Total Solutions Verification



Similar documents
Enhanced Category 5 Cabling System Engineering for Performance

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

IT Cabling Solutions

SYSTIMAX Copper Solutions Designed for the Digital Generation

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Gigabit Ethernet on Copper Cabling Infrastructures

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

How to Choose the Right Cable Category

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Copper Patch Cords. Impact On Network Performance and Reliability

Category 6 UTP - Cabling System

GigaSPEED X10D Solution How

Data Communications Competence Center

Category-6 / Class-E Cabling

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Impedance Matching. Throughput SOLUTIONS NETWORK PERFORMANCE. Only the TrueNet Impedance-matched System Protects Network Performance

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Safety & Performance in the Wire and Cable Industry

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

The High Cost of a Low-Cost Cable Certification Tester

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Cabling for 10GBASE-T and Beyond - A Tangled Web

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Uniprise Solutions. Ten Good Reasons To Choose CommScope.

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

B. PART 1 - GENERAL of SECTION BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

WHITE PAPER December, 2001

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

White Paper. Crestron 8G DigitalMedia Cable

Network Design. Yiannos Mylonas

Cable Assemblies. Features and Benefits

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

10 Gigabit Ethernet over copper: Unshielded, unprotected?

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Obsolete Fiber Technology? Not in my Data Center!

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

How To Get A Better Signal From A Fiber To A Coax Cable

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Implementing Fast Ethernet

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

Cat 6 Cable: Copper s Last Stand? Cat 6 Cable is craft intensive! Advanced Installation & service skills are a MUST.

CommScope Intelligent Building Infrastructure Solutions (IBIS)

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Specification SFTP CAT6 Network Cable 23AWG CU

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. Slide Number 1

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Copper Cabling Troubleshooting Handbook

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning

Category 6 Cabling Questions and Answers

Innovative Connectivity Solution for Maximum Performance and Security

InstaPATCH Cu Cabling Solutions for Data Centers

LS Data Communication Product

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Data Center Design for 40/100G

Ethernet/IEEE evolution

Cabling and Building Infrastructure for Technology

Communication, Signal & Data Cables

SMARTen 24 UTP Patch Panels

De-Mystifying Cabling Specifications

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

Gigabit Switching Ethernet Media Converters - Product User Guide

Overcoming OM3 Performance Challenges

Network Engineers Everywhere:

Advantages of 4 th Generation CAT 6A UTP Cables. Antonio Cartagena Business Development - Caribbean Leviton Network Solutions

Upgrading Path to High Speed Fiber Optic Networks

Cabling Standards Update 2014

with Component Rating A Simple Perspective

Data Centre & Enterprise Solutions. RapidNet

Transcription:

Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions

CommScope has always designed cables with connectivity in mind. Our engineers fully realize that cable is just one part of a total communications system, and that cable and connectivity components must fit and work well together to deliver on the promise of a high-bandwidth data communications system. This is why CommScope cables (and their high margins in performance) bring out the best in many connectivity components. This is especially true for our Uniprise connectivity solutions. Our stated aim is to produce solutions that exceed the operating standards for which they are designed. To accomplish this, our design engineers work closely with component manufacturers and installers and actively use their feedback in our product design and manufacturing. Testing to exceed the standard Popular standards (such as the EIA/TIA categories of twisted pair cable and components) define performance baselines, which are confirmed by independent testing firms such as Intertek ETL SEMKO or Underwriters Laboratories (UL). However, CommScope has developed test procedures that go well beyond the industry standards. For instance, industry standards require that every batch of cable be tested and the size of a batch cannot exceed 250,000 ft; CommScope tests in much smaller batches (about 1/5th of the industry standard maximum). WebTrak No. Footage Marker By using proprietary tools such as a customized SAS database that allows us to track and predict manufacturing trends, we continually improve our manufacturing processes so as to make a superior product every time. The WebTrak TM test reports we provide for our UTP products are a byproduct of this system. WebTrak TM permits on-line access to detailed test data for most CommScope UTP cables. WebTrak identification numbers are printed on the jacket so they cannot be lost or misplaced. CommScope provides this as a free service; most other manufacturers, if they offer it at all, charge a fee for test reports. Living up to the promise Any cable manufacturer can claim that their products meet or exceed a standard, but CommScope was the first to prove it using 3rd party testing. In 01, we created the "Cable Only Verification" program and contracted noted independent testing 70 ACR firm ETL SEMKO to verify that our cables meet not just standards, but advertised performance levels. For example, our Ultra II cable (part number 5504M/55N4R) is advertised as a Category 5e "plus" product with a bandwidth of 350 MHz. "Cable Only" Verification means that the cable is tested for attenuation (insertion loss), crosstalk (near end and far end, both pair-to-pair and powersum), and return loss, etc. up to 350 MHz, which is well above the 0 MHz standard. 60 50 db/0m 40 30 0 0 50 0 150 0 250 300 350 Ultra II Insertion Loss Ultra II NEXT Frequency (MHz) Cat 5e Insertion Loss Cat 5e NEXT

