How To Understand Evaporator

Similar documents
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Refrigeration Basics 101. By: Eric Nelson

Rusty Walker, Corporate Trainer Hill PHOENIX

Characteristics of Evaporators

Glossary of Heating, Ventilation and Air Conditioning Terms

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Chilled Water HVAC Systems

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

DEFROSTING. Service Engineers Section Technical Bulletin No 3

DESIGN STANDARDS SECTION

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

HOW HVAC WORKS. How HVAC. Works PAGE 1

UNDERSTANDING REFRIGERANT TABLES

How does solar air conditioning work?

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Answers to Your Questions from the Webinar

High School Graduation years 2013, 2014, Unit/Standard Number

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Contents and Nomenclature

How To Clean Water From An Ammonia Refrigeration System

VACUUM REFRIGERATION SYSTEMS

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

Holdover Plates Transport Refrigeration Systems

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Automobile Air Conditioning Primer

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Refrigeration and Air Conditioning Mechanic On-the-Job Training Guide

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

New Trends in the Field of Automobile Air Conditioning

REFRIGERATION & AIR CONDITIONING GUIDE

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

MAC-120HE-01 Air-Cooled Chiller

Lesson 36 Selection Of Air Conditioning Systems

Defining Quality. Building Comfort. Heating and Cooling Coils

Troubleshooting Your Refrigerator

How air conditioning works

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

SEALED SYSTEM DIAGNOSIS

Heavy-Duty Air Conditioning And Heater Service

How To Design A Refrigeration System

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Dehumidification Frequently Asked Questions

Why Daikin? 2015 Houston, Texas USA

Low Profile Unit Cooler

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Heating, Ventilation, and Air Conditioning (HVAC)

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

Product Data Bulletin

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Fundamentals of Mechanical Refrigeration Systems

Why and How we Use Capacity Control

SWIMMING POOL HEAT PUMP

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

KRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

HVAC Systems: Overview

Energy Efficiency. Energy Efficient Home Cooling:

Heat Recovery In Retail Refrigeration

THE PSYCHROMETRIC CHART AND ITS USE

Air Conditioning 101. STN Presentation AC101

Heat Pump Water Heater IOM Manual

Appendix - Controllers 179

REMOTE CONTROL MANUAL

Test Code: 8297 / Version 1

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Glossary of HVAC Terms

Frost. On Air-Cooling Evaporators. refrigeration applications at temperatures below freezing. These heat exchangers

Chapter 3.4: HVAC & Refrigeration System

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Air Conditioning System

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Pool Dehumidification Basics

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

How To Use A Water Source Heat Pump

White Paper #10. Energy Efficiency in Computer Data Centers

Why is my air conditioner dripping on my customers?

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

Testing methods applicable to refrigeration components and systems

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Transcription:

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM

UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration. Determine the boiling temperature in an evaporator. Identify different types of evaporators. Describe a parallel-flow, plate-and-fin evaporator. Describe multiple- and single-circuit evaporators. Describe how a voltmeter is used to troubleshoot an electrical circuit.

REFRIGERATION Process of moving heat from a place where it is not wanted to a place where it makes little or no difference Fresh food is maintained at about 35 F Heat travels naturally from a warmer substance to a cooler substance Mechanical refrigeration is required when heat is to be transferred from a cooler substance to a warmer substance

REFRIGERATION (cont d) Air conditioning is considered to be high temperature refrigeration The evaporator coil is typically at about 40 F The cooled air is mixed with the air in the room Commercial refrigeration systems Some are self-contained, plug-in appliances Can be individual boxes with remote condensing units Several boxes can be served by one large compressor or by a rack of compressor piped in parallel with each other

REFRIGERATION TEMPERATURE RANGES High temperature refrigeration Box temperatures range from 47 F to 60 F Medium temperature refrigeration Box temperatures range from 28 F to 40 F Low temperature refrigeration Box temperatures range from -20 F to 0 F Lower temperature are used for special applications

THE EVAPORATOR Responsible for absorbing heat into the refrigeration system The evaporator is maintained at a temperature that is lower than the medium being cooled Removes both latent and sensible heat from the air in the refrigerated box Latent heat is in the form of moisture Sensible heat reduces air and product temperature

THE EVAPORATOR ACTS AS A SPONGE

THE EVAPORATOR COIL IS COOLER THAN THE MEDIUM BEING COOLED Inside Temp 75 F Heat flows naturally from the air inside the house to the cooling coil (evaporator) Cooling coil at 40 F

