Optical laser beam scanner lens relay system



Similar documents
A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Theremino System Theremino Spectrometer Technology

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

View of ΣIGMA TM (Ref. 1)

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Hunting Ghosts. For the development of imaging optical STRAY LIGHT ANALYSIS IN IMAGING OPTICS

NOVEL FOCUSING OPTICS FOR IR LASERS Paper 1504

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Experimental and modeling studies of imaging with curvilinear electronic eye cameras

Diffraction of Laser Light

Synthetic Sensing: Proximity / Distance Sensors

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

The Wide Field Cassegrain: Exploring Solution Space

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Types of 3D Scanners and 3D Scanning Technologies.

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

4. CAMERA ADJUSTMENTS

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Applications of confocal fluorescence microscopy in biological sciences

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Refractors Give the Best Planetary Images

TECNOTTICA CONSONNI SRL CERTIFIED QUALITY MANAGEMENT SYSTEM COMPANY BY DNV UNI EN ISO 9001:2008

Grazing incidence wavefront sensing and verification of X-ray optics performance

Lecture 12: Cameras and Geometry. CAP 5415 Fall 2010

SafetyScan Lens. User Manual

Interference. Physics 102 Workshop #3. General Instructions

Optical Systems Design with Zemax OpticStudio. Lecture 1

Diffraction of a Circular Aperture

Optical Storage Technology. Optical Disc Storage

Physics 30 Worksheet # 14: Michelson Experiment

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Optical Modeling of the RIT-Yale Tip-Tilt Speckle Imager Plus

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Telescope Types by Keith Beadman

Near-field scanning optical microscopy (SNOM)

Laue lens for Nuclear Medicine

Recommended alignment procedure for Shaper 6_6 / Focal- Shaper 9

Basic Optics System OS-8515C

Rodenstock Photo Optics

Study Guide for Exam on Light

Buying Your First Telescope By Mike Usher

Polarization of Light

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

Imaging techniques with refractive beam shaping optics

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

A Guide to Acousto-Optic Modulators

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

ID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Rodenstock Photo Optics

LASER TO FIBER SOURCE COUPLERS APPLICATION NOTES

Laser expander design of highly efficient Blu-ray disc pickup head

Color holographic 3D display unit with aperture field division

Physics 116. Nov 4, Session 22 Review: ray optics. R. J. Wilkes

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie

Contents. Introduction 2. Features and Benefits 3. Freeform Design Range 10. Custom 14/16/ Custom U 15. Custom V 17.

Preface Light Microscopy X-ray Diffraction Methods

Optical System Design

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Lenses and Apertures of A TEM

LASER ENGRAVING REFLECTIVE METALS TO CREATE SCANNER READABLE BARCODES Paper P516

Shrinkage Modeling of Injection Molded Precision Optics

Forensic Science: The Basics. Microscopy

Understanding astigmatism Spring 2003

RAY TRACING UNIFIED FIELD TRACING

The Basics of Scanning Electron Microscopy

Diffractive Optical Elements (DOE) for FLEXPOINT Laser Modules

One example: Michelson interferometer

Example of SOP for IR Laser

Alignment Laser System.

5.3 Cell Phone Camera

Anamorphic imaging with three mirrors: a survey

Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter

Introduction to Optics

digital quality control fail pass at your fingertips Smart Metrology Solutions.

Physics 441/2: Transmission Electron Microscope

Light and its effects

Single Mode Fiber Lasers

Physics 25 Exam 3 November 3, 2009

Single Photon Counting Module COUNT -Series

EFFICIENT USE OF SHORT PULSE WIDTH LASER FOR MAXIMUM MATERIAL REMOVAL RATE Paper# M602

Alignement of a ring cavity laser

Teacher s Resource. 2. The student will see the images reversed left to right.

