RF Maestro Local Controls
|
|
|
- Rosanna Carpenter
- 9 years ago
- Views:
Transcription
1 RF Maestro Local Controls Wireless Series Local Controls RF Link-8.1 Designer-Style L o c a l c o n t r o l s RF Maestro local controls function much like standard dimmers and switches, but can be controlled as part of the whole-house lighting control system. Local lighting controls are useful in locations where single circuits of lighting need to be dimmed or switched. Local fan-speed controls are useful in locations where control of a single ceiling paddle fan is needed. RF Maestro dimmers incorporate advanced features such as fade-on / fade-off, long fade-off, and rapid full-on. In addition, the local controls may be programmed similar to a keypad button press with single and double tap functions, turning multiple lights on or off. RF Maestro local controls include a Front Accessible Service Switch (FASSTM) for safe lamp replacement. HomeWorks RF Maestro local controls install in single-pole, 3-way, or 4-way applications. A c c e s s o r y c o n t r o l Remote dimmers (HD-RD) and remote switches (HD-RS) are used in conjunction with a RF Maestro local control to provide 3-way and 4-way control. Use up to nine HD-RD with a single RF Maestro dimmer / fan-speed control for dimming / speed control from up to ten locations. Use up to nine HD-RS with a single RF Maestro switch for switching from up to ten locations. See pg. 77. F i n i s h e s a n d C o l o r s Maestro local controls are available in designer gloss and Satin Colors matte finishes. See Appendix F: Colors & Finishes. g a n g i n g M A E S T R O C o n t r o l s Install multiple Maestro controls together (mounted sideby-side behind a single faceplate) in a multi-gang wallbox for a cleaner look. The load rating for each control must be derated when ganging with other controls. For ganging and derating information, see Table 1 pg. 76. I n s t a l l a t i o n N o t e Use inch (89 mm) deep wallboxes for ease of installation. d i m m i n g c o n t r o l l o a d r a t i n g s HRD-6D and HRD-6ND dim a single incandescent or magnetic low-voltage circuit up to 600 W / VA from one location. HRD-6ND requires a neutral wire connection. HRD-10D and HRD-10ND dim a single incandescent or magnetic low-voltage circuit up to 1000 W / VA from one location. HRD-10ND requires a neutral wire connection. HRD-5NE dims a single incandescent or electronic low-voltage circuit up to 500 W from one location. HWD-5NE requires a neutral wire connection. Fa n - S p e e d c o n t r o l L o a d r a t i n g s HRD-2ANF controls a single ceiling fan up to 2 A from one location. HRD-2ANF requires a neutral wire connection. s w i t c h i n g c o n t r o l L o a d r a t i n g s HRD-8ANS switches a single circuit of any lighting load type up to 8 A (or a motor load up to 5.8 A [1/4 HP]) from one location. HRD-8ANS requires a neutral wire connection. Note: For wattages exceeding those listed above or for load types other than those listed, a neutral wire dimmer (HRD-6ND) and a power booster or interface is required. See pg. 107 for more information. C O M M U N I C A T I O N T O P R O C E S S O R All RF Maestro local lighting controls must be located within 30 feet (9 m) of an RF processor or a hybrid RF / wired repeater. Each HomeWorks RF-capable processor can control up to 64 RF local controls. 70 Technical Support 24 Hours a Day/7 Days a Week
