Q-AMS Data Acquisition (DAQ) Software



Similar documents
Setting up a Quantitative Analysis MS ChemStation

How To Use An Ionsonic Microscope

Transmitter Interface Program

Quick Start. AirCard 340U USB Modem

XF Extracellular Flux Analyzer. Installation and Troubleshooting Guide

Appendix C I/O Hardware Installation

Moxa Device Manager 2.0 User s Guide

================================================================== CONTENTS ==================================================================

HDHomeRun Troubleshooting Guide ( )

Installing IDEA v8 Client Software on Citrix Server Environment

Moxa Device Manager 2.3 User s Manual

Using Internet or Windows Explorer to Upload Your Site

Tutorial 9: SWATH data analysis in Skyline

System update procedure for Kurio 7 (For build number above 110)

Tuning & Mass Calibration

WorldShip Install on a Single or Workgroup Workstation

ElectricCommander. Technical Notes MS Visual Studio Add-in Integration version version 3.5 or higher. October 2010

airbackup installation and AdmiCash backup

Windows 8 UEFI BIOS Update (Step-by-Step Guide)

FTP Updates. Hiden Analytical Limited 420 Europa Boulevard Warrington WA5 7UN England. Tel: +44 (0) Fax: +44 (0)

Driver Updater Manual

================================================================== CONTENTS ==================================================================

M2GO & M1 Operating System Installation

Installation Assistance Windows/Microsoft Updates Updating from Spectra or Upgrading from Spectra 6.x...

Setting up FileMaker 10 Server

ESET REMOTE ADMINISTRATOR. Migration guide

Solve network scan problems. Common problems and solutions Scan to status Scan to FTP status Job Accounting status...

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 16 Fixing Windows Problems

Vehicle Fleet Manager 3.0. User guide

Module 2 Using the Database

MassLynx 4.1 Getting Started Guide

Jumble for Microsoft Outlook

MAS 90. Installation and System Administrator's Guide 4WIN /04

The service note describes the basic steps to install a ip camera for the DVR670

JVC Monitor Calibration 2 User's Guide

TM Online Storage: StorageSync

DAQlink III System 24 bit Acquisition System

HIC.SOAP Network User Instructions last updated June 22, :39 AM

Centurion PLUS CPC4 Download Guide

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Case Closed Installation and Setup

Version 4.61 or Later. Copyright 2013 Interactive Financial Solutions, Inc. All Rights Reserved. ProviderPro Network Administration Guide.

TANDBERG MANAGEMENT SUITE 10.0

Installing MINITAB. Networks, Labs, and Stand-Alone PCs

Cobian9 Backup Program - Amanita

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

HP ProLiant Essentials Vulnerability and Patch Management Pack Release Notes

1. System Requirements

Pocket Verifier Quick Start HTC Touch Diamond

Understanding Backup and Recovery Methods

Moldplus Server Installation Guide Version 3.10 Revision date: February 05, 2006

Juris Installation / Upgrade Guide

Abila MIP. Installation User's Guide

Micromass LCT User s Guide

Error: "Object reference not set to an instance of an object" When Opening Any Database

Installing Autodesk Vault Server 2012 on Small Business Server 2008

Shimadzu UV-VIS User s Guide

HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number

BUSINESS SOFTWARE SOLUTIONS. Business Software Solutions Error Troubleshooting

Setup for PCCharge. Important Pre-Installation Notes for PCCharge. Installation Overview. Step 1 Install And Set Up PCCharge on the Fileserver

SQL 2014 Configuration Guide

NETGATE Data Backup. User Manual. Document version 1. 1 EN ( ) Copyright (c) 2010 NETGATE Technologies s.r.o. All rights reserved.

MTS Remote Drive Service. Quick Start Guide

Xerox 700 Digital Color Press with Integrated Fiery Color Server. Utilities

Installing Novell Client Software (Windows 95/98)

NOTE: You may want to choose the Word Wrap option from Notepad Edit menu to make this text more readable.

Installation Guide for Workstations

Basic Computer Maintenance

Project Server 2003 Install on SBS 2003 Courtesy of Chris Jones All rights reserved by the Author

Contents. Business Everywhere user guide. 1. Introduction. 2. How to Install/Uninstall Business Everywhere. 3. The Business Everywhere interface

Oracle Call Center Applications Setup

Primavera P6 Professional Windows 8 Installation Instructions. Primavera P6. Installation Instructions. For Windows 8 Users

TIGERPAW EXCHANGE INTEGRATOR SETUP GUIDE V3.6.0 August 26, 2015

Analysis of Liquid Samples on the Agilent GC-MS

ProperSync 1.3 User Manual. Rev 1.2

Outlook Hosted Exchange Account Configuration

Lab 3: Introduction to Data Acquisition Cards

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /02/24

Super Pro Net TM Network Key Installation and Operation

OPENGATE DATABASE MANAGER FOR MICROSOFT ACCESS

DISK DEFRAG Professional

This document details the following four steps in setting up a Web Server (aka Internet Information Services -IIS) on Windows XP:

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

DocAve Upgrade Guide. From Version 4.1 to 4.5

JPD-FFB-A Vibration USB gamepad with audio USER MANUAL

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Personal Folders Backup

ScriptLogic File System Auditor User Guide

MS SQL Express installation and usage with PHMI projects

SOS Suite Installation Guide

FTP Manager. User Guide. July Welcome to AT&T Website Solutions SM

DPS Telecom Your Partners in Network Alarm Management

BlackBerry Desktop Software User Guide

User Manual. Copyright Rogev LTD

Transcription:

