Specifications may be subject to change for improvement without prior notice

Similar documents
Triple Waveband Infra-Red Flame Detection

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Digital inductive conductivity transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Application Requirement

Compact pressure switch Flameproof enclosure Ex d Model PCA

Buckeye Detection Systems Fixed Detection Systems Application Survey

Terminal Boxes Series 8146

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Fire & Security DETECTORS

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ALARMLINE ANALOGUE Linear Heat Detection System

RAEGuard EC FGM-13XX

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Duct Humidity Transmitter

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

EXPLORER 4 MULTIPOINT

Explosion proof enclosures

How To Use A Ds340 (Dsp)

Technical Data. Dimensions

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Online Infrared Flue Gas Analyzer Gasboard 3000

SEISMIC VELOCITY TRANSDUCER T1-40

Engineering Specifications XNX Universal Transmitter

Ultima X Series Gas Monitors

Technical data sheet TDS0070

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Instruction Manual. T3111 T3111L T3111P T3111Ex

S300 Series Dust Monitors

Series 8146/5-V37 and Series 8150/5-V37

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Rosemount 752 FOUNDATION fieldbus Remote Indicator

T0118 T2118 T3118. Instruction Manual

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Plastic tube flowmeters Series PT/PS

FGM 160 ATEX EC type examination certificate

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Linear Luminaire with LED Series EXLUX 6402/2

For Multi-Parameter Meters see mvx

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Sieger Searchpoint Optima Plus

Technical Information RIA14

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

2.24. Pump Controller 704. Data Sheet

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

PART 1 - INTRODUCTION...

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Rosemount 333 HART Tri-Loop

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Analytical Instruments Smart Analyzer 90 Type SMA

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Model: DC-A2IO Advanced HVAC Controller

Telephone- and leased line modem for industrial applications TD-36

Combi switchbox with integrated 3/2 way pilot valve

Flow switches Series AD/VH

Original instructions Tina 3A/Aps Adaptor unit

SELECTION, APPLICATION AND MAINTENANCE

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Micro Motion 3098 Gas Specific Gravity Meter

Capteur température et humidité pour HVAC

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Temperature & Humidity SMS Alert Controller

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Tina 2A/B Adaptor unit

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

400 Series - Mini USB Buccaneer

Rosemount 333 HART Tri-Loop

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Heating, air-conditioning, cooling

Model 3051 Pressure Transmitter with HART Protocol

The Ambient Air Monitoring System

Inductive sensor NI10-M18-Y1X-H1141

2.12. page Products for Explosion hazardous Environment

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

Flameproof Audible Signal 115 db (A) Series YA90

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Transcription:

Gas Detector $,7B4.:'( ) Part no. 3242 System: Gas Alarm System Description KVD is a group name for detectors in the Salwico gas alarm programme for detection of explosive, toxic or inflammable fluids and gases. KVD detectors are intended for use in heavy-duty industrial environments and can be adapted for detection of different gases depending on which semiconductor sensor it is equipped with. The KVD detector consists of an aluminium junction box and a sintered housing around the sensor. The KVD is connected to the central unit via a screened 3-core cable. KVD(COD) is intended for detection of carbon monoxide (CO). The KVD(COD) also includes a dust filter to minimise interference from other gases. Technical data Cable connection to See connection diagram gas alarm central for gas detector Enclosure protection IP-54 Cable entry 6-11 mm Temperature range -40 - +85 C Relative humidity 0-95% Material connection box Varnished aluminium Weight 350 g Colour Grey box with nickelplated sintered housing Dimensions (mm) 75 86 111 53 Connection Specifications may be subject to change for improvement without prior notice H:9>474@8 Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 3242.01.1.E

Gas Detector BUTOX ST400EC Part no. 4461 O 2 4462 H 2 S 4463 CO System: Salwico GS3000, SW2020 Description The BUTOX ST400EC gas detector to measure oxygen, toxic or flammable gases consists of a chrome plated ABS-housing with transmitter print, sensor and sensor holder in stainless steel. The transmitter print is based on the one man calibration technology. This means that one person can make all the necessary calibrations inside the detector head, without the necessity of a second calibration procedure on the measurement module. Measuring Range CO 0-250 ppm H 2 S 0-30 ppm O 2 0-25 % Data Weight ~470 g Material housing Chrome plated ABS Sensor housing SS 316 Power supply 12-30 VDC Signal 4-20mA (2-wire) Sensor 2- or 3-electrode Measuring principle Electrochemical cells Temperature range -40 C to +60 C Protection class IP65 (excl. sensor) Cable entry Od Ø 8-13.5 mm Optional certificate class* EEx ia IIC T6, T amb -40 C to +60 C *If used with a specified safety barrier. Sensors for other toxic gases are available upon request. Dimensions (mm) Connection 120 172 Mounting holes 110 122 43 55 90 145 Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 4461 04 1 E

