1 Air management solutions at ceilings and facades High-capacity cooling ceiling elements Radiant cooling ceiling elements Chilled beams Customized solutions Chilled sails Parapet air supply units Summary
2 Pages 4-7 Pages 8-11 Air-and-water systems provide both versatile and economic solutions for different types of buildings and usage as well as for individual requirements. KRANTZ KOMPONENTEN has been an expert on HVAC systems for more than 40 years; for more than 15 years now it has also been a leading manufacturer of innovative products for cooling ceilings. Pages This summary presents different air management solutions as well as innovative components for air-and-water systems. Whether you have high-end or low-budget requirements, you will find an appropriate solution. Further, we are at your service to develop customized solutions together with you. Pages Design/layout options for cooling ceilings of any type Pages Concrete ceiling or suspended ceiling A B C A) Layout as chilled sail Concrete ceiling B) Layout as chilled island flush with an open or closed false ceiling Cooling ceiling Sound-absorbing material (optional) Cooling ceiling Suspended ceiling (passive) C) Design as full-coverage suspended ceiling (with active and passive areas) with/without linear grid Concrete ceiling Cooling ceiling To get more details, refer to our 'Technical Selection' brochures and/or our technical reports, or simply call us. The know-how of our engineers and R&D lab personnel is a guarantee for the right selection, good quality and reliable operation of our systems under the most varied conditions.
3 High-capacity cooling ceiling elements Radiant cooling ceiling elements Chilled beams Customized solutions Chilled sails Parapet air supply units Combination of cooling ceilings with different air distribution systems Turbulent mixing air flow Cooling ceiling with ceiling twist outlet with induction outlet with sidewall air outlet Low-turbulence displacement air flow with floor twist outlet with wall displacement outlet with displacement outlet
4 Concealed installation Het Valkhof museum, Nijmegen/NL Wood panel ceiling with SKS-4/1 (combined with plinth displacement outlets) Particularly suitable for ceilings with large free areas, e.g.: strip ceilings panel ceilings grid ceilings expanded metal ceilings metallic fabric ceilings metal acoustic ceilings (Perforations > 20%, no acoustic tissue or similar) These cooling ceiling elements can be easily combined with closed ceiling systems (made from metal, gypsum board, mineral fibres, etc.). 4 Verbands-Sparkasse Wesel (savings bank), Wesel/D Longitudinal tile ceiling made from expanded metal with parallel strip grid and SKS-4/1 for both cooling and heating (combined with natural ventilation) Distinctive features: Uses the retention capacity of the concrete ceiling No combustible components Combinable with any air distribution system SKS elements are independent of the suspended ceiling; therefore the ceiling construction and the installation of mechanical equipment and ceiling utilities can largely occur separately. Sound absorption level Pariser Atelier Boutique Theatinerstrasse GmbH, Munich/D Coffered metal ceiling with perforations (A 0 = 30%), with SKS-4/1 (combined with turbulent mixing air flow from the ceiling radial outlet) Frequency in Hz SKS - 4/1 Achievable levels of sound absorption e.g. longitudinal tile ceiling made from metal, with perforations, with SKS-4 cooling elements and sound-absorbing material of different types at different locations of the false ceiling plenum (perforations open, A 0 > 22%, B = mm) A 0 = free area B = thickness of soundabsorbing material
5 5 Cooling output of high-capacity cooling ceiling elements for concealed installation Specific cooling output of active cooling surface in W/m SKS-4/1 SKS-4/1* SKS-4/3 SKS-4/3* SKS-4/1** SKS-FD SKS-4/1*** SKS-4/3** SKS-4/3*** Temperature difference (room temperature to mean water temperature) in C Influence of free area A 0 of suspended ceiling SKS-4/1 suspended ceiling with A 0 > 65% SKS-4/1* suspended ceiling with A 0 = 40% SKS-4/1** suspended ceiling with A 0 = 25% SKS-4/1*** suspended ceiling with A 0 = 20% SKS-4/3 suspended ceiling with A 0 > 65% SKS-4/3* suspended ceiling with A 0 = 40% SKS-4/3** suspended ceiling with A 0 = 25% SKS-4/3*** suspended ceiling with A 0 = 20% SKS-FD suspended ceiling with A 0 > 65% The SKS elements can be installed anywhere inside the grid of the ceiling suspended structure. It is possible to place elements of up to 4 m length parallel to the basic profiles. SKS - 4/3 = Basic profiles Placement of air outlets False ceiling Installation flush with closed false ceiling Installation above an open ceiling with A 0 > 65% Mittelbrandenburgische Sparkasse (savings bank), Rathenow/D Grid ceiling with gypsum board strips and SKS-4/1 Layout options for SKS elements and sound-absorbing material Sound-absorbing material Suspended ceiling, perforated or similar SKS elements High-capacity cooling ceiling elements for concealed installation
