HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS



Similar documents
CONTENTS 4. HOW TO UNSET THE PANEL...7

Control/Communicator Installation Manual

ICP-CC488. Installation Guide ICP-CC488 Control Panel

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

GE Concord 4 Quick User Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

MICROPROCESSOR HOME - SECURITY SYSTEM Home4

ICP-CP500. User's Guide ICP-CP500 Codepads

ACTIVE 5 ENGINEERING MANUAL

NESS D Zone Control Panel and Dialler OWNER S MANUAL

AUTODIALLER / QUICKDIALLER - SA132

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

DC-8706K Auto Dial Alarm System

Solution 880 Operators Manual ISSUE 1.10

User s Information Guide R1A

INSTALLATION MANUAL PC2525. Version 1.1

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

Business/Home GSM Alarm System. Installation and User Manual

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

SECTION DETECTION AND ALARM

TS510 & TS500. Installation & User Guide. Compatible Equipment

IDS X-Series User Manual D Issued July 2012

GSM ALARM SYSTEM USER MANUAL

Users Guide to Keypad Functions

1R / 4-BUTTON SERIES

Ademco Vista-20P/First Alert FA-168C Basic Commands

WIRELESS HOME ALARM SYSTEM (WHA1)

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

9452/9453 Installation and User Guide

TABLE OF CONTENTS FEATURES

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Using your LED Plus keypad

500r+ Installation and User Guide


Wireless Alarm system s manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

How To Program An Autodialer

Solution 862 Operators Manual. Issue 1.00

VR8. User Guide Intruder Alarm System

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Wireless Home Security Alarm System AM 500

Intelligent GSM Auto-Dial Alarm System

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

PhoneWatch Smart Security System User Manual - Domonial

WITURA CORPORATION SDN BHD

Reference & Installation Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Solution-16 Operators Manual ISSUE 1.60

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

616, 626, 636 & 646 Keypads

Fire Alarm Control Panel. Family. Operating Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Vision Security System OWNER MANUAL V-LCD1

Using Your. Security System. With LED Keypad S5030, S5031, S5032

SECURITY SYSTEM NOTES

SECURITY SYSTEM NOTES

Using Your. Security System With Icon Keypad S5020, S5021, S5022

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

MOBILE CALL GSM Alarm System User s Manual

SECURIT 800L+ CONTROL PANEL

Auto Dialer. Manual E-921APQ E-921GPQ

GSM Home Alarm system. User Guide

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

Wireless Home Security System Product Manual (Model #80355)

Manual for Fire Suppression & Methane Detection System

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

INSTALLATION MANUAL CONTENTS

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

VEHICLE SECURITY SYSTEM G25/G20

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

GSM Home Alarm System User Manual.

Automatic Telephone Dialer TD-101(W)

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

System Introduction S E C T I O N 1

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

INSTRUCTION MANUAL PC255O

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

GSM HOME SECURITY SYSTEM

SECURIT 800L+ CONTROL PANEL

MotorCycle Alarm by DEF COM 3 INSTALLATION MANUAL 80 C

PK5500 v1.1 Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SECURITY SYSTEM NOTES. Security System Configuration

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

ADEMCO LYNXR-I Security Systems

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

WD-AMX Water Detection Controllers

Intruder alarm system Engineering Information

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5

Transcription:

ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL

USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete alarm control panel designed for commercial and residential security systems and equipped with the latest electronic control technology. It has the highest level of quality and reliability. The exceptional specifications incorporate many features that are generally only found in advanced professional systems. The (HA-841K) accepts active and passive sensors/detectors to form a versatile protection system. ADJUSTS DURATION OF 24 HOUR PANIC/FIRE SIREN ADJUSTS DURATION OF BURGLARY SIREN ADJUSTS DURATION OF ENTRY DELAY ALARM STATUS INDICATOR CABINET LOCK POWER ON-OFF KEY SWITCH 24-HOUR PANIC BUTTON TEST/OPERATE SELECTOR MAIN POWER ON-OFF SWITCH NOTES FOR INSTALLING TECHNICIAN CONNECTION TERMINALS (SEE DESCRIPTION FOR DETAILED INFORMATION ) BATTERY COMPARTMENT WIRE FEED- THROUGH HOLES The panel is extremely reliable. Use the check list at the back of the manual in case of trouble. Recheck all the wiring if the list does not help. 1. Main Power Switch : Enables the user to disconnect or connect the power. INTERNAL CONTROLS 2. Test/Operate Switch : This switch allows the installer to test the panel without activating the siren or the relays. In the test position the siren is replaced by the internal buzzer that beeps "2 seconds on 1/4 second off" during the alarm period. This switch should be placed in the" operate" position for the siren and relays to operate normally. 3. Duration Siren 24h / Panic Function / Fire : Determines the length of time the siren will sound before resetting when it is triggered by the 24hr instant-alarm circuit. This circuit is adjustable from 30 sec. to 3 min. 4. Siren Duration / Burglary : Determines the length of time the siren will sound before resetting when it is triggered by the N.C. (Normally Closed) instant-alarm circuit or by the N.C. or N.O. (Normally Open) delayed-alarm circuits. The activation period is adjustable from 30 sec. to 3 min. 5. Entry Delay : Determines the duration of the delay : from 0.5sec. to 90sec. 6. Key Switch : Switches alarm circuits on/off and does not affect the 24hr instant-alarm circuit. 2

7. Panic Button : Connected internally to the 24hr instant-alarm circuit. Pressing this button will activate the siren, regardless the position of the key switch. LED INDICATIONS Exit / Armed (GREEN) : This LED indicates the status of the alarm. The exit period (60 sec.) begins when the key switch is put in the "on"- position. The LED will flash and will then remain lit continuously when the exit period ends. The Exit/Armed LED will be extinguished if either the instant-alarm circuits or delayed-alarm circuits are activated (RED). The function of this LED is duplicated on terminal 4 so that remote indication can be used. Instant-alarm Circuit LED (RED) : This LED will light whenever either of the instant-alarm circuits (24hr or N.C.) is operated while the key switch is in the "on"-position. Delayed-alarm Circuit LED (RED) : This LED will light whenever either of the delayed-alarm circuits (N.O. or N.C.) is operated while the key switch is in the "on"-position. Alarm Memory LED (GREEN) : This LED will light when the alarm is triggered and will remain lit until the main power switch is turned off or until the key switch is turned "off-on-off". The alarm was triggered in your absence if this LED is lit. Battery-Low LED (GREEN) : This LED will flash once every 2 sec when the battery voltage drops below 11.5 Volts. AC Power LED (AMBER) : This LED indicates that power is supplied to the panel (main power switch is in the "on"-position). It should remain lit continuously. The backup battery will supply the necessary power if the main power switch is in the "on"-position and this LED is not lit. Restore the primary power source as soon as possible. INTERNAL WARNING TONES Exit Delay Period* - Short "BEEP" at 1/2 second intervals Entry Delay Period - 2-second "BEEP" at 1/4 second intervals Battery-Low Indication - Short "BEEP" at 2-second intervals Alarm Test Mode - 2-second "BEEP" at 1/4 second intervals Tamper Alarm - 2-second "BEEP" at 1/4 second intervals (Short 20-21 to deactivate the alarm) Horn Speaker Wire Is Cut - 2-second "BEEP" at 1/4 second intervals (1K resistor between 11-12 to deactivate the alarm) * if terminals 11 & 12 are connected by a 1KΩ resistor 3

