Office of the Government Chief Information Officer. Green Data Centre Practices



Similar documents
Best Practices. for the EU Code of Conduct on Data Centres. Version First Release Release Public

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Green Data Centers development Best Practices

- White Paper - Data Centre Cooling. Best Practice

2010 Best Practices. for the EU Code of Conduct on Data Centres. Version Release Public Review Public

DataCenter 2020: first results for energy-optimization at existing data centers

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Benefits of. Air Flow Management. Data Center

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Analysis of data centre cooling energy efficiency

News in Data Center Cooling

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

How To Improve Energy Efficiency In A Data Center

APC APPLICATION NOTE #112

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Managing Data Centre Heat Issues

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Australian Government Data Centre Strategy

Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire

2014 Best Practices. for the EU Code of Conduct on Data Centres

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

How To Improve Energy Efficiency Through Raising Inlet Temperatures

EU Code of Conduct for Data Centre Efficiency

Data Center Energy Profiler Questions Checklist

Rack Hygiene. Data Center White Paper. Executive Summary

THE GREEN DATA CENTER

2014 Best Practices. The EU Code of Conduct on Data Centres

Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire.

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Environmental Data Center Management and Monitoring

How To Run A Data Center Efficiently

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data Centre Cooling Air Performance Metrics

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Server Room Thermal Assessment

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Energy Efficiency and Availability Management in Consolidated Data Centers

Improving Data Center Energy Efficiency Through Environmental Optimization

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Green Data Centre Design

Data center upgrade proposal. (phase one)

Direct Fresh Air Free Cooling of Data Centres

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

ICT and the Green Data Centre

Re Engineering to a "Green" Data Center, with Measurable ROI

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Elements of Energy Efficiency in Data Centre Cooling Architecture

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

State of the Art Energy Efficient Data Centre Air Conditioning

Cisco Data Center Facilities Assessment Service

Great Lakes Data Room Case Study

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Power and Cooling for Ultra-High Density Racks and Blade Servers

abstract about the GREEn GRiD

TIA-942 Data Centre Standards Overview WHITE PAPER

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Choosing Close-Coupled IT Cooling Solutions

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Top 5 Trends in Data Center Energy Efficiency

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Driving Data Center Efficiency Through the Adoption of Best Practices

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Airflow Simulation Solves Data Centre Cooling Problem

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.0.0

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

THE ACS BACKGROUND GENERAL COMMENTS

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Capgemini UK Infrastructure Outsourcing

11 Top Tips for Energy-Efficient Data Center Design and Operation

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

White Paper Rack climate control in data centres

Transcription:

Office of the Government Chief Information Officer Green Data Centre Practices Version : 2.0 April 2013 The Government of the Hong Kong Special Administrative Region The contents of this document remain the property of, and may not be reproduced in whole or in part without the express permission of the Government of the HKSAR

Green Data Centre Practices This is a set of recommended green data centre practices, which should be implemented whenever possible. These practices are categorised under the 4 lifecycle stages of data centre management: design, procurement, operations and disposal. 1. Green Design For IT systems: Deployment of new or replaced IT systems Server virtualisation should be considered for deployment of new or replaced IT systems. Virtualisation technology enables multiple systems to run in a single physical server. It helps reduce the number of physical servers and in turn reduce the power required for server operations as well as for cooling of the physical accommodation space that may otherwise be required. According to the Green Grid, virtualisation will lead to energy saving of some 10%-40%. Energy and temperature reporting hardware should be considered whenever possible so as to assist in the implementation of temperature and energy monitoring across data centres. Data management A framework for data life cycle management should be developed, defining which data should be kept, for how long and at what level of security protection. Data life cycle management helps manage the flow of system data throughout its life cycle from creation and initial storage to the time when it becomes obsolete and is deleted. A clear framework can help ensure the minimal set of information is kept to support business needs and avoid wastage of storage resources at the same time. Redundant files or data should be reduced or eliminated to save data storage. - 2 -

For data centre facilities: Air-flow management When building a new data centre or revamping an existing data centre: A design of hot and cold aisles should be adopted. Hot aisle layout means the equipment racks installed back-to-back whereas cold aisle layout means the equipment racks installed front-to-front. Such a design avoids mixing of hot air and cold air, and thus optimises airflow in data centres. A design of containing hot or cold air should be adopted. This design is to separate hot and cold air by installing physical partitions (e.g. vinyl plastic sheeting) for better uniformity of air temperature from the top to the bottom of equipment racks. A structured cabling system (means a standardised wiring infrastructure or system such as using a centralised patch panel or cable tray for cable laying etc.) for improving air-flow should be used. A structured cabling system provides more room within racks to improve air-flow. Groups of equipment with substantially different environmental requirements should be deployed in a separate area. (e) Equipment should be selected with heat dissipation matching the airflow design for the rack to be installed. Measurement of power consumption When building a new data centre or revamping an existing data centre: Meters capable of measuring total energy usage of data centres should be installed. Meters capable of measuring total energy delivered to IT systems in data centres should be installed. - 3 -

2. Green Procurement For IT systems: Procurement of IT equipment Procurement of IT equipment should follow the green procurement requirements stipulated in Environment Bureau Circular Memorandum No. 2/2011. Energy efficiency performance requirements (e.g. Energy Star) should be included in procurement of IT equipment as far as possible. Wide ranges of operating temperatures and humidity should be considered in procurement of IT equipment for saving energy in air-conditioning in data centres. As the ranges of operating temperature and humidity in data centre for IT equipment may be 23 o C ± 3 o C (temperature) and 50% ± 10% (relative humidity) or even wider, IT equipment should be able to operate within this operating temperatures and humidity ranges of the data centre. Power management features should be included in the procurement specification of IT equipment, if applicable. Power management features would facilitate optimal use of energy according to the workload of IT equipment. A typical example is the low-power sleep mode of IT equipment, which will be activated after a period of inactivity. Some servers may be shut down automatically when there is no workload running on the hardware. - 4 -