How To Fuse A Point Cloud With A Laser And Image Data From A Pointcloud

Measuring the Point Spread Function of a Fluorescence Microscope

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Simplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market

Using light scattering method to find The surface tension of water

Ultra-fast two-photon microscopy for in vivo brain imaging. Ulrich Leischner

Transcription:

1. Introduction Optical laser beam scanner lens relay system Laser beam scanning is used most often by far in confocal microscopes. There are many ways by which a laser beam can be scanned across the back focal plane of an objective lens, but in general, the most popular ways utilise a tube lens and a scan lens. A beam scanning arrangement is placed in back focal plane of the scan lens, generally consisting of at least one mirror mounted on a galvanometer driver. As the mirror rotates, the angle of incidence of the resulting collimated beam varies at the back focal plane and this causes a diffraction-limited spot to move in the objective s focal plane Scan mirror Scan lens Tube lens Objective Excitation laser beam/fluorescence emission beam Image plane Figure 1. A standard microscope laser beam scanning optical arrangement Such an arrangement is shown n Figure 1. A 160-200 mm focal length tube lens is typically used in conjunction with a short focal length scan lens, typically 25-35 mm focal length. Since the back aperture of most modern objectives is of the order of 15-25mm maximum, this dictates the laser beam diameter in this afocal arrangement; assuming 200 mm fl and 30 mm fl tube and scan lenses, the beam diameter should be 3 mm diameter for a 20 mm back aperture. A relatively short optical system is thus produced and very often microscope eyepieces are used in reverse as scan lenses. If a longer focal length scan lens is used, the laser beam diameter must be proportionately increased and the scan angle before the scan lens can be reduced. In some cases this can be advantageous because of the reduced scan angles, placing fewer constraints on the scanner mirror drive system. In practice, a scan lens of 100 mm f.l. can be convenient as laser beam diameters of 10 mm can be readily handled by small galvanometer scanners, as shown in Figure 2. In particular, when constructing time-resolved instruments, where potential reflections from optical components, mounting mechanics etc. need to be traced and eliminated, a longer, but still acceptable 4f system is often desirable. Finally, when multibeam scanning arrangements are envisaged, wider laser beamlets are often desirable. Scan mirror Scan lens Tube Objective Excitation laser beam/fluorescence emission beam Image plane Figure 2. A longer microscope laser beam scanning optical arrangement The scanner relay system Figures 1 and 2 however do not take care of a fundamentally important issue: only a one-directional scan is catered for. In order to generate a two-dimensional scan, an additional scanner and mirror are required. Many designers use a close-coupled galvanometer/mirror system. In such systems, Optical laser beam scanner lens relay system.doc 1

neither the X or the Y scanners are optimally placed and the beam moves in the objective back focal plane. We have never found such arrangements to be optimal when attempting to construct high quality microscopes, particularly when two-photon excitation is used. A superior method exploits the fact that one of the scanner mirrors can be optically relayed onto the surface of the other mirror. Such an optical relay system can be most optimally constructed using long focal length reflectors: any astigmatism introduced by one reflector can be compensated for by the other and achromatic operation can be readily obtained. However, a long (or appropriately folded) optical system then results and this cannot be readily prototyped. Such arrangements are best left to commercial implementations of laser scanning instruments. We describe here a simpler system which can be constructed from Thorlabs (http://www.thorlabs.com/) cage system components in a linear fashion, as shown in Figure 3. Figure 3. A galvanometer scanner lens relay system constructed form Thorlabs C6W cubes on the ends, CP02 / CP02T cage plates and SM1L05 lens tubes. A custom machined CP01 plate in the centre forms a slit and isolates the X and Y scanning systems. Plastic tubes (Thorlabs SC1L24) are held in the slit assembly and in dummy lens tubes (not shown in the SolidWorks model) A lens-coupled system is inevitably chromatic to some extent and it is hard to ensure field flatness with standard, i.e. commonly available lenses. Nevertheless, a very good performance can be obtained with a little bit of care in the design. Even a very simple design using achromats is adequate, although significantly improved performance can be obtained if meniscus lenses are added. The general rule in optics is of course to use long focal length lenses and only use the central portion of the lens. An obvious way o achieve this is to reduce the scan angle as mush as possible and thus to utilize a relatively large laser beam diameter, as described above. We present here the design that we use in our laser scanning microscopes. These have been primarily designed for time-resolved imaging applications where the relatively large, but not unduly large lens-lens distances allow reflections to be suitably removed through the use of baffles and beam stops where appropriate. We use this system in parallel with a widefield camera imaging system and thus adjust the image plane to have comparable dimensions to that of the camera used. This is a 2/3 chip size device and the image plane thus has a diagonal distance of 11 mm, though in practice a square, rather than rectangular image is used The design has been modeled with Optics Lab (http://www.optics-lab.com/) ray-tracing software. This software package is extremely straightforward and intuitive and we find this convenient for prototype modeling. We first present, in Figure 4, the layout of the system and its on axis performance for three wavelengths 486 nm, 546 nm and 633 nm, with the design optimized in the green (546 nm). After the first scan lens, all rays fit within the 16 µm diffraction-limited Airy disc, while after the scan lens (2 x 175 mm focal length achromats), the performance is somewhat worse, Optical laser beam scanner lens relay system.doc 2

