Cleanroom systems. HVAC systems for hospitals



Similar documents
SP/1/EN/5. Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air

Air-water systems for efficient air conditioning

Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7

Air management solutions at ceilings and facades

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Under sill units. Type FSL-B-ZAS

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Displacement ventilation

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Federation of European Heating, Ventilation and Air-conditioning Associations

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

Active & Passive Beams

Spetec. Laminar Flow Box. Portable Clean Room Technology

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

OSRAM LEDs take downlights into the future. LEDVANCE DOWNLIGHT and PARATHOM KIT LED PRO.

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

SPECIAL APPLICATIONS

Data Centres A complete solution to noise control and acoustic packages

plenum slot diffusers

STATISTICS FOR THE FURNITURE INDUSTRY AND TRADE

UDSA - UDSBD unit heater

Radiant Panels and Chilled Sails.

Global Effective Tax Rates

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

Accuracy counts! SENSORS WITH ANALOG OUTPUT

ACO ShowerDrain S-line Setting new standards for bathroom drainage

Behaviour Analysis & Certification in Europe: Developments & Opportunities

Hong Kong s Health Spending 1989 to 2033

Behaviour Analysis & Certification in Europe: Developments & Opportunities

Material test chamber with mechanical convection

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Element D Services Heating, Ventilating, and Air Conditioning

Brochure More information from

Decree of the Ministry of the Environment on fire safety of ventilation systems

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Appendix 1: Full Country Rankings

World Consumer Income and Expenditure Patterns

Comparison between Decentralised and Centralised Air Conditioning Systems

Report on Government Information Requests

Application Notes for VTech 1-Line and 2-Line Analog Hotel Phones with Avaya IP Office 8.1 and Voic Pro 8.1 Issue 1.0

DSRQ - DSRSQ - DSRSQ-THERM

MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO

BT Premium Event Call and Web Rate Card

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Basic Selection & Proper Application of Overhead Air Distribution Devices

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

THE WORLD S LEADING CAR DESIGN MAGAZINE

How To Make A Building Energy Efficient

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

- 5 - Table1. Maximum Compartment Volumes

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

ASTACEA4 Inspect complex/central air conditioning systems

Malta Companies in International Tax Structuring February 2015

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

The Role of Banks in Global Mergers and Acquisitions by James R. Barth, Triphon Phumiwasana, and Keven Yost *

Reporting practices for domestic and total debt securities

Fire Resistant Systems

We have been working in an ideal climate for thirty years.

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Supported Payment Methods

SECTION MORTUARY REFRIGERATORS

Supported Payment Methods

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Transformer oil cooler ALFA A02

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

CONTAMINATION CONTROL IN HOSPITALS. Isabelle Pautrel Ingénieur Clean Concept Patriarche & Co i.pautrel@patriarche.fr

Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Incubator with mechanical convection

HDA

Stylish Integration of Linear Diffusers With system solutions and installation details for architects and interior designers

AIR DISTRIBUTION FOR COMFORT AND IAQ

Triple-play subscriptions to rocket to 400 mil.

International Call Services

About us. As our customer you will be able to take advantage of the following benefits: One Provider. Flexible Billing. Our Portal.

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

IFI SPONSOR & PARTNER OPPORTUNITIES CELEBRATING 50 YEARS

Federation of European Heating, Ventilation and Air-conditioning Associations

Elements of Energy Efficiency in Data Centre Cooling Architecture

Pneumatic tube systems

Configuring DHCP for ShoreTel IP Phones

Final report November 2014 West hall Atrium Tokyo Big Sight, Japan

Acoustic Design Practices for Sustainable Buildings

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Image Lab Software for the GS-900 Densitometer

Concepts. Products. Service. From one source. Plafotherm Plasterboard Heated and Chilled Ceilings

INTERNATIONAL OVERVIEW John Wilkinson SVP Sales & Products

RPV - RP - RA air handling units

Report on Government Information Requests

How To Build A Powerline Box Powerline Generator

Unbeatable energy efficient glass curtain wall system

Transcription:

Cleanroom systems HVAC systems for hospitals

Let us explore together the different building areas Pages 4 5 Reception / Waiting area Pages 6 9 Best air management solutions through customized systems KRANTZ KOMPONENTEN has been a leading specialist in comprehensive HVAC system solutions for more than 40 years, and has been supplying innovative ventilation and air-conditioning systems for hospitals and clean rooms for over 20 years. Examination / Treatment Operating area This overview presents air management solutions based on innovative systems designed to match any user requirements. We shall be glad to work out customized solutions together with you. Pages 10 13 Regeneration Pages 14 15 Just contact us! Take advantage of our expertise and experience. Early dialogue with clients, investors, architects, and design consultants Very high level of quality, efficiency and reliability Ease of operation and maintenance of our systems Research / Teaching Laboratory, lecture hall, administrative area Pages 16 19 Let us convince you of our creative approach to optimum design solutions. Visit our website www.krantz.de 2 3

Let us explore together the different building areas Administrative area Air distribution systems Ceiling air outlets Sidewall air outlets Floor air outlets Displacement outlets Air outlets for assembly rooms Regeneration Cooling and heating systems High-capacity ceiling systems Metal, gypsum board and plaster ceiling systems Chilled sails Chilled beams Facade/Floor-mounted systems Wall-mounted systems Cleanroom systems HVAC systems for hospitals Volume flow controller Examination / Treatment Research / Teaching HEPA filter air outlets Ventilation and air-conditioning systems for hospitals Supply air ceiling and recirculated air ceiling for operating rooms Reception / Waiting area Fibre filter Dissection outlet Filter Fan Units Clean work stations 4 5

Opticlean OC-Q Reception / Waiting area Contact cooling ceiling system KKS-3/LD, for metal ceilings Thermal comfort coupled with attractive design The reception and waiting area is, so to speak, the business card of a building. Innovative air distribution systems in aesthetic design set new architectural trends while ensuring optimum thermal comfort. The chilled sail AVACS is the result of further The Opticlean OC (with square or circular Radiant cooling and heating ceilings provide developments on our chilled sails. It combines faceplate) has been developed in order to com- a comfortable climate. KKS-3/LD is used for the proven chilled ceiling technology with air bine in a single product the main features of metal acoustic ceilings and KKS-4/GK for vari- diffusers that are invisible to room occupants. a ceiling-mounted supply air outlet for diffuse ous types of gypsum board ceilings. PKS-D is The exposed part of the AVACS chilled sail is an indoor air flow, i.e. high level of thermal comfort, used for plastered ceilings. assembly of perforated rectangular metal tiles unobtrusive integration into the suspended ceil- which incorporate the contact cooling ceiling ing, very low amount of dirt accumulated on the system KKS-3/LD for metal ceilings. ceiling, and low sound power level. Nominal width: 1 200 mm Size OC-Q: 250 625 Dimensions: variable Nominal length Size OC-R: 300 and 500 Cooling output to EN 14240 (Dt 10 K) of each metal tile: 2 800 mm Discharge height: 2.5 4.5 m KKS-3/LD: 116 W/m2 Suspension height: min. 150 mm Volume flow rate range: Volume flow rate: 28 l/s [100 m3/h] Cooling output: up to 160 W/m2 6 KKS-4/GK: 89 W/m2 OC-Q: 17 222 l/s [60 800 m3/h] PKS-D: 80 W/m2 OC-R: 25 170 l/s [90 610 m3/h] Heating output: > 100 W/m2 is achiev- Temp. differential: 8 K to +6 K able (Dt 15 K) Chilled sail AVACS 7