3rd Party Tested vs. 3rd Party Verified - What's the difference? The term "3rd party" simply means someone other than the manufacturer or customer has evaluated the product. Technically, anyone with the right test equipment can test a cable or solution. However, preferred practice is to use a recognized testing laboratory such as ETL SEMKO or UL for 3rd party testing. Both ETL SEMKO and UL are certified by OSHA and are Nationally Recognized Test Laboratories (NRTLs). There is, however, a very big difference between 3rd party tested and 3rd party verified. While 3rd party testing sounds like a thorough and independent evaluation, it is not as strict or as thorough as it sounds. In 3rd party testing, the manufacturer selects the sample - they choose the product(s) (cable, connectors, or solution) to be tested, the size of the test sample and the specifications for which the product(s) will be tested. In the majority of cases, a product that is 3rd party tested is a single sample. Also, the test is performed once; there is no follow-up to see if the results are the same a few months later or even for a different 'batch.' The details of Total Solutions Verification In TSV, the manufacturer may supply initial test samples, but ALL of the samples in the final testing will be randomly selected. TSV also dictates sample size and quantity (a minimum of three samples) and the test criteria (in the case of the CommScope Uniprise TSV the solutions are tested to the advertised Uniprise performance specifications). Another important aspect of TSV is that it is ongoing. Along with an audit of the manufacturing facility, TSV calls for quarterly follow-up testing. A verified solution is issued a verification certificate upon successful completion of both initial and final testing. Only solutions that are in a verification program are issued a certificate of conformance. ETL SEMKO, which performs verification for Uniprise solutions for CommScope, lists verification certificates in a product directory. Verification certificates may be found at the ETL SEMKO website at: http://www.intertek-etlsemko.com/portal/page?_pageid= 34,61337&_dad=cust_portal&_schema=CUST_PORTAL CommScope submits its solutions (cable and connectivity) for 3rd party verification. We call our version of this 'Total Solutions Verification' (TSV) and it is a much more stringent process than 3rd party testing, as noted in the table below. Important facts to understand about products advertised as 3rd party tested: This is a One time test Sample selection criteria dictated by the manufacturer Sample size dictated by the manufacturer Test specification dictated by the manufacturer Important facts to understand about products advertised as 3rd party verified: It is a Continuous Program Initial test samples may be supplied by the manufacturer Sample size dictated by the program (Total Solutions Verification (TSV) is 3 samples minimum) Test specification are dictated by the program (TSV uses the advertised Uniprise TM performance specifications) Audit of Manufacturing facility required Final testing is a repeat of the initial testing where all samples are independently selected Follow-up testing as dictated by the program (TSV is quarterly) Verification Certificates are only issued for products that pass all the testing criteria Use of Verified Logo is authorized for products or solutions that are issued a verification certificate. The Uniprise TSV program is considered by many to be the most comprehensive 3rd party verification program in the industry today. This is because the TSV goes beyond testing the cable; it evaluates ten different "solutions" with material from no less than three different batches. These solutions include two permanent link configurations: 2 Connector (TIA Permanent Link ISO/IEC CP) and 3 Connector (ISO/IEC Permanent Link) and three channel configurations: 3 Connector, 4 Connector and 6 Connector Each configuration is tested in a 'short' version (Approximately 30 meters) and a 'long' version (90 meters for permanent link and approximately 0 meters for channel). For a total of ten tested configurations.

Short Permanent Link Configurations Two Connector 3 30 3 3 30 3 Short Channel Configurations 3 1 Four Connector 3 15 5 1 Six Connector 3 15 5 3 1 Long Permanent Link Configurations Two Connector 3 90 3 3 70 3 Long Channel Configurations 3 70 1 Four Connector 3 50 1 Six Connector 3 50 3 1 Legend 1 Meter Patch Cord Modular Jack 3 Meter Patch Cord Patch Panel Horizontal Cable 1 Cross-Connect

