Ventilation Unit Zehnder ComfoAir 160

Similar documents
Zehnder Focus 200. Ventilation device

CE6500 Energy Recovery Ventilator

Comfosystems Systems with heat recovery for a comfortable indoor climate

How To Get A Passive House

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

york air-conditioning products Residential & VRF News 2015

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Operation and Installation Manual. Max Series

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Bring the fresh in. Dedicated Outside Air Systems

Innovent LASER Packaged Fresh Air Conditioning Units

CADB and CADT-D / DI / DC Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

FTXS. Wall Mount Heat Pump or Cooling Only

KONRAD. Hybrid Fancoil Series

Unico Inverter. Unique and efficient.

How To Make Your House Breathe

ComfoAir 350 Luxe User Manual

FULL DC INVERTER SYSTEMS

squrboxbox heat recovery squrboxbox I technical information

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.


NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

WHOLE-HOUSE VENTILATION SYSTEMS

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Dehumidification Frequently Asked Questions

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Under sill units. Type FSL-B-ZAS

ECOCIAT. Domestic hot water heat recovery unit

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Installation, operation and maintenance manual TX 35A

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

HVAC air curtains. Type InduAir

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Combi Unit Genius. The energy efficient Building Service Centre

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

SECTION MORTUARY REFRIGERATORS

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Home inspectors are not mold inspectors, however they do inspect for defects that

Air-water systems for efficient air conditioning

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

The compact unit series

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

Lesson 36 Selection Of Air Conditioning Systems

saving energy in comfort Factsheet Recair Enthalpy

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

Split units TH with hermetic compressors

ComfoAir 550 Luxe Manual

Horizontal ventilation units

Inverter Air Conditioning for Light Commercial Use

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

FBQ. DC Duct Heat Pump or Cooling Only

Operating Instructions Split System Air Conditioner

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

Low Cost. Lower Energy Costs. Higher Efficiency.

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ECHO System for Basements

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Cooling Capacity CFM in. w.c. (125 Pa)

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Mechanical Rooftop Custom Capabilities

FLEXIT S4 R S6 R S7 R

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Incubator with mechanical convection

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

FTQ. Daikin Inverter Ducted Heat Pump

air conditioners how to choose a cooling system

Cooling kw Heating kw

IH E Sigma Island 90

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

HEAVY DUTY STORAGE GAS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Clinic Washer-Disinfectors. Washer-Disinfector Line

SWIMMING POOL HEAT PUMP Owners Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Transcription:

Use The ComfoAir 160 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation and very high efficiency. The CA160 moves up to 92 cfm of air at 0.80" wc Efficiency The integrated cross-counterflow heat exchanger achieves efficiencies of up to 88% (according to testing by the Passive House Institute). For user comfort this means no unpleasant cold drafts, because the supply air is heated nearly to room temperature, even when external temperatures are very low. Fans The supply fan and extract fan are driven by efficient DC motors. Differential pressures in the supply and extract air distribution systems can be adjusted thanks to individual control. The especially quiet fans can be adjusted to the required volumetric flow in 1% increments. The air volumes of the selectable stages can be set to between 19 cfm and 92 cfm. Filters The CA160 is equipped with two class G4 filters (MERV 7/8). An optional class F7 pollen filter (MERV 13) is available for fresh air intake. Installation The CA160 can be wall-mounted (vertically) or ceiling-mounted (horizontally). Connections for air and wiring are on the top of the unit. The insulated, soundabsorbing pipe connections can be rotated to optimize the location of the ventilation tubes while acoustically decoupling the CA160 from the air distribution system. The condensate drain is located on the bottom of the unit. Filter G4 Filter F7 Operation The CA160 is controlled by the ComfoSense controller, typically installed in the living area. Optional, wireless remote control units are installed in bathrooms for timed boost mode. Maintenance Maintenance of the CA160 is limited to periodic cleaning or replacement of the filters accessible from the front of the unit. The exchanger core should be inspected and cleaned annually (depending on outside air quality). Please see the unit manual for additional servicing tasks. ComfoSense controller Frost protection If the ventilation unit is operated without an optional geothermal heat exchanger, condensate in the extract air may freeze. The frost protection setting prevents this by variably reducing the supply air volume. An optional, integrated electric preheater warms incoming fresh air to prevent the heat exchanger from freezing even at very low temperatures. Remote Control Timer TS123-1 2015.03.23