Q-AMS Data Acquisition (DAQ) Software 6 th AMS Users Meeting University of Minnesota, Minnesota Sep, 2006 Update on Q-AMS Data Acquisition Software Status Current Software Version: V 4.6 Software versions that are most widely distributed right now: AMS Versions V 4.5.9, 4.4.4. and 4.3.mode Updated Features include: Fixed bug on JMS mode, pointed out by Jonny Crosier, in which the AB in JMS mode was lower than in MS and PTOF modes. Added new TSI CPC types as option including switch between old and new CPC types Eddy Correlation additions * For most applications, there is very little different difference between the two I recommend that you all update to V 4.6! 1

Old CPC Type: 3010,3022,3025,3760.3761 New CPC Type: 377x,378x Downloading AMS DAQ Software 1) Aerodyne ftp site: AMSIncoming\AMSUsers\ALLUsers\AMSSoftware 2) Jose s Q-AMS Web Page http://cires.colorado.edu/jimenez-group/qamsresources/ You will be prompted for the Username/Password combination for both these sites 2

Jump MS Data Acquisition Description Jump Mass Spectrum Operation 3

Jump MS mode Like MS mode, but scanning only a few m/z Like selected ion monitoring (SIM) in GC- MS Scan m/z once Go to peak m/z 30 m/z 48 Move On to Next m/z S/N Improvement in Jump-MS 40x10 3 Ion Rate (Hz) 20 0 MS mode m/z 44 JMS mode m/z 44 MS mode m/z 44 (smoothed) -20 08:00 27/08/2004 09:00 10:00 Date and Time Flight Data Courtesy of J. Crosier (UMIST) 4

10 Hz Jump Mode Sensitivity F N = w'χ' N = w χ N w χ N 1 w [m s -1 ] 0-1 up-draughts -2 15 0 60 down-draughts 120 180 240 300 360 420 [µg m -3 ] NO 3-10 5 0 0 60 120 180 relative time [s] Example Time-Series Measured with AMS (Urban Emission of NO 3- ) Courtesy E.Nemitz (CEH, Scotland) Obtained with Eddy Type2 Mode programmed by Jose Jimenez 240 300 360 420 Jump-MS Screen NOTES: In data acquisition boards menu tab the acquisition rate for JMS needs to be specified for the JMS Mode. Scanned m/z s are from F6 Screen Settings. First m/z scanned provides DC level. So it should be one with no particle signal. Data is saved in JMS.itx (Analogous to MS.itx) 5

General Alternation Mode ( GENALT ) Alternate TOF, MS, JMS Or any two of them Variable time for each mode Implemented as separate mode from old TOF-MS alternate mode At present (v. 4.4.8) both modes work In future probably only support GENALT Menu Parameters For General Alternation Mode 6

Useful Background Information For AMS Data Acquisition Program AMS Software problems 1) Check Menu (especially if problem is sudden) Gets corrupted if program crashes or is exited in nonstandard way At least 50% of problems are due to this C:\AMS\AMSCode\AMSMenu.prm A copy is saved on AMSLogFiles directory (C:\AMS\AMSData\AMSLogFiles) every day you use the program (i.e. 041011_Menu.prm for today s menu ) Also saved in every ITX file ( par and ParStr ) Compare you current menu with a known good one side-by-side in Excel Make backups of known good menus 7

AMS Software problems 2) Runtime Error # 6 - Typically occurs in TOF mode only not in MS mode. It is often because of a drop out of the chopper signal. - chopper signal can drop out if bad lsignal coming from diode or chopper wheel is not spinning when chopper servo moves through the block/chop/open cycles - Software crash due to this error will be prevented in future software versions 3) Check TOF velocity calibration. This can cause division by zero issues Most Current Software problems due to either menu corruption or Chopper signal issues! Troubleshooting Software Problems Information Needed: 1) Software version 2) Exact error message 3) Operating mode (Alternating, TOF Mode only,ls On ) 4) What mode the error occurs in (TOF/MS /JMS) 5) Any keystrokes that may have caused error 6) AMSMenu.prm 8

Downloading Application Setup Program You MUST update the Application Setup Program to the Win2K Version in order to run new version of AMS program. The Win2K Application Setup can be downloaded from the ARI FTP site in the following folder: AMSIncoming\AMSUsers\ALLUsers\AMSSoftware\Installs\Win2KInstalls OR http://cires.colorado.edu/jimenez-group/qamsresources/ Installing Application Setup Program 1) Uninstall previous Application Program - go to Start\Settings\ControlPanel\AddRemoveSoftware - Remove Program called AMS 2) Install the Win2000 Application Program - Shut down all other programs - Go to copy of Win2KInstalls folder and start the Setup.exe NOTE: Ignore the message that reports a conflict with the shdocvw.dll 9

Software Requirements During Field Campaigns CD s containing the following files should be available: 1) NIDAQ Software 2) AMS Application Setup Folder from ftp site 3) AMSMenu.prm and AMSID.prm files. AMS Program Requirements 1) Pre-installation of the appropriate AMS Application Setup Program 2) Pre- installation of the NIDAQ Software for slow/fast Data Acquisition Boards NOTE: The NIDAQ EXAMPLES FILE MUST ALSO BE INCLUDED IN INSTALLATION - NIDAQ intallation process places files accessed by AMS program(i.e. NIDAQ32.dll and NIDEX32.dll) in C:\winnt\System32 folder. 3) The computer C drive must contain a C:\AMS\AMSCode folder with the following files: a) AMSMenu.prm b) AMSID.prm files. 10