Excool grows rapidly as datacenter operators seek greener, cheaper cooling



Similar documents
Virtus serves up colocation on demand in London, readies second datacenter

Integrated and federated: TDB Fusion aims to bring seamless management to datacenters

Vigilent shows market awareness with datacenter dynamic cooling update

London's VIRTUS breaks the traditional colocation mold

Guide to Minimizing Compressor-based Cooling in Data Centers

Smart Carbon Control sets out to make datacenter data meaningful

Server room guide helps energy managers reduce server consumption

FNT sets out its ambition: to be the ERP for infrastructure service providers

Three Steps To Perfectly Green

AIRAH Presentation April 30 th 2014

FNT enters US, Asia with broad DCIM suite

ITB2 Datacenters Informationbrochure 2015 Page: 2

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Technical Systems. Helen Bedford

Elliptical Mobile positions its micro-modular datacenter design for larger sites

White Paper: Free Cooling and the Efficiency of your Data Centre

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

System solution for data centres

The Intelligent Data Centre

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

The Use of Fresh Air in the Data Centre

Free Cooling for Data Centers

DATA CENTERS BEST IN CLASS

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Data Center Cooling Systems Market ( ): Liquid. Cooling Types (In-Row, Overhead, Rear Door, In-Rack); Air

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Expert guide to achieving data center efficiency How to build an optimal data center cooling system

CASE STUDY: COOLERADO CORPORATION

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

Datacenter Efficiency

Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014

Global MTDC provider IO introduces London to its modular datacenter proposition

Greening Commercial Data Centres

Raising Inlet Temperatures in the Data Centre

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

HVAC Infrastructure Retrofit Solutions

European Code of Conduct for Data Centre. Presentation of the Awards 2016

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Global Case Studies in Highly Efficient Datacenters 2014

ALWAYS ON GLOBALSWITCH.COM

Colocation, Hot Seat Services, Disaster Recovery Services, Secure and Controlled Environment

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

VISIT 2010 Fujitsu Forum Europe 0

VIRTUALIZING BUSINESS-CRITICAL APPS. Maximizing Business Value: Strategies for Virtualizing Business-Critical Applications

Technologies Course Number: CXENERGY1521

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

2016 Trends in Datacenter Technologies

Global Headquarters: 5 Speen Street Framingham, MA USA P F

How To Find A Sweet Spot Operating Temperature For A Data Center

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Increasing Energ y Efficiency In Data Centers

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

Arista shakes up data access management with DANZ

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Direct Fresh Air Free Cooling of Data Centres

Eco4Cloud: Consolidate virtual machines to accumulate datacenter savings

BEST PRACTICES RESEARCH

Microsoft Technology Center: Philadelphia

Data Center RD&D at EPRI

Insourcing vs. Outsourcing. Bart Leung Senior Associate, Ehvert Mission Critical

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

European Code of Conduct for Data Centre. Presentation of the Awards 2013

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

European Business Reliance Centres when Commodity serves Green IT

Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty

Analysis of data centre cooling energy efficiency

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Premium Data Centre Europe Pricing, Business Model & Services

Data Center Infrastructure Management - a special report

Data Centre Harbour Exchange Square Campus, London Access to unrivalled connectivity.

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Multifamily Central Heat Pump Water Heating

Improving Data Center Energy Efficiency Through Environmental Optimization

Data centers have been cooled for many years by delivering

Data centres that deliver

Dell s Next Generation Servers: Pushing the Limits of Data Center Cooling Cost Savings

WHITE PAPER Delivering Improved Energy Efficiency for the Datacenter

The Mission Critical Data Center Understand Complexity Improve Performance

Chiller-less Facilities: They May Be Closer Than You Think

Interested in conducting your own webinar?

