Similar documents
3DLevelScanner II TECHNICAL DATA SHEET

Technical Data Sheet. 3DLevelScanner

Plastic tube flowmeters Series PT/PS

How To Use A Flowmeter

VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES

Turbine Flow Sensor Series VTR

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

O C M III. Open Channel Flow Monitor

BR LD GHz Pulse Radar Level Transmitter. Overview. BR LD20 is a 2-wire, 5.8GHz pulse radar level transmitter for

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

crm+25/d/tc/e Extract from our online catalogue: Current to:

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Digital inductive conductivity transmitter

Various Technics of Liquids and Solids Level Measurements. (Part 3)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Typical Aluminum GFM Mass Flow Meter

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Centro-Matic Automatic Lubrication Systems System Controls

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Flow switches Series AD/VH

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

SITRANS F flowmeters SITRANS F M

Electronic Control Devices The European Product Catalogue 2007

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Inductive Proximity Sensors

Differential-Hall-Effect based Sensors Series A5S

Givare NC-SRS 280 och 880

Duct Humidity Transmitter

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

API Marine. BMS Presentation. Ballast Measurement Systems

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Inductive sensor NI10-M18-Y1X-H1141

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Chapter2. Installation

Conductive Level Switch FK 2 Technical Data:

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Safety at a high level!

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

How To Use A Ds340 (Dsp)

THERMAL ENERGY METER MC 108/ET

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

and Accelerometers

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Micro Motion 3098 Gas Specific Gravity Meter

4 Posiflow Proportional Solenoid Valves

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

S300 Series Dust Monitors

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ATL Fuel Level Sender Probes

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

SEISMIC VELOCITY TRANSDUCER T1-40

HYDRUS ULTRASONIC METER

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electric Rotary Actuator - On/Off or programmable control actuator

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electronic Flow Switches

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

IFC 070 Technical Datasheet

Series DFMT Digital Paddlewheel Flowmeter

CAPACITIVE LEVEL METERS CLM 36

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Series description: Wilo-Yonos MAXO

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Relative and absolute pressure switch type 529

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Mass Flow Meters & Controllers

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Electronic Control Devices The European Product Catalogue 2007

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Sense it! Connect it! Bus it! Solve it! EncoderS

Assisted lift operated 2/2-way solenoid valves Type EV250B

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Transcription:

CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted by the radar s antenna, travel at speed of light and a part of their energy, reflected by the surface of the medium to be measured, is received by the same antenna. The period of time (fliying time) between the emission and the arrival of the impulses, is proportional to the existing distance between the antenna and the surface of the medium to be measured. The electromagnetic wave travels at a very high speed (nanosecond), so it is difficult to identify it: BM COMPACT WAVE 26 GHz Radar Level Meters, thanks to their integrated management system, use a suitable demodulation technology that allows them to identify the period of time between the emission of the impulses and their corrected reception and, consequently, determine and measure the level. The Alphanumeric Display allows the user not just to enter the data for the level measurement, but even to display and isolate false echoes. BM_WARE is a software for the configuration and calibration of the units with a PC is available too, it has HART communication protocol and it is used with a standard HART MODEM (mandatory). An advanced microprocessor and the EchoDiscovery technology make the device suitable for measurements in critical areas with hard conditions, such as high temperatures and high pressure. The function False Echo Storage identifies the correct echo, even if there is a false echo: in this way a correct measurement is gained. An integrated temperature sensor compensates the temperature in real time. The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or envinronment. PRODUCTS OVERWIEV COMPACT WAVE CW51 COMPACT WAVE CW52 COMPACT WAVE CW53

PRODUCTS OVERVIEW Display: Housings: HOUSING CODE A B / C D MATERIAL Plastic Aluminium Alloy (available also in Two-Chamber version) SS 316L Process Connections: TYPE E E1 F G H I J K MATERIAL SS 316L PTFE PP SS 316L PRESSURE -1 40 bar -1 3 bar Normal Pressure -1 40 bar -1 5 bar -1 40 bar -1 40 bar TEMPERATURE in C -60..+130-60..+250-40..+130-40..+80-60..+150-60..+130-60..+250-60..+400

