Galvanic Parts Per Million Dissolved Oxygen Systems



Similar documents
Interface Level And Point Level Analyzers & Sensors

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

DissolvedOxygenMonitor

USB-500/600 Series Low-Cost Data Loggers and Accessories

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Milwaukee USER MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Sanitary Type Electronic Flow Switches

USB-500 Series Low-Cost Data Loggers and Accessories

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Electronic Flow Switches

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

O C M III. Open Channel Flow Monitor

General Purpose ph/orp Sensors

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

USB-500 Series Stand-Alone, Low-Cost Data Loggers

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

USB-500/600 Series Low-Cost Data Loggers and Accessories

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

In-Line Electronic Flow Switches

DISSOLVED OXYGEN PROBE

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

PortaSens ll G AS DETECTOR

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

For Multi-Parameter Meters see mvx

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

TMS TANK MANAGEMENT SYSTEM

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Centro-Matic Automatic Lubrication Systems System Controls

WIRELESS INSTRUMENTATION TECHNOLOGY

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

How To Use A Ds340 (Dsp)

Current Monitoring Kit QUICK START GUIDE

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Current Monitoring Kit

Temperature & Humidity SMS Alert Controller

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

OxyGuard. Dissolved Oxygen Probe

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

PART 1 - INTRODUCTION...

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

PRODUCT PROFILE FEATURES

Why a torque measuring system?

Multifunction HVAC and IAQ Meter

MSFET MICROSENS Miniature ph Sensor Module

Regards from the Team at Rheology Solutions.

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Temperature & Humidity SMS Alert Controller

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Thermal Mass Flow Meter (Series MST)

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Electronic Control Devices The European Product Catalogue 2007

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Web-Based Remote Monitoring & Datalogging

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

PIEZOMETER AIRFLOW MEASURING RING

5000V Graphical Megohmmeter Model 5070

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Flow Monitoring System

Remote Monitoring and REC 501 Control Unit Product Guide

Magnum Mobile Generator MMG55 Specifications

PowerGem Pro Uninterruptible Power Supply

Fire Pump Controllers Remote Alarm Panels

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

C ole s quality Open Frame Instrument Rotary Switch provides low

Trace Dissolved Oxygen Sensor

TC 1818a. Operating Guide. Control Module SWM-015.5

The multi-functional integrator Supercal 531

API Marine. BMS Presentation. Ballast Measurement Systems

SMART SENSOR COLLECTION

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Digital inductive conductivity transmitter

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

In-Line Electronic Flow Switches

Multi-Function Ground

Multifunction devices

Portable Waterproof ph/dissolved Oxygen Meter

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Transcription:

Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in the world. like microprocessor-based intelligent electronics, with a choice of rugged, patented self-cleaning sensors, or maintenance free disposable cartridge sensors, make the totally waterproof Royce line of portable PPM DO analyzers the best available - anywhere. The MODEL 900 Portable offers features like single button calibration, self diagnostics, analog and digital communications outputs and many more features never before considered in a portable analyzer. Built for the rugged, wet environment of the conservationist, aquaculturist, and industrial operator - the Model 900 is setting a new standard for portable electronic analysis. Ideal for continuous DO monitoring where economy is a primary criteria, The Model 9100 is priced to offer a user friendly, reliable analyzer that fits any budget. Although the price is low, and its operation is simple, the Model 9100 is of the quality that DO monitoring customers have come to expect from Royce Technologies. This economic system, which uses the field proven Model 95A or Model 99 DO sensors, offers standard features such as sensor / analyzer self diagnostics, a readout in PPM or % saturation, and programmable setpoint relays - all included in the lowest priced rugged DO analyzer available. The Model 9200 Continuous DO analyzer provides the ultimate level of monitoring accuracy and aeration control available anywhere in the world. The analyzer is provided standard with everything available on the Model 9100. It also offers menu directing setup and trend graphing on the display, simultaneous DO and temperature readout on the display, standard automatic sensor membrane self-cleaning, digital AND analog outputs, a sensor output voltage mode, and four programmable setpoint relays. Used with the Model 96A DO sensor, the Model 9200 has become the benchmark analyzer for the DO monitoring & blower control market in the 21st century. The Model 9300 Sensor Buoy System is designed for large pond or lagoon aeration systems where dissolved oxygen monitoring and control is required but the sensor cannot be readily reached for maintenance. With features like programmable totally hands free automatic recalibration and long-term sensor self-cleaning, normal maintenance time for this system is around one year. There are almost 3000 of these systems in use around the world. Both the Model 9100/95A & Model 9200/96A systems, completed the 2002 Instrument Testing Association s (ITA) comparative DO test with outstanding results. Test results are available. Contact Royce Technologies for more information. Bulletin No. PPM-10 December 2005