Gas Detector BUCOM ST600EX Part no. 4460 System: Salwico GS3000, SW2020 Description The BUCOM ST600EX gas detector for combustible gases is assembled with an EExd sensor, housing and cable gland. The transmitter is based on the so-called one man calibration principle, which means that the calibration takes place at the detector head only. The sensor is a replaceable catalytic oxidation sensor and consists of detection and reference elements that are provided in a wheatstone bridge. When exposed to gas, the bridge will be unbalanced and an electric signal proportional to the gas-concentration will be converted to a 4-20mA output signal. Sensors for other explosive gases are available upon request. When installing BUCOM ST600EX in ventilation ducts, the air duct mounting kit part. no. 4490 shall be used, see separate drawing. Data Weight 2.8 kg Material housing Steel coated Sensor housing SS 316 Power supply 18-35 VDC Power consumption 1.7 W Output signal 4-20mA (3-wire) Response time t90 < 15sec. Sensor lifetime Min. 3 years in air Measuring principle Catalytic Measuring range 0-100% LEL Temperature range -20 C to +60 C Protection class IP65 (excl. sensor) Cable entry Od Ø 10-16 mm Ex class EEx-d IIC T6 Certificate KEMA No. Ex.99.E.1378 Cable spec. Shielded, min. 3x0.75mm 2 Cable resistance Max 100Ω at 24VDC Max 200Ω at 30VDC Dimensions (mm) Connection 194 Mounting holes 183 81 Ø7 76 Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 4460 04 1 E

Gasdetektor Salwico KVD-Ex KVD-Ex är en detektor ingående i Salwico gaslarmsprogram för detektering av explosiva, giftiga och brännbara vätskor och gaser. KVD-Ex är avsedd för tuff inomeller utomhusmiljö och den är godkänd för installation i Ex-klassade områden, zon 1 eller motsvarande. KVD-Ex anpassas för detektering av olika gaser genom att den kan bestyckas med olika halvledarsensorer. KVD-Ex består av en kopplingsdosa av polyester och ett sensorhus av rostfritt stål. KVD-Ex är typgodkänd av Nemko. u9090303.doc 1(2) çconsilium

Dimensioner (mm) Anslutningar Data Kabelförbindning med gaslarmscentral Kapslingsgrad Se separat inkopplingsschema Material sensorhus Rostfritt stål (SIS2343) IP-65 Mätprincip Halvledare (Figaro TGS) kopplingsdosa Kabelgenomföring 10 15 mm Ex-skyddsklass EEx de IIC T6 Temperaturområde -40 - +85 Vikt 900 g Relativ fuktighet 0 95% Färg kopplingsdosa Svart Material kopplingsdosa Polyester Färg sensorhus Blank metall Artikelnummer 3122 *) Hela detektorn håller IP-65 om den förses med speciellt stänkskydd för sensorhus. Se separat ritning. u9090303.doc 2(2) çconsilium CONSILIUM SECURITY SYSTEMS AB P.O. Box 8763 SE-402 76 GÖTEBORG SWEDEN Besöksadress: Salsmästaregatan 21 Ringön GÖTEBORG Telefon: Nat 031-710 79 00 Int +46 31 710 79 00 Telex: 20660 consmar s Telefax: Nat 031-710 79 99 Int +46 31 710 79 99

Gas Detector Salwico KVD-Ex KVD-Ex is a detector type included in the Salwico gas alarm program for detection of explosive, toxic and inflammable fluids and gases. KVD-Ex is intended for heavy environments, both indoors and outdoors and is approved for installation in Ex classified areas. KVD-Ex can be adapted to detect different gases when equipped with semiconductor sensors. KVD-Ex consists of a junction box of polyester type and a sensor housing of stainless steel type. KVD-Ex is type approved. u9090302.doc 1(2) çconsilium