CONNECTIONS Terminal 1 & 2 : 24 hr instant-alarm circuit This circuit is monitored round the clock and is unaffected by the alarm key switch. This is a normally open circuit. It can be used for fire and smoke detectors, panic switches and tamper circuits. Note : these two terminals must remain open, i.e. no connection should exist between 1 & 2 when all switches and sensors are in their normal reset positions. PANIC SMOKE/FIRE SENSORS FIG.1 : 24HR INSTANT-ALARM CIRCUIT N.O. CONTACTS SHOULD BE WIRED IN PARALLEL Terminal 2 & 3 : N.C. Instant-alarm Circuit This circuit is controlled by the alarm on/off key switch. Use it to connect any area that requires protection without using a delay between detection and the sounding of the siren - motion sensors, window switches, window foil tapes etc. can be connected here. The contacts of these sensors should be shorted when in the normal reset condition and they should be arranged in a series loop (see figure 2). ALARM SENSOR CONTACTS N.C. CONTACTS SHOULD BE WIRED IN SERIES FIG. 2 : N.C. INSTANT-ALARM CIRCUIT Terminal 4 : Alarm status indication Terminal 4 allows the connection of a low-current LED with the same function as the Exit/Alarm LED. It can be used on external key switches in order to provide an indication of the alarm status. The cathode terminal (normally indicated by a small flat on the plastic body adjacent to the lead. The cathode is the shorter of the two leads of this LED) is connected to terminal 4 and the anode terminal is connected to the positive power connection (terminal 21). This circuit does not require a resistor as the control panel is equipped with an internal resistor. Reverse the connections and try again if the LED does not work. LEDs are available from electronic supply stores. 1K - CATHODE SMALL FLAT ANODE INTERNAL CATHODE LED ANODE CATHODE FIG. 3 : REMOTE ALARM STATUS INDICATOR 4

Terminal 5 & 6 : N.C. Delayed-alarm Circuit This circuit is controlled by the alarm on/off key switch. It should be used for any area requiring a delay between the moment of detection and the activation of the siren. These contacts should be N.C., i.e. terminals 5 & 6 should be shorted under normal circumstances. The delay is adjustable from 0.5 sec to 90 seconds by using the control marked "entry delay". ALARM SENSOR CONTACTS FIG. 4 : N.C. DELAYED-ALARM CIRCUIT Terminal 6 & 7 : N.O. Delayed -alarm Circuit This circuit has the same function as 5 & 6 but it is a N.O. circuit : the contact must be open under normal circumstances. Ideal for pressure mats. ALARM SENSOR CONTACTS FIG. 5 : N.O. DELAYED-ALARM CIRCUIT Terminal 9 & 10 : Connections for Internal Battery Charger These terminals should be linked to connect the internal battery charger to a rechargeable battery (we strongly advise you to use a 12V rechargeable battery). LINK 9 & 10 for RECHARGEABLE BATTERY DO NOT CONNECT WHEN USING STANDARD BATTERIES FIG. 6 : CONNECTIONS FOR RECHARGEABLE BATTERY 5

Terminal 11 & 12 : Siren speaker output These terminals provide a high-level siren signal that drives up to two 8 ohm (horn) speakers. Shorting these terminals or using more than 2 speakers will result in serious internal damage. The control panel has an internal alarm that will sense when the speaker wires are cut. Consequently, the 1K ohm resistor installed across the terminals should be left in place if no speaker is connected. Remove this resistor if a speaker is connected. LINK 11 & 12 WITH A 1K OHM RESISTOR IF NO SPEAKERS ARE CONNECTED 8 OHM SPEAKERS (MAX. 2!!) FIG. 7 : CONNECTION FOR SPEAKER SIREN Terminal 13 & 14 : Alarm relay contact This is a single contact that shorts when the alarm sounds and deactivates when the alarm resets. It can be used to switch strobes and self-contained sirens, etc. Power is taken from terminal 10 and switched through the relay contact. Note : A max of 1Amp is available at terminal 10. Use an external supply when more current is needed. The max. current is 3 Amps (see figure 9). STROBE / SIREN, etc. FIG. 8 : ALARM RELAY CONNECTION EXTERNAL SUPPLY MAX. 3 AMPS FIG. 9 : RELAY CONNECTION FOR HIGHER CURRENT/VOLTAGE 6

Terminal 15 & 16 : Alarm memory relay contacts These contacts operate at the same time as the alarm relay contact. However, the contacts remain activated until the power is turned off or the alarm key switch is turned "off-on-off" (same as the Alarm Memory LED). It can be used to provide an external indication of the fact that the alarm has been triggered (alarm memory). Again, the max. current for the contact is 3 Amps. Power is connected in the same way as with terminals 13 and 14. 1AMP MAX. LIGHT FIG. 10 : ALARM MEMORY RELAY CONNECTION - REMOTE ALARM MEMORY INDICATION Terminal 17 & 18 : Power input The polarity of these terminals is irrelevant if you have a 16V AC panel. Simply connect the two wires from the plug pack to these terminals. If you have a 12V DC panel, you should be careful to connect the power supply using the correct polarity : terminal 17 is positive (+), terminal 18 is negative (-)*. IMPORTANT : The standard Velleman version of this product is supplied with a 13.8VDC power supply!!! If you do not know which type of panel you have, you should check the area behind the terminals under the main circuit board. If you have a 16V AC panel, you will find a small auxiliary circuit board of approx. 50 x 25mm in this area. * Note : the DC input voltage should be 13.8V (or 14V) to ensure correct charging of the battery. + - 16VAC OR +VE 13.8VDC -VE FIG. 11 : POWER INPUT CONNECTION FOR AC OR DC POWER SUPPLY 7

