Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial



Similar documents
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Data Center Design Considerations

TIA-942 Data Centre Standards Overview WHITE PAPER

Network Topologies and Distances

How To Write An Infrastructural Standard For Data Center Infrastructure

Data Centre Issues supported in TIA-942 : "Telecommunications Infrastructure for Data Centre s"

TIA-942: Data Center Standards

TIA STANDARD. Telecommunications Infrastructure Standard for Data Centers TIA-942 TELECOMMUNICATIONS INDUSTRY ASSOCIATION

Corning Cable Systems Optical Cabling Solutions for Brocade

Data Center Topology Guide

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Zone Distribution in the Data Center

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Data Centre Design ready for your future

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Data Center Cabling Design Trends

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Data Center Design for 40/100G

Network Design. Yiannos Mylonas

Video Systems and Data Center Design Wiring Plant Designation Terminology Infrastructure Deployment

AMP NETCONNECT Data Center Cabling Solutions

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

InstaPATCH Cu Cabling Solutions for Data Centers

CommScope. Enterprise Data Center Design Guide.

Keyword: TIA 942, Tier level, Nuclear Data Center. Introduction

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Corning Cable Systems Optical Cabling Solutions for Brocade

DESIGN GUIDELINES. Local Area Network

This presentation to be used in conjunction with:

The Three Principles of Data Center Infrastructure Design WHITE PAPER

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

BICSI NxtGEN & Global Data Center Standards Update

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Structured and Point to Point Network Cabling for Industrial Automation

Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Minimum Standards for Data/Voice Infrastructure in New Building Construction

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

Building a Tier 4 Data Center on a Tier 1 Budget

Giganet Copper Cabling Training

Designing the Data Center

Data Center Designs and Hospital Operations

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Building Telecommunications Infrastructure Requirements

What is a Datacenter?

How To Determine Data Center Reliability

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

Organizing and Managing Equipment Rooms

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Cabling and Building Infrastructure for Technology

SECTION TELECOMMUNICATION ROOMS

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Documenting and Managing Infrastructure Connectivity

40GBASE-T Advantages and Use Cases

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

Obsolete Fiber Technology? Not in my Data Center!

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Engineers Edge, LLC PDH & Professional Training

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Specifying an IT Cabling System

Specifications for Communication Cabling Distribution Systems

Arista and Leviton Technology in the Data Center

INTRODUCTION TO MEDIA CONVERSION

Gigabit Passive Optical Networks

Opportunities in data centers for the ITS professional

Considerations for choosing top-of-rack in today's fat-tree switch fabric configurations

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

Data Center Solutions

Data Center Network Infrastructure The Smart Choice For Your Data Center

ADC-APC Integrated Cisco Data Center Solutions

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

DEPARTMENTAL REGULATION

UT Southwestern Medical Center Information Resources Cable Installation Standard

SYSTIMAX Solutions Data Center Planning Guide

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

DATA CENTER CABLING DESIGN FUNDAMENTALS

ABOUT ANIXTER UNIVERSITY

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)

T1 Backhaul Connectivity Solution All Products :: Application Note

The Need for Low-Loss Multifiber Connectivity

Policy Title-Aquia Data Center Operational Policy & Procedure. Policy ID - TSD-ADC001. Version - Version: 1.0. Supersedes Version 1.

Data Center Solutions

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Transcription:

Telecommunications Infrastructure Standard for Data Centers 802.3 Tutorial Prepared by: Jonathan Jew - J&M Consultants and Chris DiMinico - MC Communications - Co-chairs TR42.1.1

TR42: Data Center Standard PN-3-0092 Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003

Telecommunication Infrastructure Enterprise Customer Premise ISP Internet Data Center Local Loop -service provided Service provider - Distribution Node -Central Office Service Provider Backbone Customer lease Service provider - Distribution Node -Central Office Local Loop -service provided Enterprise Customer Premise ISP Internet Data Center Home SOHO DATA/Voice Infrastructure Data Center EFM- Access Networks Home SOHO

Campus Network: California State University Data Center -80 s

Cornell Campus Network, -87

Internet Data Centers Network infrastructure required to drive web hosted Internet applications.