Dimensions (mm) Connection Data Cable connection to central panel Enclosure protection See separate connection diagram no. Sxxx319 Material sensor housing Stainless steel (SIS2343) IP-65 Measuring principle Semi-conductor (Figaro TGS) junction box *) Cable connection 10 15 mm Ex protection class EEx de IIC T6 Temperature range -40 - +85 Weight 900 g Relative humidity 0 95% Colour junction box Black Material junction box Polyester Colour sensor housing Metal Part no 3122 *) The entire detector will meet IP-65 if fitted with a special protector for sensor housing. See separate data sheet. u9090302.doc 2(2) çconsilium CONSILIUM MARINE AB P.O. Box 8763 SE-402 76 GÖTEBORG SWEDEN Visiting address: Salsmästaregatan 21 Ringön GÖTEBORG Telephone: Nat 031-710 77 00 Int +46-31 710 77 00 Telex: 20660 consmar s Telefax: Nat 031-710 78 00 Int +46 31 710 78 00

Local Gas Indicator Salwico LGI Part no. 17250 C x H y 17251 O 2 17252 CO 17253 CO 2 17254 H 2 S System: Salwico GS3000 Gas Alarm system Description The Salwico LGI local gas indicator is an LCD display intended for local display of a gas detector connected to the GS3000 Gas Alarm System. The Salwico LGI continuously displays the gas reading. The Salwico LGI shall be connected on the signal line between the gas transmitter and the SM13 or SM13/11. The lid of the Salwico LGI can also be mounted directly on a SM13/11, since the lids have the same dimensions. Data Input current Ambient temperature Protection class Function Material Cable Weight Colour 4 20 ma 25 to +55 C IP66 Analogue Polystyrol OD Ø10 16 mm ~0.4 kg Grey Dimensions (mm) Connection Salwico LGI Local Gas Indicator ÇConsilium Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 17250-54 05 2 E

Sensor module $,7B4.:$ Part no. 17213 System: GS3000 Gas Alarm System Description The SM13 is an explosion proof addressable unit with an interface for gas detectors. It is intended for use with Salwico Gas Alarm System GS3000 and can interface to gas detectors with a 0-20 ma transmitter interface. The SM13 detects when the gas concentration exceeds the user-defined low and high gas alarm levels. The unit continuously monitors the gas detector for faults and also checks the supply voltage of the detector interface. The combination of the double-sided communication loop and two built-in short circuit isolators makes the SM13 invulnerable to any short circuit or cable break. The sensor module is designed according to the requirements of IMO and the European Community. Dimensions (mm) 9 7 9 94 112 Technical data Detector voltage 24 ± 6 VDC 0 20 ma Interface max 30 ma Ambient temperature 25 to +55 C Explosion class Eex em II T5 Function Analogue Material Polyester Cable OD 10 16 mm Weight 0.9 kg Colour Black Connection Cable 1 Cable 2 1: Loop in + 3: Loop out + 2: Loop in 4: Loop out - 10: 24 V + 11: 24 V + 14: 24 V 15: 24 V - Cable 3 Cable 4 13: Ext. Alarm + 12: 24 V + 14: Ext. Alarm - 16: 24 V - 18: 0-20 ma + 19: 0-20 ma - 7 26 131 118 170 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Cable 1 Cable 2 Cable 3 If applicable Cable 4 Setting the address Cut the connectors at 6, 7, 8 or 9 to get the required address. E.g. cut connectors 6 and 8 (Bit 0 and Bit 2) to get address 10. The address is preset to 15 on delivery. Addr Cut Addr Cut Addr Cut 1 7,8,9 6 6,9 11 8 2 6,8,9 7 9 12 6,7 3 8,9 8 6,7,8 13 7 4 6,7,9 9 7,8 14 6 5 7,9 10 6,8 15 No cut Specifications may be subject to change for improvement without prior notice H:9>474@8 Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 17213.01.2.E