Adjustable induction outlet IN-V Swivel jet nozzle DW-V2 High-capacity convective system LUVAS-S Rectangular floor displacement outlet Q-BR Diffuse indoor air flow and a multitude of design options Radial outlets RA-N3 are available with square Adjustable induction outlets IN-V are lin- Swivel jet nozzles DW-V2 are used to air- The linear whirl outlet WL produces turbulent LUVAS-S profile systems consist of cooling/ The rectangular floor displacement out- or circular face. They generate high-quality dif- ear ceiling air outlets that are eminently suited condition large spaces or galleries with very mixing ventilation. It can be installed in ceilings heating elements that are available in several let Q-BR is designed to deliver supply air to fuse air flow according to the principle of tur- for installation in suspended ceiling systems in high acoustic requirements. and walls. Applications are rooms with high lengths and for versatile applications. They commercial rooms with raised floors or floor bulent mixing ventilation. They can be installed commercial buildings. acoustic and thermal comfort requirements, leave great room for creativity in installation plenums. The air outlet generates a combined The discharge direction can be adjusted to any e.g. offices, restaurants, assembly rooms as scenarios in line with the design of the space mixing/displacement flow or hybrid flow as Good visual integration into ceiling thanks to position in the horizontal and vertical planes. well as lobbies and entrance halls. concerned. As this system may include one or described in the German guideline VDI 3804. small width of visible air outlet profile, in particu- The jet discharge angle can be adapted to the several profiles in combination, it affords a high The advantage of this hybrid flow over a mere lar that of IN-V3 (only 15 mm wide). desired operating conditions. degree of flexibility and can be used both in displacement flow is a low vertical temperature new and existing buildings. gradient with lower air discharge temperature. free-hanging from the ceiling, above open grid or expanded metal ceilings, or flush with closed false ceilings or square tile ceilings. 8 Size: DN 355 and DN 500 Element width: 15 or 28 mm Nominal size: DN 60 to DN 250 Discharge chamber height: 30, 45 and 65 mm Nominal length of each profile: up to 1 800 mm Unit length: 800 1 900 mm Discharge height: 2.4 4.5 m Number of outlet rows: 1 4 Throw: 3 50 m Penetration depth: 4 16 m Width: Unit depth: 140 340 mm Volume flow rate range: 26 400 l/s Discharge height: 2.5 5 m Discharge height: 2.5 10 m Discharge height: 2.6 6 m Space requirement in depth: 145 mm Unit height: [95 1 440 m3/h] Volume flow rate range: 2.8 110 l/(s m) Volume flow rate range: 11 589 l/s Volume flow rate range: 28 300 l/s Cooling output: up to 275 W/m Volume flow rate: up to 55 l/(s m) Temperature differential: 12 K to +5 K [10 400 m3/(h m)] [40 2 120 m3/h] [100 1 100 m3/h] Heating output: 400 W/m [200 m3/(h m)] 62 or 105 mm 190 mm Adjustment: manual Grille: aluminium electric stainless steel self-acting wood Radial outlet RA-N3 Linear whirl outlet WL 9

Puri twist outlet PDK Fibre filter F Operating area Best treatment conditions Demanding requirements have to be complied with when designing and building a complete "operating room" system. During this process the protection of patients and staff is the centre of attention. Standards and guidelines provide safety. Our systems fulfil the requirements of DIN 1946-4 "Ventilation in buildings and rooms of health care" and are suited for all room classes (Ia, Ib and II) described therein. Very often wall heating is necessary in operating rooms. The wall heating-cooling element WHK-GK is used in gypsum board walls, and the plaster system PKS-W is used in plastered walls. The Puri twist outlet PDK for turbulent mixing ventilation, with HEPA filter, is suited for air cleanliness levels of Class 6 to 8 to EN ISO 14644-1 and Grade C and D to EU GMP guidelines as well as for treatment rooms of Class Ib to DIN 1946-4. The Puriclean PCK has the same properties as the Opticlean (p. 7) and is easy to clean. The fibre filter F is used to remove textile fibres from the exhaust air of operating rooms and ancillary rooms. The fibres are removed directly at the extract point. The fibre filter is built into the wall of the clean room or exhaust air duct. Dimensions: customizable Heating output to EN 14037 ( t 15K) WHK-GK: 84 W/m 2 PKS-W: 120 W/m 2 Cooling output: 30 W/m 2 (Dt 8 K) Size: DN 250 to DN 400 Discharge height: 2.4 4.5 m Housing height: 432 mm Volume flow rate range: 69 389 l/s [250 1 400 m 3 /h] Width x height: 225 x 225 mm to 825 x 825 mm Depth: 80 mm Volume flow rate range: 65 1 670 l/s [230 6 000 m 3 /h] 10 Wall heating-cooling element WHK-GK 11