PRODUCTS OVERVIEW Flanges: v TYPE L M N P MATERIAL PTFE / PP SS 316L PP GIMBAL SS 316L GIMBAL FEATURES Rust-Proof High Temp / Pressure Standard Temp / Pressure High Temp / Standard Pressure Antennas: TYPE R S T U V W MATERIAL PTFE PP (PTFE shield) SS 316L PTFE SS 316L (PTFE shield) SS 316L DIMENSIONS in mm Ø44, Length 137 Ø 44, Length 237 Ø98, Length 280 Ø98L, Length 440 Ø48, Length 140 Ø78, Length 227 Ø98, Length 288 Ø98L, Length 474 Ø123, Length 620 DN50 DN80 DN100 Ø98, Length 300 Ø98L, Length 480 Ø123, Length 625 Ø96 Ø246 Rust-Proof Standard Temp / Pressure High Temp / Pressure Rust-Proof / High Pressure Standard Temp / Pressure High Temp / Pressure

TECHNICAL DETAILS CW51 for liquids Applications: Level measurement insimple working conditions. Range: 0 30 m Accuracy: ± 10 mm Process connection: G1½ A - NPT Antenna: Rod Materials: antenna: PP / PTFE housing: plastic PBT-FR / Aluminium / Stainless Steel 316L Working temperature: -40 120 C Storage temperature: -40 80 C Relative umidity: <95% Working Pressure : -1 3 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Frequency: 6 GHz Beam Angle: 24 Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15 36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz 100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 ma, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Resistance 2 wires version: ref. to the following diagram Resistance 4 wires version max 500 ohm Integration time: 0 99s, programmable Cables entry: 1x PG 13.5 Weight: ~2 kg Diagram of loaded resistance, 2 wires version resistance Wiring resistance + HART resistance + loaded resistance HART Resistance Voltage limit for explosion proof version Tested value Voltage limit for not-explosion proof version Tested value Voltage

TECHNICAL DETAILS CW51 Precision Dimensions in mm with AL/316L frame Dimensions in mm H Length of Vessel Socket 50 100 150 Dimensions in mmwith PBT-FRL frame 200 250 300 Dimensions in mm ith AL frame (2 chambers)

ORDERING CODE CW51 P Standard Type of Antenna / Material A B Plastic Rod / PP / -40 120 C Plastic Rod / PTFE / -40 120 C Process Connection Length A 50mm B 100mm C 150mm D 200mm E 250mm F 300mm X Special type (on request)* Process Connections / Material GP Thread G 1½ A / PVDF NP Thread G 1½ NPT / PVDF FX Special type (on request)* Electronic B 4 20 ma HART 2 wires C 4 20 ma / 22,8 26,4 VDC / 4 wires** D 4 20 ma / 198 242 VAC / HART 4 wires** Housing Material / Protection B Plastic / IP67 A Aluminium / IP67 D Aluminium (2 chambers) / IP67** G Stainless Steel / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A YES

TECHNICAL DETAILS CW52 for liquids Applications: Level measurement in liquids. Suitable for highly erosive environments. Range: 0 30 m Accuracy: ±10 mm Process connection: PTFE Protected Flanges SS 316L PN16 DN 50, 100, 150, 200, 250, 300 Antenna: Rod Materials: antenna: PTFE housing: plastic PBT-FR / Aluminium / AISI flanges: SS 316L Working temperature: -40 150 C Storage temperature: -40 80 C Relative umidity: <95% Working Pressure : -1 16 bar Resistance to vibrations: mechanical vibrations10m/s2, 10 150Hz Frequency: 6 GHz Beam Angle: 24 Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15 36Vdc - Absorption: 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz 100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 ma, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Resistance 2 wires version: ref. to the following diagram Resistance 4 wires version max 500 ohm Integration time: 0 99s, programmable Cables entry: 1x PG 13.5 Weight: up to ~5 kg (depending on the Flange Ø) Diagram of loaded resistance, 2 wires version resistance Wiring resistance + HART resistance + loaded resistance HART Resistance Voltage limit for explosion proof version Tested value Voltage limit for not-explosion proof version Tested value Voltage

TECHNICAL DETAILS CW52 Precision Dimensions in mm with AL/316L frame Dimensions in mm H Length of Vessel Socket 50 100 150 Dimensions in mm with PBT-FRL frame 200 250 300 Dimensions in mm with AL frame (2 chambers) frame