For data centre facilities: Procurement of chillers A minimum Coefficient Of Performance (COP) complying with Building Energy Code for the Building Energy Efficiency Ordinance should be specified when procuring chillers. COP means the ratio of the rate of heat removal to the rate of energy input, in consistent units, for an air-conditioning equipment. The higher COP, the higher efficiency of an air-conditioning installation is. (Building Energy Code for the Building Energy Efficiency Ordinance: http://www.beeo.emsd.gov.hk/en/mibec_beeo_codtechguide lines.html) Procurement of computer room air-conditioners A minimum Coefficient Of Performance (COP) complying with Building Energy Code for the Building Energy Efficiency Ordinance should be specified in procuring computer room air-conditioners. Variable speed fans should be deployed. Variable speed fans optimise power consumption as they adjust air speed and air flow according to the surrounding temperature. Procurement of uninterruptible power supply (UPS) High efficiency UPS systems complying with Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Systems should be deployed. (Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Systems: http://re.jrc.ec.europa.eu/energyefficiency/code%20of%20 conduct/ups/code_of_conduct_ups_16032011.pdf) - 5 -

Procurement of emergency generator Sufficient power sizing of Generator-Set should be conducted to cater for the power requirements of the installed systems, the expected inrush currents during operations and harmonics returning from the connected installation. Procurement of data centre lighting Energy efficient lighting systems should be used. 3. Green Operations Metrics (e) Carbon footprints of data centres based on energy consumption should be measured / estimated. Carbon footprint = Electricity(kWh) 0.7 (kg/kwh) 1 1000 (kg/ tonne) Power usage efficiencies of data centres should be measured / estimated. Power usage efficiency measures the energy-efficiency of a data centre by comparing the total power consumed by a data centre to the amount of energy that is effectively consumed by IT equipment, showing how effectively the energy is gainfully deployed for operating the IT equipment and the extent that is required for operating the supporting facilities such as cooling systems. Server utilisations should be measured to identify underutilised servers for consideration of consolidation or virtualisation. Storage utilisation should be measured for consideration of consolidation. Network utilisation should be measured to identify inefficient data transmission. 1 0.7 (kg/kwh) is a territory-wide default value adopted in Guidelines to Account for and Report on Greenhouse Gas Emissions and Removals for Buildings in Hong Kong, EMSD and EPD, HKSARG - 6 -

For IT systems: Management of existing IT equipment and systems Unused IT systems should be decommissioned within a reasonable period of time. IT equipment that is idle for a prolonged period of time should be shut down. Power management features on IT equipment should be enabled, if such features are available. Unmanned monitors in data centre should be switched off. For data centre facilities: Air-flow management For existing data centres: Hot and cold aisles should be adopted. Hot or cold air containment should be considered as far as possible. Placement and opening factors of vented tiles should be reviewed regularly to avoid unwanted apertures in the raised floor. Any clutter under the data centre floor, including cabling that might impede airflow, should be cleaned up whenever possible. For equipment racks: (e) (f) (g) Gaps where there is no equipment should be covered (e.g. by installing blanking plates) to reduce cold air passing through gaps in the racks. Cable cut-out tiles should be covered (e.g. by installing aperture brushes) to avoid any anticipated air leakage opportunities. Perforated rack doors should be used whenever possible. Perforated rack doors allow efficient in-take of cold air and dissipation of hot air when the racks are arranged in hot and cold aisles. - 7 -

Cooling management Unnecessary cooling equipment should be shut down to save energy. Cooling air should be moved closer to the IT load to reduce cooling demands whenever possible. Cooling load should be reviewed before any change/replacement of IT equipment (e.g. review placement and flow of vented tiles before change/replacement of each IT equipment). Cooling strategy should be reviewed periodically to ensure effective delivery of cooling air and maintain the system reliability, and achieve economic operational and environmental benefits. Temperature and humidity settings (e) Reduction of cooling requirement in data centre should be explored by increasing the ambient room temperature. Humidity range should be reviewed to increase the upper humidity set point of the data centre to decrease the dehumidification loads within the facility. Chilled water temperature setting should be reviewed to reduce the compressor energy consumption. Cooling system operating temperatures should be reviewed to improve efficiency (e.g. evaluate the opportunity to decrease condensing temperature or increase evaporating temperature in order to reduce delta temperature between these temperatures so that less work is required in cooling cycle hence improved efficiency). Part load operation should be reviewed to improve efficiency (e.g. sequence chillers, operate cooling towers with shared load for increased heat exchange area). - 8 -

UPS management UPS should be deployed in their most efficient operating mode such as line interactive. Management of data centre lighting Lights should be switched off (e.g. lightings preferably automatically switch off whenever areas are unoccupied). 4. Green Disposal Disposal of obsolete IT equipment and data centre facilities Equipment should be refurbished or dismantled for reuse as far as practicable, while disposal of obsolete equipment should comply with relevant environmental legislations/regulation such as Waste Disposal Ordinance. Toners with environmental-friendly features, e.g. refillable toners, toners with recycle scheme after disposal, should be used. - 9 -