Movable Wall 8-Wire Base Electrical System - Product Notes



Similar documents
electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Resolve System. Z Resolve System Price Book (9/15) 1. Prices effective February 2, Published September Price Book

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Malibu Monte Carlo El Camino

ELECTRIC CONVECTION BUILT-IN OVEN

Power. When and where you need it.

Utility Distribution Systems

AMPSEAL* Automotive Plug Connector and Header Assembly

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Minimum Standards for Data/Voice Infrastructure in New Building Construction

For Models #6-5001, #6-7501, # & #10-12K1

DC Series Digital Conversion Alarm Operator s Manual

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

HP UPS R1500 Generation 3

Description. Lesson Outcomes. Assumptions. Terminology. Electrician

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Electrical. This section applies to the design and installation of building power distribution systems.

FASTON Terminals and Connectors

DN1600 MEGA SPIN Installation Guide INNOVATIVE CONCEPTS IN ENTERTAINMENT INC MAIN STREET, CLARENCE, NY SERVICE: FAX:

Vertical Phone System Upgrades Scope of Work

Mazda CX

id led square housing FL44

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

Electrical/ Communications. Panel Based Systems

Understanding Electrical Terms

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

TSn SERIES Surge Protective Device

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

SECTION TELECOMMUNICATION ROOMS

Errata NFPA 70. Proposed 2014 Edition

id led 4" square housing FL44

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

DVI DA2 and DVI DA 4 User Guide

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

GENERAL WIRING RULES FOR HOUSES

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

Universal MATE-N-LOK Connector System

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Customized Server Cabinets

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Quick Connect Boxes Inside Gloveboxes

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

AU-110 racking guide NBXPN: 023

PowerPlus. Integrated Power Distribution Cabinets. Most effective space-saving. integrated system on the market. Engineered to be shipped as a

Part Name/Description Part Number Quantity. Power Cable


ICON Server box installation manual Rev. 1.1

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Cooktop Low-Profile Ventilation Hoods

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Operation Manual. Trans-Flo

Extollo Communications. Home Electrical Wiring and Cross Phase Coupling Overview

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

Power Supply Specifications

Generator Transfer Switch Model # HTS15-AUTO

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

Model 201 Wiegand Touchpad Reader Installation Guide

HARTING Ethernet Cabling 8-poles Overview

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

ORIGINAL CABLE PLATES

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Chevelle Chevelle. (500645) Gauge Cluster Kit Installation Instructions. (500645) Gauge Cluster Kit Installation Instructions

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

VS CONTROL PACK INSTALLATION INSTRUCTIONS

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

Nevco, Inc. Installation Manual

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

LED Wiring and Connections

Model SETR-50 and SETR-51 Trim Tab Control

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Figure 1-A This end of the cable is the side that will be plugged into the power adapter and DVR Card.

Cross-beam scanning system to detect slim objects. 100 mm in

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

8146/5 Series Breaker Panelboards

For 100 Amp Automatic Transfer Switch/Load Center Models: 10 Circuit, 12 Circuit and 16 Circuit. Installed with 7, 10, 13 and 16kW Generators.

Installation Guide Solar Connect-11

Fan, Cypress / GreenField Installation Instructions (sku )

1247 Norwood Avenue, Itasca, IL (800)

CHENBRO. RM Port 6Gb/s Mini-SAS Backplane 80H A0. User s Manual. Sep / 30 / 2010

PAM Connectors. PAM Bayonet Connectors

BB -508L/509L INSTALLATION MANUAL LATTICE BOOM CRANES. Greer Company Crane Systems. Greer Company

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)

Digital Keypad Use s Manual

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installation Instructions

Transcription:

Movable Wall 8-Wire Base Electrical System - Product Notes V2250 Base Power Entry This power entry connects a building s electrical supply from a wall, floor or column to the base electrical system. It distributes up to 4 20-amp circuits and includes a 6 cable, which can be field cut to appropriate length. It plugs directly into a Base Power Block using the receptacle connection point. Power entry is UL listed and CSA certified. Note: Licensed electrician must wire power entry. Note: Not handed. 72" V2251 Ceiling Power Entry This power entry connects a building s electrical supply from ceiling access to the base electrical system. It can be run vertically through a panel, spacer, 3-way, 4-way or 90 degree corner. It distributes up to 4 20- amp circuits and attaches directly to a Base Power Block at any one of the four distribution connections. Power entry is UL listed and CSA certified. Note: Licensed electrician must wire power entry. Note: Special oval conduit comes with utility box connector and is 16 long with 17 wires. 16' 1' V2254 Power Jumper This power jumper distributes up to 4 20-18", 21", 24", 36", 42", 48", 54",72", 96" or 120" amp circuits and attaches directly to a Base Power Block at any one of the four distribution connections. Power Jumper is UL listed and CSA certified. V2254.18= 18 length, V2254.21= 21 length, V2254.24= 24 length, V2254.36= 36 length, V2254.42= 42 length, V2254.48= 48 length, V2254.54=54 length, V2254.72= 72 length, V2254.96= 96 length, V2254. LA= 120 length. Note: Lengths are net usable. For block-to-block connections, figure center-to-center of panels and deduct 6 for single or 11 for double Power Block units from that total. Note: Power jumper has 3 extension capability and can reduce net length 2 in every two feet by weaving in base cavity. Note: Jumper is encased by flexible oval conduit. V2255 Jumper Coupling This jumper coupling connects two power jumpers. This allows extra long extensions or utilization of two shorter components for one longer connection. It distributes up to 4 20-amp circuits and attaches directly to either end of power jumper. Jumper Coupling is UL listed and CSA certified. Note: Coupling has four (4) connection points for splitting or jumping power. 1 3/4" 1 1/4" 2" FRONT SIDE

