Protection is Central. Twin Cities East Data Center House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data Center is nothing less than a concrete bunker protected by earthen berms. The position it holds makes it defiant against flood, storm, attack, and prying eyes. With redundancy built into both security and infrastructure support, chances are your data will outlast everything else. While exceedingly protected, the 85,000 square foot facility also provides the highest level of flexibility anywhere: build exactly what you need and we will keep it safe. Amenities Overview Facility 85,000 sq ft Facility Purpose-built, bunkered, single-level building with high wind-rating 14 to 28 clear height Loading Two (2) loading docks with staging & storage areas Other Energy-efficient follow-me lighting available in dedicated suites Potential for Minnesota Data Center Sales Tax Exemption (on software, hardware, power, etc) Priority diesel fuel delivery contracts Management On-site management & engineers Amenities Shared conference center Shared kitchen & break room Dedicated office space available Shared office space available Showers
Power Electrical N+1 or 2N topology 50 to 250 watts per sq.ft. (2 to 15 kw per rack averages) Cooling N+1 of 2N topology Customer option of: In-row/overhead + containment CRAC (2 to 3 raised floor) Kyoto Custom Fire Protection Dedicated Suite customer option of: Wet-pipe VESDA Pre-action Gaseous Sub #1 Sub #2 Concurrently-maintained substation Up to 65 MW (medium voltage w/ on-site transforming) Utility paralleling Self-healing grid Available for 500+kW Customer Up to 13 MW (medium voltage w/ on-site transforming) Utility paralleling Connectivity Carrier-neutral Two (2) meet-me rooms Abundance of dark fiber available Diverse site & building entry
Security Implements 1. Military-grade vehicle crash barriers and gates 2. Entry man-traps with advanced sensory technologies 3. Three (3) zones of man-containment 4. 24 7 manned security 5. Bullet-resistant glass throughout 6. Video surveillance throughout buildings & site with on-site and off-site monitoring 7. Advanced sensory-surveillance technologies throughout 8. Local law enforcement and SWAT team coordination 9. Biometrics + keycard + code access requirements 7 C 9 4 6 2 5 6 6 1 Disaster Avoidance Not in 500 year floodplain Not in proximity to railroads, chemical plants, airport takeoff/landing zones Earth-bermed & bunkered for wind/tornado mitigation A
Availabilities Single cabinet to multi-megawatt deployments 50 to 250 watts per sq.ft. N+1 or 2N electrical N+1 or 2N mechanical Shared Space & Shared Infrastructure Concurrently-maintainable electrical and mechanical systems 150 sq ft to 500 sq ft Cages Lockable Racks Half and Quarter Racks Occupancy Lead Times Dedicated space + dedicated infrastructure = 90 days for signing Dedicated space + shared infrastructure =100 days from signing Shared space + shared infrastructure = 30 days from signing Suite Space Power Support A (LEASED) 5000 sq ft 1.25 MW of Power 2N Electrical & N+1 Mechanical Systems B Up to 35000 sq ft Up to 9 MW of power Build-to-Suit Electrical & Mechanical Systems C 7500 sq ft Up to 2 MW of Power Build-to-Suit Electrical & Mechanical Systems D 5000 sq ft Up to 1.5 MW of Power Build-to-Suit Electrical & Mechanical Systems E 2000 sq ft Up to 500kW of Power Build-to-Suit Electrical & Mechanical Systems F 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems G 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems
Twin Cities West Data Center With redundancy built into both security and infrastructure support, chances are your data will outlast everything else. While exceedingly protected, the 30,000 square foot facility also provides the highest level of flexibility anywhere: build exactly what you need and we will keep it safe. Amenities Overview Power & Connectivity Facility 30,000 sq ft of data center space 14 foot clear height in data center Concrete construction in data center Loading Two (2) loading docks with staging & storage areas Electrical Utility territory of Xcel Energy 4 MW available Scalable, modular design up to 250 watts per square foot Management On-site management & engineers Amenities Office space and turn-key disaster recovery office space available Fiber Carrier-neutral Dark fiber available Diverse site & building entry Cooling N+1 of 2N topology Security Disaster Avoidance Not within the 200 year flood plain Not in proximity of railroad tracks Not under take-off, landing or flight pattern of any airport Not in proximity to any chemical plants or prospective terrorist targets Security Implements Concrete construction in data center Subterranean data center
Availabilities Independently demised space for each tenant and shared space available Exclusive infrastructure and shared infrastructure available Shared Space & Shared Infrastructure Concurrently-maintainable electrical and mechanical systems Availabilities 150 sq ft to2,000 sq ft Cages Lockable Racks Half and Quarter Racks Occupancy Lead Times Dedicated space + dedicated infrastructure = 90 days for signing Dedicated space + shared infrastructure =100 days from signing Shared space + shared infrastructure = 30 days from signing Suite Space Power Support SUITE 100 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems SUITE 101 2500 sq ft Up to 250kW of power Build-to-Suit Electrical & Mechanical Systems SUITE 102 5000 sq ft Up to 250kW of power Build-to-Suit Electrical & Mechanical Systems