Sensor module $,7B4.:$ Part no. 17211 System: GS3000 Gas Alarm System Description The SM13/11 is an addressable unit with an interface for gas detectors. It is intended for use with Salwico Gas Alarm System GS3000 and can interface to gas detectors with a 0-20 ma transmitter interface. The SM13/11 detects when the gas concentration exceeds the user-defined low and high gas alarm levels. The unit continuously monitors the gas detector for faults and also checks the supply voltage of the detector interface. The combination of the double-sided communication loop and two built-in short circuit isolators makes the unit invulnerable to any short circuit or cable break. The sensor module is designed according to the requirements of IMO and the European Community. Dimensions (mm) 130 115 Mounting holes 4x Ø5mm 75 Technical data Detector voltage 24 ± 6 VDC 0 20 ma Interface max 30 ma Ambient temperature 25 to +55 C Protection class IP66 Function Analogue Material Polystyrol Cable OD 10 16 mm Weight 0.4 kg Colour Grey Connection Cable 1 Cable 2 1: Loop in + 3: Loop out + 2: Loop in 4: Loop out 10: 24 V + 11: 24 V + 14: 24 V 15: 24 V Cable 3 Cable 4 13: Ext. Alarm + 12: 24 V + 14: Ext. Alarm 16: 24 V 18: 0-20 ma + 19: 0-20 ma 130 115 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Cable 1 Cable 2 Cable 3 If applicable Cable 4 Setting the address Cut the connectors at 6, 7, 8 or 9 to get the required address. E.g. cut connectors 6 and 8 (Bit 0 and Bit 2) to get address 10. The address is preset to 15 on delivery. Addr Cut Addr Cut Addr Cut 1 7,8,9 6 6,9 11 8 2 6,8,9 7 9 12 6,7 3 8,9 8 6,7,8 13 7 4 6,7,9 9 7,8 14 6 5 7,9 10 6,8 15 No cut Specifications may be subject to change for improvement without prior notice H:9>474@8 Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 17211.01.3.E

Gas Detector BUCOM ST200 Part no. 4470 System: Salwico GS3000, SW2020 Description The BUCOM ST200 gas detector for combustible gases is assembled in a chrome-plated ABS housing. The transmitter is based on the so-called one man calibration principle, which means that the calibration takes place at the detector head only. The sensor is a replaceable catalytic oxidation sensor and consists of detection and reference elements that are provided in a wheatstone bridge. When exposed to gas, the bridge will be unbalanced and an electric signal proportional to the gas-concentration will be converted to a 4-20mA output signal. Sensors for other explosive gases are available upon request. Dimensions (mm) Data Weight ~500 g Material housing Chrome plated ABS Sensor housing SS 316 Power supply 18-35 VDC Power consumption 1.7 W Measuring range 0-100% LEL Response time t90 < 15sec. Relative humidity 0-99% (non condensing) Signal 4-20mA (3-wire) Measuring principle Catalytic Sensor lifetime Min. 3 years in air Temperature range -20 C to +60 C Protection class IP65 (excl. sensor) Cable entry Od Ø 10-16 mm Cable spec. Shielded, min. 3x0.75mm 2 Cable resistance Max 100Ω at 24VDC Max 200Ω at 30VDC Connection 120 172 Mounting holes 110 122 Ø4.3 55 90 145 Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 4470 05 1 E

Gas Detector BUCOM ST200 Part no. 4470 System: Salwico GS3000, SW2020 Description The BUCOM ST200 gas detector for combustible gases is assembled in a chrome-plated ABS housing. The transmitter is based on the so-called one man calibration principle, which means that the calibration takes place at the detector head only. The sensor is a replaceable catalytic oxidation sensor and consists of detection and reference elements that are provided in a wheatstone bridge. When exposed to gas, the bridge will be unbalanced and an electric signal proportional to the gas-concentration will be converted to a 4-20mA output signal. Sensors for other explosive gases are available upon request. Dimensions (mm) Data Weight ~500 g Material housing Chrome plated ABS Sensor housing SS 316 Power supply 18-35 VDC Power consumption 1.7 W Measuring range 0-100% LEL Response time t90 < 15sec. Relative humidity 0-99% (non condensing) Signal 4-20mA (3-wire) Measuring principle Catalytic Sensor lifetime Min. 3 years in air Temperature range -20 C to +60 C Protection class IP65 (excl. sensor) Cable entry Od Ø 10-16 mm Cable spec. Shielded, min. 3x0.75mm 2 Cable resistance Max 100Ω at 24VDC Max 200Ω at 30VDC Connection 120 172 Mounting holes 110 122 43 55 90 145 Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 4470 04 1 E

Flame arrester Salwico FTH-1/4 Part no. 4227 System: Salwico gas alarm systems Description The Flame arrester Salwico FTH-1/4 is designed to meet the requirements for explosion proof penetration of bulkheads and walls between safe and dangerous areas, with sample and exhaust pipes for gas sampling and detection systems. Data Material: Body and filter: Stainless Steel 316L O-ring: Viton Explosion group: IIA, IIB and IIC Weight: 85 g Part no.: 4227 Dimensions (mm) Specifications may be subject to change for improvement without prior notice ÇConsilium Consilium Marine AB P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se Data sheet no: 4227.03.1.E