2 All HomeWorks RF Maestro Local Controls Model Numbers Input Voltage Regulatory Approvals Environment Cooling Method Air Gap Addressing ESD Protection Surge Protection Fail-Safe Operation Dimensions Mounting Ganging Auxiliary Controls Shipping Weight HRD-6D: 600 W / VA Incandescent/MLV Dimming Control. HRD-6ND: 600 W / VA Incandescent/MLV Dimming Control with Neutral Wire. HRD-10D: 1000 W / VA Incandescent/MLV Dimming Control. HRD-10ND: 1000 W / VA Incandescent/MLV Dimming Control with Neutral Wire. HRD-5NE: 500 W ELV Dimming Control with Neutral Wire. HRD-2ANF: 2 A Fan Speed Control with Neutral Wire. HRD-8ANS: 8 A Switching Control with Neutral Wire. HD-RD: Accessory Control/Remote. HD-RS: Accessory Control/Remote Switch. 120 V 50 / 60 Hz UL, CSA, NOM, FCC, IC Ambient operating temperature: 0 C to 40 C, 32 F to 104 F Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Passive cooling. FASSTM (Front Accessible Service Switch). See Fig. 2, pg. 75. Via the HomeWorks software, using unique device serial numbers. Units must be installed prior to addressing. Counts as 1 of the 64 dimmer addresses on the RF dimmer link. Meets or exceeds the IEC standard. Meets or exceeds ANSI / IEEE standard c In the unlikely event that communication with the processor is interrupted, all Maestro local controls will still operate, offering local control. See Fig. 1, pg. 75. Controls mount in standard US wallboxes. For easier installation, Lutron recommends using (89 mm) deep wallboxes. If mounting one control above another, leave at least (11.4 cm) vertical spacing between them. Unit must be placed within 30 feet (9 m) of a hybrid RF / wired repeater or an RF processor. When ganging RF Maestro local controls, it is necessary to derate the control. See Table 1, pg. 76 for specific derating information. Use only Maestro remote dimmers or switches (HD-RD or HD-RS); mechanical 3- or 4-way switches will not work. Up to nine Maestro remote dimmers or switches may be used with one Maestro local dimming / fan speed or switching control. See pg lb. (0.3 kg) Technical Support: [email protected] 71
3 HRD-6D 600 W Incandescent / MLV Dimming Control HRD-6ND 600 W Incandescent / MLV Dimming Control with Neutral Wire HRD-10D 1000 W Incandescent / MLV Dimming Control Incandescent, magnetic low-voltage 2,3, and tungsten halogen. single-gang: 600 W / VA end gang: 500 W / VA middle gang: 400 W / VA 50 W / VA See Figs. 5, 7, pg. 77. Standard single-pole, 3-way, and 4-way wiring. Incandescent, magnetic low-voltage 2,3, tungsten halogen, electronic low-voltage 3 (using ELVI-1000 Interface), and Lutron Hi-Lume and ECO-10 Fluorescent Dimming Ballasts (using GRX-FDBI-16A-120 or Hi-Power 2 4 6TM) 4,5. Output is compatible with Lutron NGRX-PB-WH and Hi-Power Power Boosters for applications up to 30,000 W. single-gang: 600 W / VA end gang: 500 W / VA middle gang: 400 W / VA 10 W / VA See Figs. 6, 8, pg. 77. Single-pole, 3-way, and 4-way wiring. Requires a neutral wire connection in the wallbox. Incandescent, magnetic low-voltage 2,3, and tungsten halogen. single-gang: 1000 W / VA end gang: 800 W / VA middle gang: 650 W / VA 50 W / VA See Figs. 5, 7, pg. 77. Standard single-pole, 3-way, and 4-way wiring. 72 Technical Support 24 Hours a Day/7 Days a Week
4 HRD-10ND 1000 W Incandescent / MLV Dimming Control with Neutral Wire Incandescent, magnetic low-voltage 2,3, tungsten halogen, electronic low-voltage 3 (using ELVI-1000 Interface), and Lutron Hi-Lume and ECO-10 Fluorescent Dimming Ballasts (using GRX-FDBI-16A-120 or Hi-Power 2 4 6TM) 4,5. Output is compatible with Lutron NGRX-PB-WH and Hi-Power Power Boosters for applications up to 30,000 W. See pg single-gang: 1000 W / VA end gang: 800 W / VA middle gang: 650 W / VA 10 W / VA See Figs. 6, 8, pg. 77. Single-pole, 3-way, and 4-way wiring. Requires a neutral wire connection in the wallbox. HRD-2ANF 2 A Fan Speed Control with Neutral Wire Single ceiling paddle fan. single-gang: 2 A end gang: 2 A middle gang: 2 A A See Figs. 6, 8, pg. 77. Single-pole, 3-way, and 4-way wiring. Requires a neutral wire connection in the wallbox. HRD-5NE 500 W ELV Dimming Control with Neutral Wire Load Types Incandescent and electronic low-voltage. single-gang: 500 W end gang: 450 W middle gang: 400 W 40 W See Figs. 6, 8, pg. 77. Single-pole, 3-way, and 4-way wiring. Requires a neutral wire connection in the wallbox. HRD-8ANS 8 A Switching Control with Neutral Wire Incandescent, magnetic low-voltage 2, electronic low-voltage, fluorescent 5, and motors. single-gang: lighting 8 A motor 5.8 A (1/4 HP) end gang: lighting 6.5 A motor 5.8 A middle gang: lighting 5 A motor 5 A lighting 10 W / VA motor A See Figs. 6, 8, pg. 77. Requires a neutral wire connection in the wallbox. Technical Support: [email protected] 73