6 RBB broadcasting, studio A, Potsdam Babelsberg/D SKS-3 cooling elements built into the ceiling, visible (combined with turbulent mixing air flow from the ceiling, variable twist outlet) Sparkasse Neuss (savings bank), Korschenbroich/D SKS-5/1 cooling ceiling elements flush with the metal acoustic ceiling SKS - 5/1 Examples of covers for U-shaped frame profiles Reifenhäuser GmbH & Co. KG Maschinenfabrik, Troisdorf/D SKS-5/3 cooling ceiling elements flush with perforated metal ceiling panels (combined with turbulent mixing air flow from the ceiling, induction outlet) and with sound-absorbing material SKS - 3/2 Visible installation 6 Cooling ceiling elements designed as panels or linear strips are made to match the room design as far as possible. The regular arrangement of these modular elements allows for versatile space layout. In combination with conventional suspended ceilings, large ceiling surfaces can be designed aesthetically pleasing and with a high level of functionality. SKS - 5/3 Placement of air outlets Distinctive features: High cooling output with high percentage of radiation Usable as independent ceiling system or combined with conventional ceilings Various design and arrangement options Uses the retention capacity of the concrete ceiling Low installation height Induction outlet installed in the 15 mm wide gap inside a SKS-5/1 cooling ceiling element
7 7 Cooling output of high-capacity cooling SKS-3/ SKS-3/2* 200 SKS-5/1 SKS-5/4 SKS-5/ SKS-5/3* 140 SKS-3/2 as chilled sail, free-hanging SKS-3/2* as chilled island, flush with closed passive ceiling A0 = 0% SKS-5/1 as chilled sail, free-hanging SKS-5/4 as chilled sail, free-hanging SKS-5/3 as chilled sail, free-hanging SKS-5/3* as chilled island, flush with closed passive ceiling A0 = 0% Layout options for SKS elements and sound-absorbing material SKS - 5/ Sound-absorbing material 50 Lighting fixtures can 50 be either built into SKS elements or placed beneath or SKS - 3/2 between them. DB Cargo, Mainz/D SKS-5/1 cooling ceiling elements flush with perforated gypsum board ceiling and metal ceiling panels (combined with turbulent mixing air flow from the ceiling, induction outlet) HNF Heinrich Nixdorf MuseumsForum, Paderborn/D SKS-3 cooling ceiling elements in visible installation (combined with displacement air flow, step displacement outlet) High-capacity cooling ceiling elements for visible installation Temperature difference (room temperature to mean water temperature) in C 100 Specific cooling output of active cooling surface in W/m2 ceiling elements for visible installation
8 Rectangular tile ceiling made from metal (perforated) with parallel strip grids and KKS-1 elements for both cooling and heating (combined with turbulent mixing air flow from the ceiling, induction outlet) Eurohaus office building, Frankfurt am Main/D Rectangular tile ceiling made from metal (perforated) with parallel strip grids and KKS-1 cooling elements (combined with turbulent mixing air flow from the ceiling, induction outlet) For metal ceilings If provided with radiant cooling ceiling elements, any type of metal acoustic ceiling from any manufacturer can be used as a radiant cooling or heating ceiling. The durable large-surface contact to the ceiling tile is preferably done with adhesive. Thermogram of a metal acoustic ceiling with active KKS-1 elements 8 Distinctive features: Heat transmission mainly by radiation Easy to adapt to ceiling tile dimensions, capacities and sound-absorbing properties Low installation height Jointless appearance also possible No combustible component KKS -1 Metal acoustic ceiling used as cooling ceiling 9* 10* 1 Strip grid 2 Suspension fixture 3 Ceiling tile, passive 4 Ceiling tile, active 5 Visible perforations (on room side) 6 Acoustic tissue 7 KKS-1 elements* 8 Insulating material 9 Cooling water flow* 10 Cooling water return* 11 Connection hose* * Delivered by KRANTZ KOMPONENTEN 5 6 Axial grid 11* Metal acoustic ceiling used as cooling ceiling (here: parallel strip grid with rectangular tiles, cooling ceiling element in pull-down design) * 2 1
