Sustainable Performance for Data Centres DCEM-Plus Energy Management and more!
our understanding of the challenges of Data Centers Energy Efficiency and Green IT Creating sustainable performance by reducing the consumption of energy and other resources, greenhouse gas (GHG) emissions, and Power Usage Effectiveness (PUE). cloud computing mobility Cost Effectiveness Finding partners who can build your competitive advantage by optimizing energy consumption and lowering Total Cost of Ownership (TCO). Saas Capacity to Evolve Maintaining the agility and skills needed to react to dynamic customer energy demand, and to deliver operational performance metrics and Service Level Agreements (SLAs) profitably. internet Why DCEM-Plus? video Reliability and Availability Providing continuity of service of energy systems in order to guarantee 7x24 uptime and availability of data. iaas Why Dalkia? Dalkia is a leading operator and developer of energy-and-resource-efficient solutions. With 49,800 personnel operating nearly 133,000 installations in 35 countries, we are positioned to apply optimal methods and procedures to the management of electrical, thermal, and other infrastructure assets. Our customers benefit from access to our best practices for energy and resource management, which we develop globally and practice locally. We do not manufacture and sell equipment. Therefore, we are able to implement objective, technology-neutral and brand-neutral solutions that are always in the best interest of our customers. We provide technical, operational, and related energy services to data centers with millions of square feet of white space in the USA, Europe, Asia and Australia. We recognize many of the unique challenges and risks which data centers must manage related to energy, availability and resource efficiency. With this in mind, we have developed our Data Center Energy Management Plus (DCEM-Plus) suite with three customizable solutions to optimize the following: Operations & Maintenance Resource Efficiency 7x24 Energy Availability Total Cost of Ownership Environmental Sustainability Risk Management DCEM-Plus Solutions Reliability Solution ReliabilitY + ENERGY Solution ReliabilitY + ENERGY + EFFICIENCY Solution Performance guarantees related to energy availability and efficiency, as applicable to the solution implemented.
Comparison of Dalkia s Suite of Data Center Energy Management Solutions key elements reliability reliability + energy reliability + energy + efficiency Operations & Maintenance Installation & Commissioning Control & Optimization of Energy Cost Energy Efficiency Assessment (audit, recommendations, certification management e.g., LEED & Energy Star) Optional Energy Monitoring (metering, real-time data reporting, and dashboard) Optional Energy Design Strategy Consulting and Deployment of Optimized Solutions Energy Savings Measures with Commitment Management of Energy System Scalability and Space Planning Optional Optional Optional Engineering Services (thermographic scanning, arc flash and electrical coordination studies, etc.) Optional Optional guarantees Availability and Operational Performance Guarantee Energy Savings Guarantee Total Data Center Efficiency Guarantee Our answer: Sustainable Performance Dalkia has made Sustainable Development the core of its business model. It is a priority for the creation of significant value in response to the challenges of the sustainable development of Data Centres. In addition to the ISO 9001/14001/ OHSAS 18001 certifications, Dalkia was 2012 verified according to the Sustainability standard AFAQ 26000. Economic Development To guarantee the continuity of your Business activity and ensure a long life for your investments. Environmental Development To reduce the footprint of your Data Centres. Social Development To grant access to the information for all your users. Environment Economy Equitable Sustainable Livable Viable Society
Reliability Services With the DCEM-Plus Reliability Solution, existing and new data centers can rely on Dalkia to guarantee the continuity of their operations. Methods Team Engineering for Maintenance and Operations Operating team Guarantee of High availability of facilities 24/7 maintenance team Long-lasting optimization of facilities INDUSTRIAL UTILITIES: Facilities Chilled water Fire detection Fire extinguishing Compressed air Heat production Lighting (normal, safety, external) Air conditioning HV electricity A HV electricity B Electricity generating units Ventilation, Smoke removal INDUSTRIAL UTILITIES: Connections Logistical supervision and connecting of bays Space planning management of computing rooms MULTI-TECHNICAL: Building Raised floors CCTV Anti-intrusion Access Control Interphones, Videophones Wastewater Lightning protection systems (CEM) CTM Acoustic processing Industrial doors Lifting tables Lifting devices (hoists) Outside water networks, Plumbing Storm water basin, Roads, Utilities, fences
