How To Use A Lutron Power Supply



Similar documents
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

Switching Power Module

Phase-Adaptive Power Module

GRX-PWM Pulse Width Modulation Interface

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

RF Maestro Local Controls

Dual Technology Ceiling Mount Sensor

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

HomeWorks QS Processor

Color Mark Sensor with Red or Green LED E3S-VS

LED DIMMING A HELPFUL GUIDE...

Control Interfaces. GRAFIKR Systems a LUT-DMX

Reference Design. conference rooms

15 Series - Electronic step relay and dimmer. Features SERIE

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

SECTION LOW VOLTAGE LIGHTING CONTROLS

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Cross-beam scanning system to detect slim objects. 100 mm in

Design guide EcoSystem

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

12V Dimmable Driver EL-TMDRVR

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Remote Power Panels with Breakers

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

Lutron Linear Recessed and Video Conference Fixture Solutions

Radiant Temperature Sensor TY7321

HERZ-Thermal Actuators

Video Conference Indirect Wash LED Fixture

QSE-CI-DMX Control Interface

OMX-RS232 Control Interface

Quick Connect. quick - simple - efficient.

New Architectural Accessories

INSTALLATION INSTRUCTIONS

Product and functional description

EBDSPIR-PRM, EBDSPIR-PRM-IP

STRATO LED Drivers 70W, Single output

Lutron Linear Recessed and Video Conference Fixture Solutions

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

High Bay Occupancy Sensor Selection Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

QSE-CI-NWK-E Control Interface

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CalMod Design-Build Electrification Services

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

ADM1TE 5/30A DIN rail single phase two wire energy meter

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Electronic Control Devices The European Product Catalogue 2007

MechoNet TM Network Interface (MNI) Specification Submittal

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

EBDSPIR-DD, EBDSPIR-DD-IP

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

T7560A,B,C Digital Wall Module

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LIEBERT VNSA Installation Sheet

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

LIGHTING and LIGHTING SYSTEMS

Electronic Control Devices The European Product Catalogue 2007

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Exhibit C Design Review Guidelines

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

On/Off Relay Switch and 3-Way Switch Kit

2087 SERIES 120/277V LED

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

TROUBLESHOOTING LED DOWNLIGHTS

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

ACS-30-EU-EMDR-10-MOD

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

Digital input modules

SMART Board interactive flat panel with appliance Model 8055ie-SMP

How To Read A Pipe From A Sensor

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System

Linear Recessed Center Basket Fixture. Lutron

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

IPS HIGH-BAY / LOW-BAY LIGHTING

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Liquid Level Limit Switch liquiphant T FTL 20

Sensor Product Guide. Smart Sensing Control Solutions

Rosemount 333 HART Tri-Loop

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

How To Use A Flowmeter

Transcription:

Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts 16A Module-1 09.27.07 Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW +20V Lutron s Dimming Power Module allows integration of Lutron s 3-wire phase controlled dimming ballasts into Lutron s Bus (Eco-10TM and Hi-lumeTM series only). The Power Module combines digital commands and sensor data to determine the proper light level. Features Continuous, flicker-free dimming from 100% to minimum ballast level. (10% for Eco-10, 5% for Compact SE, 1% for Hi-lume) Provides 20 V power for and responds to one occupant sensor, one photo sensor, and one personal control input (infrared receiver or wallstation) Communicates status and sensor levels over the Bus Universal voltage input: 100-277 V 50/60 Hz Non-volatile (EEPOM) memory stores specific system information for 10 years from power down to power restored 100% performance tested at factory One-Line Bus To additional ballasts and modules (up to 64 total) Ballast eceiver 1 2 3 4 5 6 7 8 Bus Supply* Occupant Sensor Dimming Power Module Eco10TM or Hi-lumeTM Ballast* Ballast Ballast Sensor Lighting emote Keypad *Does not count as one of the ballasts or modules on the Bus.

Specifications Dimming Module 16A Module-2 09.27.07 Standards UL 916 Listed and CSA 184 Certified Meets ANSI C62.41 Category A surge protection standards up to and including 6 kv Manufacturing facilities employ ESD reduction practices that comply with the requirements of ANSI/ESD S20.20 Lutron Quality Systems registered to ISO 9001.2000 Power Operating Voltage: 100-277 V~ 50/60 Hz Dimming ange: 100% to minimum ballast relative light output level (10% for Eco-10, 5% for Compact SE, 1% for Hi-lume) Switched Output ating: 16 A SoftswitchTM load Control Output ating: 500 ma for use with Lutron 3- wire ballasts or Lutron interface device Class 2 Sensor Power: 20 V, 50 ma max. Dimmable Load Types Lutron 3-wire phase controlled fluorescent dimming ballasts (Eco-10 and Hi-lume ) Environment Ambient Temperature Operating ange: 32-104 F (0-40 C) elative humidity: less than 90% non-condensing For indoor use only Module Wiring (see pages 4-6 for wiring diagrams) Terminal blocks accept wires of the following size: Bus (, ): #22 - #12 AWG (.64-2.5 mm 2 ) solid wire : #22 - #12 AWG (.64-2.5 mm 2 ) solid wire Wiring between module and ballasts is 4 conductors: Switched Hot Dimmed Hot Neutral Ground Wiring between module and ballast shall not exceed 500 ft. (150 m) Wiring between module and sensors shall not exceed manufacturers specifications. Dimmable Load Types equiring an Interface 16 A module can dim additional loads other than Hi-lume and Eco-10 ballasts when the appropriate Lutron FDI interface is used. NOTE: These load types are (120 V~ ONLY): Lutron Tu-Wire fluorescent dimming ballasts Incandescent (tungsten/halogen) Magnetic low-voltage transformer Neon/cold cathode