9 9 Cooling output of radiant cooling ceilings KKS-1/LD KKS-1/TWIN KKS-1/LD KKS-3/LD 100 KKS-1/LD T T T T = = = = mm mm mm mm T = 120 mm T = pipe division KKS -1 elements are bonded to ceiling tiles at the works or on site; for KKS -3 elements this is always done at the works. KKS - 3/LD Frankfurter Welle office and shop building, Frankfurt am Main/D Rectangular tile ceiling made from metal (perforated) with KKS -1 elements (combined with turbulent mixing air flow from the ceiling, induction outlet) Office with rectangular tile ceiling made from metal and KKS-1 elements (combined with turbulent mixing air flow from the wall, broad multiplex outlet with return air removal via upper outlet segment) Mean levels of sound absorption 1 Standard metal acoustic ceiling (A0 = 18%, B = 40 mm) 2 Wilhelmi Mikropor M metal acoustic ceiling (B = 40 mm) with KKS-1 elements Cooling ceiling under construction Frequency in Hz Radiant cooling ceiling elements - for metal ceilings Temperature difference (room temperature to mean water temperature) in C Sound absorption level Specific cooling output of active cooling surface in W/m2 KKS contact cooling ceiling system for metal ceilings
10 For gypsum board If provided with radiant cooling ceiling elements, perforated or non-perforated gypsum boards (and related suspended structures) from any manufacturer can form a jointless radiant cooling or heating ceiling. The durable large-surface contact to the gypsum board is preferably done with screws or adhesive. Lotto Rheinland-Pfalz GmbH, Koblenz/D Gypsum board cooling ceiling with KKS-2 elements (combined with displacement air flow, plinth displacement outlet) KKS - 2 element, non-perforated Sound-absorbing gypsum board cooling ceiling under construction Thermogram of a non-perforated gypsum board cooling ceiling with active KKS-2 elements KKS - 2 element, perforated KKS-3/GK is also used for wall heating-cooling 10 Distinctive features: Heat transmission mainly by radiation elements with a standard width of 625 mm. Several design options for braced grid or interlocked grid system Heating output: approx. 150 W/m 2 at 25 K; Primary grid Sound-absorbing design with visible or concealed perforations Low installation height No combustible component cooling output: approx. 54 W/m 2 at 10 K. KKS -3/GKW Knauf Thermoboard Secondary grid Copper serpentine pipework Maximum cooling output when using Knauf Thermoboard K713 or Sheet metal equivalent Design of gypsum board cooling ceiling, perforated or non-perforated, with KKS-3 Space for water connection
11 11 Cooling output of radiant cooling ceilings 100 KKS-2/GK T non-perforated KKS-3/GK T non-perforated KKS-2/GK T perforated 90 KKS-3/GK B non-perforated Drop in output with standard 12.5 mm gypsum board instead of 10 mm Knauf Thermoboard K KKS-3/GK, perforated KKS-2 calls for an equilevel interlocked grid, whereas KKS-3 requires a braced grid system. Congress Centrum Alpbach /A Gypsum board cooling ceiling, partly with and partly without perforations, with KKS-2 (combined with turbulent mixing air flow from the ceiling, induction outlet) 20 mm thick mineral fibre insulation or equivalent insulating material Concrete ceiling Support profile Snap-in hook Basic profile Vernier suspension fixture * * * Kreditanstalt für Wiederaufbau, Berlin/D Perforated Knauf Thermoboard with mat and Scherff acoustic plaster, activated with KKS-2 X Perforated gypsum board Al heat conducting plate Cu serpentine pipework Support mat Acoustic tissue Acoustic tissue Fine acoustic plaster: 2 3 mm e.g. from Scherff Detail X Detail X Perforations *Supplied by KRANTZ KOMPONENTEN Design of gypsum board cooling ceiling, perforated, with KKS-2 Radiant cooling ceiling elements for gypsum board Temperature difference (room temperature to mean water temperature) in C Suspension height from 80 mm upwards Specific cooling output of active cooling surface in W/m2 KKS contact cooling ceiling system for gypsum board
12 DK-FZ Chilled beams with high cooling output should not be installed above permanent workplaces! Audi Forum, Ingolstadt/D Passive chilled beams DK-FZ above an expanded metal ceiling with free area > 60% Typical pattern of cool air discharged by a passive chilled beam DK-F Only cooling function 12 Chilled beam installed close to a facade Chilled beam installed close to a corridor wall Passive chilled beams are designed for cooling rooms at high output. A number of installation options are possible. Thanks to simple and compact design they provide lowcost solutions. Distinctive features: High specific cooling output Various installation options Easy mounting Hygiene-tested to VDI 6022, Sheets 1 + 3, VDI 3803, and DIN 1946, Parts Numerous aesthetic design options thanks to a range of screens and adaptable dimensions
