Components of a Mass Spectrometer. P. Babu, Ph. D. Centre for Cellular and Molecular Platforms

Similar documents
Electrospray Ion Trap Mass Spectrometry. Introduction

13C NMR Spectroscopy

AMD Analysis & Technology AG

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Pesticide Analysis by Mass Spectrometry

Appendix 5 Overview of requirements in English

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

How To Use Gc-Ms

Mass Spectrometry. Overview

F321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom

Ionization Methods in Organic Mass Spectrometry Contents:

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Summary of the characteristics of different mass analyzers

Università degli Studi di Bari SPETTROMETRIA DI MASSA

High resolution mass spectrometry (HRMS*) in Graz

Functional Data Analysis of MALDI TOF Protein Spectra

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

m/z

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Nuclear Structure. particle relative charge relative mass proton +1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Waters Core Chromatography Training (2 Days)

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

Mass Spectrometry Based Proteomics

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

How To Build An Amd Quas 3 Ar Mass Spectrometer

Introduction 1 Christopher Barner-Kowollik, Jana Falkenhagen, Till Gruendling, and Steffen Weidner References 4

Time-of-Flight Mass Spectrometry

Mass spectrometry. Dr. Kevin R. Tucker

CONTENTS. PART I INSTRUMENTATION 1 1 DEFINITIONS AND EXPLANATIONS 3 Ann Westman-Brinkmalm and Gunnar Brinkmalm References 13

CHE334 Identification of an Unknown Compound By NMR/IR/MS

TOF FUNDAMENTALS TUTORIAL

LC-MS/MS for Chromatographers

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Workshop IIc. Manual interpretation of MS/MS spectra. Ebbing de Jong. Center for Mass Spectrometry and Proteomics Phone (612) (612)

Best Practice Guide. for Generating Mass Spectra. Authors: Vicki Barwick John Langley Tony Mallet Bridget Stein Ken Webb

Electrospray Mass Spectrometry of Tris-acetylacetonatochromium(III)

L. Yu et al. Correspondence to: Q. Zhang

CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS

Infrared Spectroscopy 紅 外 線 光 譜 儀

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

QGA Quantitative Gas Analyser

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis

- thus, the total number of atoms per second that absorb a photon is

Background Information

Master course KEMM03 Principles of Mass Spectrometric Protein Characterization. Exam

Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF

Principles and Applications of LC-MS/MS for the Quantitative Bioanalysis of Analytes in Various Biological Samples

Introduction to Proteomics 1.0

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

THE BASICS OF MASS SPECTROMETRY IN THE TWENTY- FIRST CENTURY

Introduction to mass spectrometry (MS) based proteomics and metabolomics

Guide to achieving reliable quantitative LC-MS measurements

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

How To Use An Ionsonic Microscope

Introduction to Mass Spectrometry. W.M. Keck Biomedical Mass Spectrometry Lab

Application Note # MT-103 FAST-SRM: A new Single Reaction Monitoring Method for Fast, Targeted Drug Distribution Testing in Tissue Sections

Analyzing Small Molecules by EI and GC-MS. July 2014

Secondary Ion Mass Spectrometry

Ultraviolet Spectroscopy

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Amount of Substance.

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

[ Care and Use Manual ]

Identification of Surfactants by Liquid Chromatography-Mass Spectrometry

Laboration 1. Identifiering av proteiner med Mass Spektrometri. Klinisk Kemisk Diagnostik

NMR SPECTROSCOPY A N I N T R O D U C T I O N T O... Self-study booklet NUCLEAR MAGNETIC RESONANCE δ PUBLISHING

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

SPECIAL FEATURE: TUTORIAL

Proteomics in Practice

3 - Atomic Absorption Spectroscopy

The Mole Concept. The Mole. Masses of molecules

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

INFRARED SPECTROSCOPY (IR)

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

Getting the most from this book...4 About this book...5

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

Vacuum Evaporation Recap

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

ESTEC-8. Peter J. Hatton & Barry W.L. Southward

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Transcription:

Components of a Mass Spectrometer P. Babu, Ph. D. Centre for Cellular and Molecular Platforms

Relative abundance Mass spectrometer Mass spectrometer is an instrument that measures the mass-tocharge ratio (m/z) values and their relative abundances of ions................. Mass spectrum m/z mass to charge ratio Base peak Isotopic peak Molecular ion m/z

Mass Mass unit 1 u = 1 Da = 1.660 540 10 27 kg. Molecular mass : Exact mass of an ion or molecule calculated using the mass of the most abundant isotope of each element Molar mass: Mass of one mole (6x10 23 atoms or molecules) of a molecule/compound (i.e. isotope-averaged atomic mass for the constituent elements)

MS principle e - D + + R. M M +. 2e - D +. + N M + -Molecular ion; D + - Daughter ion or product ion Only charged species are detected in MS e.g. [M+nH] n+ ; [M-nH] n- ; [M+Na] +

JJ Thamson s 3 rd Parabola Mass Spectrograph

Components of a Mass Spectrometer........... Sample Inlet Ion Source Analyzer Detector Data collector and processor HPLC GC Syringe Plate Capillary Electron Ionization (EI) Chemical (CI) APCI APPI Electrospray (ESI) Fast Atom Bombardment (FAB) MALDI Sector Quadrupole TOF Orbitrap FTICR Photoplate Faraday cup Electron multipliers (MCP) Solid-State Image current

