232982 KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger



Similar documents
VOICE RECORDING SYSTEM ISDN PRI / BRI

LwLVision-USB 2.0. Installation Guide

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

How To Use A Power Supply Unit (Upu)

I STAR COMPUTER CO., LTD

Controlers. Controler

Inductive Proximity Sensors

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DS 600. A contact free flux gate based current measurement sensor 600A rms

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

=============================== WARNING

PERF10 Rubidium Atomic Clock

Video surveillance camera Installation Guide

650W Single Output Power Supply

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Features. High Brightness LED Light source

UMEC International Corporation

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Online UPS. PowerWalker VFI 1000R/1U

Research RF Sputtering Packages

User and installation manual

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

IMPORTANT SAFETY INSTRUCTIONS

BITMAIN. APW PSU Series User Guide

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

User s Manual AURORA 1.2K/2.2K

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Series 7500 Torque Sensor

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Unidirectional Transmitter/ Receiver Units Introduction

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

1. User Safety Instructions

STERILIZERS, LABORATORY DRYING OVENS

Rack mounted telephone- and leased line modem for industrial applications

Series AMLDL-Z Up to 1000mA LED Driver

Telephone- and leased line modem for industrial applications TD-36

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

AK-STM32-LKIT Development Board

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Manual. Solar Fountain Mobile Phone Charger

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

MINI MCR-SL-R-UI(-SP)

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LOXONE 12 Channel Amplifier

Electronic Control Devices The European Product Catalogue 2007

User manual Rev. 1.2 (17/04/2015)

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

MultiViu Flex 7 Data Sheet

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

DC Electronic Loads 8500 series

Description. Dimensions. Features. precision works better

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Failure code manual. content

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

SMART SENSOR COLLECTION

Brushless DC Motor Controller Product Specification Assembly 025F0129

WD-AMX Water Detection Controllers

Contents. Document information

DVT913 TV CHANNEL CONVERTER

NEW. EVEN MORE data acquisition and test stand automation

LDG DTS-4/4R Desktop Coaxial Switch / Remote

DALI RC BASIC SO. Control unit Operating instructions

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

RY2 miniature industrial relays

Installation and User Guide

PWM-60 series IP67 TRC ELECTRONICS, INC

LED...A Q Series Sealed High-Intensity

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Electronic Control Devices The European Product Catalogue 2007

Infrarot-Bewegungsmelder IP44

SMS GSM Alarm Messenger

Guideline Laser Series

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Light Source User Guide

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Transcription:

RANGE OF PRODUCTS 233393 KLQ750LQ-N LED lightsource Ø4.25/3000K 233394 KLQ750LQ-N LED lightsource Ø4.25/7000K 233154 KLQ750LQ-N LED lightsource Ø4.25/8500K 233258 KLQ750LQ-F LED lightsource Ø4.25/8500K/feedback 232982 KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger KEY FEATURES @8500K High brightness with over 170klux* Overheating protection Lifetime > 15000 hrs Dimmable on device or via USB / serial Power supply 24VDC Strobe rate up to 35kHz (50% duty-cycle) @ 100% Brightness via 24V trigger input or LVDS Separation between LED unit and control unit * Measurement: 1m glass fibre-optic, Ø4.25mm active, 50mm distance, 170klux - 1 -

PLEASE Read this manual completely before using these products. CAUTION In order to avoid the risk of fire or electric shock do not expose this apparatus to rain, humidity or heat! WARNINGS Looking directly at operating LED can cause permanent eye damage! Do not operate LED without a light guide connected to LED unit! Do not remove light guide without turning off light source! PRECAUTIONS 1. Isolate cold light source from supply distribution before repair and maintain work. 2. To avoid electric shocks never remove screws or coverings. 3. Maintenance work should only be carried out by qualified service technicians. 4. Handle the cold light source with care. The cold light source always has to be handled carefully. 5. Avoid rain or humidity, do not use the cold light source at wet places. When the cold light source gets wet, immediate actions are necessary. Switch off the power supply and have it maintained by a service technician. Humidity can damage the cold light source and can lead to electric shocks. 6. Do not use the cold light source beyond the prescribed areas of temperature, air humidity and power supply. 7. Only use it indoor 8. Ambient temperature must be in the area between 0 C and +30 C 9. Do not use the cold light source when air humidity is over 90% 10. For input power supply see technical characteristics on last page PREFACE We developed the cold light source in order to attach glass optical fibre applications. - 2 -