13 13 Cooling output of passive chilled beams, type DK-FZ 400 H = 250 mm 350 H = 180 mm Specific cooling output in W/m Width 600 mm Width 400 mm Width 250 mm H = 250 mm H = 180 mm H = 250 mm H = 180 mm Temperature difference (room temperature to mean water temperature) in C These cooling output values are achieved with sufficient flow and reflow surfaces and a free area > 60%. Installation options Kreditanstalt für Wiederaufbau, Berlin/D Passive chilled beams DK-FZ above perforated Al ceiling tiles close to facade Passive chilled beam Type DK-F Bayerischer Rundfunk, Munich/D Detail of DK-FZ above an open expanded metal ceiling in combination with induction outlets Audi Forum, Ingolstadt/D DK-FZ above an expanded metal ceiling with free area > 60% Bayerischer Rundfunk, Munich/D DK-FZ above an expanded metal ceiling with free area > 60% (combined with turbulent mixing air flow from the ceiling, induction outlet)
14 With ventilation function Coffered ceiling with built-in DK-LIG/Z in an office All main functions cooling, heating, and fresh air supply available in a compact unit. This chilled beam is easy to install in any suspended ceiling system or freehanging from the ceiling. It can be fitted with so-called wings that serve as covers in case of free-hanging installation or that enable to accommodate lighting and other ceiling utilities; in latter case the chilled beam turns to a multipurpose unit. The chilled beams are 250 mm or 280 mm high. They fit well in a ceiling plenum 300 mm. DK-LIG/E Coffered ceiling with built-in DK-LIG/Z in a recreation room DK-LIG/Z DK-LIG/ZM Spigot 14 Distinctive features: Cooling and heating with simultaneous supply of the requisite outside air percentage to suit hygienic requirements No need for extra reflow surfaces when used in closed ceiling systems Easy access to heat exchanger from room for cleaning purposes Hygiene-tested to VDI 6022, Sheets 1 + 3, VDI 3803, and DIN 1946, Parts Suitable for low floor-to-ceiling heights in new or refurbished buildings Several aesthetic design options thanks to a range of screens as well as so-called wings Housing Primary air Primary air Supply air Spigot Secondary air Screen Primary air nozzle Heat exchanger for cooling and heating (2 or 4-pipe system) Construction design and mode of operation with two-sided discharge Housing Nozzle Heat exchanger for cooling and heating (2 or 4-pipe system) Supply air Screen Secondary air Construction design and mode of operation with one-sided discharge
15 15 Cooling and heating outputs of active chilled beams, type DK-LIG Cooling output 600 Nozzle A Mean water temperature to room temperature = 10 C Primary air temperature to room temperature = 8 C 550 Nozzle B Nozzle C Heating output 400 Mean water temperature to room temperature = 15 C Primary air temperature to room temperature = 0 C (isothermal) 350 Nozzle A 300 Nozzle B 250 Nozzle C Specific primary air volume flow rate in m3/(h m) Active chilled beam Type DK-LIG Total output (airside and waterside) in W/m 650 Abbott Laboratories, Wiesbaden/D Open-plan office Linear grid ceiling with built-in DK-LIG/Z during installation Placement of DK-LIG with two-sided air discharge Placement of DK-LIG with one-sided air discharge University of Wolverhampton /GB Active chilled beams DK-LIG/ZM free-hanging from the concrete ceiling, fitted with so-called wings for covering fresh air ducts and water supply pipes University of Wolverhampton /GB Free-hanging active chilled beams installed with airsides in series, covered with so-called wings
16 Universal Music, Berlin/D Chilled sails made up of perforated metal rectangular tiles with KKS-1 elements Infineon Technologies AG, Munich/D Chilled sails made up of perforated metal rectangular tiles with KKS-1 elements Chilled sail A product resulting from the broad array of cooling ceiling elements combined with aesthetic design Curved chilled sail made from gypsum board with KKS-2 Sound-absorbing Combination of chilled sail with wall slot diffuser or wall-mounted multiplex outlet material can be applied to the rear. All types of cooling ceiling systems described in the foregoing can be used as chilled sails for cooling or heating they afford all benefits mentioned before while having unique shapes and dimen- 16 Chilled sail with ceiling displacement outlet sions. The concrete ceiling can be activated or kept as energy storage space. Distinctive features: Chilled sail made from perforated gypsum board with built-in ceiling utilities Compact prefabricated units of high quality Easy and quick installation on site Customized design and functionality Combination of chilled sail with wall displacement outlet Can incorporate lighting, air outlets, smoke detectors and other ceiling utilities Chilled sail made up of perforated metal rectangular tiles with free-hanging lighting fixture Broad array of surface textures
