vantage S2 enclosure system



Similar documents
vantage S2 enclosure system

Data Center Racks. Vantage S2. Enclosure System. Switch N to Eaton.

Vantage Enclosure Systems

Rack Systems Solutions

Introducing an innovative team devoted to providing unparalleled customer service and support for ISPs, ASPs and Hosting applications.

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Secure your IT equipment with confidence... secure with NetClosure

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

ADC-APC Integrated Cisco Data Center Solutions

techorganizer and techbench built for durability, designed for flexibility

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinet V800 V800 CABINETS

Customized Server Cabinets

Compaq Rack Options and Accessories. Monitors and Keyboards

Power and Cooling for Ultra-High Density Racks and Blade Servers

Dimensions (HxDxW) Total Cabinet Area 89.96x x 24 in/ 2,285 x 1, x mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

How To Power A Bladecenter H Servers

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Choosing Close-Coupled IT Cooling Solutions

DATA CENTER SOLUTIONS

DCF Optimized Rack System Selection Guide

Access Server Rack Cabinet Compatibility Guide

Rack Hygiene. Data Center White Paper. Executive Summary

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

data center accessories

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

APC APPLICATION NOTE #112

Benefits of. Air Flow Management. Data Center

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

Rittal Liquid Cooling Series

How To Build A T7 Rack For Information Technology

How To Fit A Dll 2420 And 4220 Rack Enclosure

Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Distributing Power to Blade Servers

Layer Zero. for the data center

RACK ENCLOSURES & ACCESSORIES

RACK ENCLOSURES AND OPEN FRAME RACKS FOR SERVER AND NETWORKING APPLICATIONS IN IT ENVIRONMENTS

Powerware Enclosure Solutions Product Focus

SERVER ROOM CABINET INSTALLATION CONCEPTS

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

How To Run A Data Center Efficiently

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Data Center Trend: Distributed Power in the White Space

Managing Data Centre Heat Issues

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

How to Meet 24 by Forever Cooling Demands of your Data Center

Rack Power Distribution. Worldwide

Product Brochure. Airflow Management Solutions

Airflow Management Solutions

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Eaton 93PM UPS Where aesthetics meet intelligence.

APC APPLICATION NOTE #92

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry

Key Considerations for Selecting Server Cabinets for Seismic Areas

W H I T E P A P E R. Computational Fluid Dynamics Modeling for Operational Data Centers

Thermal Optimisation in the Data Centre

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Cabinet & Enclosure Systems

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant

Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

Rack installation instructions

Power and Cooling Guidelines for Deploying IT in Colocation Data Centers

Cisco Nexus 7000 Series.

InstaPATCH ZERO Solution Guide

Environmental Data Center Management and Monitoring

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

The New Data Center Cooling Paradigm The Tiered Approach

Managing Cooling Capacity & Redundancy In Data Centers Today

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Rack Basics: Everything You Need to Know Before You Equip Your Data Center

Small Data / Telecommunications Room on Slab Floor

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Server Technology, Inc.

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Cabcon. Data Centre Solutions. an acal group company UK +44 (0) IRE (00353)

Energy-efficient & scalable data center infrastructure design

Bringing value to colocation data centers

Component Series Racks Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4

Transcription:

vantage S2 enclosure system

The Lean Data Center The days when the data center was a static environment performing batch processing have turned into a 24/7 virtual operation focused on real time processing anywhere, anytime. On a daily basis, new equipment is deployed in the data center, resulting in rapidly increasing power consumption and escalating heat output. Data center managers are constantly moving, adding and changing IT equipment and electrical circuits all while trying to reduce or maintain costs. This rate of change, combined with the pressure to control costs, forces data center managers to do more with less. So how do you achieve a lean operation? Choose a business partner that can truly consolidate your enclosure, thermal and power management, security and service needs under one umbrella. Work with Wright Line, a data center infrastructure partner you can trust. The benefits are three-fold: Vendor consolidation reduces procurement costs. Complete, pre-configured solutions increase speed of deployment. Working direct with the manufacturer increases quality control. Our single-order flow, Just-In-Time manufacturing process and focused efforts result in an unprecedented low defect and corrective action rate. At Wright Line we ve served a very loyal customer base for the past 70 years. And, the benefits we reap in our operation, we pass on to our clients. 2 800-225-7348 www.wrightline.com info@wrightline.com