Model 9100 Single-Channel Dissolved Oxygen: Ranges, 0-99.9 mg/l (PPM) 0-100% Saturation Resolution, 0.01 mg/l 1% Saturation Accuracy, ± 0.1 mg/l or 1% Saturation Temperature - Selectable: 0-50 O C x.1 O C or 23-122 O F x 1 O F Accuracy, ± 0.2 O C Compensation, +/- 1% of reading Stability:.1mg/l Input Power: Switch selectable 115/230 VAC, 50/60 Hz Readout Device: Harsh environment, one-half inch LCD digital display Model 9200 Single-Channel Dissolved Oxygen: Ranges, 0-99.9 mg/l (PPM) 0-100% Saturation Resolution, 0.01 mg/l 1% Saturation Accuracy, ± 0.1 mg/l or 1% Saturation Temperature - Selectable: 0-50 O C x.1 O C or 23-122 O F x 1 O F Accuracy, +/- 0.2 O C Compensation, ± 1% of reading Stability:.1mg/l Input Power: Switch selectable 115/230 VAC, 50/60 Hz Readout Device: Harsh environment, 2.5 x 4.5 graphical LCD digital display Specifications Specifications 2 Microprocessor based electronics Range 0-99.9 PPM and % Saturation 0-99.9% Readings to 1/100 PPM up to 10 PPM One step, push button calibration Two methods of calibration are standard Automatic temperature, Altitude, salinity compensation Electronic self-diagnostics Isolated 4-20 ma or 0-20 ma Digital serial output available 2 programmable relays Outputs: One Isolated Analog Output for Temperature One Isolated Analog Output for DO Either: Isolated 4-20 ma or 0-20 ma driving 600 ohms Max. or one RS-485 digital, isolated 2 Standard setpoint relays with programmable hysteresis Form C rated 250 VAC at 6 Amps resistive Calibration: Automatic, one step push button calibrates for DO, altitude, salinity Enclosure: NEMA 4X (IP65) Weight: 6 lbs., 2.75 kgm Mounting Information on Page 8 Microprocessor based electronics Range 0-99.9 PPM and % Saturation 0-99.9% Simple calibration with help screen prompts Automatic temperature, Altitude, salinity compensation Individual DO and temperature outputs 4 programmable relays One step, push button calibration Electronic self diagnostics for sensor and analyzer Electrochemical self cleaning sensor - Standard Standard 24 hour trend graph Backlight display Outputs: One Isolated 4-20 ma Output for DO One Isolated 4-20 ma Output for Temperature One RS-485 digital, isolated 4 Standard setpoint relays with programmable hysteresis All relays are Form C rated 250 VAC at 6 Amps resistive Display: DO, temperature, relay status, trend graph and programming menus Calibration: Automatic, one step push button calibrates for DO, altitude, salinity Enclosure: NEMA 4X (IP65) Weight: 8.7 lbs., 3.95 kgm Mounting Information on Page 8

Model 9300 Sensor Buoy System Maintenance Free Dissolved Oxygen Control System Sensor cleaned automatically for up to 12 months Sensor automatically calibrated daily Automatic control of aerators, alarms and other devices - Up to four outputs A backlit display provides both DO and temperature readings Over 8 years of research in the field led to the development of the Royce Sensor Buoy System. Originally designed for large wastewater and fish growing lagoons where DO sensing devices could not be easily reached for maintenance. In use since 1992, there are now over 3000 of these systems operating throughout the world. The system is made up of the Model 9300 Buoy Control Monitor and the Sensing Buoy that incorporates the proven Royce Model 95A galvanic DO sensor. Automatic sensor cleaning is a chemical process that occurs once every 12 minutes, all controlled from the Model 9300 Buoy Rail Mounting Self-diagnosing electronics with automatic built in buoy test protocols 16 - day data logging Sensing buoy utilizes only 2 moving parts which are completely sealed Buoy utilizes a unique guard system against the intake of solids Controller, which is mounted on the lagoon or aeration basin handrail. Automatic sensor recalibration occurs once per day, at a time that is programmed into the controller by the user. The System s Sensing Buoy is made from rugged schedule 80 PVC and can be either floated away from a lagoon bank or hard mounted from the handrails of an aeration basin. The only moving parts inside the buoy are two small DC powered pumps that move water through a unique polymer manifold during the sampling and calibration processes. Service of the buoy system is minimal, usually required only once per year. Probe Mounting varies by configuration consult Factory 3