17 17 Cooling output of active cooling ceiling surface depending on t and ceiling type 2 bo ar d 10 ps um 9 S + gy 8 K K 7 6 K K S + m et c al ei lin 1/3 g S KS 5 SK 4 S SKS-5 as free-hanging chilled sail SKS-5 built into a closed ceiling SKS-4 above a perforated metal ceiling (A0 25%) SKS-4 above an open grid ceiling (A0 > 65%) or in visible installation 160 Specific cooling output q in W/m2 of cooling element ϑ SKS-3/2 elements viewed from the opposite direction ϑ Orange Communications, Biel/CH Chilled sails made up of SKS-3/2 elements ϑ Schindler AG, Ebikon/CH Chilled sails made up of SKS-5/3 elements ϑ Infineon Technologies AG, Munich/D Chilled sails made up of perforated metal rectangular tiles with KKS-1 elements Customized solutions Chilled sails Room temperature to mean water temperature t in K 11
18 Universal Music, Berlin/D Chilled sails made up of SKS-4/1 elements University of Eindhoven/NL Chilled sails made up of SKS-5/1 elements with frame covers and built-in lighting fixtures Orange Communications, Biel/CH Chilled sails made up of SKS-3/2 elements in a call centre High cooling loads 18 For rooms with high cooling loads, chilled sails made up of the most various high-capacity cooling ceiling elements from KRANTZ KOMPONENTEN provide a broad array of solutions. Even under difficult conditions they afford the following: High level of thermal comfort Economical air volume flow rates Low operating and maintenance costs Customized system solutions. SKS-3/2 element as chilled sail with built-in lighting fixture from SITECO SKS-5/3 element as chilled sail with built-in lighting fixture from SITECO
19 19 Free choice of shape and Migros, Schönbühl/CH Chilled sails made up of SKS-4/1 elements with self-supporting frames (combined with turbulent mixing air flow from the ceiling, twist outlet) size of chilled sails Branch ducts and pipes from the corridor are concealed Lighting fixtures and other ceiling utilities are integrated into the chilled sail Reimer Engineering at Minden/D SKS-5/1 cooling ceiling elements with covers on U-shaped frame profiles, designed as chilled sails for cooling and heating (combined with turbulent mixing air flow from the ceiling, twist outlet) Orange Communications, Biel/CH Chilled sails made up of SKS-3/2 elements Customized solutions Chilled sails Holland Casino, Nijmegen/NL Chilled sails made up of SKS-5/1 elements with frame covers
20 DeutschlandRadio, Cologne/D Combijet parapet unit BG-K with casing DeutschlandRadio, Cologne/D Office with BG-K unit With centralized primary air conditioning Cooling, heating, and fresh air supply all in one unit. These units are easy to install along a building facade and to match up with the room design thanks to customized parapet casings. Air discharge element Combijet parapet unit BG-K with dual-system discharge element for better fresh air supply to the occupied zone Depending on model, the unit height is between 450 and 680 mm. These units are therefore easy to integrate into standard window parapets. Air flow pattern of BG-K with facade screening 20 Distinctive features: Cooling, heating, and fresh air supply with high level of thermal comfort High specific cooling output Heating even without primary air Low sound power level Supply air distribution with facade screening or with low-turbulence displacement ventilation Low height Hygiene-tested to VDI 6022, Sheets 1 + 3, VDI 3803, and DIN 1946, Parts Air flow pattern of BG-Q with displacement ventilation
21 21 Cooling and heating outputs of combijet parapet units, type BG-K Waterside cooling output V L = 80 m3 /h V W = 190 l/h V L = Primary air volume flow rate V W = Water flow rate Waterside cooling output Q K in W V L = 65 m3 /h V W = 155 l/h V L = 50 m3 /h V W = 115 l/h Room temperature to mean water temperature ϑ R-Wm in K Waterside heating output Q H in W Waterside heating output V L = 80 m3 /h V W = 120 l/h V L = 65 m3 /h V W = 100 l/h V L = 50 m3 /h V W = 80 l/h V L = 0 m3 /h V W = 80 l/h Mean water temperature to room temperature ϑ Wm-R in K Air flow pattern of BG-K Mounting details at parapet Parapet air supply units Example of mounting Facade Supply air Room air/secondary air Floor air grille Floor air grille Floor induction unit Raised floor Ceiling of lower storey Unit foot, adjustable in height Air guide plate Sheet metal housing Control valves for heating/cooling Heat exchanger heating/cooling Primary air Primary air connection Primary air nozzle box Primary air nozzles Mounting of floor induction unit BI-HK Design and mode of operation of BI-HK