Terminal 19 : Switchable power output This terminal provides a 12V DC output of max. 0.5 Amps that is switched by the alarm on/off key switch. It can be used to supply ultrasonic or microwave motion detectors, etc. Avoid connection of infrared detectors to a switchable power supply. The PIR detectors should be connected to a permanent 12V power supply (terminal 21) in order to ensure stable and reliable operation. Connect the PIR detectors as follows : Positive connection (+) of the PIR detector to terminal 21 and the negative connection (-) to terminal 6. MICRO WAVE / ULTRASONIC DETECTORS CONNECT INFRARED DETECTORS TO TERMINAL 21 INSTEAD OF 19 + 500mA MAX FIG. 12 : TERMINAL FOR SWITCHABLE 12V POWER SOURCE Terminal 20, 21 and 8 These terminals are used for remote key switches. If no remote key switch is used, terminals 20 and 21 should be shorted in order to disable the internal alarm that senses wire cutting. There are two ways to connect a remote key switch to the panel. Both methods (see diagram) will activate an internal alarm if the wiring is cut. METHOD 1 FIG. 13 : REMOTE KEYSWITCH WITH CUT WIRE PROTECTION METHOD 2 TERMINALS 20 & 21 MUST BE LINKED FIG. 14 : REMOTE KEYSWITCH WITH CUT WIRE PROTECTION The key switch on the panel should be left in the "on"-position when an external key switch is being used. Both methods of remote key switch connection are secure : the alarm will be activated if the wiring is cut. 8

PROBLEM CHECKLIST PROBLEM POSSIBLE CAUSE BEEPER KEEPS SOUNDING - Verify whether the speakers are connected - When no speakers are used, the 1Kohm resistor should be connected across terminals 11 & 12 - Terminals 20 & 21 are not linked - Weak battery - "Test/Operate"" switch is in the "Test"-position - Beeper sounds during exit period INSTANT LED PERMANENTLY ON - Terminals 1 & 2 are shorted (should be open) - Terminals 2 & 3 are open (terminals 2 & 3 should be shorted if the alarm is not activated) DELAY LED PERMANENTLY ON - Terminals 5 & 6 are open. They should be shorted if the alarm is not activated. - Terminals 6 & 7 are shorted (should be open) LOW BATTERY INDICATION - Terminals 9 & 10 are not linked (should be linked in order to charge the battery) When using standard batteries, do not link terminals 9 & 10 to the battery (use a 12V rechargeable battery) SIREN WILL NOT SOUND - "Test/Operate" switch is in the "test"-position - Wiring is cut - 1Kohm resistor has not been removed INSTANT-ALARM/DELAYED-ALARM CIRCUITS DO NOT WORK - Key switch is not in the "on"-position - Incorrect wiring : N.O. switch is wired in series or N.C. switch is wired in parallel CONNECTION TERMINALS FIRE/SMOKE SENSOR N.C. SWITCHES N.C. SWITCHES N.O. SWITCHES 24 HOUR N.O. INSTANT N.C. INSTANT REMOTE ALARM STATUS N.C. DELAY N.O. DELAY RECHARGEABLE BATTERY : CONNECTED NORMAL BATTERY - OPEN BATTERY CHARGER INTELLIGENT SIREN DRIVER OUTPUT + - 8 Ω HORN SPEAKER (MAX. TWO) OUTPUT FOR ALARM RELAY CONTACT (3AMP MAX.) OUTPUT FOR ALARM MEMORY RELAY CONTACT (3AMP MAX.) POWER IN : SEE TEXT 12VDC (+) ON OFF REMOTE KEY SWITCH WITH CUT WIRE PROTECTION 9