Bypass During summer nights and in the shoulder seasons of spring and fall with strong sunshine, the house can become too warm, while the outside temperature remains pleasantly cool. In such cases, heat removal by what is known as free cooling helps: The CA160 is equipped with a standard automatic bypass for just this purpose, and diverts 100% of the relatively warm extract air from the heat exchanger, introducing cool supply air to the space. Options Humidity recovery with the Zehnder enthalpy exchanger When the CA160 is fitted with an enthalpy exchanger core, the humidity from the extracted air is partly transferred to the fresh supply air. In this case, the process of drying out the house in dry winter months is delayed. Additionally, there is no condensate that must be drained from the ComfoAir. Therefore a condensation drain is not necessary with an enthalpy exchanger. The Zehnder enthalpy exchanger provides the ideal hygienic solution. Supply and extract air flows are kept completely separate so there is no transfer of odors or bacteria. Pollen filter (F7/MERV 13) A pollen filter installed in the intake air line (upstream of the heat exchanger) keeps the inside of the house pollen-free and reduces particulates, spores and germs so occupants can breathe freely in times of increasing allergies. Wireless remote control With the Zehnder wireless remote control, the CA160 can be controlled from locations throughout the house, apartment, classroom, etc. Typically, one is installed in each bathroom to provide a boost function. Open fire program The ventilation system can be installed in a home with a fireplace, wood stove, etc. but must be accounted for in the control unit. By indicating in the ComfoSense controller the presence of a fireplace, negative pressure and possible back-drafting of unpleasant fumes and/or harmful gases can be avoided. TS123-2 2015.03.23

Benefits Comfort ventilation up to 92 cfm Heat recovery with an efficiency of 88% (according to PHI) Moisture recovery with optional Zehnder enthalpy exchanger Low power consumption DC motors Automatic summer bypass Frost protection function Quick, safe installation, maintenance and servicing Simple operation Optional, integrated electric pre-heater Wireless remote control/boost switch Filter replacement indicator Electric and hydronic post-heater integration possible CO2 control (optional) Relative humidity control (optional) Article Numbers L = supply air left R= supply air right VV = integrated electric pre-heater Product Article Number Reference Number CA160 HRV 471 218 210 9420 CA160 HRV-VV 471 218 215 9431 CA160 ERV 471 218 235 9421 Accessories Article Number Reference Number ComfoSense control unit 655 010 215 9257 Wireless remote control 655 000 755 9238 Waterless P-Trap 990 201 330 9362 Condensate drain (horiz.) 990 202 050 9450 Filters Article Number Reference Number G4 (MERV 7/8) 1 pc 400 100 023 9425 F7 (MERV 13) 1pc 400 100 024 9426 TS123-3 2015.03.23

Technical Specifications Heat Exchanger: Fans: Filters: Polystyrene ECM direct current, radial fans (2) Class G4 (MERV 7/8), F7 (MERV 13) optional Condensate Connection: 32mm Air Duct Connections: Electrical Connection: Acoustic Performance: Heat Recovery: Volumetric Flow: Power Consumption: 5 inside diameter (nominal); (2) top; (2) bottom. 230v, 50-60Hz Extract air (min max): 27-52 db(a) Supply air (min max): 26-49 db(a) 88% (according to PHI) 19cfm - 92cfm 10W 67W Dimensions: Height: 34 Width: 26.4 Depth: 10.6 Weight: Versions: 66.2 pounds (30kg) CA160 HRV CA160 HRV-VV CA160 ERV Manufacturer: Zehnder Group Nederland B.V. Lingenstraat 2 8028 PM Zwolle NETHERLANDS TS123-4 2015.03.23