vantage S2 enclosure system STORE Enclosure platform is cost effective and versatile to keep pace with the rapidly evolving server market Exact 24" (610mm) enclosure width is designed to complement the North American standard 2' x 2' (610mm x 610mm) tile preventing end-of-row creep Guaranteed compatibility with TIA/EIA-310-D* standard size equipment Fully welded frame rated for 2,000 lbs. (909kg) static and dynamic load capacity handles even the heaviest server equipment Customizable to address our individual customer needs Rolls through a 7' (2.13m) doorway to ease deployment Offers top access for adjustment of leveling feet, increasing speed of deployment COOL Provides superior airflow with its fully perforated front and rear door system Exceeds most server manufacturers requirements for open perforation airflow with 940 sq. in. (6065cm 2 ) of open perforation Intelligent thermal management options extend life of the IT equipment and infrastructure A multitude of fan options available for increased thermal management POWER Basic, metered and managed power solutions to fit individual monitoring and management requirement at the enclosure level Wide variety of custom and standard options for power densities that are increasing and unpredictable Uninterruptible Power Supply (UPS) solutions address the growing need for power availability MANAGE Easily accommodates up to 800 CAT5e/6 cables without bends or breaks Broad offering of cable management accessories for proper cable distribution and management Overhead cable management system offers flexibility and ease of deployment Comprehensive environmental monitoring devices provide advanced detection of emerging problems Devices provide predictive failure analysis allowing you to act, rather than react SECURE Our 125 different lock core options provide customized access to individual areas or applications in the data center An array of electronic locks are offered for remotely managed access A wide variety of security devices minimize damage and unauthorized access Security devices provide protection rather than detection *TIA (Telecommunications Industry Association) EIA (Electronic Industries Alliance) 800-225-7348 www.wrightline.com info@wrightline.com 3

Frequent technology refreshes one enclosure platform The data center has undergone major changes over the past decade. Data centers built 10-15 years ago have infrastructure that is far outdated in terms of the technology it must support. The rapid rate of technological innovation combined with the immense amounts of data being created and the growing need for instantaneous access to that data have created a highly evolving IT environment. The Vantage S2 enclosure platform has been designed with change in mind, which is why so many Fortune 500 companies have standardized on it. Wright Line s forwardthinking design engineers continue to develop scalable enclosure solutions to help customers store their latest technology without having to change enclosure platforms, allowing them to maximize their original investment. Wright Line is so confident that the Vantage S2 enclosure will suit your needs that we offer a Compatibility Guaranteed policy. It guarantees that we can offer a solution to store your server and network equipment in the Vantage S2 or we will give you a full refund.* Vantage S2 Depths (over doors) 39" (991mm) 42" (1069mm) Widths (w/o sides) 24" (610mm) 30" (762mm) 12U 25U 42U 45U We guarantee that all 19" TIA/EIA-310-D compliant equipment will physically fit into the Vantage S2 enclosure.* *This guarantee includes all equipment that complies with the TIA/EIA-310-D standard with the mounting hardware provided by the original equipment manufacturer (OEM). OEM server rails may be required. Wright Line LLC will not be responsible for equipment that physically fits into the enclosure, but does not comply with TIA/EIA-310-D. 4 800-225-7348 www.wrightline.com info@wrightline.com

STORE 24" (610mm) Wide Enclosure Standard server enclosure optimizes the footprint in the data center with its exact 24" (610mm) width that eliminates end-of-row creep. 30" (762mm) Wide Enclosure The wider Vantage S2 comfortably accommodates network equipment as well as hybrid environments where large amounts of cables are required. 39" (991mm) Deep Enclosure* Cost effective solution for shallow servers and tower (non-rack-mount) technology. 42" (1069mm) Deep Enclosure* Accommodates deeper server technologies while providing ample cable and power management provisions in the rear integrated channel. * Depth includes front and rear door All products and company names are trademarks or registered trademarks of their respective holders. 800-225-7348 www.wrightline.com info@wrightline.com 5