5 HD-RD 3- or 4-way Remote Compatible Controls HD-RS 3- or 4-way Remote Switch Compatible Controls (1) To reduce the risk of overheating and possibly damaging other equipment, do not install HRD-6D, HRD-6ND, HRD-10D, or HRD-10ND to control receptacles, motor-operated appliances, fluorescent lighting, or electronic low-voltage transformer loads. Do not install HRD-8ANS to control receptacles. Do not install HRD-2ANF to control receptacles, motor-operated appliances (non-ceiling fan),or any type of lighting load. (2) Because low-voltage transformers vary widely in efficiency, the input VA of each transformer should be measured directly. If this is not possible, use the maximum lamp wattage figures for the transformer, which have a built-in safety margin. (3) For low-voltage applications using the HRD-6D, HRD-6ND, HRD-10D or HRD-10ND, use with core and coil (magnetic) lowvoltage transformers only. Do not use any solid-state electronic low-voltage transformers. Operation of a low-voltage circuit with all lamps inoperative or removed may result in current flow in excess of normal levels. To avoid transformer overheating and premature transformer failure, Lutron strongly recommends the following: a) Do not operate low-voltage circuits without operative lamps in place. b) Replace burned-out lamps as soon as possible. c) Use transformers that incorporate thermal protection or fuse transformer primary windings to prevent transformer failure due to overcurrent. HRD-6D, HRD-6ND, HRD-10D, HRD-5NE, HRD-2ANF and HRD-10ND. See local control. See local control. See Figs. 7, 8, pg. 77. Standard single-pole, 3-way, and 4-way wiring. HRD-8ANS See local control. See local control. See Fig. 8, pg. 77. Standard single-pole, 3-way, and 4-way wiring. (4) For proper dimming performance, fluorescent lamps must be operated at full intensity for 100 hours prior to dimming. (5) To determine the maximum load, add the line currents listed on each ballast connected to this control. The total line current can not exceed the maximum load capacity rating of the control. Warning: Do not exceed a maximum of 20 ballasts per control. (6) Fan Speed Control: Use to control a single paddle-type ceiling fan that has a permanent split-capacitor motor. Do not use to control shaded-pole type motors (i.e. exhaust fans) or lighting. 74 Technical Support 24 Hours a Day/7 Days a Week
6 A B Wallbox C A B C D E Inches mm Figure 1 Dimensions D HRD-5NE only C Control ( shown) E Control Mounting Screws HRD-5NE only Wallplate Adapter Power ON Figure 3 Mounting and Parts Identification Power ON Figure 2 FASSTM (Front-Accessible Service Switch) Adapter Mounting Screws Wallplate Wallplate / Adapter purchased separately. Power OFF Power OFF Technical Support: [email protected] 75
7 RF Maestro Local Controls (cont.) Single Gang -8ANS Only: -8ANS controls have fins that need to be removed for multigang installations. Table 1 Minimum and Ratings Single Gang Control Load Type All Cases Single-Gang End of Gang Middle of Gang HRD-6D HRD-6ND HRD-10D HRD-10ND Incandescent 50 W / VA 600 W 500 W 400 W Magnetic Low Voltage 50 W / VA 450 W / 600 VA 400 W / 500 VA 300 W / 400 VA Incandescent 10 W / VA 600 W 500 W 400 W Magnetic Low Voltage 10 W / VA 450 W / 600 VA 400 W / 500 VA 300 W / 400 VA Incandescent 50 W / VA 1000 W 800 W 650 W Magnetic Low Voltage 50 W / VA 800 W / 1000 VA 600 W / 800 VA 500 W / 650 VA Incandescent 10 W / VA 1000 W 800 W 650 W Magnetic