ORDERING CODE CW52 P Standard Type of Antenna / Material / Working temperature B Plastic Rod / PTFE / -40 150 C Process Connection Length A 50mm B 100mm C 150mm D 200mm E 250mm F 300mm X Special type (on request)* Process Connection / Material FC PTFE Protected Flange DN50 PN16 SS 316L FD PTFE Protected Flange DN80 PN16 SS 316L FE PTFE Protected Flange DN100 PN16 SS 316L FK PTFE Protected Flange DN150 PN16 SS 316L YP Special connection (on request)* Electronic B 4 20 ma HART 2 wires C 4 20 ma / 22,8 26,4 VDC / HART 4 wires** D 4 20 ma / 198 242 VAC / HART 4 wires** Housing Material / Protection B A D G Plastic / IP66 Aluminium / IP67 Aluminium (2 chambers) / IP67 Stainless Steel 316L / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A YES

TECHNICAL DETAILS CW53 for liquids and solids Applications: Level measurement in liquids and solids (short-range). Suitable for hard working conditions. Range: 0 35 m Accuracy: ±10 mm Process connection: Flanges AISI 316L SS PN16 DN50,80,100,150,200 Antenna: Horn Ø 50, 80, 100, 150, 200 Materials: antenna: SS 316L housing: plastic PBT-FR / Aluminium / AISI flanges: SS 316L Working temperature: -40 200 C Storage temperature: -40 80 C Relative umidity: <95% Working pressure: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Frequency: 6 GHz Beam Angle: 29 ; 26 ; 24 ; 20 (depending on horn Ø) Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltage: 15 36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz 100KHz, Uss<10mV Supply 4 wires version: - Standard input version voltage: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 ma, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Resistance 2 wires version: ref. to the ollowing diagram Resistance 4 wires version: max 500 ohm Time of integration: 0 99s, programmable Cables entry: 1x PG 13.5 Weight up to ~6 kg (depending on the Flange Ø) Diagram of loaded resistance, 2 wires version resistance Wiring resistance + HART resistance + loaded resistance HART Resistance Voltage limit for explosion proof version Tested value Voltage limit for not-explosion proof version Tested value Voltage

TECHNICAL DETAILS CW53 Precision Dimensions in mm Heat Dissipator Dimensions in mm with AL/316L frame a K b C H H1 Dimensions in mm with PBT-FRL frame DN50 - Ø125 Ø165 Ø16 X4-123 DN80 Ø75 Ø160 Ø200 Ø16X8 60 123 DN100 Ø96 Ø180 Ø220 Ø16X8 120 123 DN150 Ø146 Ø240 Ø285 Ø20X8 205 123 Dimensions in mm with AL frame (2 chambers)

ORDERING CODE CW53 P Standard Types of Antenna / Material C Horn Antenna Ø 50mm / AISI 316L D Horn Antenna Ø 80mm / AISI 316L E Horn Antenna Ø 100mm / AISI 316L F Horn Antenna Ø 150mm / AISI 316L G Horn Antenna Ø 200mm / AISI 316L Antenna Extensions A ------ B 200mm C 500mm D 1000mm E 2000mm X Special type (On request) Connections / Material FA Flange DN50 PN16 AISI 316L FB Flange DN80 PN16 AISI 316L FC Flange DN100 PN16 AISI 316L FD Flange DN150 PN16 AISI 316L FE Flange DN200 PN16 AISI 316L YP Special type (On request) Retained seal / Working Temperature 2 Viton / -40 130 C 3 Kalrez / -20 130 C 4 Viton / -40 200 C with heat dissipator 5 Kalrez / -20 200 C with heat dissipator Electronic B 4 20 ma 2 wires C 4 20 ma / 22,8 26,4 VDC / HART 4 wires D 4 20 ma / 198 242 VAC /HART 4 wires Housing Material / Protection B Plastic / IP67 A Aluminium / IP67 D Aluminium (2 chambers) / IP67 G AISI 316L / IP66 / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A Yes Sweeping System A Yes X No

Important Notices for CW53 The size of the antenna CANNOT be smaller than the size of the flange or viceversa. If the antenna is bigger than the flange (nozzle) hole, the antenna cannot fit in. Example: Horn Antenna Ø 150mm code "F" CANNOT be matched with Flange DN100 PN16 code "FC" The size of the flange refers to GB/T9119-2000 PN16. the thickness of the flange is 15mm. DN100 flange is suggested when Parabolic Antenna is chosen The user has to build the flange with the same size of the Parabolic Antenna With sprayed PTFE Antenna, please use a sprayed PTFE flange with larger size