Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans
|
|
|
- Vivien Sherilyn Armstrong
- 9 years ago
- Views:
Transcription
1 Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans Version 9.0 April
2 Delivery: Upon receipt of fans, thoroughly inspect units for any damage sustained during transit. If damaged, contact Pacific HVAC Engineering or your supplying distributor immediately. Site Storage: If the fan is not installed immediately, it should be stored in a clean, dry and preferably warm environment. Safety: Rotating fan impellers and electric motors can be dangerous to personnel; only experienced qualified persons should carry out work on these products. The following precautions must be taken: Electrically isolate the fan motor prior to undertaking any work. Check that all fasteners, particularly impeller fasteners, are tight prior to start up. Do not re-use locking fasteners. Electrical Supply: Check that suitable supply is available. 415V, Three Phase, 50Hz. Motor Electrical Information All electrical installation shall comply with AS/NZS 3000:2000. MacroAir fans use a 0.94kW Electronically Commutated Motor. There are no special requirements for wiring 3 phase power to the unit, and Neutral is not required. For control wiring use data cable when using the 1 fan controller and when using a MODBUS system use a MODBUS/PROFIBUS cable to add the fans to the network. Check the shipment against the list below and ensure that all components are available before beginning the installation. Fan Components 1) Fan Blade Box a. 6 x MACROAIR Blades 2) Mounting Hardware Kit a. 1 x Cover Plate b. 1 x Keyless Bush c. 1 x Pivot d. 2 x Clamp Plates e. 2 x Spacer Plates f. 6 x Safety Links g. 6 x Link Extensions h. 1 x 6mm Safety Cable i. 4 x 3mm Guy Wire Cables j. 1 x Mounting Hardware Bolt Kit k. 1 x Blade Bolt Kit l. 1 x Hub Assembly Bolt Kit m. 1 x Quick Start Guide 3) Power Unit Box a. 1 x Frame b. 1 x Gear Motor 4) Hybrid Hub Box a. 1 x Hybrid Hub 5) Fan Controller (Where Applicable) a. 1 x MacroAir Controller 6) Extension Tube (Where Applicable) 2
3 Guidelines for Positioning Fans Check the installation area to determine clearances around the fan. The optimal mounting height is times the diameter of the fan (fans can be mounted up to 15m above ground level). Mounting Requirements 1) The blades of the fan must be at least 3m above floor level 2) The blades must be at least 0.6m away from vertical and horizontal features 3) The blades must be at least 1.5m away from the edge of a mezzanine floor if less than 3m above the floor level. 4) Roof / Ceiling clearance must greater than 15% of the fan diameter ( as an average if the roof is sloping part of the fan can be closer) 5) The fan must mounted between and preferably above lighting fixtures to prevent shadow strobing. 6) Smoke Detectors shall be mounted at least 1m outside the sweep of the fan blades 7) The hub of the fan shall be at least 1.5m from sprinkler heads, blades shall be at least 0.9m from sprinkler heads 8) Any local regulatory and legislative and insurance guidelines must be adhered to. 9) The fan must be attached to a primary building structure that is rated for the weight of the fan unit. Typically, I beams are the preferred support structure. Advice should be sought from Pacific HVAC Engineering or a suitably qualified structural engineer for installations to non primary structural elements. 3
4 Assemble the motor hub 1. Take the nuts from the safety plate, and then line up the bolts of the safety plate with the corresponding holes on the frame of the power unit. Reattach the nuts and tighten securely to 20N.m using 5/8 spanners or sockets. 2. Inset the first part of the keyless bush into the hole in the aluminium hub. 3. Push the keyless bush over the shaft of the gearmotor and into the centre hole on the hybrid hub, lining up the 4 holes in the keyless bush and the hub 4. Using the 4 gold coloured bolts and spring washers in the hub assembly bolt kit, tighten the keyless bush onto the shaft, tightening to 24Nm in a star pattern with a 7/16 socket and use a thread locking compound on the thread. Ensure that the ring plate on the hybrid hub is moving clear of the safety plate to ensure the operation of the fan is not impeded. 5. Screw the cover plate over the keyless bush and shaft assembly. 4
5 Install the Fan 1) Attach the pivot assembly to the roof structure. Mount the large plate of the pivot against the underside of the beam. Ensure that the long axis of the plate is at 90 o to the axis of the beam. Place the clamp plates on top of the beam flange and bolt them to the mount with 4 of M12 x Grade bolts and locknuts. For thicker I beams, use the supplied spacer plates between the pivot and the clamps. 2) Attach the optional extension Bolt the extension tube to the pivot using 4 of M12 x Grade Bolts and Locknuts 3) Attach the motor hub to the pivot or extension Attach the motor hub to the pivot or optional extension tube with 4 of M12 x Grade Bolts and Locknuts with the hybrid hub on the downward side. 4) Remove and discard black rubber transportation tube from gear box breather valve. 5) Attach the safety cable Loop the 6mm steel safety cable around the beam and through the frame of the power unit and clamp with the supplied cable clamps. The installation of the safety cable is mandatory, and no warranty will be issued for fans without the safety cable. 6) Complete the electrical installation of the fan motor. 5
