House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data

Similar documents
OPERATOR - FACILITY ADDRESS - DATE

VOLICO. Colocation Hosting. Enterprise Hosting Solutions

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

VOLICO. Colocation Checklist. Key Data Center Evaluation Criteria

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

Santa Clara, CA 95054

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

Wholesale Data Center Suites Available Now

Tier IV Enterprise - Class Data Center

RAGINGWIRE. THE WORLD S MOST TECHNOLOGICALLY ADVANCED DATA CENTERS!

THE MULTI-TENANT DATA CENTER

How To Build A Data Center For Ragingwire

Chicago 1 (CHI-1) Data Center

Subject: County of Los Angeles Data Center Space Requirement

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

World-Class Data Centers, Colocation, Cloud & Management Services. Central and Southern Oregon Locations East and West of the Cascade Divide

215 W. Ohio St. 5th Floor Chicago, IL Enterprise-Class Security, Performance and Redundancy

White paper. SAS Solutions OnDemand Hosting Overview

How To Visit An Internet Data Center

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

N O W A V A I L A B L E

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

19 Site Location, Design and Attributes. Site Location, Design and Attributes

Global Data Center & Colocation Facilities

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

Data Centre Barrie, Ontario

Developing a Shared Business Continuity Data Center

Data Center Co- Location

Data Center:Build-to-Suit

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

TELEDATA DATA CENTRE AND COLOCATION SERVICES IN MANCHESTER

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Datacentre Reading East 2 Data sheet

CASE STUDY. FuelQuest, Inc. Achieves 100% Uptime for their Cloud-Based Fuel Inventory and Tax Solutions at CyrusOne s Data Center

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Why Choose Go4Hosting Data Center?

High-performance. High-density. Highly committed. Built for tomorrow. Ready today.

CASE STUDY. FuelQuest, Inc. Achieves 100% Uptime for their Cloud-Based Fuel Inventory and Tax Solutions at CyrusOne s Data Center

SYSTRUST CERTIFICATION REPORT FOR COLLOCATION AND DATA CENTER HOSTING SERVICES FOR THE PERIOD FROM JANUARY 1, 2013 TO DECEMBER 31, 2013

MINNEAPOLIS MARKET STREAM PRIVATE DATA CENTER CHASKA, MINNESOTA Ross Avenue, Suite 2800 Dallas, Texas 75201

High-performance. High-density. Highly committed.

X-tier Data Facility. Prepared by X-tier SAE Corporation

ISOMEDIA COLOCATION

At Cavern Technologies, our goal is to meet and exceed our clients diverse requirements for IT infrastructure services.

Colocation Buyer s Guide and Checklist. A Playbook for Technology Managers

NY2 21 CRITICAL MEGAWATTS 280,000 SQUARE FEET

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Datacenter Assessment

Secure I Reliable I Flexible

Brought to you by. Colocation Solutions BROUGHT TO YOU BY.

March/April Tour the. PhoenixNAP. See Inside.

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Datacentre Maidenhead P1 Data sheet

World-Class Greenf ield EMP Facilities Max Resilient Infrastructure

Midwest s Premier Carrier Neutral Colocation Data Center Greater Minneapolis St. Paul, Minnesota

Data Center CH1. Elk Grove Village, IL

CyrusOne Global Data Center Solutions

POWERING A CONNECTED ASIA. Pacnet Hong Kong CloudSpace1 Technical Specifications. Asia s Pioneering Facility with Direct Subsea Cable Access

Data Centre Infrastructure

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

data center - why choose a data center facility

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

STREAM PRIVATE DATA CENTER SAN ANTONIO MARKET WESTOVER HILLS Ross Avenue, Suite 2800 Dallas, Texas

World s Greenest High Performance Data Center

DATACENTER BERLIN Definitely a Good Perspective

EVALUATING DATA CENTER AND COLOCATION HIGH-AVAILABILITY SERVICE DELIVERY. A FORTRUST White Paper. March,

LDeX Group. Colocation Solutions for High Expectations

7 Best Practices for Buying Colocation:

disaster recovery - the importance of having a plan

CHICAGO S PREMIERE DATA CENTER

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Datacenter Hosting and Cloud Computing Services

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

colocation. perfected. Overview

THE SIS MANAGED SOLUTION CENTER

Datacentre South London Data sheet

Introduction of China Telecom Data Center. Your Connection to Asia Starts Here

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

High Performance Computing (HPC) Solutions in High Density Data Centers

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Experience Matters...

Strategic Data Centre Site Profiles Data Centre Co-Location London North

9,940 SF Office Building

T5 CHARLOTTE REGION WEST DATA CENTER PARK

Nirvanix, Inc. Finds a Secure and Reliable Data Center and a Strategic Partner for Cloud Services at CyrusOne

A Sustainable, Master-Planned Data Center Park.