Reducing Data Center Energy Consumption

Energy Efficiency and Availability Management in Consolidated Data Centers

Award-Winning Innovation in Data Center Cooling Design

European Code of Conduct for Data Centre. Presentation of the Awards 2014

LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING

Global Temperature Test Chambers Industry 2016 Market Research Report

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Data Centre Cooling Air Performance Metrics

THE WORLD S MOST EFFICIENT DATA CENTER

Energy-Saving Promotion Services

DAikin Altherma low temperature heat pump. end user leaflet

Data Center Equipment Power Trends

Enabling an agile Data Centre in a (Fr)agile market

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Transcription:

Excool grows rapidly as datacenter operators seek greener, cheaper cooling Analyst: Andy Lawrence 8 Jul, 2014 The move toward environmentally friendly and energy-efficient datacenters is a threat to some and an opportunity for others. Excool, a UK specialist in free cooling, is growing rapidly as demand for its precision-engineered indirect air economizer picks up. The company has won contracts with major datacenter operators and moved into expanded new manufacturing facilities; it is currently planning its move into the US market, most likely through a close partnership. The company also has undisclosed plans to significantly expand its datacenter product line. The 451 Take There is no de facto standard cooling system or technology for the datacenter of today and tomorrow, and there almost certainly won't be. But indirect free air economizers are being increasingly used, especially in mission-critical datacenters where there is some caution around using direct air. With its carefully engineered technology, Excool has carved out a strong position in spite of competition. The company's big strengths are its knowhow and proven capability, rather than any technology breakthrough. Through fine-tuning and experience, it has driven up the efficiency of its heat exchanger and identified which materials are the most resilient, and which sizes and formats most suit the needs of datacenter operators. Its biggest challenge now is execution exploiting the strong, global demand over the next decade. Competition can only intensify. Copyright 2014 - The 451 Group 1

Context Excool is not yet a well-known name in datacenter cooling, but its rapid expansion, high-profile customers and likely move into the US in the next year are likely to change that. Excool is the fastest-growing of four divisions in the IET group, Integrated Eco Technologies; the others are IPT, EcoAir Box, and Mercury Climatic Controls. The company, founded in 1983, is privately held and controlled by founder Duncan Williams. It has grown rapidly over the past two years as sales in the datacenter sector have taken off. The move into the datacenter industry was triggered by an apparently arcane decision made by technical experts on the other side of the Atlantic and which it initially missed. In 2008, the ASHRAE TC.9.9 committee widened the recommended temperature range for server inlet temperatures to 18-27 degrees Celsius (64 F and 81 F). It later introduced yet wider 'allowable' ranges of 15-32 degrees (59-90 F). Excool's engineers later realized that this had big implications for datacenters and opened up new opportunities for the company. The company had already been readying an energy-efficient cooling system for cellular base stations when the specifications changed and rendered its research and development effort irrelevant. The ASHRAE decision, however, changed that. It meant that, in most geographies, it would be feasible and economic to use a cooling system, even for large and relatively high-density datacenters, that uses little or no mechanically aided cooling (almost all datacenters today use expensive and energy-hungry compressors to drive the cooling cycle). Having identified the market in datacenters, Excool spent more than two years honing its product. At its site near Birmingham, in the UK, it built a full-scale model and test chamber so that that it could be sure that the system could handle the workload and its service-level promises could be met. This has proved critical in persuading those building large Tier III datacenters that the technology is up to task. The Excool system was effectively launched in 2012, after extensive testing. The company, now in its third year of sales, does not disclose revenue, but 451 Research estimates this to be in the 15m-25m ($25m-42m) range. This represents rapid growth when compared with other cooling product suppliers, we believe. Like others, Excool is wary of mentioning customer names, although it has shipped more than 21MW of cooling capacity. Among Excool's publicly disclosed customers are Virtus Data Centres, PEER 1, Rackspace/Digital Realty in the UK and ITB in the Netherlands. Copyright 2014 - The 451 Group 2

The company currently provides its cooling systems to datacenter operators in Northern Europe, but is seeking a partner in the US. It is considering a range of options, which could include forming a partly owned US company with an investment company or a company in the datacenter industry. Technology Excool's technology is based on the well-established principles of adiabatic and evaporative cooling techniques used in industry since the 19th century. By a combination of spraying atomized water into air as it is sucked into a datacenter, lowering its temperature, and the loss of temperature associated with evaporation, outside air can be cooled sufficiently to then reduce the temperature of the warm air from the IT equipment in the datacenter. While some free air cooling systems use filtered outside air and circulate it within the datacenter, Excool uses indirect cooling. This means the outside air and the internal datacenter air never mix. The key to this technology, and a critical component in Excool's recent success, is the efficiency of the heat exchanger. Excool claims its heat exchanger an apparently low-tech PVC device consisting of separated air passages that cross each other (exchanging heat) is more efficient than any other available, and is longer-lasting, more resilient and requires no maintenance. As an example of that efficiency, if the return air from the datacenter equipment is 36 C, and the outside air is 16 C, Excool says it can transfer 80% of that heat outside the datacenter. That means the air inside the datacenter is recirculated back the IT equipment at 20 C. Other systems on the market may only achieve 60% efficiency, which means the supply air would be at 24 C. When equipment is operating near the limits of the ASHRAE ranges, or of service-level agreements, these efficiencies can be critical, and could make the difference between the need to ever use a mechanical compressor. Excool's units are about the size of a shipping container, and are available in modular units of 140kW-400kW. Some of Excool's customers are Tier III certified. Availability is achieved through an N+1 configuration all the units are used at energy-efficient low fan speeds, but if one breaks down, the remaining units can be sped up. Business benefits The benefits of using Excool depend on how much cooling can be achieved without mechanical cooling, on the risk appetite of the operator and on the service-level agreements that datacenters offer (many operators agree to keep in the middle or low end of the ASHRAE range, so that equipment reliability is not compromised). But even relatively risk-averse datacenters can save Copyright 2014 - The 451 Group 3

significantly on mechanical cooling equipment (those less risk-averse can eliminate it altogether), in addition to reducing their overall energy consumption. Excool argues that diesel generator size can be reduced by 60% and transformer size by 70% figures that are impressive, but will depend on the situation. In cost comparisons with other datacenter cooling methods, Excool claims that its systems cost 15% less than an equivalent chilled water system, but the operational cost is 90% less adding up to a 75% reduction over the total life. Cost comparisons with direct outside air systems are less straightforward, depending on how much mechanical cooling is installed as a backup (direct air systems may need to close down if there is an air-quality issue, so backup cooling systems may need to be in place). The Excool system (like some others) is under software control so that it can automatically select the cheapest method of cooling air only (winter); with evaporative (summer); or, in extreme situations, with mechanical cooling. Those operators electing not to install any mechanical cooling will save significantly but even those that want some safety margin are able to install just enough to bring the temperature back within ASHRAE limits the free cooling will still do a lot of the work. Competition A variety of competing products have appeared on the market from 2009 through to today, using greater or lesser degrees of free economization. Not all the products, however, are the same, and relatively small differences in capacity or efficiency can make a significant difference in economics and viability, especially in situations where the datacenter is operating on the margins, since they often are in hot weather. One German-based supplier, Munters, competes head-on with similar technology, and has been enjoying similar success. Datacenter equipment giant Schneider Electric supplies an indirect evaporative cooling product, EcoBreeze, that is delivered as an external container (it has used some of Munters' technology in this product). Another supplier, KyotoCooling International, acquired in 2013 by Cloudsite Intelligent Data Centers, has a somewhat different approach it has enjoyed some success using a large circulating wheel as a heat exchanger. Emerson, owner of the Liebert line of cooling products, tends to offer mechanical cooling with free air options to reduce operational costs. There are also various other smaller suppliers, including some self-designed products. Some of the modular datacenter providers have developed or at least commissioned their own free cooling Copyright 2014 - The 451 Group 4

systems BladeRoom Group, for example, has a direct cooling system, while AST Modular, now part of Schneider, has an indirect cooling system. Some larger colocation and Internet-scale operators have developed their own one example is the large Switch NAP datacenter in Las Vegas, which uses a large-scale evaporative cooling system. SWOT Analysis Strengths Weaknesses Excool has an efficient, resilient and cost-effective cooling system that is proven in high-availability datacenters. It is (currently) focused on cooling. Opportunities Threats There is a growing consensus that indirect free cooling, with adiabatic and evaporative cooling, is the most efficient way to cool a large proportion of new commercial datacenters. The market is large and growing. Excool is still a small company with limited resources compared with some of the big equipment operators. Its cooling systems may only be suited to a part of the datacenter market (albeit large and growing). It does not yet have operations in the largest market (US) or the one with the most potential (China). The datacenter market is changing. Power densities are not growing (reducing the need for so much cooling) and datacenters are likely to be increasingly operated below peak, reducing the cooling capacity required. While this may benefit free cooling in some situations, new designs may have lower cooling needs or different requirements. Copyright 2014 - The 451 Group 5

Reproduced by permission of The 451 Group; 2014. This report was originally published within 451 Research's Market Insight Service. For additional information on 451 Research or to apply for trial access, go to: www.451research.com Copyright 2014 - The 451 Group 6