BOILING AND CONDENSING The boiling temperature (evaporator saturation temperature) and its relationship to the system exist in the evaporator The condensing temperature (condenser saturation temperature) and its relationship to the system exists in the condenser Boiling and condensing temperatures are related to the high and low side pressures according to the P/T chart

PORTION OF A PRESSURE/TEMPERATURE CHART F R-12 R-22 R-134a R-410a 39 36.1 67.1 34.1 40 37.0 68.5 35.1 118.3 41 37.9 70.0 36.0 120.5 42 38.8 71.4 37.0 THE TEMPERATURES ARE LOCATED IN THE LEFT COLUMN THE PRESSURES ARE LOCATED IN THE RIGHT COLUMNS

WHAT IS THE PRESSURE OF R-22 AT 41 DEGREES? F R-12 R-22 R-134a R-410a 39 36.1 67.1 34.1 40 37.0 68.5 35.1 118.3 41 37.9 70.0 36.0 120.5 42 38.8 71.4 37.0 THE POINT AT WHICH THE ROW AND COLUMN CROSS WILL GIVE US THE PRESSURE OF R-22 AT 41 F

THE EVAPORATOR AND THE BOILING TEMPERATURE Boiling temperature determines the evaporator coil temperature Technicians must know the correct temperatures and pressures for various systems under different operating conditions Relationships exist between air temperatures and evaporator coil temperatures

REMOVING MOISTURE Dehumidifying is the process of removing moisture Moisture removal is similar in similar systems Evaporator coil load changes as the return air temperature changes Removal of moisture is a latent heat transfer Latent heat is also referred to as hidden heat The evaporator facilitates heat transfer between the conditioned space and the refrigerant in the system

HEAT EXCHANGE CHARACTERISTICS OF THE EVAPORATOR Common materials used are copper, aluminum, steel, brass and stainless steel Corrosion factor and application determines the materials used for a particular evaporator Rapid heat transfer rate between two liquids Slower heat transfer rate between two vapors

HEAT EXCHANGE CHARACTERISTICS OF THE EVAPORATOR (cont d) Film factor Relationship between the medium giving up heat and the heat exchange surface Related to the velocity of medium passing over the coil If velocity is low, the film acts as an insulator Temperature difference between two mediums Large temperature difference = high heat transfer rate Small temperature difference = low heat transfer rate

EVAPORATOR TYPES Natural convection (draft) evaporators Made up of bare tubes or pipes Physically large, very low air velocity Located high, near the ceiling of a walk-in cooler Mechanical draft evaporators Use blowers or fans to move air across the coil Improved heat transfer rate Physically smaller than natural draft evaporators

CEILING OF WALK-IN BOX CROSS SECTION OF EVAPORATOR TUBES WARMER AIR FROM BOX RISES

INDUCED DRAFT EVAPORATOR PULLS AIR THROUGH THE COIL

FORCED DRAFT EVAPORATOR PUSHES AIR THROUGH THE COIL

EVAPORATOR TYPES Stamped plate evaporators (cont d) Creates a large heat transfer surface Made of metal plates stamped with grooves that provide a path for the refrigerant to take Finned tube evaporators Increased surface area Multiple circuit evaporators Parallel circuits are created in the coil Results in s reduced pressure drop across the coil

THE STAMPED PLATE EVAPORATOR METAL PLATES STAMPED WITH GROOVES THESE GROOVES ARE MIRROR IMAGES OF EACH OTHER

THE STAMPED PLATE EVAPORATOR

EXCESSIVE PRESSURE DROP IN THE EVAPORATOR 60.5 psig 68.5 psig

COIL DIVIDED INTO TWO PARALLEL CIRCUITS

COIL DIVIDED INTO TWO PARALLEL CIRCUITS METERING DEVICE

COIL DIVIDED INTO TWO PARALLEL CIRCUITS METERING DEVICE

EVAPORATOR EVALUATION MEDIUM TEMPERATURE WALK-IN BOX R-134a box at 35 F, forced draft, single circuit 65% liquid, 35% vapor enters the coil Coil is about 20 degrees colder than the box Pressure is 18.4 psig (20 F from P/T chart) As refrigerant boils, more of the liquid vaporizes More liquid present in the coil increases its efficiency No liquid refrigerant should leave the evaporator

LATENT HEAT IN THE EVAPORATOR Latent heat is more concentrated than sensible heat Latent heat transfers result in changes of state The greatest heat transfers take place during latent heat transfers 1.0 btu is required to change the temperature of one pound of water one degree Fahrenheit 970.3 btu are required to change one pound of water at 212 F to one pound of steam at 212 F