Dimensional drawing 4.45" 17.52" 10.55" 5.15" Ø 5" 26.4" 24.65" 5.15" 34.0" 30.3" 4.45" 10.16" 15.8" TS123-5 2015.03.23

Technical Specifications Switch settings Factory setting Qv Δ P st Air volume Pressure Power consumption (rpm %) cfm "WC W ComfoAir 160 Cos Æ (-) 15 19 0.02 10 0,53 20 22.3 0.03 11 0,53 30 30.6 0.05 13 0,53 35 34.1 0.06 14 0,54 40 38.2 0.08 16 0,54 50 47.7 0.12 19 0,55 60 55.3 0.17 24 0,54 70 71.8 0.24 32 0,55 80 74.1 0.30 41 0,55 90 85.9 0.38 56 0,55 100 94.1 0.46 67 0,56 Pst Inch WC 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 15% 30% 40% 50% 60% 70% 80% 90% 100% 0 0 22.3 38.2 55.3 74.1 94.1 70.6 82.4 94.1 106 cfm TS123-6 2015.03.23

Ventilation Unit Sound, supply air Speed 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz db(a) 15 % 65,7 49,4 40,3 32,9 27,6 13,8 14,3 20,3 42 30 % 69,3 54,9 48,2 41,7 38,1 26,3 19,5 21 47 40 % 72 59,1 53,1 46 43,7 33,5 26,8 22,4 51 50 % 74,1 63,2 57 49,2 48,6 39,3 33,5 25,3 55 60 % 75,9 66,5 60,5 52,1 52,6 43,7 39,1 31,8 58 70 % 79,3 69,7 65 55,9 57,1 48,1 44,7 38,6 62 80 % 82,2 71,7 67,6 57,7 58,9 50,7 47,7 42,5 65 90 % 84,1 74,8 70,3 62 61,4 54,6 51,8 47,8 68 100 % 86,2 75,8 72 63,3 62,8 57,1 54,1 50,8 69 Sound, extract air Speed 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz db(a) 15 % 52 34,3 25,2 14,9 3,3 4,6 4,2 3,6 27 30 % 55,6 39,9 33 23,8 13,8 10,8 8,3 6,7 32 40 % 58,3 44,1 37,9 28,1 19,4 14,4 11,9 8,3 36 50 % 60,4 48,1 41,8 31,3 24,3 17,3 15,3 9,8 39 60 % 62,3 51,4 45,3 34,2 28,2 19,5 18,1 13,1 42 70 % 65,6 54,6 49,8 38 32,8 21,7 10,9 16,5 42 80 % 68,5 56,7 52,4 39,8 34,6 23 22,4 18,4 48 90 % 70,5 59,7 55,1 44,1 37 25 24,4 21,1 51 100 % 72,5 60,8 56,9 45,3 38,5 26,2 25,6 22,6 52 Sound, unit emission Speed 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz db(a) 15 % 37,9 30,0 24,7 19,5 11,0 9,2 15,9 23,7 25,8 30 % 40,0 32,9 30,7 26,9 18,1 13,4 16,2 23,7 29,0 40 % 42,5 35,7 32,6 28,2 22,8 18,3 17,4 23,7 30,9 50 % 42,1 38,7 34,2 30,8 27,5 23,0 20,2 23,9 33,6 60 % 42,0 40,1 38,1 33,8 32,0 27,2 24,2 24,6 37,1 70 % 44,6 42,2 42,6 36,3 35,8 31,4 25,6 26,7 40,8 80 % 44,8 46,5 43,3 40,7 38,2 34,8 31,9 28,2 43,6 90 % 47,3 45,5 46,9 45,7 39,6 37,8 35,3 32,7 46,8 100 % 47,7 46,7 47,2 47,2 41,3 40,1 37,6 35,2 48,5 TS123-7 2015.03.23