Model 900 Portable PPM Dissolved Oxygen System Reads in PPM DO, temperature, % saturation Rugged enclosure and sensor Two choices of sensors Accessories for various field and lab applications The Royce Model 900 Portable Dissolved Oxygen (DO) Measuring System is a rugged waterproof instrument designed for the rigors of remote sampling. The system includes a choice of two rugged sensors - the Model 95A rechargeable sensor or the Model 99 disposable cartridge sensor Dissolved Oxygen Autoranging: Ranges, 0.00-99.9 mg/l (PPM) x 0.01 PPM to 10.0 to 99.9 mg/l (PPM) x 0.1 PPM or 1-100% Saturation x 1% Sat. Temperature - Selectable: 0-50 O C x.1 O C or 23-122 O F x 1 O F Accuracy, ± 0.2 O C Compensation, ± 1% of reading Display: Harsh environment, 1/2 LCD digital display Stability:.1mg/l Model 900 rugged DO/Temperature analyzer Sensor of choice will have a 15 cable and waterproof military connector Membrane Protection Cap Flexible sensor storage cap Waterproof cap for output connector Nylon grip strap which converts to a handy belt holder Flexible zippered waterproof nylon carry bag with webbed nylon handle, separate protective pocket for manual, Part #59381 Model 95 Sensor adaptor for 2 T flow cell mounting, Part #59377 Model 95 Sensor collar adaptor kit for ground water monitoring insertion assemblies, Part #59378 Model 95 Epoxy flow cell with 1/4 stainless steel connections, Part #54532 Output cable assembly with waterproof connector, Part #59396 Model 900 Specific necessary. Model 900 System Specifications Supplied Standard with Model 900 Systems, with Model 95 Sensor, Part #59748 with Model 99 Sensor, Part #58132 Utilizing full microprocessor controlled electronics, the Model 900 is quickly programmed by the user for conditions (salinity, partial pressure, etc.) specific to his application. From that time on - all functions are single button action. Recalibration of the sensor is a single keystroke of the instrument and should not be required more than once per week. A complete recharge of the Model 95A sensor is no more than a 5 minute operation and should not be required sooner than every 3 to 6 months - if the system is used properly. The Model 99 disposable sensor cartridge should last at least 1 year before replacement is Repeatability: ± 1% (at constant temperature) Sensor Response Time: 99% of actual in less than 30 seconds Sample Flow Requirements: Less than.4 ft/sec with 1 mil membrane Outputs: 0-1 VDC, adjustable RS-232 Serial digital interface Weight: 3.4 lbs., 1.55 kgm Optional Accessories and Equipment 4 One dozen 1 mil Teflon* membranes in a hard storage case (95A sensor only) 16 ounces of potassium chloride electrolyte (95A sensor only) 9V battery Detailed Instruction manual 24-2 mil Teflon* membranes for Model 95A sensor, Part #59252 24-1 mil Teflon* membranes for Model 95A sensor Part #59251 Model 99 replaceable cartridge, 1 mil membrane, Part #59842 Model 99 replaceable cartridge, 2 mil membrane, Part #59843

Series 90 DO Sensors Rugged noncorrosive construction Platinum cathode, lead anode Automatic temperature compensating Can be easily rebuilt in the field No special tools required Simple positive membrane replacement Patented electrochemical self-cleaning available (Model 96A only) Jet-cleaning available Specifications Measuring Principal: Galvanic Cathode Material: Platinum Anode Material: Coiled Pure Lead Electrolyte: Potassium Chloride gel Repeatability: ± 1% (at constant temperature) Response Time: Using 1 mil membrane - PPM 99% of actual, from air calibration < 30 seconds Temperature Accuracy: ±.2 O C Sample Flow Requirements: 0.4 feet per second with 1 mil membrane The Royce Models 95A and 96A Sensors are the latest sensor developments in the field of continuous DO monitoring and control. The small silhouette, and rugged construction of the Models 95A/96A create a unique sensor for the rough applications found in the wastewater treatment, ground water, aquaculture, and oceanographic industries, Both sensors contain precision internal circuitry and use the proven galvanic method of measurement. The Model 96A Sensor is unique in that it incorporates a dual cathode, dual anode system which gives it the ability to perform the Royce patented electrochemical self cleaning function when used in conjunction with the Model 9200. The response time and stability of this sensor are so good that it is the very same DO sensor used with the Royce Parts Per Billion DO Measuring Systems (Bulletin #PPB). This rapid response time capability makes the Model 96A the DO Sensor of choice for oceanographic profiling applications. The Model 95A is a rugged rechargeable sensor that comes supplied with membranes and KCL gel 5 solution with a system purchase that should last for five years with normal use. The Model 99 offers the convenience of a maintenance-free disposable sensor cartridge. The Model 95A and 99A Sensors were specifically developed for the Model 9100 continuous monitoring analyzer and the Model 900 portable. The sensors incorporate all of the features of the Model 96A except they do not have the dual cathode, dual anode configuration to accommodate electrochemical self-cleaning. The trim, reliable mounting bracket assembly employed with the Royce line of Series 90 DO Sensors is simple to install and allows for easy access to the sensor for quick maintenance. A narrow profile sensor/collar arrangement allows for a standard PVC pipe installation from any standard rail. This configuration dramatically reduces the potential of rag fouling. For those users that feel that the floating ball sensors provide an adequate monitoring platform, the Royce Model 95A and 99A Sensors will easily adapt to that configuration.