Service Provider Distribution Node- Central Office

Ethernet Networking -LAN/WAN/SAN Remote Enterprise 10 Gb/s DWDM Infrastructure WAN 10 Gb/s Internet WAN Router Equipment Room Switch 10 Gb/s Firewall 1 Gb/s 100 Mb/s LAN 10 Mb/s 1 Gb/s File Servers SAN Web Servers Email Servers Backbone Switch / Router Application Servers 1 Gb/s 10 Gb/s 10 Gb/s -Internet Data Center -Computer Room

Cabling Topologies and Distances Cable Element Horizontal Cabling Equipment-to- Equipment Customer Premises ISO/IEC 11801-TIA Data Center Central Office Equipment Room 100 meters 100 meters 100 meters NA 100 meters 100 meters 30 meter

Who is Developing the Standard The standard is being developed by the TIA/TR42 Engineering Committee - subcommittee-tr-42.1.1 Network Distribution Nodes - Project No. 3-0092 Participants include: Architecture & Engineering Firms Consultants End Users Manufacturers The standard will become TIA-942 To be submitted for approval by ANSI and CSA

Status of the Standard 2 nd draft released for industry ballot July 2003. Draft posted to IEEE website Ballot comments to be resolved October 2003. Liaison with other standards organizations (IEEE, CENELEC, BICSI, ISO,ASHRE) Liaison with data center industry organizations (7X24 Exchange,Uptime Institute) Liaison with network and computer equipment manufacturers Final approval expected sometime in 2004

Purpose of the Standard Enabling planning for data centers to occur earlier in the building development process (architectural, facilities, and IT). Fill a void by providing standards for planning of data centers, computer rooms, server rooms, and similar spaces. The standard encompasses much more than just telecommunications infrastructure. Close to half of the technical content deals with facility specifications.

Purpose of the standard Specifications for data center telecommunications cabling, pathways and spaces Recommendations on media and distance and restrictions for data center applications over structured cabling system (TIA 232, TIA 561, T1, E1, T3, E3, 1 & 10 Gigabit Ethernet, Fibre Channel) Establish a standard for data center tiers to replace several proprietary standards. The TIA data center tier standard is: A tool to evaluate existing data centers A tool to communicate design requirements

TR42.1 Study Group: Telecommunications Cabling Infrastructure for Network Distribution Nodes Scope: Develop cabling topology, recognized media types, cabling requirements, and requirements for pathways & spaces for data centers Cabling Design Network Design Facility Design Informative annex: Provide best practices

Design Elements: Cabling Design: Copper and fiber cabling performance Connectors, cables, distribution hardware Cabling distances Space management Facility Design: Data center sizing Power distribution methodologies Pathways and spaces HVAC, security, operations, and administration. Flexibility, scalability, reliability and space management

Design Elements: Network Design: Support legacy systems Enable rapid deployment of new technologies such as the emerging 10 Gb/s applications.

Overview of key elements - Normative Normative: Clause 5. cabling spaces - definitions Clause 6. Data center cabling definitions topology recognized media redundancy Clause 7. Data Center Cabling Pathways

Overview of key elements - Informative Informative: Clause 8: Redundancy Annex: application distances administration carrier information site selection infrastructure tiering design examples

Distribution Areas - Spaces for cabling elements Cabling elements Cross-connect Interconnect Distribution Areas Main Distribution Area -MDA Horizontal Distribution Area -HDA Zone Distribution Area - ZDA Equipment Distribution Area -EDA Entrance Room

Purpose of the standard Define a standard telecommunications infrastructure for data centers Structured cabling system for data centers using standardized architecture and media Accommodates a wide range of applications (LAN, WAN, SAN, channels, consoles) Accommodates current and known future protocols (10 Gigabit Ethernet) Replaces unstructured point-to-point cabling that uses different cabling for different applications

Relationship of Spaces BUILDING SITE BUILDING SHELL GENERAL OFFICE SPACE TELECOM ROOMS & EQUIPMENT ROOMS for spaces outside data center OFFICE BUILDING SUPPORT SPACE DATA CENTER SUPPORT STAFF OFFICES ENTRANCE ROOM(S) DATA CENTER ELECTRICAL & MECHANICAL ROOMS OPERATIONS CENTER TELECOM ROOM(S) for data center support spaces STORAGE ROOMS & LOADING DOCKS COMPUTER ROOM