Low Voltage 10 W / VA 800 W / 1000 VA 600 W / 800 VA 500 W / 650 VA HRD-5NE Electronic Low Voltage 40 W 500 W 450 W 400 W HRD-8ANS Lighting 10 W / VA 8 A 6.5 A 5 A Motor A 5.8 A (1/4 HP) 5.8 A 5 A HRD-2ANF Ceiling Fan A 2 A 2 A 2 A HD-RD N/A* N/A* N/A* N/A* N/A* HD-RS N/A* N/A* N/A* N/A* N/A* * See local control Removing Fins Each control has inside fins removed MIDDLE of Gang Figure 4 Ganging Configuration and Derating Information END of Gang Do Not remove outside fins on End of Gang Controls Middle of Gang Control has all fins removed 76 Technical Support 24 Hours a Day/7 Days a Week
8 * Hot 120 V 50 / 60 Hz Neutral * Figure 5 HRD-6D and HRD-10D Single-Location Wiring Diagram Lighting Load Hot 120 V 50 / 60 Hz Neutral or Switch * Load Figure 6 HRD-2ANF, HRD-6ND, HRD-10ND, HRD-5NE, and HRD-8ANS Single-Location with Neutral Wiring Diagram When using controls in single-location installations, tighten the control s blue terminal (-5NE: cap off blue wire). DO NOT connect the blue terminal (-5NE: blue wire) to any other wiring or to ground. 1 Up to nine HomeWorks Maestro Remote s or Switches may be connected to the HomeWorks RF Maestro or Switch. Total length of wire used to connect blue terminals (-5NE: blue wire) may be up to 250 feet (76 m). 2 Hot 120 V 50 / 60 Hz Neutral Hot 120 V 50 / 60 Hz Neutral Remote Remote or Switch Neutral wire s / Fan Speed Controls / Switches must be connected on the lighting load side of a multi-location installation. Silver Remote Figure 7 HRD-6D and HRD-10D Multi-Location Installation 1 Remote or Switch White White Lighting Load Figure 8 HRD-2ANF, HRD-6ND, HRD-10ND, HRD-5NE, and HRD-8ANS Multi-Location Installation with Neutral 1, 2 Silver / Fan Speed / Switch Terminal Color Wire Color (-5NE) Yellow Silver White Terminal Color Wire Color (-5NE) Yellow Silver White Load Technical Support: [email protected] 77
9 RF Lamp Wireless Series Local Lighting Controls RF Link-8.1 Tabletop R F L A M P D I M M E R ( M O D E L # H R T - 3 L D - X X ) HomeWorks RF lamp dimmers allow table and floor lamps to be included in the HomeWorks lighting control system. Each RF lamp dimmer controls one table or floor lamp with simple and intuitive buttons for on / off and raise / lower. Simple to install, RF lamp dimmers are plugged into any standard wall outlet. Built-in intelligence allows each RF lamp dimmer to be controlled from the HomeWorks keypad in the home, as well as from touchscreens, universal remotes, and home automation controls. RF lamp dimmers incorporate advanced features such as fade-on / fade-off, long fade-to-off, and rapid full-on. In addition, the local control may be programmed similar to a keypad button press with single and double tap functions, turning multiple lights on or off. RF lamp dimmers may be used in any system design with RF capability. F I N I S H E S A N D C O L O R S RF lamp dimmers are available in Snow (SW) and Midnight (MN). D I M M I N G C O N T R O L L O A D R A T I N G S HRT-3LD dims a single incandescent or magnetic lowvoltage circuit up to 300 W / VA. C O M M U N I C A T I O N T O P R O C E S S O R The RF lamp dimmers must be located within 30 feet (9 m) of an RF processor or a hybrid repeater. Each HomeWorks processor can control up to 64 RF local controls. RF Lamp (HRT-3LD) 78 Technical Support 24 Hours a Day/7 Days a Week