INDEX OF CONTENTS KEY FEATURES... 1 PLEASE... 2 PREFACE... 2 PURCHASED PARTS PACKAGE... 4 ADAPTATION OPTIONS... 5 CONNECTORS LED UNIT, FRONTSIDE... 6 WARNINGS... 6 CONNECTORS LED UNIT, BACKSIDE... 6 CONNECTORS CONTROLLER, FRONTSIDE... 7 CONNECTORS CONTROLLER, BACKSIDE... 8 USB AND RS232 COMMANDS... 9 LVDS RJ45... 10 LVDS SPECIFICATION... 10 24V TRIGGER INPUT (4PIN CONNECTOR)... 11 24V TRIGGER SPECIFICATION... 11 FREQUENCY VS. BRIGHTNESS (DUTY CYCLE 50%)... 12 LED SPECTRUM... 13 LED TYPE... 13 TECHNICAL CHARACTERISTICS... 14 DISCHARGE CURVE... 15 PLEASE CONTACT US FOR MORE INFORMATION:... 16-3 -

PURCHASED PARTS PACKAGE 232982 KLQ750CO controller 233154 KLQ750LQ-F LED lightsource Instructions manual 233348 KLQ750 cable 24V main-power 233349 KLQ750 cable sensor supply 233350 KLQ750 cable LED power 233351 KLQ750 cable 24V BNC trigger input - 4 -

ADAPTATION OPTIONS Light source is used with fibre-optic. There are several adaptation options available for example: line lights ring lights spots. - 5 -

CONNECTORS LED UNIT, FRONTSIDE Light output fibre-optic WARNINGS Looking directly at operating LED can cause permanent eye damage! Do not operate LED without a fibre- optic connected to LED unit! Do not remove fibre-optic without turning off light source! CONNECTORS LED UNIT, BACKSIDE Supply for LED, 4-PINS Sensor signals from LED unit, 6-PINS - 6 -

CONNECTORS CONTROLLER, FRONTSIDE Controller display Brightness control knob The controller display shows: target intensity in percent actually measured temperature at the LED board - 7 -

CONNECTORS CONTROLLER, BACKSIDE RS232 connector RJ45 connector for LVDS 24V trigger input Trigger input switch (Trigger / steady) Power supply for LED, 4-PINS Sensor signals from LED unit, 6-PINS Power supply 24VDC, 2-PINS Do not use (engineering purposes) USB connector - 8 -

USB AND RS232 COMMANDS Command SET_BGH GET_BGH GET_TMP SET_DSP OK SET_POT ERR LED_HOT Description Set the brightness of the light source. Before using this function first set potentiometer off. Example: SET_BGH 0 = 0% SET_BGH 100 = 100% Read the actual brightness from the light source Example: GET_BGH Answer: SOLL 95 (=95%) Read the actual temperature from the LED Example: GET_TMP Answer: TEMP 65 (=65 C) Set Display on or off Example: SET_DSP 0(zero) = off SET_DSP 1 = on Transmitted when command was successfully detected Turn on or off the potentiometer. Is needed on USB/RS232 function. Otherwise the controller uses the value of the potentiometer. Example: SET_POT 0(zero) = off SET_POT 1 = on Transmitted when command was not successfully detected Transmitted when LED is on over temperature - 9 -

LVDS RJ45 Pin Definition 1,2 Output - HIGH on LED overheats 3,6 Input HIGH LED on LVDS SPECIFICATION Parameter Min Typical Max Unit Differential Output 250 355 450 mv Output High Voltage 1.4 1.6 V Output Low Voltage 0.90 1.1 V Offset Voltage 1.125 1.2 1.375 V LVDS Input High +100 mv Threshold LVDS Input Low Threshold -100 mv Input Current -10 ±1 +10 µa - 10 -

24V TRIGGER INPUT (4PIN CONNECTOR) Pin Definition 1 VCC 2 Output LED Error 3 Input LED Trigger ON/OFF 4 VSS 24V TRIGGER SPECIFICATION Parameter Min Typical Max Unit Input Voltage 22 24 26 V Output Voltage 22 24 26 V Input Current 100 ma Output Current 25 ma ON Delay (triggered) 5 µs OFF Delay (triggered) 5 µs LED ON (triggered) 4 µs - 11 -

FREQUENCY VS. BRIGHTNESS (DUTY CYCLE 50%) 115% Brightness % 110% 105% 100% 95% 90% 85% 80% 500Hz 1k 5k 10k 20k 35k 100k - 12 -

LED SPECTRUM LED TYPE Type Color Rendering Index Typical Values Color Temperatur Part.no. WTH, Tungsten White CRI 92 3035K 233148 WDH, Daylight White CRI 92 7000K 233395 WCS, Cool White CRI 75 8500K 233147-13 -

TECHNICAL CHARACTERISTICS Parameter Min Typical Max Unit Supply voltage 22 24 26 VDC Power consumption 120 W Operating temperature Storage temperature Controller dimensions (H x W x D) Controller weight Controller cooling LED unit dimensions (H x W x D) LED unit weight LED unit cooling 0 C to +30 C -30 C to +70 C 28,5 dba, active fan 0.8 Sone, active fan - 14 -

DISCHARGE CURVE - 15 -

- 16 -

- 17 -

- 18 -