Data Center Telecommunications Spaces Offices, Operations Center, Support Rooms Telecom Room (Office & Operations Center LAN switches) Horiz Dist Area (LAN/SAN/KVM Switches ) Zone Dist Area Carriers Horiz Dist Area (LAN/SAN/KVM Switches ) Entrance Room (Carrier Equip & Demarcation) Main Dist Area (Routers, Backbone LAN/SAN Switches, PBX, M13 Muxes) Carriers Computer Room Optional Backbone Cabling Horiz Dist Area (LAN/SAN/KVM Switches ) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet)

TIA-942 Spaces Entrance Room (ER) - location of interface with campus and carrier entrance facilities Main Distribution Area (MDA) location of main cross-connect (MC) Horizontal Distribution Area (HDA) location of horizontal cross-connect (HC) Zone Distribution Area (ZDA) location of zone outlet (ZO) or consolidation point (CP) Equipment Distribution Area (EDA) location of equipment cabinets and racks

Data Center Cabling Topology Offices, Operations Center, Support Rooms Carriers Horizontal cabling Telecom Room (Office & Operations Center LAN switches) Backbone cabling Entrance Room (Carrier Equip & Demarcation) Backbone cabling Main Dist Area (Routers, Backbone LAN/SAN Switches, PBX, M13 Muxes) Carriers Computer Room Horiz Dist Area (LAN/SAN/KVM Switches ) Backbone cabling Zone Dist Area Horizontal cabling Horiz Dist Area (LAN/SAN/KVM Switches ) Horiz Dist Area (LAN/SAN/KVM Switches ) Horizontal cabling Horizontal cabling Horizontal cabling Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet)

Distributed Topology with Multiple ERs Offices, Operations Center, Support Rooms Carriers Primary Entrance Room (Carrier Equip & Demarcation) Carriers Carriers Carriers Horizontal cabling Backbone cabling Telecom Room (Office & Operations Center LAN switches) Backbone cabling Main Dist Area (Routers, Backbone LAN/SAN Switches, PBX, M13 Muxes) Backbone cabling Secondary Entrance Room (Carrier Equip & Demarcation) Horiz Dist Area (LAN/SAN/KVM Switches ) Backbone cabling Backbone cabling Computer Room Zone Dist Area Horiz Dist Area (LAN/SAN/KVM Switches ) Backbone cabling Backbone cabling Backbone cabling Backbone cabling Horizontal cabling Horiz Dist Area (LAN/SAN/KVM Switches ) Horiz Dist Area (LAN/SAN/KVM Switches ) Horizontal cabling Horizontal cabling Horizontal cabling Horizontal cabling Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet)

Backbone Topology Includes cabling from MDA to ER, HDA, TR Optional cabling between HDAs allowed Maximum backbone cable lengths based on applications distances Centralized optical fiber cabling supported with interconnect, splice, or pull-through at the HDA Star topology with no intermediate cross-connects Various topologies permit redundancy and flexibility to support various data center sizes

Horizontal Topology Defined as cabling from horizontal cross- connect (HC) to the equipment distribution area (EDA) Star topology with termination on HC in HDA or MDA Max of one consolidation point in a ZDA

Horizontal and Backbone Cabling Recognized Cables: a) 100-ohm twisted-pair cable (ANSI/TIA/EIA- 568-B.2), category 6 recommended (ANSI/TIA/EIA-568-B.2-1) b) multimode optical fiber cable, 50/125 micron (ANSI/TIA/EIA-568-B.3) and 62.5/125 micron or 50/125 micron (ANSI/TIA/EIA-568-B.3) c) singlemode optical fiber cable (ANSI/TIA/EIA- 568-B.3) d) 75-ohm (734 and 735 type) coaxial cable (Telcordia Technologies GR-139-CORE)

Carrier Circuit Lengths in Data Centers Maximum cable lengths for common circuits: E-1 s s over 24 AWG Cat 5/5e/6 UTP: 532 ft (152 m) - 16.4 ft (5 m) per patch panel T-1 s s over 24 AWG Cat 5/5e/6 UTP: 731 ft (223 m) - 16.4 ft (5 m) per patch panel E-3 s over 734 coax: 618 ft (188m) 19.8 ft (6 m) per patch panel T-3 s over 734 coax: 513 ft (156m) 15.4 ft (4.7 m) per patch panel Distances are from carrier demarcation point to end equipment and assume no customer DSX.

Carrier Circuit Lengths in Data Centers Common data center configurations include 6 patch panels: 1 in ER, 2 in MDA, 2 in HDA, and 1 in the EDA Cat 3 instead of Cat 5 reduces circuit lengths for T-1s and E-1s significantly 735 coax (mini-coax) reduces circuit lengths for T-3s, E-1s, and E-3s significantly Circuit length restrictions may : require additional ERs, limit location of telecom equipment, limit the size of the computer room

Computer Room Requirements Similar to Equipment Room reqts from TIA-569 Min clear height of 2.6m/8.5 ft Min door size 1m/3ft wide 2.13/7ft high Min dist floor loading 7.2 kpa/150lbf/ft 2, recommended min 12 kpa/250 lbf/ft 2 Dedicated HVAC system preferred 20 o C to 25 o C 40% to 55% relative humidity (reduces ESD) Signal reference grid equipotential ground reference and reduces stray high frequency signals Any sprinkler systems must be pre-action system

Entrance Room Demarcation to carriers Telecom Entrance & Campus Conduits Carrier Racks Coordinate power and space requirements with each carrier Provide either AC or DC power to carriers. If ER only has AC power, carriers install DC power from rectifiers to their racks & cabinets Plywood for protectors Not required if no copper entrance cables or if carrier will install protectors on frames or racks

Entrance Room ER may be inside data center but, location outside data center provides best security ER may be consolidated with MDA ER requires the same redundancy for power and cooling as the computer room space Locate ER to avoid exceeding maximum cable lengths for circuits Cabling distances for carrier circuits may dictate multiple ERs in large data centers

Main Distribution Area Location of Main Cross-Connect (MC), the central point of distribution for data center structured cabling system Centrally located to avoid exceeding maximum distance restrictions (typically for E-1s, E-3s, T-1s and T-3s) Install separate racks for Fiber, UTP, and coaxial cable distribution

Main Distribution Area Data center size may dictate use of Cat 5e or 6 UTP for Fractional T-1, E-1, T-1, ISDN PRI Copper-pair cabling for LAN backbone cabling (in smaller data centers) and out-of-band management using Cat 5e or 6 UTP AT&T 734-type 75 ohm coaxial cable for E-1, E-3, T-3 cabling (two coax per circuit) Multimode and Single-mode fiber cabling for OC- 3, OC-12, OC-48, MAN, LAN & SAN backbone.

Horizontal Distribution Area Location of Horizontal Cross-Connect (HC), the distribution point for cabling to equipment distribution area Distribution LAN, SAN, KVM switches and console servers located in HDA MDA may also include an HC for nearby equipment distribution area Number of HDAs depends on the density of cabling and the size of the data center

Horizontal Distribution Area The capacity of the cable tray system and the size of the cross-connect creates practical limits on the size of the HC Guideline is maximum of 2,000 4-pair UTP or coax cable terminations per HDA Arrange patch bays to minimize patch cable lengths and to simplify cable management Separate racks for fiber, UTP, and coax Locate switches and patch panels to minimize patch cord lengths

Zone Distribution Area Rack, cabinet, or under floor enclosure that houses a zone outlet (ZO) or consolidation point (CP) ZO - structured cabling termination for floor- standing equipment that cannot accept patch panels (e.g. mainframes and large servers). CP - intermediate termination point (e.g. cabling to areas where floor plan is uncertain or dynamic) No cross-connects within the ZDA No active equipment shall be located in the ZDA Maximum of 144 connections in a ZDA Maximum of one ZDA within a horizontal cable run

Equipment Racks & Cabinets Cabinets and racks should be arranged in an alternating pattern (with fronts of rows of cabinets/racks facing each other) to create hot and cold aisles Cold aisles are front of racks/cabinets if there is a raised floor, PDU cables are run here on the slab. Hot aisles are rear of racks/cabinets cable trays for telecom cabling are typically placed here. Perforated tiles should be placed in cold aisles.

HOT AND COLD EQUIPMENT AISLES REAR FRONT FRONT REAR REAR FRONT CABINETS CABINETS CABINETS PREFORATED TILES PREFORATED TILES TELECOM CABLE TRAYS POWER CABLES TELECOM CABLE TRAYS POWER CABLES

Equipment Racks & Cabinets Equipment is mounted in racks & cabinets from the front provide adequate clearance for installation of equipment (minimum of 3 feet, 4 feet is recommended). Cabinets should be aligned with one edge along the edge of the floor tile. Arrange cabinets and racks on raised floor to permit tiles along the front and rear of the cabinets to be lifted Floor tile cuts should be no larger than necessary to minimize air pressure loss.

Equipment Cabinets Front rails of cabinets must be recessed to provide adequate room for patch cables and wire managers Adequate space for cable management Arrange switches and patch panels to minimize patching between cabinets & racks Perforated tiles at front of cabinets One edge of cabinets placed at edge of tile

Raised Floor More flexible cooling with raised floor than ducted air Most stand-alone computer systems are designed for cabling from below Coordinate under floor cabling with mechanical & electrical engineers Recommend wire basket cable trays in hot aisles for telecom cabling

Example of Wire Basket Cable Trays For Cabling Under Raised Floor 24" RAISED FLOOR TILE 1.375" 9" 4" 5" FIBER DIVIDER 18" COPPER CABLING SUPPORT STRUT 1" 36" 12" 4" 5" FIBER 18" COPPER CABLING SUPPORT STRUT 1" Open Area 13.5" 24" On Center

Under Floor Space Example Color-coded PDU cables in hot aisles each cabinet fed from 2 PDUs Locking electrical receptacles NEMA L5-20R Signal Reference Grid (SRG) using bare copper conductor Each cabinet bonded to SRG

Overhead Cable Trays Less expensive than raised floor systems Cable trays can be attached to the top of racks and cabinets (if they are uniform in height) Cable trays suspended from the ceiling provides more flexibility for supporting cabinets/racks of various heights and for adding and removing cabinets/racks. Cable trays can be installed with several layers Coordinate location with lighting, ducts, overhead conduits, overhead power distribution

Overhead Cable Tray Example 3 Layer cable tray system: Bottom layer copper Middle layer fiber Top layer power Signal Reference Grid in brackets attached to lower layer of trays Fiber patch cables may be in fiber duct attached to threaded rods

Infrastructure Administration Informative annex with TIA-606-A standards compliant labeling scheme for all components. Labeling scheme extended for use in data centers Cabinets and racks labeled by location using tile grid or row/position identifiers All cabinets, racks, patch panels, cables, and patch cords should be labeled

Facilities Specifications & Tiers Informative annex with general architectural, structural, electrical, mechanical, and telecommunications recommendations requirements Annex includes detailed architectural, security, electrical, mechanical, and telecommunications recommendations for each Tier Recommended specifications by tier are a uniform way to rate aspects of a data center design and are a starting point for initiating design requirements with qualified architects and engineers

Redundant Topologies Carriers Carriers Carriers Carriers Primary Customer Maintenance Hole (Tier 1 and higher) Secondary Customer Maintenance Hole (Tier 2 and higher) Data Center Tier 1 Tier 3 Tier 2 Tier 3 Primary Entrance Room (Tier 1 and higher) Tier 3 Secondary Entrance Room (Tier 3 and higher) Offices, Operations Center, Support Rooms Tier 1 Tier 4 Tier 3 Tier 4 Telecom Room Main Dist Area (Tier 1 and higher) Tier 4 Secondary Dist Area (Optional for Tier 4) Computer Room Horiz Dist Area Optional Cabling Zone Dist Area Horiz Dist Area Horiz Dist Area Equip Dist Area Equip Dist Area Equip Dist Area

Conclusion TIA-942 is the first standard that specifically addresses data center infrastructure. Primarily a telecom infrastructure standard, but about half of the content deals with facility requirements. Provides a flexible and manageable structured cabling system using standard media. Builds on existing standards, where applicable Guidelines on a wide range of subjects useful to someone designing or managing a data center. An official tiering standard for determining the quality of a center. A way to objectively compare one center with another.