10 RF Lamp (cont.) Model Number Input Voltage Regulatory Approvals Load Types Environment Addressing Diagnostics ESD Protection Surge Protection Fail-Safe Operation Dimensions Shipping Weight in (119 mm) in (75 mm) HRT-3LD: Lamp dimming control. 120 V 50 / 60 Hz UL, CSA, NOM, FCC, IC Incandescent, magnetic low-voltage 1,2, tungsten halogen. 300 W / VA 10 W / VA Ambient operating temperature: 0 C to 40 C, 32 F to 104 F Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Via the HomeWorks software, using unique device serial numbers. Units must be installed prior to addressing. Counts as 1 of the 64 dimmer addresses on the RF link. LEDs provide diagnostics for troubleshooting. Meets or exceeds the IEC standard. Meets or exceeds ANSI / IEEE standard c In the unlikely event that communication with the processor is interrupted, all Maestro local controls will still operate, offering local control in (75 mm) x in (119 mm) x in (24 mm) See Fig. 1 below lbs. (0.34 kg) Figure 1 Dimensions Cord Length: 6 ft. (1.8 m) in (23.9 mm) in (17.5 mm) Plug lamp cord into back of RF Lamp dimmer plug. Plug RF lamp dimmer plug into any standard wall outlet. Figure 2 Installation (1) Because low-voltage transformers vary widely in efficiency, the input VA of each transformer should be measured directly. If this is not possible, use the maximum lamp wattage figures, which have a built-in safety margin. (2) For low-voltage applications using the HRT-3LD use with core and coil (magnetic) low-voltage transformers only. Do not use any solid-state electronic low-voltage transformers. Operation of a low-voltage circuit with all lamps inoperative or removed may result in current flow in excess of normal levels. To avoid transformer overheating and premature transformer failure, Lutron strongly recommends the following: a) Do not operate low-voltage circuits without operative lamps in place. b) Replace burned-out lamps as soon as possible. c) Use transformers that incorporate thermal protection or fuse transformer primary windings to prevent transformer failure due to overcurrent. Technical Support: [email protected] 79
Switching Power Module
369357e 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic
Phase-Adaptive Power Module
369356c 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic
Maestro Wireless Dimmers and Switches
Maestro Wireless s and es The Maestro WirelessR solution incpates Maestro WirelessR load controls, wireless senss, and wireless remote controls, which provides a system that delivers energy savings, convenience,
Controls SPECIFICATION SUBMITTAL. www.lutron.com/maestro MAESTRO CONTROLS. The High-Tech Multi-Location Dimmer
SPECIFICATION SUBMITTAL The High-Tech Multi-Location Dimmer Controls Dimmer MAESTRO CONTROLS Dimmers s One tap on to selected light level/off; two taps full bright; press & hold for 10-second fade off
Preset Scene Dimmer with Infrared Remote Control
Preset Scene Dimmer with Infrared Remote Control Product Features Simple to use Recalls preset lighting scenes by wall-mounted master control or infrared remote control Simultaneously controls all dimmers
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron EcoSystem dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron EcoSystem bus
Home Dimming System. Product Family Features. Specification Features. Integration. Color Palette (For latest color information, visit www.lutron.
Home Dimming System Product Family Features Easy-to-install retrofit lighting control system No new wiring needed for installation Lutron s innovative radio frequency communication technology provides
How To Use A Lutron Power Supply
Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts 16A Module-1 09.27.07 Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur
Dimmer and Bulb Compatibility
Dimmers Buying Guide By reducing the amount of energy provided to the lighting fixtures they control, dimmers are an easy and effective way to save energy and extend the life of the bulb. They also offer
Remote Power Panels with Breakers
Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,
HomeWorks QS Processor
product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication
New Architectural Accessories
New Architectural Accessories 369921c 1 02.01.16 New Architectural accessories provide a clean, consistent aesthetic by allowing accessories to be added to the PalladiomTM and GRAFIK TTM product lines.
