Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server



Similar documents
Communicate and view data from meters with one simple device

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Access valuable energy and power information from your system

Electrical Network Management System

Unite your power network

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

scalable data centre energy management solution

Square D Model 6 Motor Control Centers

Optimize your power network with data-driven decisions

Indoor / Outdoor Antenna

Energy efficiency and cost reduction solutions for industry. PowerLogic application brochure

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Waveguide Access Point WGA631. Product Guide

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Power Meter Series 700

Easily connect your switchboards to facility management solutions

Telephone- and leased line modem for industrial applications TD-36

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

T200, PTP/IEEE 1588 Grandmaster Clock and

StruxureWare Power Monitoring Expert 7.2 Functions and characteristics

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Technology & Evolution

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Power & Environmental Monitoring

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

TX2123 RS485 TO ETHERNET ADAPTOR

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Power quality monitoring and analysis with reliability

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

How To Run An Nport I5000A Device Server

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

securityprobe5es -X20

Application/Connection Examples

Power Solutions for Data Centers Metering and protection architecture guide

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

HWg-STE HWg-STE PoE MANUAL

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation

Quick Connect. quick - simple - efficient.

Rack mounted telephone- and leased line modem for industrial applications

TX OPEN RS232/485 module

Scout 1U Rackmount Computer

Power Meter Series 800

PCS0100en Persy Control Services B.V. Netherlands

Simple Electrical Utility Cost Allocation Solutions

C24-CAMANL Video Server/Encoder

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

StruxureWare Power Monitoring Expert Data Center Edition. Power system intelligence and reliability for your entire infrastructure

ORION TELECOM NETWORKS INC. T1

Personalise energy solutions

securityprobe 5E Standard

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

TK800-Series Industrial GPRS / UMTS / LTE Router

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

My first Hirschmann: The SPIDER family of switches.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Poseidon MANUAL

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Modbus Communications System for Micrologic A, P, and H Trip Units

Datasheet. airmax WISP Customer Wi-Fi Solution. Models: airgateway, airgateway-lr, AMG-PRO. Works Seamlessly with Existing airmax CPE Deployment

Configuring security in ION devices using ION Setup

PowerLogic PowerView Software Restricted to Schneider Personnel. POWERLOGIC PowerView Power Monitoring Software Version 2.

PowerLogic energy & power management systems

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

MAJORSINE Power Inverter

Internet-Accessible Power Monitoring & Control Systems

Broadband Router ESG-103. User s Guide

Tracer Summit Web Server

Chassis, Power Supply, and Element Management

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

IntesisBox Modbus Server Fidelio IP

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Applications. diris_826_a_1_gb_cat

Uninterruptible Power Supply

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Ultra Thin Client TC-401 TC-402. Users s Guide

Job Aid Pre-Installation Information S8500 Media Server

Manage critical infrastructure, energy, revenue, reliability and power quality.

AXIS T81B22 DC 30W Midspan

4-CH Hybrid Digital Video Recorder

Remote Monitoring and REC 501 Control Unit Product Guide

You were seeking a protocol translator. Eaton delivered a vital data flow processor.


WebMeter Internal Web Server Feature

Power Xpert Gateway 800E

UPS Network Interface. Quick InstallationGuide

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Smart-UPS On-Line 230 V

QuickSpecs. HP Compaq t5525 Thin Client. Overview

PowerLogic ION Setup 3.0

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Transcription:

Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server

Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that requires only a web browser and Ethernet network to log and display real-time data and trend plots from up to 64 PowerLogic system devices, including other gateway devices on the same network. An automatic device discovery function quickly detects devices within your electrical network, enabling access to basic energy consumption data. Combine the PowerLogic EGX300 with your existing spreadsheet software for simple energy use analysis and trend reports. For extensive data analysis and additional power monitoring capabilities, utilise the Ethernet gateway functionality of the PowerLogic EGX300 with any PowerLogic software. The PowerLogic EGX300 embedded web page function and 256 Mb of onboard memory allow you to create pages for viewing data from your electrical system and to store third-party web pages and documents such as instruction bulletins or equipment and system diagrams. Easily define web pages with real-time and logged data for a basic view of your electrical system at a glance. Typical applications The PowerLogic EGX300 allows you to: Monitor energy usage patterns, reveal opportunities and verify results of efficiency improvements Remotely monitor real-time conditions and profile energy use on your power distribution system Use enhanced EGX300 communication and realtime reading features to help optimise your energy usage and existing electrical infrastructure. The functionality of the PowerLogic EGX300 flexes as your system grows. It is compatible with PowerLogic power monitoring software for larger systems where comprehensive power monitoring is needed to: Allocate energy costs to departments or processes Reduce peak demand surcharges Reduce power factor penalties Identify billing discrepancies Leverage existing infrastructure capacity and avoid over-building

