Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large



Similar documents
X-ray Imaging Systems

X-ray Imaging Systems

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

X-Mind. Instinct for perfection

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Halogen Lamps. Lamp Construction

DU 694. Technical Data Specifications (888-59) (889-03) PX 1494: (874-53) (874-57) (874-54) (874-58) (874-55) (874-59) (874-56) (874-60)

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

CELO5. User & Installation Manual.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

IR Edixeon Emitter. 1W Edixeon

T Substation Maintenance and Commissioning Test Equipment

Fuse Selection Method Module 2. Date of the presentation

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Operating Instructions Bedienungsanleitung Mode d emploi

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

PowlVac Vacuum Integrity Tester

Waveguide Access Point WGA631. Product Guide

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

CERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS

Product and functional description

SMD Rework Station TABLE OF CONTENTS

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

VACUUM CLEANER INSTRUCTION MANUAL

Installation Instructions. ThermoCall TC4. Entry/Advanced

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Guideline Laser Series

Owner s Manual

GLOBO 30 HANGING design SLIDE Studio

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

T5 LongLast. GE Lighting DATA SHEET

Pocket Tach 99 (PT99) Non-Contact Tachometer

RM4TG20 three-phase network control relay RM4-T - range V

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Adjustable room thermostat for heating only or cooling only systems

Operating Instructions Drill rig DRU160

CUBO 20 HANGING design SLIDE Studio

50 W Power Resistor, Thick Film Technology, TO-220

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Discontinued. LUXEON V Portable. power light source. Introduction

Part Marking Instructions Chip Resistors

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

JB-70 Dental X-Ray System

Kolorlux. GE Lighting DATA SHEET

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

1 Form A Solid State Relay

GLOBO 30 design SLIDE Studio

UT202A Operating Manual. Contents

Replacing the vacuum tube

08. SEK IDC CONNECTORS

Power Resistor for Mounting onto a Heatsink Thick Film Technology

BB-18 Black Body High Vacuum System Technical Description

Features. High Brightness LED Light source

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

DS 600. A contact free flux gate based current measurement sensor 600A rms

LED DOWNLIGHT ONE 50XX SERIES

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

CILINDRO 40 design SLIDE Studio

ALI BABA PIANTANA (H165) design SLIDE Studio

CUBO 20 design SLIDE Studio

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Installation Instructions. Thermo Call TC3

FRC Series 35mm Diameter Reflectors for SEOUL SEMICONDUCTOR A3 (Acriche) and P7LEDs

ADM1TE 5/30A DIN rail single phase two wire energy meter

T5 Watt-Miser Linear Fluorescent lamps

SURGE PROTECTIVE DEVICES

user's manual _19

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLN Series. MLN SurgeArray TM Suppressor. Description

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

TRIMMING UNIT/DIAMOND MACHINE TST.13

LED Standard lamps LED Candle lamps LED Ball lamps LED Spot lamps

Tungsten Tip Preparation

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Installation Instructions for Alarm Module Kit A043F059

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

Comparative study for cables and busbars

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

PIVOT GLOBO design SLIDE Studio

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

GLOBO 30 design SLIDE Studio

aseries A13B Mini Bullet Camera User Manual

No. STSE-CW2163B <Cat.No > SPECIFICATIONS FOR NICHIA WHITE LED MODEL : NSPW315BS NICHIA CORPORATION -0-

Drayton Digistat +2RF/+3RF

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

Q1. (a) The graph shows the temperature inside a flat between 5 pm and 9 pm. The central heating was on at 5 pm.