Model 99 Replaceable Cartridge DO Sensor Sensor Mounting Model 99 Cartridge Dissolved Oxygen Sensor Economical initial price Rugged Noncorrosive construction Long lived cartridge Galvanic in operation Temperature compensated 1 or 2 mil membranes available Jet-cleaning available The Model 99 replaceable Dissolved Oxygen Cartridge was specifically designed to answer the needs of plants that did not want to recharge sensors. It utilizes the same proven technology and basic design criteria found in all the Royce sensors. Rugged, easy to use, quick changing and with all the accuracy and reliability users have come to trust in Royce Technologies. Sensor Specifications Cathode Type and Material: Galvanic - Platinum Anode Material: Coiled lead wire Electrolyte: Potassium Chloride gel Repeatability: ± 1% (at constant temperature) Response Time: Using 1 mil membrane - PPM 99% of actual, from air calibration in 60 seconds Spares 1 Mil Sensor Cartridge - #59842 2 Mil Sensor Cartridge - #59843 Backshell with 25 Cable - #54730 6 Temperature Accuracy: ±.2 O C Sample Flow Requirements: 0.4 feet per second with 1 mil membrane Dimensions: 1.2 Dia. x 5.8 long Weight: (w/25 cable).5 lbs., 22 kgm

Jet Clean Sensor Membrane Cleaning System The Royce Jet-Clean sensor Cleaning System is designed for the purpose of cleaning the DO membrane which may be soiled by organic, inorganic, or biological debris. The system can be configured in two ways, (1) for plants with house air or water (minimum pressure must be 30 psi), a simple solenoid can be used to supply a periodic high pressure wash stream across the electrode measuring surface; or (2) a miniature industrial, rail mounted, compressor system can be supplied that will periodically supply 65 psi of air across the membrane surface. No mater which method of cleaning is used all Royce DO analyzers are programmed to allow the user to adjust their preferred cleaning cycle time. The DO sensor is mounted in a molded epoxy jet head which is contoured in order not to collect rags or other debris. Jet Head Sensor Assembly Compressor Specifications Type: Air Compressor, Light, Noncontinuous duty Pressure supplied: 40 to 60 PSIG Temperature Limits: 0 to 50 O C Enclosure: NEMA 4X, 14 W x 12 H x 6 D Input Power: 115/230 VAC, 60/50 Hz Weight: 23 pounds (10,4 kgms) 26 pounds (11.8 kgms) with rail kit Options: Heater (Recommended for -10 O C) Rail Mounting Kit Compressor Outline & Mounting Additional and Options ROYCE Electrochemical Sensor Cleaning A unique Royce patent used for the automatic self cleaning of the DO sensor membrane. On a timed basis, programmed into the Model 9200 analyzer by the operator, the sensor membrane, discouraging growth on the membrane. This process will allow for up to six months, depending upon the sensor s environment, of maintenance free operation. This is a standard feature of the Model 9200 analyzer. The Model 96A sensor is required. Sensor Mounting Model RDC-92 Remote Display Junction Box The Model RDC-92 is a NEMA 4X fiberglass junction box that is mounted on the rail at the same location as the DO sensor when the Model 9200 is to be mounted away from the sensor. The RDC-92 incorporates a 1/2 inch harsh environment LCD digital display for visual monitoring and an air calibration button so calibration can be performed away from the parent analyzer. Power for the junction box is supplied by the parent instrument. Temperature limitation for the junction box is -40 to 85 O C. Time Delay Control In applications where the simple set point relay method of aeration control is inappropriate, the Model 9200 analyzer relays may be programmed to pulse at predetermined intervals when setpoints are exceeded. This is often used with positional control systems for weirs, gates, etc. It is a standard feature on the Model 9200 analyzer. 7

Dimensions Model 9100 Mounting Information Rail Mounting Dimensions Model 9200 Mounting Information Rail Mounting 14125 So. Bridge Circle Charlotte, NC 28273 800/347-3505 704/409-9898 FAX: 704/409-9899 - royce@itt.com Web Site: http://www.roycetechnologies.com