Features View real-time and historical information from multiple locations via any Microsoft-compatible web browser without any additional software Automatically detect networked devices for easy system setup View and log data from up to 64 devices across the network, even if they are connected to other gateway devices Automatically email or FTP selected logged data to your PC for additional analysis Select the logging intervals and topics you want logged Ensures data and system security through password protection and controlled network access to individual web pages Simplifies installation by receiving control power through the Ethernet cable utilising Power-over-Ethernet and offers the option to utilise 24 Vdc control power Provides serial support for Modbus RTU, Modbus ASCII, Jbus and PowerLogic protocols to support a wide range of devices Includes one 10/100BaseTx Ethernet port Includes one serial port configurable for RS485 (2/4 wire) or RS232 (RJ45) Optically isolated serial port provides highly reliable communications in an industrial environment Compatible with all PowerLogic power monitoring software Electrical distribution system View device data through a simple browser no software needed EGX300 web page Trend plots Data log files EGX300 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) EGX100 ION6200 PM800 MicroLogic Sepam

Communications Use your existing LAN infrastructure to reduce communications wiring and network management costs. Fast 10 or 100 Mb per second Ethernet communications eliminates bottlenecks by moving power monitoring data at the same network speeds used in your LAN. PowerLogic EGX300 Serial ports Number of ports 1 Types of ports Protocol Maximum baud rate Maximum number of connected devices 64 Ethernet port Number of ports 1 Types of ports Protocol Baud rate Web server RS232 or RS485 (2-wire or 4-wire), depending on setting Modbus RTU/ASCII, JBus, PowerLogic (Sy/Max) 2400 to 38400 baud (configurable) One 10/100 base TX (802.3af) HTTP, SNMP (MIB2), FTP Modbus TCP/IP 10/100 MB PowerLogic EGX300 offers an RS232 or RS485 serial port. Memory 256 MB Simultaneous connections 64 Web pages The PowerLogic EGX300 embedded web page function allows users to create pages for viewing data from meters, circuit breaker control units, protective relays, motor controllers and drives. Standard pages are provided for communications network maintenance. Its extensive onboard memory makes the PowerLogic EGX300 versatile to fit many unique needs and open to additional user customisation. Use energy consumption trend reports to identify energy use patterns for cost savings opportunities.

Automatically email or FTP selected logged data to your PC for additional analysis. Quickly obtain real-time data from your electrical distribution system to view status of equipment per device or to analyse summary views of critical circuits. Customise device names for easy recognition.

Specifications EGX300 Regulatory/standards compliance for electromagnetic interference Emissions (radiated and conducted) Immunity for industrial environments: - electrostatic discharge - radiated RF - electrical fast transients - surge - conducted RF - power frequency - magnetic field EN 55022 / EN 55011/ FCC class A EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Regulatory/standards compliance for safety International (CB scheme) IEC 60950 USA Canada UL508/UL60950 cul (complies with CSA C22.2, no. 60950) Enhance your PowerLogic solution Support or expand your PowerLogic solution with matched accessories and complementary products or systems. The PowerLogic EGX300 communicates with these Schneider Electric products and with third-party products through industry-standard Modbus protocol. PowerLogic meters Power, energy and power quality meters for improved energy management, allocation and reliabilty. Altivar variable frequency drives Match motor output to required loads to reduce energy consumption and extend motor life. Tesys motor controllers Motor branch short-circuit protection, manual disconnect, remote power circuit switching and thermal overload protection. Sepam protective relays Monitoring, protection and control of substations, busbars, transformers, motors, generators and capacitors. Masterpact and Compact breakers Equipped with Micrologic control units, offering protection for LV networks. Europe EN 60950 Australia/New Zealand AS/NZS25 60950 Installation options Mounting options Physical characteristics Dimensions (H x W x D) Din-rail mount 91 x 72 x 68 mm Power-over-Ethernet Class 3 Power supply 24 V DC if not using Power-over-Ethernet Services Our extensive engineering and support services ensure you leverage the full capabilities of your PowerLogic solution and benefit from a low total cost of ownership. Our experts can help with system selection, project management, integration, custom reporting, documentation and training to meet your organisation s unique needs. Maximum burden Operating temperature Humidity rating 4 Watts -25 C to +70 C 5% to 95% relative humidity (without condensation) at +55 C Please contact your local sales representative for ordering information. Visit www.powerlogic.com for more information on other PowerLogic products, applications and system solutions. Schneider Electric 35 Rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex Tel : +33 (0)1 41 29 70 00 Fax : +33 (0)1 41 29 71 00 www.powerlogic.com www.schneider-electric.com PLSED108052EN ART#836684 12-2008 2008 - Schneider Electric - All rights reserved As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication. PowerLogic, ION, ION Enterprise, MeterM@il and Modbus are either trademarks or registered trademarks of Schneider Electric. Printed on recycled paper Publishing : Schneider Electric Production : Schneider Electric PMC Printing : Imprimerie du Pont de Claix - made in France