UV100A Ultraviolet Air Treatment System

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Laserlyte-Flex Alignment System

1/2 GLOBO 40 design SLIDE Studio

Redundancy Module QUINT-DIODE/40

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Transcription:

TECHNICAL DATA GENERAL INFORMATIONS Voltage nominal maximum for test 1 135 kv When mounting tube inserts adopt proper caution, in order to avoid glass bulb breaking and fragments projection. Please use protective gloves and glasses. Tube insert connected to H.V. supply is a radiation source: be sure to take all necessary safety cautions Inverse voltage Focal spots (IEC 6336:5) nominal maximum for test small large 1 135.5 1.5 kv mm Wash thoroughly with alcohol the external surface of tube insert (care of fire risk). Avoid contact of dirty surfaces with cleaned tube insert. Clamp system inside housing or self-contained units must not mechanically stress the tube. After installation, check the right working of the tube (no fluctuation of tube current nor crackling) Filament characteristics small large 2.4 4. V 3. 4. A 4. 8. V 3.5 4.5 A Anode material tungsten Target angle 12 Anode heat storage capacity 3* J Maximum anode cooling rate 27* W Comply with insert thermal parameters, planning and programming the exposure parameters and cooling pauses. Housing or self-contained units must be provided with an adequate thermic protection. Voltages indicated in charts are valid for transformer supplied with ground center. Tube inserts contain environment polluting materials, particularly lead liner tubes. Please apply to qualified operator for waste disposal, according to local regulation requirements. Nominal anode input power at.1 s (DC) small 78 large 4 W Inherent filtration.5 mm Al Maximum diameter 5 mm Overall length 155* mm INCIDENT REPORT ACCORDING TO 93/42/EEC MEDICAL DEVICES DIRECTIVE In order to comply with CE marking requirements, end users have to report to local Competent Authority all the informations about possible incidents involving the device, regarding any deterioration in its characteristics and performances, as well as any inaccuracies in this documentation, which might lead to or might have led to the death of patient / user or a deterioration in his state of health. This information must be promptly reported also to C.E.I. in order to start manufacturer reporting, as per above mentioned directive. * with standard shank. On every kind of shank it is possible to make customized millings for the allignement of the tube. 459 this mark assures device conformity to EC Directive 93/42 on Medical Devices Safety Rev.I 412 Original text: Italian Pag. 1 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy

DIMENSIONS AND CONNECTIONS STD SHANK (Anode heat storage capacity 3 kj, Maximum anode cooling rate 27 W) large focus - red common - black Small focus-yellow raggi X THERMAL CURVES Heat storage (J) INSULATING CYLINDER LEAD Time (s) Rev.I 412 Original text: Italian Pag. 2 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy

DIMENSIONS AND CONNECTIONS LONG SHANK (Anode heat storage capacity 33 kj, Maximum anode cooling rate 28 W) large focus - red common - black Small focus-yellow raggi X THERMAL CURVES Heat storage (J) LEAD INSULATING CYLINDER Time (s) Rev.I 412 Original text: Italian Pag. 3 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy

DIMENSIONS AND CONNECTIONS RADIATOR (Anode heat storage capacity 4 kj, Maximum anode cooling rate 5 W) large focus - red common - black Small focus-yellow raggi X Heat storage (J) INSULATING CYLINDER Time (s) LEAD Rev.I 412 Original text: Italian Pag. 4 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy

EMISSION CHARACTERISTICS FILAMENT CHARACTERISTICS DC 24 4.2 SMALL FOCAL SPOT (.5 IEC 336) 16 16 12 7 kv 7 kv 12 8 8 4 4 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 Filament current (A) 4.1 4. 3.9 3.8 3.7 3.6 3.5 3.4 3.3 3.2 2.4 2.8 3.2 3.6 4. LARGE FOCAL SPOT (1.5 IEC 336) 1 8 6 7 kv 4 4. 5. 6. 7. 8. 1 1 8 7 kv 6 4 4. 5. 6. 7. 8. Filament current (A) 4.5 4.4 4.3 4.2 4.1 4. 3.9 3.8 3.7 3.6 3.5 4. 5. 6. 7. 8. Rev.I 412 Original text: Italian Pag. 5 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy

MAXIMUM RATING CHARTS DC SMALL FOCAL SPOT (.5 IEC 336) LARGE FOCAL SPOT (1.5 IEC 336) 4 kv 5 kv 6 kv 7 kv 8 kv 9 kv 1 kv 11 kv 1 kv 4 kv 5 kv 6 kv 7 kv 8 kv 9 kv 1 kv 11 kv 1 kv Rev.I 412 Original text: Italian Pag. 6 di 6 C.E.I. Srl via della Tecnica 3 San Lazzaro di Savena BOLOGNA - Italy