ReliabilitY & ENERGY Services With the DCEM-Plus ReliabilitY + ENERGY Solution, existing and new data centers can partner with Dalkia to optimize their operating conditions + energy costs. This solution is designed to optimize the Power Usage Effectiveness (PUE) and Carbon Usage Effectiveness (CUE) of data centers. server rack room technical building city Methods Team Engineering for Maintenance and Operations Operating team Guarantee of High availability of facilities 24/7 maintenance team Long-lasting optimization of facilities INDUSTRIAL UTILITIES: Facilities Chilled water Fire detection Fire extinguishing Compressed air Heat production Lighting (normal, safety, external) Air conditioning HV electricity A HV electricity B Electricity generating units Ventilation, Smoke removal INDUSTRIAL UTILITIES: Connections Logistical supervision and connecting of bays Space planning management of computing rooms MULTI-TECHNICAL: Building Raised floors CCTV Anti-intrusion Access Control Interphones, Videophones Wastewater Lightning protection systems (CEM) CTM Acoustic processing Industrial doors Lifting tables Lifting devices (hoists) Outside water networks, Plumbing Storm water basin, Roads, Utilities, fences OPERATOR IN PARTNERSHIP DALKIA Virtualization Direct Cooling Space Planning Auto-switch Management Distribution Production Balancing Operations Maintenance Free-Cooling Fire safety Design Insulation Internia Safety Supervison Heating network (recovery of unavoidable heat) Cold network Management and Optimization of Energy Costs: PUE actions
ReliabilitY, ENERGY, EFFICIENCY Services design WORKS OPERATIONS CONSULTING AND ENGINEERING IN DESIGN PHASE Project Management Uninterruptible Power Supply High efficient cooling systems Renewable & Recovery Energy (wasted heat recovery, free-cooling, etc) WORKS PHASE Commissioning Site Acceptance Tests Operation processes Organization With the DCEM-Plus R EliabilitY + ENERGY Solution, existing and Procedures & Methods new data centers can partner with Veolia Energy to optimize their operating conditions + energy costs. This solution is designed to optimize the Power Usage implementation Effectiveness (PUE) and Carbon Usage Effectiveness (CUE) of data centers. Building Energy Efficiency Financing and contractual performance server rack room technical building city Methods Team Engineering for Maintenance and Operations OPERatiNG team Guarantee of High availability of facilities 24/7 MaiNtENaNCE team Long-lasting optimisation of facilities INDUStRial UtilitiES: Facilities Chilled water Fire detection Fire extinguishing Compressed air Heat production Lighting (normal, safety, external) Air conditioning HV electricity A HV electricity B Electricity generating units Ventilation, Smoke removal i NDUStRial UtilitiES: Connections Logistical supervision and connecting of bays Space planning management of computing rooms MUlti-tECHN ical: Building Raised floors Industrial doors CCTV Lifting tables Anti-intrusion Access Control Lifting devices (hoists) Interphones, Videophones Outside water networks, Wastewater Plumbing Lightning protection systems (CEM) Storm water basin, Roads, CTM Utilities, fences Acoustic processing OPERatOR i N PaRtNERSHi P DalKia Virtualization Direct Cooling Space Planning Auto-switch Management Distribution Production Balancing Operations Maintenance Free-Cooling Fire safety Design Insulation Internia Safety Supervison Heating network (recovery of unavoidable heat) Cold network Management and Optimization of Energy Costs: PUE actions
A GLOBAL EXPERTISE Present in more than 35 countries, Dalkia has acquired international experience in Performance Optimization for Data Centres, all of our customers worldwide benefit from the expertise of the local teams and of our network of experts and operators. FRANCE EDF (Val-de-Reuil) FRANCE Telehouse (Paris) 3 sites FRANCE SFR (10 sites across the southern half of France) BELGIUM Colt AUSTRALIA Polaris (Springfield) SOME NUMBERS Nearly 180,000 m² of IT surface area is managed by Dalkia today throughout the world PORTUGAL Portugal Telecom INDIA IBM They trust us
Some references Global Data Center Clients Dalkia has implemented DCEM solutions at data centers around the world. Our customers benefit from the combined expertise of our local teams and our worldwide network of experts and operators. Globally, Dalkia has a wealth of experience in data center energy asset design, commissioning, and O&M. Data centers around the world also leverage Dalkia s district energy networks to meet their cooling requirements. The following centers are international examples of those at which we provide performance guarantees for O&M, building management, monitoring, or district cooling: Telehouse Hosting Centres in France Tier IV Data Centres 16,500 m² of computing rooms Operation, Maintenance, Facility Management and monitoring for all sites in France Polaris Computing Hub, Springfield TIER III Data Centre 7,000 m² of computing rooms 48 hours of autonomy Operation, Maintenance, Facility Management and monitoring SFR Management of strategic sites and of the Sud France network Tier III, IV Data Centres From 500 to 20,000 m² of computer rooms (10 Data Centres) Operation, Maintenance, Facility Management and monitoring EDF NOE Data Centre at Val-de-Reuil TIER IV Data Centre 9,000 m² of computing rooms Operation, Maintenance, Facility Management and monitoring Energy Optimization For more details about Sustainable Data Center management call us at +46 8 550 500 00 or email us at: datacenter@dalkia.se www.dalkia.se