Frequent technology refreshes one enclosure platform Standardization Many of our customers have chosen to standardize on the Vantage S2 because of Wright Line s superior rack technology, first-class customer service and one of the Perforated Top industry s largest direct sales forces which ensures that we have representation located near you to respond to your Solid Top changing requirements. Extension Side Panel Lacing Bar Standardization not only eases procurement and vendor management, but it helps drive out waste due to fluctuating costs, inconsistent quality and varying customer support and responses from vendors. Vantage S2 lends itself to standardization with an open platform that can accommodate everything from SUN s proprietary dimensions and mounting methods to HP s high-density blade Side Panel technology that requires a high weight load capacity. Stabilizer Plate Casters Perforated Front Door 6 800-225-7348 www.wrightline.com info@wrightline.com

STORE Perforated Rear Door Split Fan Door Up to 880 cfm (1495m 3 /h) Vantage S2 Features: Top panel provisions for Overhead Cable Management System for flexibility and ease of deployment Reversible and tool-less doors to ease in-field changes Reversible top panel for flexible cable management access Half-height divider panels for ease of deployment Baying hardware included 0.375" (9.52mm) square holes, #10-32 and #12-24 threaded hole vertical rail options 510 sq. in. (3,290cm 2 ) of open space in the base 6" (152mm) Extension Frame Split Perforated Door Split rear doors that require less clearance in the service aisle Top access leveling guides to increase speed of deployment Roll-Out Shelves Our 1U (100 lbs./45kg) or 2U (200 lbs./91kg) roll-out shelves support non-rack-mount equipment that requires easy, all-around access. Fixed Shelves Our less than 1U (200 lbs./91kg) and 1U (400 lbs./182kg) fixed shelves support even the heaviest non-rack-mount equipment. Utility Drawer/Worksurface Our 3U or 4U storage drawer keeps peripheral equipment like CDs, DVDs, mice and manuals handy and doubles as a worksurface that can support a laptop. Please refer to our Data Center Accessories brochure for more detailed storage accessories information. 800-225-7348 www.wrightline.com info@wrightline.com 7

Addressing your current and future requirements As server sizes have decreased, heat densities in enclosures have increased dramatically. Vantage S2 has been designed with this in mind, creating optimal thermal dynamics by moving heat out of the enclosure in the manner intended by server manufacturers front to rear. An industry leading 940 sq. in. (6065cm 2 ) of Vantage S2 Cooling Scalability Load (kw) Rear Door Side & Top Panels Up to 3.5kW Perforated Solid Up to 4.5kW 440 cfm (748m 3 /h) fan tray (x2) Solid Up to 8.5kW 880 cfm (1495m 3 /h) fan tray (x4) Solid Up to 13kW Solid 1350 cfm (2294m 3 /h) fan tray perforation in the front exceeds most server manufacturer requirements for enclosures. Additionally, fan trays mounted on the rear doors exhaust heat for high density applications. When the average density per enclosure exceeds 3,500 Watts, it is recommended that an Environmental Monitoring Unit (EMU) be used. An EMU actively monitors temperature, humidity, voltage, airflow, power and other critical elements at several points in the enclosure via the network. Information can be accessed and viewed anywhere over the web through a user-friendly interface. Offering predictive failure analysis increases the availability of the critical systems.the EMU alarms users when and if certain environmental thresholds are exceeded allowing you to respond before a failure or shutdown occurs. Koldlok Offers a permanent airflow sealing solution in the raised floor, accepting perpetual cabling changes. Tool-less Blanking Panels Significantly reduce recirculation of hot exhaust air to the equipment inlet. Door Fans Split rear fan doors maintain hot-row, coldrow approach. Each UL approved fan tray offers 220 cfm (374m 3 /h) for a total of 880 cfm (1495m 3 /h) cooling capacity. Please refer to our Data Center Accessories brochure for more detailed cooling accessories information. 8 800-225-7348 www.wrightline.com info@wrightline.com

