THE PREMIUM QUALITY LINE FROM

Similar documents
SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

2006 Delta T Corporation dba Big Ass Fan Company

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Commercial Gas Furnace Upflow

LUCCI AIRFUSION QUEST II CEILING FAN

Low Profile Unit Cooler

SECTION MORTUARY REFRIGERATORS

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Explosion-Proof Electric Unit Heaters

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

HEAVY DUTY STORAGE GAS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

foundation ventilation systems for moisture and termite control

MAC-120HE-01 Air-Cooled Chiller

The Ultimate Truck Stock Motor

Horizontal Jet Pumps 1/3-1-1/2 HP

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Ventilation Solutions Radon Mitigation

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

The space saving solution.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Portable Air Conditioner

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

CHESTER HOIST LISBON, OHIO, U.S.A PHONE (330) FAX (330)

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Using Portable Spot Air Conditioners in Industrial Applications

Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans

Operation and Installation Manual. Max Series

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SWIMMING POOL HEAT PUMP

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

ENHANCED LABORATORY HVAC SYSTEM

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Morgue refrigeration unit

SECTION AIR CONDITIONING UNIT

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

ARMSTRONG AIR HEAT PUMPS

Commercial Air is the smart choice for top air conditioning performance and the best value for money system around.

INFRARED RADIANT HEATERS. air heaters

, User s Manual

Light Duty Commercial Electric Water Heater

AerAtron. Ceiling fans

AIR CONDITIONING PRODUCTS COMPANY

Cooling Capacity CFM in. w.c. (125 Pa)

Cabinets 101: Configuring A Network Or Server Cabinet

Fan and Pad Greenhouse Evaporative Cooling Systems 1

Answers to Your Questions from the Webinar

Pool Dehumidification Basics

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Dock Hardware & Accessory Products Catalog

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Low Voltage Transformers Sealed, General Purpose, Dry Type

Cooktop Low-Profile Ventilation Hoods

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

Goulds Water Technology

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

N E R / E R T H R E E P H A S E ELECTRIC C H A I N H O I S T S

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Thermal destratification in buildings: The missing piece to the HVAC puzzle

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Scepter PVC Molded Junction Boxes

ASME Packaged Indirect Fired Water Heater

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

saving energy in comfort Factsheet Recair Enthalpy

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

plenum slot diffusers

Cooling Capacity CFM in. w.c. (125 Pa)

We will discuss common industrial applications with guides for the proper use of electric motors on these.

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

USER S MANUAL HSC-24A

Glossary of Heating, Ventilation and Air Conditioning Terms

Transcription:

THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION CEILING FANS EXCLUSIVE LOW CEILING S The only metal blade fans U.L. listed for mounting 7 blade height to floor. U.S. PATENT NUMBER 5,45,40 World Leader in Ceiling Fan Systems Visit our website at: www.marleymep.com