THE FLOODED EVAPORATOR Designed to operate full of liquid A latent heat transfer takes place throughout the coil Coil efficiency is maximized Other devices must be used to prevent liquid from entering the compressor Normally use a float-type metering device to keep the liquid level in the coil high

THE DRY-TYPE EVAPORATOR Evaporators are considered to be dry when all of the liquid boils before leaving the coil Evaporator superheat must be calculated Superheat = Evaporator outlet temperature minus the Evaporator saturation temperature Normal evaporator superheat is between 8 and 12 F High superheat indicates an underfed evaporator

EVAPORATOR SUPERHEAT Defined as the evaporator outlet temperature minus the evaporator saturation temperature The sensible heat that is added to the refrigerant at the outlet of the evaporator after all of the liquid has boiled off into a vapor Low superheat = Overfed evaporator High superheat = Underfed (starved) evaporator

CALCULATING SUPERHEAT Refrigerant R-XYZ EVAPORATOR SUPERHEAT = 36 F 25 F = 11 F REFRIGERANT LEAVING THE COIL OUTLET TEMP = 36 F REFRIGERANT ENTERING THE COIL EVAPORATOR SATURATION TEMPERATURE = 25 F

HOT PULL DOWNS Excessively loaded evaporators Occurs when the box has warmed up considerably System is not operating under design conditions Evaporator superheat may be high Evaporator superheat correct near design conditions System should stabilize before measuring superheat An overfed, dry-type evaporator with no superheat is said to be flooded

PRESSURE DROP IN THE EVAPORATOR The pressure drop through the coil should be as low as possible When the pressure drop is high, a multiple circuit evaporator is used Each circuit should be fed with the same amount of refrigerant (also liquid/vapor percentages) Reasons for uneven feeding include blocked distributors, dirty coil, uneven air distribution and different length coil circuits

LIQUID-COOLING EVAPORATORS Commonly called chillers or chiller barrels Different type of evaporator is used Dry-type, multi-circuit coils Usually operate with 8 F to 12 F of superheat Liquid-side problems include Mineral deposits Poor liquid circulation

EVAPORATORS FOR LOW- TEMPERATURE APPLICATIONS Evaporators are designed differently Fins are spaced far apart to accommodate frost buildup without sacrificing system operation or airflow through the coil Have some means to periodically remove frost Hot gas defrost sends compressor discharge gas to the evaporator coil to melt the ice Electric heaters can also be used

HOT GAS DEFROST Compressor discharge gas pumped directly to the evaporator coil during the defrost cycle Defrost is controlled by a solenoid valve Hot gas from the compressor condenses to a liquid in the evaporator coil Liquid from the evaporator vaporizes in the accumulator before returning to the compressor During defrost, the compressor operates with an increased load, increasing the amperage draw

ELECTRIC DEFROST Electric heating elements are located next to the evaporator coil The compressor and evaporator fan motor are not operating during defrost Fan motor operation would circulate hot air throughout the box during defrost At the end of the defrost cycle, the compressor cycles on before the fan to allow the evaporator coil to get cold before the fan is energized

UNIT SUMMARY - 1 Refrigeration is the process of transferring heat from a place where it is not wanted to a place where it makes little or no difference Heat flows naturally from warmer substances to cooler substances Common refrigeration temperature ranges are high, medium and low The evaporator is responsible for absorbing heat into the refrigeration system

UNIT SUMMARY - 2 The evaporator is maintained at a temperature that is lower than the medium being cooled The evaporator absorbs sensible and latent heat Sensible heat lowers the temperature in the box Latent heat lowers the humidity in the box Boiling temperatures and pressures are related by the pressure/temperature relationship Boiling temperature determines the coil temperature

UNIT SUMMARY - 3 Evaporators are commonly constructed of copper, steel, aluminum, stainless steel and brass Large temperature differences between the coil and the box result in a higher heat transfer rate Common evaporator types include the natural draft, forced draft and stamped plate Fins are used to increase the heat transfer surface Evaporators can be dry-type or flooded

UNIT SUMMARY - 4 Evaporator superheat is the evaporator outlet temp. minus the evaporator saturation temp. High superheat = Underfed evaporator Low superheat = Overfed evaporator Multi-circuit evaporators reduce the pressure drop through the coil Evaporators used for liquid cooling are chillers Low temperature evaporators are defrosted by hot gas or electric strip heaters