Dimensions Dimming Module 16A Module-3 09.27.07 B C Dimensions A = 7.8 in (200 mm) B = 5.0 in (130 mm) C = 2.5 in (65 mm) A Mounting Mount the Power Module onto a 4 x 4 in (102 x 102 mm) standard (1900) junction box (not included, but available; Lutron part number 241-496) Mount on a vertical or horizontal surface; all power wire connections will be made in the junction box; all bus wiring (Class 1 or 2) and sensor wiring (Class 2 only) connections will be made within the front cover of the unit. Mount in a location where the PW and indicators are visable. Electrical Contractors and Engineers All field installed Class 2 wiring must be separated from line voltage wiring by at least 0.25 in (6.4 mm) Some local electrical codes require Class 2 wiring to be separately routed in a metal conduit CEILING W A L L Junction box

Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Status Indicator () Solid: Circuit Level Pulse: No Indicateur de puissance (PW) On: l unité est alimentée Off: l unité n est pas alimentée ou est dysfonctionnelle Indicateur d activité () Plein: Niveau de circuit Impulsion: Aucune PW Indicador de Alimentación (PW) Encendido: unidad tiene corriente Apagado: unidad no tiene corriente o no está funcionando correctamente Indicador de estado () Dimming Module Power Module Line Voltage Wiring: 16A Module-4 09.27.07 Connect the input feed wires and the output load wires to the module as indicated in the wiring diagrams below Wiring between module and ballasts shall not exceed 500 ft. (150 m) ed Orange Power Module Wiring to Lutron 3-Wire Dimming Ballast: Distribution Panel (ground) (neutral) ed (switched hot) Orange (dimmed hot) Orange Fixture Ground Lutron 3-wire phase control dimming ballast Ground Neutral Hot +20V Orange Fixture Ground Lutron 3-wire phase control dimming ballast Colors indicate the module and ballast wire colors and/or ballast terminal colors

Bus Wiring Dimming Module 16A Module-5 09.27.07 Wire the bus to and terminals on the front of the module. When the bus is wired Class 1, the bus wiring must enter the left side knock out and maintain.25 in (6 mm) spacing from the Class 2 sensor wiring. When the bus is wired Class 2, the bus wiring may enter either knock out on the low voltage wiring area. Bus Details and wires are not polarity sensitive Bus length is limited by the wire gauge used for and as follows: Wire Gauge (solid wire) Bus Length (max) #12 AWG (2.05 mm) 2,200 ft (671 m) #14 AWG (1.63 mm) 1,400 ft (427 m) #16 AWG (1.29 mm) 900 ft (275 m) #18 AWG (1.02 mm) 570 ft (175 m) Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Indicateur de puissance (PW) Indicador de Alimentación (PW) On: l unité est alimentée Encendido: unidad tiene corriente Off: l unité n est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente Power Indicator (PW) On: Unit is powered Off: Unit is not powered or is malfunctioning Indicateur de puissance (PW) Indicador de Alimentación (PW) On: l unité est alimentée Encendido: unidad tiene corriente Off: l unité n est pas alimentée Apagado: unidad no tiene corriente ou est dysfonctionnelle o no está funcionando correctamente Status Indicator () Indicateur d activité () Pulse: No Impulsion: Aucune Indicador de estado () Status Indicator () Indicateur d activité () Pulse: No Impulsion: Aucune Indicador de estado () PW PW Bus wiring knock out Class 2 wiring knock out - Purple - Purple/ To additional modules, ballasts, and the Bus supply NOTE: See page 2 for wiring specifications

Dimming Module Low Voltage Wiring 16A Module-6 09.27.07 Wiring to Wire color designations of the Class 2 Terminals: ed = 20 V = = (wallstation / receiver) Blue = Occupancy Sensor Yellow = Sensor Signal Wiring between module and sensors shall not exceed manufacturers specifications. Make sure that the supply breaker to the ballast module is OFF when wiring. Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW Class 2 wiring knock out Note - The module accepts only one Input. Use of the output from the Sensor precludes the use of an receiver or wallstation with the module. When both a daylight sensor and wallstation/ receiver are wired to the same module, the wire from the daylight sensor should not be connected. ed Blue Occupant Sensor Wired to Module Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur d activité () Indicador de estado () Pulse: No Impulsion: Aucune PW PW ed Yellow Sensor Wired to Module ed Yellow Sensor & Wallstation wired to the module ( wired only to keypad) NOTE: See page 2 for wiring specifications