SPECIFICATION SUBMITTAL
SPECIFICATION SUBMITTAL Controls The elegant thin-profile TapSwitchTM dimmer. Select light level with slider www.lutron.com/vareo CONTROLS AND ACCESSORIES Preset Dimmers Electronic Tapswitches Tap on to
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
Maestro dimmers, sensors, timers and fan controls
Designer wallplate opening Maestro dimmers, sensors, timers and fan controls 2.94 in (75 mm) Shown actual size: Maestro dimmer and 1-gang Claro wallplate in White (WH). 4.69 in (119 mm).30 in (7.6 mm)
HomeWorks QS Wired seetouch Designer Keypads
HomeWorks QS seetouch keypads provide homeowners with a simple and elegant way to operate lights, shades / draperies, motorized screens, thermostats, and many other devices. HomeWorks QS seetouch keypads
Temperature Control from Lutron
TouchPRO Wireless thermostat seetemp wall control in White Temperature Control from Lutron Home Control+ app Use Lutron s Home Control+ app to manage your home s temperature while at home or while you
GRX-PWM Pulse Width Modulation Interface
Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched
HomeWorks Technical Reference Guide Rev F
HomeWorks Technical Reference Guide Rev F Table of Contents Introduction Introduction to HomeWorks.................. 4 Features Overview......................... 6 Specifying a HomeWorks System................
Maestro collection. dimmers and accessories. Distributed by. convenience, style, and comfort for every room in your home
Distributed by Maestro collection dimmers and accessories convenience, style, and comfort for every room in your home dim the lights 10% 25% 50% 75% saves electricity 10% 20% 40% 60% extends incandescent
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels
369344c 04.28.204 LP dimming panels are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Works directly with incandescent, magnetic low
HomeWorks QS Wired Signature SeriesTM Keypads
HomeWorksR QS Wired Signature SeriesT keypads provide homeowners with a simple and elegant way to operate lights, shades/draperies, motorized screens, thermostats,and many other devices. HomeWorksR QS
Wallbox Lighting Controls Guide
Wallbox Lighting Controls Guide save energy with LutronTM innovative lighting controls for homes and commercial spaces of every type and style. world-class quality Lutron quality is fuelled by a relentless
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily
EKOS Cart. Instructions for Use
EKOS Cart Instructions for Use EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) [email protected] (e-mail) - 1-4913-002 REV E Intended Use
PUCK LED 3W, 12V AC/DC REV.04.20.12
PUCK LED 3W, 12V AC/DC Remove Collar for Recessed Mounting Surface Mount - White Surface Mount - Satin Aluminum Surface Mount (Collar Included) Recessed.50" (1.27cm).50" (1.27cm) 2.42" (6.15cm) Recessed
ColorDial Pro Easily configure and control LED light shows
Easily configure and control LED light shows Easily configure and control LED light shows is an Ethernet-based, stand-alone lighting controller and interface for intelligent RGB and intelligent white (iw)
QuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
12V Dimmable Driver EL-TMDRVR
Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed
Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers
PUCK LED 3W, 12V AC/DC REV05.12.16
PUCK LED 3W, 12V AC/DC Remove Collar for Recessed Mounting Surface Mount - Satin Aluminum Surface Mount (Collar Included) Recessed Surface Mount - Description: Recessed or surface-mount, Puck LED features
GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS- - - - - - SpaceBuild Specification Worksheet. Touch Screens
SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for medium-sized spaces that require additional options such as expansion modules for more load types, touch screens,
Sensor Product Guide. Smart Sensing Control Solutions
Sensor Product Guide Smart Sensing Control Solutions Service and Support During Every Step of the Process. Only Leviton has the service and support to help you create a lighting control system that does
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
DOT LED 1W, 12V AC/DC
W-30D DOT LED 1W, 12V AC/DC.73" 85cm) DOT-RD-1W-30D W-90D 0.9" 2.3cm) 0.73" (1.85cm) DOT-RD-1W-30D-30K-SA DOT-RD-1W-30D 0 URFACE DOT-RD-1W-90D.73" (1.85cm) 0.73" (1.85cm).9" (2.3cm).75" (1.9cm).84" (2.1cm)
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch
2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Lutron architectural accessories & wallplates
& wallplates 2.75 (70mm) available colors (see page 14 for color swatches) colors (matte finish) WH BE IV AL LA white beige ivory almond light almond GR TP BR BL SI gray taupe brown black sienna 4.56 (116mm)
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Control Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX
369-564a 1 10.25.11 DMX 512 Control Interface Description Allows GRAFIK EyeR lighting controls to operate lighting and other equipment that uses the DMX 512 protocol, including: - Strobes, fiber optic
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
Wireless Lighting Control. On/Off/Dim. Dimmer Switch. www.lowes.com/iris
45639 Wireless Lighting Control On/Off/Dim Dimmer Switch marthome www.lowes.com/iris Introduction: Thank you for your purchase of a GE Z-Wave control device. Z-Wave technology is designed to automate
SO-4SN- - SO-4SI- - 4-Button Wallstation with Off and Raise/Lower
LUTON olor and Engraving odes SO-SN- - SO-SI- - -utton Wallstation with Off and aise/lower Off SO-SN-WH-EGN (Non-insert version) LEDs Scene Selection uttons Engraving Off Master aise/lower so-s 5..06 Description
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview
Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching capabilities? The HP Managed Power Distribution Unit
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER
INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER 300W 600W 900W 1200W ATTENTION: Please read and understand thoroughly this installation guide to ensure safe and efficient operation of this Power Module 1 Open
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor
On/Off Relay Switch and 3-Way Switch Kit
45637/45638 Wireless Lighting Control On/Off Relay Switch and 3-Way Switch Kit marthome Control the On/Off status of permanently installed lighting, fans and more! www.lowes.com/iris 2012 JASCO Made in
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
package contents accessories (5) wall dimmers (5) designer inserts (white, ivory, almond, or light almond)
package contents (5) wall dimmers (5) designer inserts (white, ivory, almond, or light almond) (1) master control Create a safe path of light into and throughout your home with AuroRa wireless lighting
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Architectural Lighting Control System
Architectural Lighting Control System Environ3 architectural lighting control system is a revolutionary networked system of line voltage master keypads, wallbox dimmers, and infrared remotes that provide
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS. Exclusively by:
AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS Exclusively by: DOORS AT THE PUSH OF A BUTTON Welcome Home The Franklin Autoswing is a sophisticated door opener system for outswing carriage
HP 2530 8-Port Switches Quick Setup Guide
HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to
NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS
NSI DIGITAL DIMMING SYSTEM NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS Software Revision 1.41, Version C UL, Mfg Q3/96, and above SPECIFICATIONS Number of Channels: 9800 : 8 channels Output capacity:
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
DVI DA2 and DVI DA 4 User Guide
DVI DA2 and DVI DA 4 User Guide This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Amplifiers. Unless stated otherwise, distribution amplifier or the unit
HomeWorks QS. Save energy with unparalleled total home control
HomeWorks QS Save energy with unparalleled total home control HomeWorks QS HomeWorks has been the leader in light control for exclusive homes for over a decade. And now, we ve taken that light control
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
HotSwap MBP Maintenance Bypass
ENGLISH HotSwap MBP Maintenance Bypass MBP6Ki MBP11Ki MBP11Ki1 Installation and user manual Copyright 201 EATON All rights reserved. Service and support: Call your local service representative SAFETY INSTRUCTIONS
BITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface
Advanced Power over Ethernet Controllers Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER Gigabit PoE Ports Intuitive Configuration Interface Advanced Switch Management Features Advanced Gigabit PoE Managed Switch
Cisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS
MOTION SENSOR PIR LIGHT SWITCH Cat No. ZV810 INSTALLATION & OPERATING INSTRUCTIONS ZV810 Motion Sensor PIR Light Switch Please read the instructions before using the product and retain for future use.
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
Y7230A CO 2 Alarm System
Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
HP 2530 24-Port and 48-Port Switches Quick Setup Guide
HP 2530 24-Port and 48-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Light Source User Guide
Light Source User Guide Compact DMX Light Source Models covered by this manual: UFO 150 CDMXG Glass, DMX - 240V UFO 150 CDMXP Plastic, DMX - 240V Universal Fibre Optics Issue 2 Revised: 23092013 Universal
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Powerline 1200 User Manual
User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product.you can visit www.netgear.com/support to register
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.