COOL Heat Containment/Removal System Offers up to 13kW of heat removal in an optimal environment that features a drop ceiling and a consistent 68º-77ºF (20º-25ºC) air supply along the front face of the enclosure.the result is achieved by effectively containing the hot air in the rear of the enclosure and removing it at high velocity through a duct into the drop ceiling. Thermal Diagram The thermal diagram illustrates the temperature gradients inside a Vantage S2 enclosure with fully perforated top, front and rear doors and solid side panels. Cooling Methodologies Vantage S2 has been designed to fit seamlessly into all four major cooling layouts (as illustrated below).* *As outlined in "Thermal Guidelines for Data Processing Environments" by ASHRAE (American Society of Heating, Refrigeration and Air-conditioning Engineers, Inc.) 800-225-7348 www.wrightline.com info@wrightline.com 9

Powering increasingly unpredictable equipment densities Vantage S2 provides superior power and power management capabilities through a basic, metered and managed rack power product offering. What was once a simple task has evolved into a calculated strategy to manage power-intensive servers in densely-packed enclosures. By working closely with the IT community, server manufacturers and power suppliers, our product engineers continually develop new products and enhancements for a wide range of enclosure applications. Vantage S2 is designed to support the most demanding mission-critical power applications, while remaining scalable to accommodate future requirements. An ever expanding power offering includes the most basic 120V, 15 Amp strip up to a remotely monitored 208V (three-phase), 60 Amp solution specifically for blade technology. Three-Phase Power Distribution An increasing need for more power within the enclosure has prompted a push to three-phase power strips that can deliver up to 17.2kW of power. Decreasing the number of cables lowers installation costs and reduces cable clutter. More importantly, it allows for unimpeded airflow to the server exhaust. Three-Phase Provides up to 17.2kW in just one power strip (60 Amp shown). Single-Phase Provides up to 9.9kW in one power strip. Please refer to our Data Center Accessories brochure for more detailed power accessories information. 10 800-225-7348 www.wrightline.com info@wrightline.com

POWER Basic Power Strip Simple and reliable rack-optimized power distribution. Vertical Mounting Maximize server storage while using space more productively. Metered Power Strip Monitoring the power draw at the rack level helps prevent unexpected branch circuit overloads. Managed Power Strip Remotely manage and monitor power for mission critical equipment. Zero U Mounting Hole pattern allows multi-vendor mounting of power strips. Uninterruptible Power Supply High quality power solutions that increase power availability and system uptime to enterprise-wide networks in tower or rack-optimized form factors. MGE E RT Dual-feed, high availability UPS designed for the most sensitive high-density server environments.this high performance UPS is engineered for demanding customer applications. MGE Pulsar E RT True on-line double-conversion technology required for missioncritical network applications and server environments. Continuous voltage and frequency regulation. 800-225-7348 www.wrightline.com info@wrightline.com 11

Cable Management made simple The Vantage S2 s unique platform addresses cable and access management concurrently. From a structural standpoint, Vantage S2 s frame design efficiently accommodates large quantities of cables and provides unmatched enclosure-toenclosure, raised floor and overhead cable access. This approach is not only crucial to safeguarding cabling, but it is required to maximize airflow and provide clear, easy access to equipment. Cable Strain Relief Avoid unnecessary cable bends and breaks with strain relief bars that gradually transition cables from a horizontal to a vertical position. 1U/2U Cable Ring Organizer Effective horizontal cable management. Also available as a kit of four individual rings. Please refer to our Data Center Accessories brochure for more detailed cable management accessories information. Middle-Rear Lacing Bar Allows the two integrated rear channels in the enclosure to be used for cable management while adding power strips to the middle lacing bar. 12 800-225-7348 www.wrightline.com info@wrightline.com