Sample Inlet HPLC GC Syringe Plate Capillary

Ion source The role of the ion source is to create gas phase ions 1) Analyte atoms and molecules are transferred into gas phase 2) Ionization Hard (high energy) ionization and Soft (low energy) ionization Electron Ionization (EI) Chemical (CI) Spray Ionization (APCI, APPI, ESI) Desorption Ionization (FAB, MALDI, SALDI) Gas discharge ion sources (e.g. Inductively Couple Plasma) Ambient Ionization (DESI, LAESI)

Electron impact ionization (EI) High energy (70 ev) ionization fragmentation of molecules Chemical Ionization (CI) is similar to EI except that a reagent gas is ionized first which in turn transfers charge to analyte molecules or an atom

Electrospray ionization Taylor cone The exact mechanism of ion formation is still not clear Multiple charged ions are produced Sensitivity depends upon the flow rate of analyte solution Very soft ionization less fragmentation, non-covalent complex

Fast atom bombardment (FAB) Liquid sample (matrix is mixed with sample) is bombarded with energetic atoms (Xe or Ar atoms of 10KeV); ions are generated through sputtering Predominantly singly charged ions are formed Chemical background due to matrix cluster ions and fragments are disadvantages Soft ionization fragmentation gives partial sequence information

Matrix Assisted Laser Desorption Ionization (MALDI) Sample is mixed with a matrix (light-absorbing, low-mass molecules) and excited with UV laser pulse (ns) Different matrix molecules are used for different classes of analytes Ionization is done at very low pressure (<10-6 torr) Very soft ionization good ion source for biomolecules

Analyzers A mass analyzer is a device that can separate atoms and molecules according to their mass Sector Quadrupole TOF Orbitrap FTICR The five main characteristics for measuring the performance of a mass analyzer are 1) the mass range limit or dynamic range 2) the analysis speed [u (m)s -1 ] 3) the transmission = No. of ion reaching the ions/no. of ions entering mass analyzer 4) the mass accuracy 5) the resolution

Resolution and Mass accuracy Resolution = FWHM = m/m Mass accuracy = theoretical m/z vs measured m/z (ppm)

Sector analyzer m/z = B 2 r 2 /2V

Sector analyzer Benefits Double focusing magnetic sector mass analyzers are the "classical" model against which other mass analyzers are compared.. Classical mass spectra. Very high reproducibility. Best quantitative performance of all mass spectrometer analyzers. High resolution. High sensitivity. High dynamic range. Linked scan MS/MS does not require another analyzer. High-energy CID MS/MS spectra are very reproducible Limitations. Not well-suited for pulsed ionization methods (e.g. MALDI). Usually larger and higher cost than other mass analyzers. Linked scan MS/MS gives either limited precursor selectivity with unit product-ion resolution, or unit precursor selection with poor product-ion resolution

Quadrupole analyzer

Quadrupole analyzer Benefits. Classical mass spectra. Good reproducibility. Relatively small and low-cost systems. Low-energy collision-induced dissociation (CID) MS/MS spectra in triple quadrupole and hybrid mass spectrometers have efficient conversion of precursor to product Limitations. Limited resolution. Peak heights variable as a function of mass (mass discrimination). Peak height vs. mass response must be 'tuned'.. Not well suited for pulsed ionization methods. Low-energy collision-induced dissociation (CID) MS/MS spectra in triple quadrupole and hybrid mass spectrometers depend strongly on energy, collision gas, pressure, and other factors.

Time-of-flight (TOF) analyzer

Time-of-flight (TOF) analyzer Benefits. Fastest MS analyzer. Well suited for pulsed ionization methods (method of choice for majority of MALDI mass spectrometer systems). High ion transmission. MS/MS information from post-source decay. Highest practical mass range of all MS analyzers Limitations. Requires pulsed ionization method or ion beam switching (duty cycle is a factor). Fast digitizers used in TOF can have limited dynamic range. Limited precursor-ion selectivity for most MS/MS experiments

Orbitrap analyzer Harmonic oscillations Ions of specific mass-to-charge ratio move in rings which oscillate along the central spindle. The frequency of these harmonic oscillations is independent of the ion velocity and is inversely proportional to the square root of the mass-to-charge ratio (m/z or m/q). Hu et. al. J. Mass Spectrom. 2005; 40: 430 443

Comparison of various analyzers

Detectors The role of the detectors is to convert the energy of the incoming ions into a current signal that is registered by the electronic devices and transferred to the acquisition system of MS Photoplate Faraday cup Electron multipliers (MCP) Solid-State Image current (Orbitrap and FT ICR) Faraday Cup

Electron multipliers (MCP) MCP

MALDI or ES IONISATION MS x+ m/z COLLISIONAL ACTIVATION + + + + MS/MS m/z

Tandem MS (MS n )................... Ion Source Analyzer Analyzer Detector Collision Cell Data collector and processor

Hybrid Tandem MS Instruments Linear Detector Reflector Reflector improves the resolution Tribrid Fusion Orbitrap (Thermofisher) Source 2 region Timed ion selector Deceleration stack Collision cell Reflector detector Laser and Camera Q-Tof Sample plate Applied Biosystems, USA MALDI-TOF/TOF Source 1 region

References 1) Mass spectrometry Principles and applications by Edmond de Hoffmann 2) Mass spectrometry Instrumentation, interpretation and applications by R. Ekman, J. Silberring, A. W- Brinkmalm and A. Karj