Only Leading Edge Offers These Exclusive Features. The most powerful motors in the industry providing maximum air velocity. The only fans in the industry with documented University tested area coverage. Secondary support cable is standard equipment on all models in compliance with, (CSA C.) The only line of commercial ceiling fans meeting the U.L. requirements for low ceiling applications. HEAVY DUTY Commercial Ceiling Fans Provides Superior Air Velocity and Efficiency, The Ideal School Classroom Fans (Models 4 and ). 0-/ Commercial Fan Designed for smaller areas, where minimal ventilation is required. Ideally suited for isolated areas and as a supplemental cooling fan. 40-/ 4 Commercial Fan Designed for commercial facilities such as school classrooms, offices, retail stores, restaurants. Provides maximum area coverage for both summer cooling and winter heat destratification. Suitable for low ceiling applications. U.L. 507 listed. Suitable for low ceiling applications. U.L. 507 listed. UL 507 states Ceiling Fans suspended from 7 feet to less than 0 feet (blade height to floor) must have minimum thickness of edge of blade / U.S. PATENT# 5,45,40 500-LC/ Commercial / School Classroom Fan Designed for spacious areas with low ceilings where larger blade diameter span creates maximum air velocity and area coverage at lower RPMs. Engineered specifically for continuous commercial use with the same manufacturing criteria as our heavy duty industrial line. Ideally suited for classrooms. 0 40 500LC BLADE DIA. 4 VOLT. MAX. CFM,500,000 AREA COVERAGE PER FAN 00 sq.ft. Note: Supplied with and 4 downrods. Effective amount of air volume moved past a plane 0ft. from fan. All specifications subject to change and improvement. Area coverage rated for heat destratification at 0 blade mounting height. Maximum continuous operation ambient temperature 05 F 0 lbs lbs NEW INDUSTRIAL REVERSIBLE FAN WITH EXCLUSIVE PATENTED HIGH PERFORMANCE DUAL PITCH BLADE. FInally a fan that provides the identical air flow volume, in either forward or reverse rotation. The dual pitch blade (Patented), is the only blade designed for maximum reverse direction air flow. Ideally suited for exhausting, condensation removal and prevention, reverse destratification and other draft free applications. U.S. PATENT# 5,575,4 For industrial applications with mounting heights of 0 or higher. Includes remote mounted reversing toggle switch suitable for up to fans. Switch requires four leads plus ground.

Aerodynamically contoured heavy-duty blade design provides maximum area coverage, will not warp in high temperatures. Perfectly balanced motor and blades for wobble-free performance. Thermal-overload protection, (Texas Instruments) built-in, self-resetting. Corrosion resistant, durable epoxy enamel paint finish over electrostatically applied powdered primer base. HEAVY DUTY/HIGH PERFORMANCE Industrial Ceiling Fans Reversible Fan 50-RDP Finally a fan that provides the identical air flow volume, in either forward or reverse rotation. The dual pitch blade (Patented), is the only blade designed for maximum reverse direction Ideally suited for exhausting, condensation removal and prevention, reverse destratification and other draft free applications For industrial applications with mounting heights of 0 or higher. U.S. PATENT# 5,575,4 Specialty Ceiling Fans Suitable for low ceiling applications. U.L. 507 listed. Suitable for low ceiling applications. U.L. 507 listed. -Speed Pull Chain For spot cooling in areas where wall switches are not desired. Also designed for production areas where single unit designation operation is required. 500 50 500 5007 000 00 50RDP* Maximum Area Coverage at Lowest Total Installed Cost. 500- / 50- / 500- / 500-7 / Industrial Fans Engineered and designed for spacious applications where maximum area coverage is required. Designed for both winter heat destratification and summertime cooling. Designed for general applications for above average area coverage and cooling velocity. Ideally suited for factories, gymnasiums, high bay storage facilities. Powerful, heavy-duty motor for mounting heights to 45 feet. 000- / 00- / 0 This is the world s most powerful ceiling fan. Its massive contoured blade design and high RPM efficiency creates the largest square foot area coverage and cooling effectiveness available. Capable of heat destratification to heights of 75 feet. BLADE DIA. 0 0 VOLT 0 77 MAX. CFM,000,000 4,000 4,000 7,000 AREA COVERAGE PER FAN Brown Brown 0 lbs 0 lbs Note: Supplied with 4 downrods. Effective amount of air volume moved past a plane 0ft. from fan, industry test. All specifications subject to change and improvement. Area coverage rated for heat destratification at 0 blade mounting height. Maximum continuous operation ambient temperature 05 F *Reversible fan includes remote mounted toggle switch suitable for up to fans. Switch requires pulling 4 wires (not including ground) from fan to switch. 50- / 00- Harsh Environment Ceiling Fans Designed and engineered specifically for food processing plants, wet factory locations, exposed shipping areas, outdoor restaurants, agricultural applications such as poultry houses and greenhouses. BLADE MAX. AREA COVERAGE DIA. VOLT. CFM PER FAN HARSH ENVIRONMENT S 50 00 Note: Supplied with finished downrods. BLADE MAX. AREA COVERAGE DIA. VOLT CFM PER FAN -SPEED PULL CHAIN S 40* 500* 0 4 4,000 *-Speed Pull Chain BLADE MAX. DIA. VOLT. CFM THEATER FAN S 40B 500B 4,000,000 AREA COVERAGE PER FAN Black Black 0 lbs lbs lbs lbs YEAR WARRANTY REGISTRATION AGAINST MANUFACTURERS DEFECTS IS INCLUDED WITH EACH FAN. Effective amount of air volume moved past a plane 0ft. from fan, industry test. All specifications subject to change and improvement. Area coverage rated for heat destratification at 0 blade mounting height. Maximum continuous operation ambient temperature 05 F

Only Leading Edge provides university documented performance data. Compare this exclusive data to any other fan available. AREA COVERAGE SUMMARY BY FAN BY HEIGHT COMMERCIAL S 0 500 000 500 000 500 000 500 4000 4500 5000 0/ V 40/ 4 V 500/500LC/50/ V 0/ V 40/ 4 V 500/500LC/50/ V 0/ V 40/ 4 V 500/500LC/50/ V 7 0 0 MOUNTING HEIGHTS INDUSTRIAL & SPECIAL APPLICATION S TOTAL SQUARE FOOT AREA COVERAGE 500/50RDP/ V 500/5007/ 0/77V 000/00/ 0 V 500/50RDP/ V 500/5007/ 0/77V 000/00/ 0 V 500/50RDP/ V 500/5007/ 0/77V 000/00/ 0 V 500/50RDP/ V 500/5007/ 0/77V 000/00/ 0 V 0 0 40 45 MOUNTING HEIGHTS 5000 4500 4000 500 000 500 000 500 000 500 0 HEAVY DUTY COMMERCIAL S TOTAL AREA COVERAGE TABLE IN SQUARE FEET 500LC BLADE HEIGHT 40 500 500 500 000 FROM FLOOR 0 40 50 50RDP 5007 00 45 - - - 5 Ft. 900 Ft. 5 x 5 54 x 54 40 - - - 00 Ft. 00Ft. 4 x 4 0 x 0 0 - - - 05 Ft. 4000 Ft. 55 x 55 x 0 00 Ft. 05 Ft. 05 Ft. 00 Ft. 5000 Ft. 40 x 40 45 X 45 55 X 55 X 7 X 7 0 5 FT. 00 FT. 00 FT. - - 5 X 5 40 X 40 4 X 4 7 900 FT. 5 FT. 00 FT. - - 0 X 0 5 X 5 40 X 40 NOTE: Above area coverage calculations are for heat destratification. 4

DUAL PURPOSE ENERGY CONSERVATION SYSTEM ENTRAINMENT (CENTERLINE) THE HEAT-DROPPER CONCEPT AND HOW IT WORKS WINTER-Recovers wasted heat by eliminating heat stratification. Trapped warm air at the ceiling caused by natural heat rise and poor air circulation is equalized by the movement of the massive blade span. Thus ceiling to floor temperature is equalized. With a heat cost savings of 0k percent, the LEADING EDGE fan system can pay for itself in one year. The elimination of cold spots increases employee productivity and comfort. SUMMER-General air recirculation in non airconditioned buildings creates a cooling breeze and a Wind Chill Factor providing evaporation cooling of the skin surface dropping shin temperature by degrees. The LEADING EDGE fan system supplements air-conditioned buildings by allowing the thermostat settings to be degrees higher. You ll feel the coolness of 7 degrees with the thermostat set on 0 degrees - an incomparable energy savings. Additional advantages, eliminates mold and mildew caused by stagnant air, perfect for high humidity areas. No other fan has our higher air velocity capabilities. Small fans do not develop sufficient CFM to be effective in warm weather. Call or write for a FREE copy of our Technical Guide which includes information such as: Air Velocity Flow Charts Ceiling Fan Air Patterns Estimating Annual Savings For Heat Recovery Blade And Motor Designs Capital Cost Comparisons Fan Placement Calculations Wiring Information 5

Compare these Exclusive Features! SECONDARY SUPPORT CABLE Now Standard Equipment on all models. This new Secondary Support cable complies with existing CSA (Canadian Standards Association) requirements and all other proposed safety regulations for overhead air movement equipment. EXCLUSIVE SHAFT CONNECTION By attaching directly from the beam to the permanent motor shaft this Secondary Support cable protects against any possible failure or improper installation of the fan J hook, upper yoke assembly, rod, lower yoke assembly and related hardware. SPECIFICATION FEATURES: Pre-Installed directly to permanent shaft for maximum protection and easy installation. length of heavy-duty 7x7 / galvanized cable. Rated breaking strength of 700 lbs. Galvanized U-bolt wire clips () included for attachment to beam structure for extra strength and security. CSA (Canadian Standards Association) listed (Standard C. Sept. 9) OPTIONAL MOTOR SPEED Only Leading Edge motor speed controls are custom engineered, manufactured and U.L. listed to all Leading Edge Fans. For single and multiple fan installations. Dial-on/off switch allows high-to-low variable speed control above factory-set anti-stall level of 50 VAC. Available in,, Amp Models, /0/77 Volt Amps Amps Amps Models: 0 00 770 Models: 0 00 770 Models: 0 77 Model: 0N For Single Fan Model: 05N For Two Fans Models: 0N 05N IMPACT RESISTANT CEILING FAN GUARDS EXTRA HEAVY-DUTY, TOTALLY ENCLOSED IMPACT RESISTANT CEILING FAN GUARD FOR SCHOOL GYMNASIUMS, INDOOR AREAS, PUBLIC ARENAS, ETC. 00 00 9FP04 9DBW 9DBW 9DBW 9D4BW 9999 ITEM FAN GUARD DIAMETER FOR INDUSTRIAL AND 0 FANS FAN GUARD 5 DIAMETER FOR COMMERCIAL AND 4 FAN ONLY WHITE TILTED CANOPY COVER - BROWN( 9FP0), BLACK( 9FP0B) DOWNRODS - DOWNRODS - Also available in brown, replace W in model DOWNRODS - }number with B Ex. 9DBB DOWNRODS - 4 (FOR LONGER SIZES - CONSULT FACTORY) OUTDOOR LOCATION INSTALLATION KIT* 50 40 4 Custom models available. Consult with factory for information and specifications. Use only with heavy-duty / industrial models - Not recommended for low ceiling applications. Fan Guards ship via UPS *Only for use with harsh environment fans.

COMMERCIAL, INDUSTRIAL AND EXTRA HEAVY DUTY AIR CIRCULATORS Now Available Available in, 0, 4, 0 and. 5 models oscillating and non-oscillating available for Pedestal Mount, Wall, Ceiling, or I-Beam Mount applications. Available in all world voltages, 0 and 77 volts. Call for our new page catalog. NOTE: All measurements are calculated from ceiling or beam line with J hook mounted securely in center of -/ deep conduit box and downrod supplied on rubber roller (See illustration). CEILING FAN DIMENSIONS* S SUPPLIED WITH 4 DOWNROD SERIES A B C D 0 -/ 9 0-/ 40 4 -/ 9 0-/ 40 4 5-/ 9 0-/ 500LC -/ 9 0-/ 500 5-/ 9 0-/ 50RDP -/ 9 0-/ 500** -/ 9 0-/ 000 0 4 9 0-/4 S SUPPLIED WITH DOWNROD 50 -/4 5-/ -/ 00 0 5-/4 -/ * Allow for / variance in J hook depth. ** Identical measurements for 0 volt and 77 volt models. Note for models supplied with shorter downrod subtract from measurements scale C. SUGGESTED CEILING FAN SPECIFICATIONS Ceiling fans to be furnished as specified, Leading Edge, Inc. Fans to be U.L. listed Standard 507 with matching U.L. listed solid state controls. All motors to be direct-drive permanent split capacitor type, with permanently sealed ball bearings. All motors to have built-in, selfresetting (internal) thermal overload protector model TI9700, Fan Model, Blade Diameter (sweep), Primary Voltage, motor to be totally enclosed, Full Speed Watts to be, RPM to be, CFM to be and Area Coverage Per Fan to be Sq. Ft. Performance shall be certified by AMCA, an independent laboratory or a University Engineering department with documented testing. All fans to have factory installed Secondary Support Cable Assembly connected to motor shaft, with minimum feet galvanized cable / 7x7 with rated breaking strength of 700 lbs and must comply with CSA std. C. Sept, 9. Fan blades to be straight with contoured shaped design for maximum efficiency. Note: Fans installed with blade height less than 0 from floor must have rolled edge blades minimum / thick in compliance with U.L. 507. Fans to be labeled in accordance with U.L. 507 Mounted blade height to floor of 7 feet acceptable. Fans used with motor speed controls must be labeled in accordance with U.L. 507 Suitable for use with solid state motor speed controls. Factory supplied accessories to include: A) Solid state motor speed controls (U.L. listed) B) Special length downrods C) Totally enclosed impact resistant fan guard D) Tilted canopy cover E) Outdoor location installation kit 7

NUMBER 0 40 500LC CPF5 5HRCF NUMBER 00 00 9FP04 9DBW 9DBW 9DBW 9D4BW 9999 ACCESSORIES & MISCELLANEOUS ITEMS Use only with heavy-duty industrial models Fan Guards ship via UPS Custom models available. Consult with factory for information and specifications. NUMBER 0 0 0 00 00 0 BLADE SWEEP 4 40B 4 40* 4 500B 500* 50-RDP** 50 00 VOLTS 0 0 0 FAN S AND ACCESSORIES SUMMARY HEAVY DUTY COMMERCIAL S VOLTS *-Speed Pull Chain **Reversible, includes toggle switch ***Requires installation kit for outdoor locations 500 50 00 5007 000 00 0 0 0 BLACK BLACK BRN BRN 0 77 ITEM OPTIONAL SOLID STATE MOTOR SPEED AMPS FULL LOAD CYCLE AMPS.5.5.0.0 0. / 0 7 0 FULL LOAD WATTS 75 0 0 9 4 / 40 5 0 RPM 95 5 5 5 0 SPECIAL APPLICATION S /0.5.5.0.0.0 0 0 0 5 5 75 5 75 HARSH ENVIRONMENT S***.0 0 5.4 0 0 MAX CFM,500,000 4,000 9,00,000,000 4,000 HEAVY DUTY INDUSTRIAL S.0.0.5.0.4.4 0 0 0 0 0 0 75 75 0 0 5 5,000,000 4,000 4,000 FAN GUARD DIAMETER FOR INDUSTRIAL AND 0 FANS FAN GUARD 5 DIAMETER FOR COMMERCIAL AND 4 FAN ONLY WHITE TILTED CANOPY } COVER - BROWN( 9FP0), BLACK( 9FP0B) DOWNRODS - DOWNRODS - DOWNRODS - number with B Ex. 9DBB DOWNRODS - 4 (FOR LONGER SIZES - CONSULT FACTORY) OUTDOOR LOCATION INSTALLATION KIT* Also available in brown, replace W in model / 500 500LC 50RDP 50 5 0 AREA COVER- AGE PER FAN 00 sq.ft. 0/77 500 5007 WEIGHT 50 40 4 WEIGHT 0 lbs lbs lbs lbs lbs 0 lbs 0 lbs 0 lbs 0 / 000 00 4 770 77 77 77 0N 05N NOISELESS MECHANICAL CONTROL 5 YEAR WARRANTY REGISTRATION AGAINST MANUFACTURERS DEFECTS IS INCLUDED WITH EACH FAN. Effective amount of air volume moved past a plane 0ft. from fan, industry test. All specifications subject to change and improvement. Area coverage rated for heat destratification at 0 blade mounting height. For use with 4 and models only. DISTRIBUTED BY: 470 Beauty Spot Rd. East Bennettsville, SC 95 USA www.marleymep.com -00-4-HEAT ZBL-LECFA