Thus, for a single product to be listed within the Uniprise TSV program, a total of 60 different tests (30 initial, 30 final) must be completed successfully. Additionally, to maintain a solution within the TSV program, ongoing quarterly testing is required. In the initial testing phase, CommScope sends samples to ETL SEMKO for testing according to the CommScope Program Procedural Guide and reports the results to CommScope. But in the final and quarterly testing phases, ETL SEMKO randomly selects the samples from either CommScope manufacturing facilities or their distributors and tests them according to the CommScope Program Procedural Guide. ETL SEMKO then reports the results to CommScope. TSV Procedure Initial Testing This is a One time test CommScope Sends Samples to ETL SEMKO for Testing ETL SEMKO Tests Samples according to the CommScope Program Procedural Guide ETL SEMKO Reports Back to CommScope Pass/Fail Final & Quarterly Testing ETL SEMKO Selects Samples Independently From either CommScope facilities or distribution and Isolates them ETL SEMKO Sends Samples Back to The Lab ETL SEMKO Tests Samples according to the CommScope Program Procedural Guide ETL SEMKO Reports Back to CommScope Pass/Fail Category 5e Solutions DataPipe TM Category 5e Solution Category 5e was developed for simultaneous bi-directional transmission over 4-pairs. Improvements to Category 5 were made and additional electrical requirements such as power sum NEXT, equal level far-end crosstalk, power sum equal level farend crosstalk, and return loss were added to create the 5e specification. Typical applications include encoding schemes such as BaseT and 0BaseT Ultra II TM Category 5e "PLUS" Solution The Ultra II family was designed with the future in mind. An Enhanced Category 5e UTP solution that provides guaranteed "headroom" over today's current 5e standards. Ultra II incorporated superior isolation and return loss with low insertion loss and <15ns in Delay Skew. Typical applications include highspeed digital voice and data such as gigabit Ethernet and 155/622 Mb/s ATM. DataPipe 0 MHz Margin to Cat 5e Insertion Loss 23.5 db 2% NEXT 32.1 db 2.0 db Power Sum NEXT 29.1 db 2.0 db ACR 8.6 db 2.5 db Power Sum ACR 5.6 db 2.5 db ELFEXT 19.4 db 2.0 db Power Sum ELFEXT 16.4 db 2.0 db Return Loss 12.0 db 2.0 db Ultra II 0 MHz 155 MHz Margin to Cat 5e Insertion Loss 22.1 db 28.2 db 8% NEXT 34.1 db 30.8 db 4.0 db Power Sum NEXT 32.6 db 29.3 db 5.5 db ACR 12.0 db 2.6 db 5.9 db Power Sum ACR.5 db 1.1 db 7.4 db ELFEXT 22.9 db 19.1 db 5.5 db Power Sum ELFEXT 19.9 db 16.1 db 5.5 db Return Loss 13.0 db 11.1 db 3.0 db

AB 10 CommScope Place SE Hickory, NC 28602 P: 800.544.1948 828.459.5000 F: 828.459.5099 www.uniprisesolutions.com Category 6 Solutions UltraMedia TM Category 6e Solution UltraMedia is designed to exceed all Category 6 requirements for high-speed, full-duplex parallel transmission protocols. The revolutionary patented IsolatorTM maximizes pair separation and minimizes pair motion resulting in superior NEXT, ELFEXT, and RL performance. Typical applications include high-speed digital voice, video and data, such as 3D imaging, broadband video, gigabit Ethernet, and 155/622Mb/s ATM. UltraPipe TM Category 6E Solution UltraPipe is the next evolution in unshielded twisted pair products and exceeds Category 6 specifications. UltraPipe provides superior bandwidth performance to support broadband video, highspeed, full duplex transmission protocols, 3D imaging, gigabit Ethernet, and 155/622Mb/s ATM. UltraMedia 0 MHz 0 MHz 250 MHz Margin to Cat 6 Insertion Loss.2 db 29.9 db 34.1 db 5% NEXT 41.9 db 36.8 db 35.1 db 2.0 db Power Sum NEXT 41.1 db 35.9 db 34.2 db 4.0 db ACR 21.7 db 6.9 db 1.0 db 3.8 db Power Sum ACR.9 db 6.0 db 0.1 db 5.8 db ELFEXT 27.3 db 21.2 db 19.3 db 4.0 db Power Sum ELFEXT 27.3 db 21.2 db 19.3 db 7.0 db Return Loss 15.0 db 12.0 db 11.0 db 3.0 db UltraPipe 0 MHz 0 MHz 250 MHz Margin to Cat 6 Insertion Loss 19.6 db 29.0 db 33.0 db 8% NEXT 42.9 db 37.8 db 36.1 db 3.0 db Power Sum NEXT 42.1 db 36.9 db 35.2 db 5.0 db ACR 23.3 db 8.8 db 3.1 db 5.9 db Power Sum ACR 22.5 db 7.9 db 2.2 db 7.9 db ELFEXT 29.3 db 23.2 db 21.3 db 6.0 db Power Sum ELFEXT 27.3 db 21.2 db 19.3 db 7.0 db Return Loss 16.0 db 13.0 db 12.0 db 4.0 db 05 CommScope Inc. All Rights Reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. 04/05