Movable Wall 8-Wire Base Electrical System - Product Notes page 2 V2256 Systems Power Adapter The Systems Power Adapter connect to a Base Power Block and adapt for connection to Herman Miller Series 2,3 and Ethospace 8-wire systems electrified panels. It is similar in function to the Internal Direct Connect by attaching to the systems panel electrical harness at the receptacle location. Adapters distribute up to 4 20-amp circuits and are fully compatible. Systems Power Adapter is assembled from UL listed and CSA certified components. A, B or C Note: Base Power Block must be under a 24 or 30 Movable Wall panel next to Systems Adapter. Note: Order the A length adapter is for connection to systems panels with widths of 24 and 30, order B length adapter for 36 and 42, order C length for 48 and larger width system panels. V2258 Base Power Block (single or double) The power block provides single or double attachment point for Receptacles, System Power Adapters or Base Power Entry on both sides of the panel. The.1 option is for the single per side unit and the.2 option is for the double per side ports. Power block offers two distribution connections at each end and distributes up to 4 20-amp circuits. Base Power Block is UL listed and CSA certified. 5 1/8" 1 3/4" 10 1/4" 2 1/4" 3" SINGLE END VIEW DOUBLE Note: Single Block may be used when under a panel with ceiling power entry. V2259 Receptacle, 4 Circuit The receptacle locks into the Base Power Block. Receptacle is UL listed and CSA certified. Note: See Action Office Series 2 Planning Guide for information on types of receptacles and their applications. Note: Includes 18 section of base trim for field installation. Note: Duplex receptacles are packaged 6 to the box. Note: Surge suppressed receptacles are packaged 1 to the box. 3-7/16 C 1-13/16 DESIGNATES ISOLATED CIRCUIT (CIRCUIT LETTER & SYMBOL IN ORANGE) DESIGNATES CIRCUIT (CURCUIT LETTER IN WHITE)

Typical Base Electrical Product Application Detail B Detail A Detail C Detail D Detail A Behind Base Trim (V-Wall shown) V2254 Power Jumper V2256 Systems Adapter V2251 Ceiling Power Entry V2130.4 Wireway 4 Panel System electrical harness receptacle location

Detail B Power Connection Detail Whip End of V2251 Ceiling Power Entry, final connection hook-up by local code authorized electrician (above ceiling) Whip is fed through electrical access holes in V2210 Ceiling Runner Panel or connector pass-through Detail C Receptacle Detail Detail D Base Power Entry Detail V2130.4 Wireway 4 V2259 Receptacle V2254 Power Jumper V2250 Base Power Entry Whip End of V2250 Base Power Entry, final connection hook-up by local code authorized electrician

Distribution Cabling Methods 90 Degree Corner Straight Through Connection Three-Way Connection Four-Way Connection Wiring Schematic Printed on Receptacle a b c d c b b c d circuit 1 circuit 2 circuit 3 circuit 4 circuit 3 circuit 2 circuit 2 circuit 3 circuit 4 isolated isolated isolated isolated isolated dedicated Terminals 10 Ga. Gray Neutral-2 10 Ga. White Neutral-1 12 Ga. G/Y Iso.Grnd. 12 Ga. Green Ground 12 Ga. Pink Hot 4 12 Ga. Blue Hot 3 12 Ga. Red Hot 2 12 Ga. Black Hot 1 in orange print

Movable Wall 8-Wire Base Electrical System New York City Addendum NY2250. (special) New York City Power Entry This power entry connects a building s electrical supply from a wall, floor or column to the 4 circuit 8 wire base electrical system. It distributes up to 4 20-amp circuits and includes cable as shown, which can be field cut to appropriate length. It plugs directly into a Base Power Block or Jumper Coupling using standard cable connection point. Power entry is UL listed. Note: Licensed electrician must wire power entry. Note: Not handed. Elevation View Parts View 14-3/4 Minimum compressed 17-3/4 Maximum extended 14 Ref. 72 Max 2 Top View 1-1/2 Assembly Unit ships as two pieces. Certified electrician must assemble and complete hook-up to building power supply. Base_ElectricNYC.pdf