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Enabling an agile Data Centre in a (Fr)agile market

1301 Fannin. Houston Data Center & Office Facility

Pacnet Hong Kong CloudSpace2 Technical Specifications. Upholding the Principles of Efficiency and Sustainability in Data Center Design

Evaluating Datacenter Colocation

CASE STUDY. Nirvanix, Inc. Finds a Secure and Reliable Data Center and a Strategic Partner for Cloud Services at CyrusOne

Secure I Reliable I Flexible COPT DC Hornbaker Road, Manassas, Virginia

Transcription:

Protection is Central. Twin Cities East Data Center House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data Center is nothing less than a concrete bunker protected by earthen berms. The position it holds makes it defiant against flood, storm, attack, and prying eyes. With redundancy built into both security and infrastructure support, chances are your data will outlast everything else. While exceedingly protected, the 85,000 square foot facility also provides the highest level of flexibility anywhere: build exactly what you need and we will keep it safe. Amenities Overview Facility 85,000 sq ft Facility Purpose-built, bunkered, single-level building with high wind-rating 14 to 28 clear height Loading Two (2) loading docks with staging & storage areas Other Energy-efficient follow-me lighting available in dedicated suites Potential for Minnesota Data Center Sales Tax Exemption (on software, hardware, power, etc) Priority diesel fuel delivery contracts Management On-site management & engineers Amenities Shared conference center Shared kitchen & break room Dedicated office space available Shared office space available Showers

Power Electrical N+1 or 2N topology 50 to 250 watts per sq.ft. (2 to 15 kw per rack averages) Cooling N+1 of 2N topology Customer option of: In-row/overhead + containment CRAC (2 to 3 raised floor) Kyoto Custom Fire Protection Dedicated Suite customer option of: Wet-pipe VESDA Pre-action Gaseous Sub #1 Sub #2 Concurrently-maintained substation Up to 65 MW (medium voltage w/ on-site transforming) Utility paralleling Self-healing grid Available for 500+kW Customer Up to 13 MW (medium voltage w/ on-site transforming) Utility paralleling Connectivity Carrier-neutral Two (2) meet-me rooms Abundance of dark fiber available Diverse site & building entry

Security Implements 1. Military-grade vehicle crash barriers and gates 2. Entry man-traps with advanced sensory technologies 3. Three (3) zones of man-containment 4. 24 7 manned security 5. Bullet-resistant glass throughout 6. Video surveillance throughout buildings & site with on-site and off-site monitoring 7. Advanced sensory-surveillance technologies throughout 8. Local law enforcement and SWAT team coordination 9. Biometrics + keycard + code access requirements 7 C 9 4 6 2 5 6 6 1 Disaster Avoidance Not in 500 year floodplain Not in proximity to railroads, chemical plants, airport takeoff/landing zones Earth-bermed & bunkered for wind/tornado mitigation A

Availabilities Single cabinet to multi-megawatt deployments 50 to 250 watts per sq.ft. N+1 or 2N electrical N+1 or 2N mechanical Shared Space & Shared Infrastructure Concurrently-maintainable electrical and mechanical systems 150 sq ft to 500 sq ft Cages Lockable Racks Half and Quarter Racks Occupancy Lead Times Dedicated space + dedicated infrastructure = 90 days for signing Dedicated space + shared infrastructure =100 days from signing Shared space + shared infrastructure = 30 days from signing Suite Space Power Support A (LEASED) 5000 sq ft 1.25 MW of Power 2N Electrical & N+1 Mechanical Systems B Up to 35000 sq ft Up to 9 MW of power Build-to-Suit Electrical & Mechanical Systems C 7500 sq ft Up to 2 MW of Power Build-to-Suit Electrical & Mechanical Systems D 5000 sq ft Up to 1.5 MW of Power Build-to-Suit Electrical & Mechanical Systems E 2000 sq ft Up to 500kW of Power Build-to-Suit Electrical & Mechanical Systems F 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems G 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems

Twin Cities West Data Center With redundancy built into both security and infrastructure support, chances are your data will outlast everything else. While exceedingly protected, the 30,000 square foot facility also provides the highest level of flexibility anywhere: build exactly what you need and we will keep it safe. Amenities Overview Power & Connectivity Facility 30,000 sq ft of data center space 14 foot clear height in data center Concrete construction in data center Loading Two (2) loading docks with staging & storage areas Electrical Utility territory of Xcel Energy 4 MW available Scalable, modular design up to 250 watts per square foot Management On-site management & engineers Amenities Office space and turn-key disaster recovery office space available Fiber Carrier-neutral Dark fiber available Diverse site & building entry Cooling N+1 of 2N topology Security Disaster Avoidance Not within the 200 year flood plain Not in proximity of railroad tracks Not under take-off, landing or flight pattern of any airport Not in proximity to any chemical plants or prospective terrorist targets Security Implements Concrete construction in data center Subterranean data center

Availabilities Independently demised space for each tenant and shared space available Exclusive infrastructure and shared infrastructure available Shared Space & Shared Infrastructure Concurrently-maintainable electrical and mechanical systems Availabilities 150 sq ft to2,000 sq ft Cages Lockable Racks Half and Quarter Racks Occupancy Lead Times Dedicated space + dedicated infrastructure = 90 days for signing Dedicated space + shared infrastructure =100 days from signing Shared space + shared infrastructure = 30 days from signing Suite Space Power Support SUITE 100 1000 sq ft Up to 250kW of Power Build-to-Suit Electrical & Mechanical Systems SUITE 101 2500 sq ft Up to 250kW of power Build-to-Suit Electrical & Mechanical Systems SUITE 102 5000 sq ft Up to 250kW of power Build-to-Suit Electrical & Mechanical Systems