but still close to the diffraction limit ( 30 µm spot, rather than 25 µm spot). At any one wavelength, however, diffraction-limited performance can be obtained. These data are obtained with a laser beam diameter of 6 mm. Figure 4. On-axis performance of scanner relay lens system and scan lens We now increase the scan angle to 2.5 degrees, equivalent to the limit of the image dimension, and show this in Figure 5. The spot diameter, across the wavelength range is only slightly worse, and Figure 5. Performance of the scanner relay lens and scan lens system with a 2.5 degree scan angle, equivalent to a 9 mm diagonal image plane. Optical laser beam scanner lens relay system.doc 3

the modulation transfer function remains respectable at around 50 line pairs per mm for 50% contrast, close to the theoretical maximum. Although this looks perhaps worse than what could be tolerated, the data in Figure 5 refer to all wavelengths, so in Figure 6, we present data at individual wavelengths, indicating that the performance is actually pretty good! Figure 6. Performance of the scanner relay lens and scan lens system with a 2.5 degree scan angle, at red and green wavelengths, showing that diffraction-limited performance can be obtained with only a slight shift in the image plane (equivalent to a small change in focus position Optical laser beam scanner lens relay system.doc 4

The change in focus as function of wavelength is shown in Figure 7, for on axis (zero deflection) and a 2.5 degrees deflection, but this time a wider range of wavelengths is used (405 nm -656 nm). Figure 7. Focus shift as a function of wavelength for the scanner relay lens and scan lens arrangement, indicating that a very small (< 1 mm) of focus shift in the image plane is present. This is not ideal, but quite acceptable when working over a small range of wavelengths. Finally, in Figure 8, we present the field curvature of the system. Some pincushion distortion is present, but this is of respectably low magnitude. Although not presented here, the performance of the optical system is similarly respectable in the other direction, i.e. as far as fluorescence emission light is concerned. Optical laser beam scanner lens relay system.doc 5

Figure 8. Field distortion performance of the system, showing that a very slight pincushion distortion is present 3. Performance Of course, optical modeling is useful, but no amount of modeling can ever be a substitute for the actual performance of such a system. This of course depends on numerous other factors, such as microscope tube lens performance, objective performance, laser beam quality, dichromatic filter quality, etc. While we do not describe the other portions of the optical system here, we can show an example of an image acquired with this system, shown in Figure 9. This shows Human epithelial carcinoma cells (A431) stably expressing cdc42-gfp, imaged with a 20x, 0.75 na Nikon objective. Figure 9. Example images obtained with the laser scanning system described here, showing GFP fluorescence from a human epithelial carcinoma cell line (right) and Cy2 emission from a breast cancer cell line. 0 Photon count 500 This note was prepared by B. Vojnovic and IDC Tullis is June 2011. We acknowledge the financial support of Cancer Research UK, the MRC and EPSRC. Gray Institute, Department of Oncology, University of Oxford, 2011. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-ncnd/3.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA. Optical laser beam scanner lens relay system.doc 6