22 With decentralized outdoor air conditioning Controlled ventilation and air extraction, heat recovery, heating, cooling, free cooling all these functions performed by self-contained units, without ductwork, from the window parapet. Versatile modes of operation for individual users' requirements can be achieved in conjunction with bussable control units. The range of applications of these parapet units includes administrative buildings, open-plan offices, individual offices, educational buildings, etc.; the unit geometry is made to fit the facade. Ender-Bösch, Lustenau/A Office with facade ventilation unit Air intake and exhaust openings with hoods Adjustable induction outlet Facade ventilation unit, type FG-L, with adjustable induction outlet for facade screening and/or individual workplace ventilation 22 Distinctive features: Decentralized air supply at building facade Outdoor air intake and exhaust air extraction through the facade Ventilation without ductwork Self-contained units comprising air filters, heat recovery system, heat exchangers, air dampers, supply air and exhaust air fans, switch and control unit Supply air discharge via adjustable induction outlet or with low-turbulence displacement flow system Low sound power level Hygiene-tested to VDI 6022, Sheets 1 + 3, VDI 3803, and DIN 1946, Parts Linear vertical jet up the facade Jet spread out over the facade Linear vertical jet and plane jet for direct workplace ventilation
23 23 Room cooling and heating outputs of facade ventilation units, type FG-L Room cooling output in W Supply air temperature Room cooling output Supply air temperature in C Supply air volume flow rate in m3/h Water supply temperature in C British American Tobacco (BAT), Boncourt/CH Facade ventilation units FG-L during commissioning Outdoor air volume flow rate in m3/h 1200 Parapet air supply units Supply air temperature Room heating output Supply air temperature in C Room heating output in W BAT, Boncourt/CH Facade ventilation unit FG-L Water supply temperature in C Building-related system design using 3-D models Facade ventilation unit FG-L combined with recirculated air cooler of similar design Connection of ventilation unit FG-L to facade Recirculated air cooler
24 Head Office: Caverion Deutschland GmbH M+W Zander Gebäudetechnik GmbH Business Krantz unit Komponenten KRANTZ KOMPONENTEN P.O. Box , Aachen Uersfeld 24, Aachen, Germany Uersfeld 24, Aachen Germany Phone: , Fax: Phone +49 (0) Fax +49 (0) Website Sales agents in Germany at: Agencies worldwide: Aachen Berlin Dresden Frankfurt Hamburg Hanover Munich Stuttgart EUROPE A B CH Austria Belgium Switzerland AFRICA ZA AMERICA South Africa CY Cyprus CDN Canada E Spain MEX Mexico F France USA United States of America GB Great Britain GR Greece ASIA HR Croatia CHN China I Italy HK China (Hong Kong) IRL Ireland J Japan IS Iceland ROK South Korea N Norway SGP Singapore NL Netherlands UAE United Arab Emirates P Portugal AUSTRALIA and NEW ZEALAND PL Poland AUS Australia RUS Russia NZ New Zealand SK Slovakia TR Turkey You will find full details of our agencies at K 205 e / 06 Subject to technical alterations
Cleanroom systems. HVAC systems for hospitals
Cleanroom systems HVAC systems for hospitals Let us explore together the different building areas Pages 4 5 Reception / Waiting area Pages 6 9 Best air management solutions through customized systems KRANTZ
Air-water systems for efficient air conditioning
Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill
SP/1/EN/5. Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air
SP/1/EN/5 Product Summary KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue The art of handling air Components and Systems for Ventilation and Air Conditioning As an internationally leading manufacturer
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7
Product Summary KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue The art of handling air Special leaflet SP/1/EN/7 Components and systems for ventilation and air conditioning C As an internationally
Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com
Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION k-12 education Redefine your comfort zone. www.titus-hvac.com woodgrains dual-function energy solutions table of contents The CBAL-24 is
by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr.