MANAGE Overhead Cable Management System Allows users to route cables on top of the enclosure and offers separate rows for power and data. Top Panel This perforated top panel features four cable management holes that can be positioned on either end of the enclosure based on cable entry points. High-Density Cable Organizer Organize and manage large amounts of cables front-to-rear in compliance with TIA/EIA-568-A bend radiuses. Transition Tray Enclosure to enclosure, horizontal cable management with TIA/EIA-568-A compliant bend radiuses. Take-up Spools Efficient and TIA/EIA-568-A compliant organization of excess cabling within the enclosure. Rear Channel The integrated rear channel provides an efficient space to properly manage cables using cable rings or Velcro straps. Velcro Buckle Straps Offering superior strength, our reusable Velcro buckle straps are available in 9" (229mm) and 12" (305mm) lengths to manage cable loads. 800-225-7348 www.wrightline.com info@wrightline.com 13

MANAGE Infrastructure Management A broad range of products provide streamlined solutions for management of the infrastructure. By combining keyboard, video and mouse (KVM) switching, LCD displays and environmental monitoring products, we offer flexible connectivity, efficient switching and convergence of technologies. Management Product Features: Integrated LCD Display and KVM solutions IP-Enabled KVM Multi-functional, multi-user solutions for KVM, serial and power management. Three-button touchpad or two-button trackball mouse options Local or remote web based user access, IP enabled User name and password protection Alarm notification prior to system failure via e-mail or SNMP Event and statistical data stored for trend mapping or root cause analysis KVM Switches Powerful CAT5 based KVM switches reduce cable clutter and speed of deployment. Advance Detection Monitoring system provides early detection of emerging environmental problems, minimizing equipment damage and downtime. SNMP enabled environmental monitoring system allows for quick deployment to the network. LCD Display Compact 1U monitor with keyboard and mouse, also available with 8 or 16-port KVM. Please refer to our Data Center Accessories brochure for more detailed infrastructure management and security accessories information. 14 800-225-7348 www.wrightline.com info@wrightline.com

SECURE Protecting your investment Security remains a growing concern in today s data center environments. After all, the life-blood of your business is running on the equipment that is stored and monitored within your enclosures. In addition to the storage, thermal and cooling issues Vantage S2 solves, it also offers a wide selection of safeguard and security devices that protect the mission-critical equipment behind your enclosure doors. With security appliances and accessories ranging from standard key locks to electronic access control and graphical management tools, you can rest assured that we re completely focused on the deployment and reliability of your systems. Cage Provide the ultimate level of security for your valuable information systems.the cage system is the perfect solution for data center environments requiring subdivision or a higher level of security. Standard Locks Swing Handle Combination Lock Friction Lock High quality standard locks feature 125 key options with master override. Cost effective locking handle that will hold in position with and without the use of keys. Mechanical handle with combination lock and override key. Cost effective multi-layer security. Kaba Mas self-powered friction lock offers advanced yet traditional access keypad. 800-225-7348 www.wrightline.com info@wrightline.com 15

Wright Line, a global leader in the design and manufacture of consoles, Also see our full line of furniture that supports your Data Center environments. enclosures, office and other specialty furniture, has been serving the data center, office, call center, electronic laboratory and high-tech manufacturing environments for more than 70 years. Our innovative designs are manufactured to the highest quality and safety standards. Data Center Accessories Brochure Profile Consoles Brochure Wright Line LLC World Headquarters 160 Gold Star Boulevard Worcester, MA 01606 Tel: 800-225-7348 508-852-4300 Fax: 508-365-6178 www.wrightline.com info@wrightline.com Wright Line - Europe Regus House 400 Thames Valley Park Drive Reading Berkshire, RG6 1PT England Tel: 44-1189-637-935 Fax: 44-1189-637-934 Wright Line - Japan Win Nishi-Waseda Building, SF 2-20-9, Nishi-Waseda, Shinjuku-Ku, Tokyo 169-0051 Tel: 81-3-5273-6100 Fax: 81-3-5273-6055 TAB Canada 130 Sparks Avenue Willowdale, Ontario M2H 2S4 Tel: 800-667-4020 Fax: 800-765-9705 For additional international representation, please contact us at: 800-225-7348 or email to: info@wrightline.com Please ask for details of other products from Wright Line. All products and company names are trademarks or registered trademarks of their respective holders. Every effort has been made to ensure that the information contained herein is correct. The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication. Wright Line LLC, 2005 05-01/LP-10K/08-05 Printed in the USA.