6 7) Attach the guy wires Guy wires should be mounted at an angle of approx. 45 o in the vertical plane and at 90 o from each other. Place the turnbuckle ends of the cables on the loops provided on the power unit frame and make taut, ensuring that the fan frame remains vertical. The installation of the guy wires is mandatory and no warranty will be issued for fans without guy wires. 8) Attach the blades a. Ensure the blades are correctly orientated. They are an airfoil design, and the thick edge is the leading edge. The underside is the concave side. b. Slide the blade over the stub on the hybrid hub, aligning the channel in the blade with the stub. c. Put a bolt in the outer hole to locate the blade d. Place the safety links over the top side of the inner hole and put a bolt through the safety links and inner hole. The safety links and safety link extensions are mandatory and no warranty will be issued for fans without safety links and extensions. e. Place the safety link extension over the bolts protruding on the underside of the blade and bolt the blade assembly to the hub. f. Repeat for all blades and tighten all bolts (Note: do not tighten bolts until all blades are fitted). 6
7 9) Install Control Unit and Wire to Fan Motor WARNING: Ensure 415V power supply to the fan motor is disconnected before installing the control unit. The user Control Unit (On/Off Man/Auto Speed Control) should be installed remotely from the fan unit so as to provide easy access. Position the Control Unit within direct line of sight to the MacroAir fan. Ensure the controller is easily visible and located in a position protected from physical damage, direct sunlight and moisture. MacroAir fans can be controlled by an analogue 0-10V signal or via MODBUS. When operating as a MODBUS system use appropriate data cable and wire to the RSA/RSB terminals on each fan. When using the MacroAir controller, wire as per Fig.1 below with appropriate data cable. It is required that 6 terminals are to be wired to ground level to facilitate any future programming changes. Motor Control Junction Box Orange Blue Brown Red Black Yellow RSA RSB +10V 0-10V Analogue Input GND +20V +10V 0-10V Analogue Input GND +20V Y R B Macroair Controller MODBUS Control Optional Temperature Sensor Fig. 1 7
8 The following guidelines apply in setting up MacroAir to be controlled via an external MODBUS controller The motors used in the MacroAir fans are designed to accept MODBUS RTU over RS485 serial line. Default settings for MODBUS communication with MacroAir fans are a baud rate of 19,200 bit/sec, even parity configuration and 1 stop bit. Wiring shall be completed according to local standards, taking into account the details provided in the operating instructions. Figure 2 below is provided as reference for connecting the MacroAir fans into a MODBUS control system. Addressing the Fans Figure 2 Suggested wiring for MODBUS control system To have a fully functioning MODBUS system, each MODBUS device must have a unique address on the MODBUS system. You will be required to change the address of each MacroAir fan installed on site, as each fan will leave the factory with default address of 1. The address of the fan can be checked and changed using holding register D100. See section 2.9 of the MODBUS protocol supplied with the MacroAir for details of accepted values. 8
9 Setting up the Fans Since each size of MacroAir fan has its own specific operating details, there are a number of changes that will need to be made using connection through the external controller. Parameter Register (Register Type) Required Input Protocol Reference Section Source Set Value D101 (holding) RS Operating Mode D106 (holding) Closed Loop Speed Control 2.16 Maximal Speed D119 (holding) See Table 2 for maximum speed by fan diameter Ramp-up Curve D11F (holding) 90 seconds Reset D000 (holding) Reset must be used to apply parameter changes and reset errors 2.2 Table 1 Initial Set-up Parameters Impeller Diameter Maximum Motor rpm Impeller Diameter Maximum Motor rpm Operation of the Fans 2.4m 8ft m 16ft m 10ft ft m 12ft m 20ft m 14ft m 24ft 1230 Table 2 Maximum Speeds for MacroAir fans by Diameter Fan speed is determined by the value in the Default Set Value, holding register D001. This will only have effect provided Source Set Value (D101) has been changed to accept RS485. To start the fan, enter a value that is defined in part (a) of section 2.3 in the MODBUS protocol. The value entered will be a function of the required speed and the maximum speeds shown in Table 2. To stop the fan, a value of 0 should be entered into the register. Input register D011 (motor status) can be used to read errors that may be present in the system. See section 3.9 of the MODBUS protocol for a list of errors that can be found. Input register D012 (warning) can be used to read warnings that may be present in the system. See section 3.10 of the MODBUS protocol for a list of warnings that can be found. Input register D000 is used to reset errors and apply parameter changes. Inputting a value of 2 is required to apply parameter changes, but it will not reset failures. Inputting a value of 4 into this register resets failures only. Inputting a value of 6 into this register will both apply parameter changes and reset failures. 9