HIGH DENSITY COOLING SOLUTIONS by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! optimiert! Setting benchmarks. Being the
Radiant Panels and Chilled Sails. www.price-hvac.com
Radiant Panels and Chilled Sails www.price-hvac.com Radiant Panels and Chilled Sails Introduction Radiant panels use thermal radiation to modify surface temperatures in order to provide sensible cooling
Active & Passive Beams
Active & Passive Beams Active & Passive Beams Introduction Beam systems are an alternative to traditional all-air conditioning systems. Beams use water to move energy through a building and service the
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund
Income INTECH Global Income Managed Volatility Fund Australia 0.0066 0.0375 Austria 0.0045 0.0014 Belgium 0.0461 0.0138 Bermuda 0.0000 0.0059 Canada 0.0919 0.0275 Cayman Islands 0.0000 0.0044 China 0.0000
Concepts. Products. Service. From one source. Plafotherm Plasterboard Heated and Chilled Ceilings
Concepts Products Service From one source. Plafotherm Plasterboard Heated and Chilled Ceilings 1 Building new solutions. Lindner undertakes major projects worldwide in all areas of interior fit-out, insulation
Acoustic Design Practices for Sustainable Buildings
Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? Acoustic Design Practices for Sustainable Buildings Danny
MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau
Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments Weiss Klimatechnik GmbH Geräte- und Anlagenbau in use throughout the world Al-Batnan Medical Center, Tobruk System solutions for
products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN
products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A
How To Make A Building Energy Efficient
An Introduction to Chilled Beams and Ceilings July 2012 Version 1 DISCLAIMER All rights reserved. Apart from any fair dealing for the purposes of private study or research allowed under applicable copyright
Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION
Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION photoelectric sensors Thanks to its vision for innovation and technological enhancement, Contrinex keeps on setting new standards
Data Centres A complete solution to noise control and acoustic packages
Data Centres A complete solution to noise control and acoustic packages Introduction World class noise control. Expertise you can trust. IAC Acoustics is world-renowned for providing cost effective solutions
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
Accuracy counts! SENSORS WITH ANALOG OUTPUT
Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection
Comparison between Decentralised and Centralised Air Conditioning Systems
Comparison between De and Centralised Air Conditioning Systems (Summary) FassadenSystemLüftung FassadenSystemLüftung Telephone +49/ 28 45/ 2 02-711 GmbH & Co KG Telefax +49/28 45/2 02-2 25 Heinrich-Trox-Platz
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair
The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended
Federation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu [email protected] Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of
ASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
Brochure More information from http://www.researchandmarkets.com/reports/1339929/
Brochure More information from http://www.researchandmarkets.com/reports/1339929/ The 2011 World Forecasts of Machine Tools That Remove Material by Laser or Light, Photon, Ultrasonic, Electro-Discharge,
Displacement ventilation
General The displacement ventilation principle is the oldest form of ventilation and can be achieved without the use of fans. Air movement occurs by means of the density differences between supply air
SECTION 15936 AIR INLETS AND OUTLETS
SECTION 15936 AIR INLETS AND OUTLETS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers. 3. Grilles. 4. Louvers. 5. Lowered Penthouses. 6. Gravity Roof Hoods. 7. Gravity Roof
sound reduction systems for commercial, educational and industrial environments
sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: [email protected] Web: www.soundreduction.co.uk soundblocker Acoustic
Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer
Fundamentals of Acoustics & Practical HVAC Design Considerations Demir Doken Acoustic Engineer What is sound? Sound is a mechanical wave that is an oscillation of pressure transmitted through some medium
COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS
COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS Risto Kosonen, Panu Mustakallio Arsen Melikov 2, Marcin Duszyk 2 Oy Halton Group Ltd., Helsinki, Finland. 2 International
SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.