Air flow stabilizers made of special glass Special central frame for passage Laminar-flow discharge elements Decentralised recirculated air modules including mixing chamber of OR light flange tube Systems to meet the highest demands The supply air ceiling OP-Z-32/32 generates a vertical, homogeneous, low-turbulence displacement flow with low pressure drop. This supply air ceiling has been designed and certified according to DIN 1946-4 (2008-12) for all operating room (OR) classes. Due to its modular design and the different types of air connection available, this system is ideally suited for installation in the ceiling plenum, even if this has a low height and offers limited space. The supply air flows through the critical area surrounding the central flange tube for the OR light thanks to a purpose-made fabric frame. Thus, the low-turbulence displacement flow is available over the full supply air ceiling area. Further, this design allows optimum access to the connection flange of the OR light for maintenance at any time. The ventilation function of the recirculated air ceiling OP-U-32/32 is similar to that of the supply air ceiling described before. The special design of the recirculated air modules makes it possible to fit the OP-U-32/32 ceiling with ceiling services for medical applications or media bridges as well as with a perimeter lighting system. The recirculated air modules serve to draw in and mix outdoor air and recirculated air and to deliver the resulting blend to the operating room quietly. For this purpose, each module is fitted with an EC fan, an innovative mixing chamber and an F7 prefilter. The advantage of our innovative mixing chamber is that it obviates the need for an air cooler in the ceiling plenum. The sound pressure level in the middle of the room meets the specifications. Size (standard): 3 200 x 3 200 mm Volume flow rate range: 2 555 3 600 l/s [9 200 13 000 m 3 /h] Size (standard): 3 200 x 3 200 mm Volume flow rate range: 2 555 3 056 l/s [9 200 11 000 m 3 /h] 12 13

Broad multiplex outlet BF-V Multiplex outlet FA-VT Regeneration Ideal air quality and state-of-the-art solutions In medicine, regeneration means restoration of a body's normal function. During regeneration the organism tries to heal damaged tissue or organs by building new cells. To make the patients' stay less unpleasant, hospitals provide comfortable rooms with a cosy atmosphere. The adjustable wall slot diffuser WSD is a slim air outlet with aesthetic design. Since it requires little space, it is specially designed for installation in standard gypsum board walls. It generates turbulent mixing ventilation. The wall slot diffuser is particularly suitable for offices and rooms with concrete slab cooling. The broad multiplex outlet BF-V has been developed to fulfil the high thermal comfort criteria required in commercial applications. The broad multiplex outlet is well suited to replace existing sidewall air outlets and air grilles. This is an optimum way to significantly improve thermal comfort in rooms at low cost. The multiplex outlet FA-VT generates highturbulence mixing ventilation with spread-out air jets. The multiplex outlet is a sidewall air outlet whose front plate generates a large number of thin air jets through built-in jet bundle elements. The discharge direction of these elements being adjustable, the supply air jets can be spread out as required. Nominal length: 525, 1 050, 1 125 mm Discharge height: 2.4 3.5 m Volume flow rate: up to 66.5 l/s [240 m 3 /h] per metre of diffuser length Temperature differential: 10 K to +6 K Nominal length: 600, 800, 1 000 mm Mounting height: 2.2 4 m Volume flow rate range: 22 150 l/s [80 540 m 3 /h] Temperature differential: ±10 K Nominal length: 600, 800, 1 000 mm Discharge height: 2.5 4 m Volume flow rate single-row: 43 l/(s m) [155 m 3 /(h m)] double-row: 50 l/(s m) [185 m 3 /(h m)] Temperature differential: ±12 K 14 Wall slot diffuser WSD 15

Laboratory, lecture hall, administrative area Radial slot outlet RL Puriclean PCK Customized systems to meet the most varied demands In a hospital the requirements for the ambient air conditions are very different depending on the building areas. For instance, hospital pharmacies and laboratories, which deal and work with substances that are hazardous to health, require specific air distribution systems that will ensure the protection of people and medicines. The dissection outlet SZ is a displacement The radial slot outlet RL generates turbul- The Puri twist outlet PDK for turbulent outlet which is placed above the dissection ent mixing ventilation and is used for sup- mixing ventilation, with HEPA filter, is suited Lecture halls and seminar rooms must accom- table and discharges a laminar flow of supply ply air distribution in commercial buildings. for air cleanliness levels of Class 6 to 8 to modate a great number of people. The indoor air into the dissection zone. The air pollutants It is particularly suitable for rooms with high EN ISO 14644-1 and Grade C and D to air quality and the acoustic performance of the are thus displaced downwards and the polluted indoor air flow requirements and can be EU GMP guidelines. air-conditioning systems are of vital importance air is extracted at floor level. installed flush with the ceiling or free-hanging. The Puriclean PCK has the same properties for occupant comfort and learning success. as the Opticlean (p. 7) and is easy to clean. Even in rooms where the risk of infection is low, e.g. in the administrative area, the indoor air Length x width: 2 120 x 1 130 mm Size: 300 800 Nominal size: DN 250 to DN 400 quality has to be brought to a level that is con- Height: 300 mm (standard) Discharge height: 2.5 4.5 m Discharge height: 2.4 4.5 m ducive to good health. Volume flow rate range: 210 280 l/s Volume flow rate range: 20 330 l/s Housing height: 432 mm [750 1 000 m3/h] [75 1 200 m3/h] Volume flow rate range: 69 389 l/s Lighting intensity: > 1 100 Lux Temperature differential: 12 K to +5 K [250 1 400 m3/h] Discharge direction: 2-, 3- or 4-sided 16 Dissection outlet SZ 17

Induction outlet with preset discharge direction IN-N6 Adjustable radial outlet with core tube RA-V2 Chilled beam DK-LIG/Z, with ventilation Ventilation unit (supply/return air) for mixing ventilation LG-ZA-M-SB, for vertical parapet mounting function, two-sided discharge High air quality and many system configurations Step displacement outlets Q-SR and Q-SL The induction outlet with preset discharge The adjustable radial outlet with core tube The static cooling ceiling system SKS-5/3 The chilled beam DK-LIG, with ventilation The ventilation unit LG-ZA-M-SB is designed are used to supply air to assembly rooms with direction IN-N6 is a linear ceiling air outlet that RA-V2 generates a diffuse air flow according to comes into use as exposed ceiling elements function and one-sided or two-sided dis- for integration into the parapet of a facade. It seating arranged on stepped floors, such as is eminently suited for installation in suspended the principle of turbulent mixing ventilation and having an attractive linear-panel appearance. charge, is used for room cooling and heating enables ductless ventilation as it is fitted with auditoria, convention centres, theatres, etc. ceiling systems in commercial buildings. The is particularly suited for large thermal load vari- This system can be designed as free-hanging in commercial buildings. High cooling outputs direct outdoor and exhaust air connections. It They operate according to the principle of discharge element has a number of consecu- ations in commercial applications as well as for chilled sail or chilled island. and fresh air supply to enhance the indoor air provides the following functions: fresh air sup- displacement ventilation and are designed for tive jet channels which are inclined at a 45 great ceiling heights. The direction of the supply quality. ply, cooling, heating, operation with heat recov- installation in step risers, directly behind the angle to the horizontal, alternately to the right air jets is adjustable from horizontal to vertically ery, and operation with recirculated or outdoor seats. and to the left. This enables alternate air dis- downwards, depending on the supply air tem- air. charge. perature. circular: DN 80 and DN 100 Length: 1 000 1 600 mm Nominal size: DN 250 to DN 900 Nominal width: up to 1 480 mm Nominal width: 300 and 600 mm Width: 1 000 mm rectangular: variable Discharge height: 4 7 m Discharge height: 2.8 18 m Nominal length: up to 4 000 mm Nominal length: up to 3 000 mm Height: 650 mm Volume flow rate Volume flow rate range: 28 85 l/(s m) Volume flow rate range: 83 3 055 l/s Cooling output: up to 160 W/m2 Primary air Depth: 297 mm DN 80: 10 l/s [35 m3/h] [100 300 m3/(h m)] Nominal size DN 100: 16.5 l/s [60 m3/h] rectangular: 21 l/(s m) [75 m3/(h m)] Temperature differential: 10 K to +6 K [300 11 000 m3/h] volume flow rate: 3 25 l/(s m) m3/(h m) Temperature differential: ±12 K 10 90 Adjustment: manual Cooling output: up to 820 W/m electric self-acting Volume flow rate: max. 53 l/s [190 m3/h] Total cooling output: 720 W Total heating output: 1 200 W Static cooling ceiling system SKS-5/3, 18 Step displacement outlet Q-SL for visible installation 19

Sales offices in Germany Agencies worldwide Europe Africa America Asia Australia Caverion Deutschland GmbH Austria Krantz Komponenten Belgium Uersfeld 24, 52072 Aachen Cyprus Germany Denmark Phone: +49 241 441-1 Finland Fax: +49 241 441-555 France info@krantz.de, www.krantz.de Greece Great Britain Aachen Iceland Dresden Ireland Frankfurt Hamburg Munich Stuttgart Italy Netherlands Norway Poland Portugal Russia Spain Switzerland Turkey South Africa Canada Mexico USA Bahrain China China - Hong Kong Japan Kuwait Qatar Singapore South Korea Taiwan Thailand United Arab Emirates Australia New Zealand K 243 e / 12.2012 Subject to technical alterations