hazards. UL (Underwriters Laboratories) UL is an independent, non-profit organization. They participate in developing standards to enhance public safety, preserve the environment, and facilitate trade. In addition, UL is a NTRL (Nationally Recognized Testing Laboratory), approved by OSHA. International CSA (Canadian Standard Association) CSA is a non-profit association serving business, industry, government and consumers in Canada and the global marketplace. They work to develop standards to enhance public safety, preserve the environment, and facilitate trade. In addition, CSA is a NTRL (Nationally Recognized Testing Laboratory), approved by OSHA. IEC (International Electrotechnical Commission) IEC is the leading global organization that prepares and publishes international standards for all electrical, electronic and related technologies. These serve as a basis for national standardization. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 4 of 10 Printed in USA 100511

EU (European Union) The EU is a treaty-based, framework institution that defines and manages economics and political cooperation. The EU covers many issues, such as the environment, agriculture, trade, energy and transport, and mandates various standards, and directives to which manufacturers must comply. The following is a list of directives to which gas detection equipment manufacturer must comply. EC (European Conformity) The CE Mark is the official marking required by the European Community for all electric and electronic equipment that will be sold, or put into service, anywhere in the European community. It ensures that a product fulfills all essential safety and environmental requirements as defined by the EU (European Union) through the European Directives. ATEX (Atmosphere Explosive) The ATEX Directives are EU (European Union) legislation enforced since July 1, 2003. They are intended to standardize, clarify, and improve the way in which equipment used in explosive atmospheres is modified, utilized, and maintained across the EU. The purpose of the directives is to align technical and legal standards while promoting the free movement of goods throughout the EU. EMC (Electromagnetic Compatibility) The EMC Directives set essential apparatus protection requirements while dictating the electromagnetic disturbance a product may generate or be immune to. The directives are in accordance with EU standards defining the technical requirements necessary to achieve the required level of protection. The EMC Directives are applied to electrical equipment and components, domestic appliances, and industrial appliances. LVD (Low Voltage Directive) The LVD Directives apply to all electrical equipment. They are designed to operate in the voltage range of 50-1000 VAC or 75-1500 VDC. The Directives ensure that all electrical and electronic equipment placed on the market in the EU is safe. For more details and specific information, visit the websites of the appropriate organization and/or government authorities. Any carbon monoxide (CO) detection system selection done by specifying engineers, installers and building owners should include solutions that are in compliance with industry standards. Every HVAC, Security, Controls and Building professional should understand the differences between the American National Standard Institute (ANSI) and Underwriters Laboratories (UL) standards ANSI/UL 2075, ANSI/UL 2017 and ANSI/UL 2034, and be aware of the new ANSI/UL2075 requirement that became effective at the end of 2009. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 5 of 10 Printed in USA 100511

4 Certified and Listed Products (Conforms to ANSI/UL Standards) Major Authorized NRTL CSA Canadian Standard Association (also known as CSA International) FM FM Approvals LLC (formerly Factory Mutual Research) INTERTEK / ITSNA Intertek Testing Services NA, Inc. (formerly ETL) TUV / TÜV TÜV SÜD America, Inc. (TUVAM) TÜV SÜD Product Services GmbH (TUVPSG) TÜV Rheinland of North America, Inc. (TUV) UL Underwriters Laboratories Inc. An additional six (6) approved/certified NRTL companies are available visit OSHA s website for details. Only CSA, Intertek and UL are currently certified to test to Standard ANSI/UL 2075. Nationally Recognized Testing Laboratory NRTL An organization that is approved by OSHA (Occupational Safety and Health Administration) to independently test, certify and conform electrical instrumentation and control products to the appropriate standards, and to provide product listing and labeling. Only choose CO product solutions that have the appropriate NRTL listing and label. Existing USA Standards and Certification applicable for Carbon Monoxide Detectors, Transmitters & System Controllers For Scope / Applications (key excerpts) Standards Title Applies to the following electrical products and applications: ANSI/UL 2075 Standards for Safety Gas, Vapor Detectors and Sensors/Transmitters. Commercial Buildings Commercial Buildings Multi-gas sensors/transmitters Multi-gas detectors Solely for control of ventilation or shutting off devices such as fans or control valves For operating as part of gas detection or emergency signaling systems Note: It is not appropriate to use ANSI/UL 2075 "residential type of detectors for commercial applications. Includes ANSI/UL 2034 Comments: Standard ANSI/UL 2075 incl. sensor/transmitter performance tests, and sensitivity testing to ANSI/UL 2034 NFPA in their application standard NFPA 720, 2009 edition, for installation of CO detection and warning equipment, states: Each carbon monoxide detector (senor/transmitter) shall be in compliance with ANSI/UL 2075. Also, gas and vapor detectors (sensors/ transmitters) shall meet the sensitivity tests and alarm thresholds of ANSI/UL 2034, the standard for single and multiple station carbon monoxide alarms. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 6 of 10 Printed in USA 100511

Applies to the following electrical products and applications: ANSI/UL 2017 Standard for Safety General-Purpose Signaling Devices and Systems. Commercial Buildings Commercial Buildings Commercial Buildings Residential Dwellings Self-monitored devices or systems are intended to be self-monitoring. These devices are intended for, but not restricted to, commercial use. A product a covered by these requirements consists of a unit assembly of electrical parts having provision for the connection of power supply circuits routed through the equipment by a prescribed scheme of circuiting. Circuits extending from the products connect to separate devices by which the operating part of the product is actuated for signals, and to separate and/or integral devices by which the signals are indicated so as to form a coordinated system combination for definitive signaling services. An installation wiring diagram attached to the product, or referenced in the product marking, indicates the devices and circuits which have been determined to be capable of being used with the product in the field. Installed and used in accordance with the National Electrical Code, NFPA 70. Applies to the following electrical products: Control equipment Test and measurements Laboratory equipment Accessories Applies to electrical alarms intended for: Indoor locations of dwelling units Recreational vehicles Mobile homes Boats, enclosed spaces ANSI/UL 61010-1 IEC 61010-1 ANSI/UL 2034 Comments: Commercial CO detection and control systems for parking garages (i.e., a central control unit connected with multiple sensors/transmitters, analog or digital bus types), located across the parking space controlling ventilation and alarming, shall be certified products conforming to: - ANSI/UL 2017 for controller/central control unit - ANSI/UL 2075 for sensors/transmitter (detectors) Standards for Safety Electrical Equipment for measurement, control, and laboratory. Comments: Standard ANSI/UL61010-1 does not include sensor/transmitter performance testing. For commercial garage CO detection and control systems, the latest revised standards call for products with NRTL certification that conforms to ANSI/UL 2075 (CO sensors/transmitters) and ANSI 2017 (central control units). Many local authorities (building and safety departments), are known for strict enforcement of local codes and standards within their jurisdiction. This includes the cities of Los Angeles, San Diego, Chicago, Orlando, New York City, as well as the states of North Carolina, Oregon and Florida. The building inspectors will look for the appropriate NRTL listing on the installed products. Standard for Safety single and multiple station CO alarms. Comments: Products NRTL certified to ANSI/UL 2034 are intended for residential applications and should not be connected to a commercial central control and alarm system panel. Note: For the complete and exact definition (title, scope, etc.), please refer to the officially issued standards available through the respective organizations, i.e., OSHA, NFPA, ANSI and/or any NRTLs. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 7 of 10 Printed in USA 100511

5 State & City Authorities and Building Inspectors State and local inspectors, who are empowered by their authority having jurisdiction (AHJ), have universally adopted the National Fire Protection Agency, standard NFPA 70, also known as the National Electrical Code (NEC). Some authorities and their inspectors are known for strict enforcement beyond the local electrical codes and may require the installed CO detectors (sensors/transmitters) and controllers to be NRTL listed. Los Angeles, San Diego, Chicago, Orlando, New York City, and as well the states of North Carolina, Oregon and Florida are some examples. The inspector or building official may red tag installed, unlabeled equipment as unfit for operation until the applicable product safety requirement is met or replaced with a NRTL listed product. Local authorities, building owners and operators have been dissatisfied in the past with many of the substandard commercial carbon monoxide (CO) detection equipment, which emphasized electrical safety only. The new ANSI/UL 2075 standard was eventually developed and adopted to address both electrical safety and product performance. The National Fire Protection Association (NFPA) in their application standard NFPA 720, 2009 edition, for installation of CO detection and warning equipment, states: Each carbon monoxide detector shall be in compliance with ANSI/UL 2075. Also, gas and vapor detectors and sensor/transmitters shall meet the sensitivity tests and alarm thresholds of ANSI/UL 2034, the standard for single and multiple station carbon monoxide alarms. Only install CO solutions which have been thoroughly performance tested and their product specifications accurately verified. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 8 of 10 Printed in USA 100511

6 Performance Various designed and manufactured CO sensors/transmitters offer differing levels of accuracy, repeatability, detection with or without cross sensitivity to other gases, and sensor element life span. These factors will influence the performance and operating costs of the mechanical and CO detection system. The market offers mainly two types of CO gas sensing element technologies for commercial garage applications electrochemical and solid state Technology Accuracy PPM CO Life Span Features Electrochemical Type High Accuracy < +/- 1 5+ years Detects the true level of CO in ppm Reduced drift High accuracy & reduced drift means fewer calibration intervals Electrochemical Type Standard +/- 3 < 5 years Solid State / Semiconductors (MOS) Type 1 Solid State / Semiconductors (MOS) Type 2 +/- 7 to 15 7+ years Unknown 2.5 years Solid state sensors: Are cross sensitive and prone to false alarm Subject to drifts of readings at sizeable space, temperature and/or humidity change Require more frequent calibration intervals The CO central controller should have the capability to fulfill all required sequence of operation, provide selfdiagnostic with malfunction warning, intelligently identify each individual sensor/transmitter s detection value and local and remote alarms, and sensor element s End-of-Life (EOL) fail-safety alarm. Review the product data sheet s specifications and select the solution that will secure an economical installation, provide safety and performance to fit the mechanical system design, and lower calibration intervals. INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 9 of 10 Printed in USA 100511

7 The Right Choice The analog or digital multi-point bus CO detection and control systems for commercial parking structures should provide: Sensor/transmitter: NRTL Performance Tested & Certified, conforming to STD ANSI/UL 2075 Central Controller: NRTL Tested & Certified, conforming to STD ANSI/UL 2017 INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064 www.inteccontrols.com Page 10 of 10 Printed in USA 100511