SECTION EG Air Distribution Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution. Space Air Diffusion AIR DISTRIBUTION ENGINEERING GUIDE Proper selection of air diffusion
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
Basic Selection & Proper Application of Overhead Air Distribution Devices
Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
Stylish Integration of Linear Diffusers With system solutions and installation details for architects and interior designers
Stylish Integration of Linear Diffusers With system solutions and installation details for architects and interior designers Foto Museum Frie der Burda Types Integrate diffusers unobtrusively in flush,
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE
Modular Data Center Cooling Ultra High Efficiency Oasis Optimum DCIE Oasis Optimum Modular Cooling Compact, Economic, Greener, Ultra High Efficiency Munters Oasis Optimum DCIE data center cooling solution
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
We have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
Mechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
How To Build A Powerline Box Powerline Generator
Quick Reference Guide DYNAMIC Series Dynamic Series is a broad product family that provides connector solutions ranging from signal level circuitry through power circuit connectivity in a ruggedized, industrialized
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
Combi Unit Genius. The energy efficient Building Service Centre
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Combi Unit Genius The energy efficient Building Service Centre systemair Central Building Services
WWW.SMETS-TECHNOLOGY.COM COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH 01. 2013 INNOVATIONS FOR POWERFUL PERFORMANCES
WWW.SMETS-TECHNOLOGY.COM COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH 01. 2013 INNOVATIONS FOR POWERFUL PERFORMANCES COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK PAGE 02 ENGLISH STATUS 01. 2013
Reporting practices for domestic and total debt securities
Last updated: 4 September 2015 Reporting practices for domestic and total debt securities While the BIS debt securities statistics are in principle harmonised with the recommendations in the Handbook on
41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50.
Overall Results Climate Change Performance Index 2012 Table 1 Rank Country Score** Partial Score Tendency Trend Level Policy 1* Rank Country Score** Partial Score Tendency Trend Level Policy 21 - Egypt***
CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design
CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product
plenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.
OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different
LuxeMbOurG Trading CenT re LisT Annex 1 to the special terms and conditions for securities transactions Valid as from 1 september 2011
Luxembourg Annex 1 to the Special terms and conditions for securities transactions Valid as from 1 September 2011 In order to achieve the best possible result in executing security orders, the bank has
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
Energy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could
The compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
World Consumer Income and Expenditure Patterns
World Consumer Income and Expenditure Patterns 2014 14th edi tion Euromonitor International Ltd. 60-61 Britton Street, EC1M 5UX TableTypeID: 30010; ITtableID: 22914 Income Algeria Income Algeria Income
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair systemair Disclose the secret
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
TOP 10 NOISE CONTROL TECHNIQUES
TOP 10 NOISE CONTROL TECHNIQUES The following are 10 simple noise control techniques that have wide application across the whole of industry. In many cases, they will produce substantial noise reductions
HVAC Characteristics. Test Space HVAC Characteristics
HVAC Characteristics Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations,
Glossary of HVAC Terms
Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other
Payments to Overseas banks Things to be aware of
Payments to Overseas banks Things to be aware of Payment can be made to accounts in most countries. If you wish to have your pension paid overseas, the Royal Bank of Scotland (RBS), the Funds bankers,
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
Business Mobile Plans
PRODUCT SOLUTIONS Business Mobile Plans GUERNSEY Whatever the size of your business, we can provide the ideal mobile solution for you. Our tariffs are flexible to suit all kinds of businesses and are designed
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
International Call Services
International Call Services Affordable rates for business calls. Wherever you are in the world. We ve got plenty to say when it comes to staying in touch when you re overseas. We have agreements with 443
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Basics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
Fläkt Woods Building Future
Energy, Expertise and Environment with Fläkt Woods Fläkt Woods Building Future Saving energy in building ventilation You must save 20% on energy before 2020. Following the Kyoto protocol the European Union
PULASKI AND DUBLIN MIDDLE SCHOOLS
PULASKI AND DUBLIN MIDDLE SCHOOLS HVAC/ ELECTRICAL/ WINDOW REPLACEMENT STUDY DUBLIN MIDDLE SCHOOL REPORT BY: PULASKI MIDDLE SCHOOL P.C. Plaza Suite 1 10 Church Avenue SE Roanoke, VA 24011-2104 540.342.6001
How To Design A Room Air Conditioning System
Comparison of HVAC Technology in Buildings Conventional HVAC Technology Bauer Optimising Technology The Differences Room environment (Occupant Comfort) Energy Consumption Architecture Air flows in a room
THE WORLD S LEADING CAR DESIGN MAGAZINE
THE WORLD S LEADING CAR DESIGN MAGAZINE DISTRIBUITED IN MORE THAN 60 COUNTRIES EUROPE: Austria, Belgium, Cyprus, Denmark, Finland, France, Germany, United Kingdom, Greece, Ireland, Iceland, Italy, Latvia,
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Nominal Life Expectancy for Building Components
Nominal Life Expectancy for Building Components Building System Page A. HVAC 2 B. Elevator/Escalator 6 C. Plumbing 7 D. Roofing 8 E. Electrical 10 F. Fire/Life/Safety/Security System 11 G. Interior Finishes
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent