Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts 16A Module-1 09.27.07 Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW +20V Lutron s Dimming Power Module allows integration of Lutron s 3-wire phase controlled dimming ballasts into Lutron s Bus (Eco-10TM and Hi-lumeTM series only). The Power Module combines digital commands and sensor data to determine the proper light level. Features Continuous, flicker-free dimming from 100% to minimum ballast level. (10% for Eco-10, 5% for Compact SE, 1% for Hi-lume) Provides 20 V power for and responds to one occupant sensor, one photo sensor, and one personal control input (infrared receiver or wallstation) Communicates status and sensor levels over the Bus Universal voltage input: 100-277 V 50/60 Hz Non-volatile (EEPOM) memory stores specific system information for 10 years from power down to power restored 100% performance tested at factory One-Line Bus To additional ballasts and modules (up to 64 total) Ballast eceiver 1 2 3 4 5 6 7 8 Bus Supply* Occupant Sensor Dimming Power Module Eco10TM or Hi-lumeTM Ballast* Ballast Ballast Sensor Lighting emote Keypad *Does not count as one of the ballasts or modules on the Bus.
Specifications Dimming Module 16A Module-2 09.27.07 Standards UL 916 Listed and CSA 184 Certified Meets ANSI C62.41 Category A surge protection standards up to and including 6 kv Manufacturing facilities employ ESD reduction practices that comply with the requirements of ANSI/ESD S20.20 Lutron Quality Systems registered to ISO 9001.2000 Power Operating Voltage: 100-277 V~ 50/60 Hz Dimming ange: 100% to minimum ballast relative light output level (10% for Eco-10, 5% for Compact SE, 1% for Hi-lume) Switched Output ating: 16 A SoftswitchTM load Control Output ating: 500 ma for use with Lutron 3- wire ballasts or Lutron interface device Class 2 Sensor Power: 20 V, 50 ma max. Dimmable Load Types Lutron 3-wire phase controlled fluorescent dimming ballasts (Eco-10 and Hi-lume ) Environment Ambient Temperature Operating ange: 32-104 F (0-40 C) elative humidity: less than 90% non-condensing For indoor use only Module Wiring (see pages 4-6 for wiring diagrams) Terminal blocks accept wires of the following size: Bus (, ): #22 - #12 AWG (.64-2.5 mm 2 ) solid wire : #22 - #12 AWG (.64-2.5 mm 2 ) solid wire Wiring between module and ballasts is 4 conductors: Switched Hot Dimmed Hot Neutral Ground Wiring between module and ballast shall not exceed 500 ft. (150 m) Wiring between module and sensors shall not exceed manufacturers specifications. Dimmable Load Types equiring an Interface 16 A module can dim additional loads other than Hi-lume and Eco-10 ballasts when the appropriate Lutron FDI interface is used. NOTE: These load types are (120 V~ ONLY): Lutron Tu-Wire fluorescent dimming ballasts Incandescent (tungsten/halogen) Magnetic low-voltage transformer Neon/cold cathode
Dimensions Dimming Module 16A Module-3 09.27.07 B C Dimensions A = 7.8 in (200 mm) B = 5.0 in (130 mm) C = 2.5 in (65 mm) A Mounting Mount the Power Module onto a 4 x 4 in (102 x 102 mm) standard (1900) junction box (not included, but available; Lutron part number 241-496) Mount on a vertical or horizontal surface; all power wire connections will be made in the junction box; all bus wiring (Class 1 or 2) and sensor wiring (Class 2 only) connections will be made within the front cover of the unit. Mount in a location where the PW and indicators are visable. Electrical Contractors and Engineers All field installed Class 2 wiring must be separated from line voltage wiring by at least 0.25 in (6.4 mm) Some local electrical codes require Class 2 wiring to be separately routed in a metal conduit CEILING W A L L Junction box
Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Status Indicator () Solid: Circuit Level Pulse: No Indicateur de puissance (PW) On: l unité est alimentée Off: l unité n est pas alimentée ou est dysfonctionnelle Indicateur d activité () Plein: Niveau de circuit Impulsion: Aucune PW Indicador de Alimentación (PW) Encendido: unidad tiene corriente Apagado: unidad no tiene corriente o no está funcionando correctamente Indicador de estado () Dimming Module Power Module Line Voltage Wiring: 16A Module-4 09.27.07 Connect the input feed wires and the output load wires to the module as indicated in the wiring diagrams below Wiring between module and ballasts shall not exceed 500 ft. (150 m) ed Orange Power Module Wiring to Lutron 3-Wire Dimming Ballast: Distribution Panel (ground) (neutral) ed (switched hot) Orange (dimmed hot) Orange Fixture Ground Lutron 3-wire phase control dimming ballast Ground Neutral Hot +20V Orange Fixture Ground Lutron 3-wire phase control dimming ballast Colors indicate the module and ballast wire colors and/or ballast terminal colors
Bus Wiring Dimming Module 16A Module-5 09.27.07 Wire the bus to and terminals on the front of the module. When the bus is wired Class 1, the bus wiring must enter the left side knock out and maintain.25 in (6 mm) spacing from the Class 2 sensor wiring. When the bus is wired Class 2, the bus wiring may enter either knock out on the low voltage wiring area. Bus Details and wires are not polarity sensitive Bus length is limited by the wire gauge used for and as follows: Wire Gauge (solid wire) Bus Length (max) #12 AWG (2.05 mm) 2,200 ft (671 m) #14 AWG (1.63 mm) 1,400 ft (427 m) #16 AWG (1.29 mm) 900 ft (275 m) #18 AWG (1.02 mm) 570 ft (175 m) Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Indicateur de puissance (PW) Indicador de Alimentación (PW) On: l unité est alimentée Encendido: unidad tiene corriente Off: l unité n est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Indicateur de puissance (PW) Indicador de Alimentación (PW) On: l unité est alimentée Encendido: unidad tiene corriente Off: l unité n est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente Status Indicator () Indicateur d activité () Pulse: No Impulsion: Aucune Indicador de estado () Status Indicator () Indicateur d activité () Pulse: No Impulsion: Aucune Indicador de estado () PW PW Bus wiring knock out Class 2 wiring knock out - Purple - Purple/ To additional modules, ballasts, and the Bus supply NOTE: See page 2 for wiring specifications
Dimming Module Low Voltage Wiring 16A Module-6 09.27.07 Wiring to Wire color designations of the Class 2 Terminals: ed = 20 V = = (wallstation / receiver) Blue = Occupancy Sensor Yellow = Sensor Signal Wiring between module and sensors shall not exceed manufacturers specifications. Make sure that the supply breaker to the ballast module is OFF when wiring. Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW Class 2 wiring knock out Note - The module accepts only one Input. Use of the output from the Sensor precludes the use of an receiver or wallstation with the module. When both a daylight sensor and wallstation/ receiver are wired to the same module, the wire from the daylight sensor should not be connected. ed Blue Occupant Sensor Wired to Module Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW PW ed Yellow Sensor Wired to Module ed Yellow Sensor & Wallstation wired to the module ( wired only to keypad) NOTE: See page 2 for wiring specifications