10 10) Commission the Installation WARNING: Ensure 415V power supply to the fan motor is disconnected before commencing commissioning. a. Check that all mechanical connections including safety cables and guy wires have been installed according to this guide. b. Ensure there are no physical obstructions that could be impacted by the rotating blades of the fan unit. c. Ensure all bystanders are cleared from the area during commissioning. d. Set Controller Unit to the Off position. e. Connect 415V supply to the fan motor. f. Switch the Controller Unit to MAN (Manual) operation. g. Set FAN SPEED on the Controller Unit to position 2. h. Switch the Controller Unit to the ON position. The fan motor is designed to ramp up to speed over a 90 second period. i. Once the fan achieves constant speed, increase the Control Unit FAN SPEED to test higher air movement velocities. j. Observe the operation of the fan to ensure there are no faults including mechanical noises and vibration. k. If the fan unit vibrates / oscillates as though out of balance or if there is any mechanical noise present, shut the fan down by switching the Control Unit to the OFF position before investigating further. Care and Maintenance Instructions The following maintenance instructions must be followed annually to ensure the safe operation of the fan. Attendance to maintenance requirements must be logged in a plant maintenance log book. Failure to follow these maintenance requirements voids the product warranty. WARNING: Turn off the fan and lock out power supply before performing maintenance. WARNING: When cleaning or attempting to re-torque you must unplug or disconnect the fan and controller from the power supply. Fan Hub and Blades: Dirt and dust may be removed from the blades by using a cloth or soft non-metallic brush. Stubborn stains may be removed with a cloth dampened with a mild detergent solution. Do not use strong solvents, Check the fan, including mount supports for bolts and nuts to make sure they are tight and show no wear and tear. Re-torque fasteners if required Check for oil leaks. Inspect 7mm lugs inside motor junction box and tighten if necessary. Using compressed air at 90~100 psi, blow all dust and debris off of the outside of the motor housing. Fan Controller: The fan controller should only require a wipe to remove dust and dirt. For heavier deposits, use a rag and a mild cleaning agent to clean the exterior of the control controller box. 10
11 Operating Instructions Fans operate in both summer cooling and as winter destratification modes. In summer cooling mode the fans operate by generating a cooling breeze of m s -1. This allows the body s natural cooling mechanisms to work more effectively, resulting in an apparent reduction in temperature of 4-6 o C. The fans do not affect the actual temperature of the air. There is a correlation between air velocity and apparent reduction in temperature until approx. 3m s -1 where the effect levels off and reduces. This means that the generation of a gentle breeze is more effective than creating higher velocity, and more focused air streams. In winter destratification mode the fans operate by mixing the warmer air that has collected at the top of a structure with the cold air below, increasing the ambient temperature of the space. This is achieved by running the fans at their minimum speed so that a nuisance breeze (wind chill) is not created. As the fans are operated with speed control, it is more efficient to run them slowly in a forward direction than to reverse the direction of the fan and keep the rotational velocity of the fan high. Operating Instructions 1) Choose control. If a temperature sensor has been fitted as part of the installation turn the MAN/AUTO switch to AUTO. If there is no temperature sensor set to MAN If set to MAN the fan speed is controlled by the potentiometer. Turn clockwise to increase the speed of the fan. 2) Turn the OFF/ON switch to ON The fan is designed with a 90 second ramp time. If the fan fails to start after 90 seconds turn off power and retry. 11
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Australian edition 2011 Instructions...3 General precautions...3 Location and installation requirements for your fan...3
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español
For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation
1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.
Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the
Original Assembly Guide
TCT Multipurpose Single Bevel Sliding Compound Mitre Saw Original Assembly Guide Read instructions before assembling this tool. Table of Contents GB Assembly Guide Read instructions before assembling this
Drive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide
BBWX1 Satellite Weather Receiver Installation and Maintenance Guide Rev FUSA 15JUL2007 Table of Contents Safety Precautions 3 Disclaimer. 3 Contents of Package. 4 Tools Required..4 Installation General
60" TulleTM. Instruction Manual. A Kichler Select ceiling fan
60" TulleTM A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday
INSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)
INSTALLATION INSTRUCTIONS 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) Thank you for purchasing a quality Hellwig Product. PLEASE
Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks
TITAN pt. no.: 03 0000 0120 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
HG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
INSTALLATION INSTRUCTIONS. 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD IMPORTANT NOTES
INSTALLATION INSTRUCTIONS 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS
M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS (SPLIT IDLER) 1 # TABLE OF CONTENTS List of parts and tools................................................3 Installation of complete kit...................................................5
Remote Head REMO ONE. Code 5750. Manual
Remote Head REMO ONE Code 5750 Manual by sachtler. All rights reserved Version: 1.2/09/05 Issue date: September 2005 Order no.: srh20t010a We want you to receive Sachtler products that are always state
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. 2 0 0 5 D U K E A I R X C / S L / R A C E S E R V I C E G U I D E Information
Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual
Range Road RR Series Semi-Automatic Firewood Processor Crated Unit Assembly Manual 1 1) Undo 8-18mm x 19mm Nuts and bolts, 2 on each leg of top frame 2) Lift top of Metal crate off and move out of work
Triac Printed Circuit Board Replacement
Technical Service Bulletin: Triac Printed Circuit Board Replacement TRONIC 5000C Pro Models: WH17, WH27, WH36 Introduction Fig. 1 ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND ENSURE ALL
Rebuild Instructions for 70001 and 70010 Transmission
Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
Operating Instructions
Operating Instructions Series L 000 Cord Reels Model Numbers: L 000 L 0 0 L 0 B L 0 X L 00 L A X L 0 L 0 0 L 00 L 0 L 0 B L 0 0 X L 00 L 0 A L 0 X IMPORTANT Read this manual carefully before installing,
CortezTM A Kichler Décor Ceiling Fan
CortezTM A Kichler Décor Ceiling Fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction
MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions
06/2011 MBSAW Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper
Structural Holding System
Structural Holding System Users Manual November 2013 by Vehicle Service Group. All rights reserved. CO8812.1 502071 Rev. - 11/21/2013 CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies
INSTALLATION MANUAL. Installation Instructions
INSTALLATION MANUAL Power-Pole Signature Series Shallow Water Anchor Installation Instructions CAUTION: Read this instruction manual carefully. Become familiar with the controls and know how to operate
Auto Sentry-eXP Maintenance
Auto Sentry-eXP Maintenance Maintenance Procedures for Auto Sentry exp Bill Dispenser Credit Card Reader Bill Acceptor Bill Dispenser Maintenance Bill Dispenser Problem / Cause Bill Dispenser Error Codes
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
Awning Instructions. Full Cassette 1.5m to 6m
Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -
Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.
ASSEMBLY 1 - EPS V2 POWER UNIT (SOLUTION 5) 1.1 - POSITIONING INSIDE THE SEAT TUBE WITH ELASTIC SUPPORT IN THE SEAT BRACKET TUBE Depending on which elastic support you have you can secure the V2 power
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
AE.MA.ASU.PL.008 Issue 02 Page 2 of 20 INTENTIONALLY BLANK
Page 2 of 20 INTENTIONALLY BLANK Page 3 of 20 CONTENTS CONTENTS...3 1. INTRODUCTION...5 2. APPLICABLE DOCUMENTS...5 3. OPERATION...6 3.1 General Description...6 3.2 Physical Data...6 3.3 Electrical Bonding...6
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET
Be sure to read this installation manual thoroughly prior to installation. If installation methods or non-standard parts not specified in this installation manual are used, accidents or injury may result.
Resharpening Companion
Resharpening Companion 10950 Correct Angles, Pictures, and Step-By-Step Instructions The Resharpening Companion is meant to be a guide and quick reference to help you resharpen. It is not meant to replace
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
Quick start guide smart.power smart.power smart.power
Quick start guide Intended use: smart.power is a universal charging device for charging (in absence of other charging options) your mobile phone, your TEASI-navigation system or other devices with a 5V
Connecting the Channel A
20 Edge Lighting. All Rights Reserved. Installation Instructions for Cirrus Channel Suspension T, Tubular Lens w/2sq or 2RD Canopy IMPORTANT INFORMATION - This product is suitable for indoor locations.
Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd. http://www.hikvision.com
Bullet Camera Installation Guide Hangzhou Hikvision Digital Technology Co., Ltd. http://www.hikvision.com 1 Thank you for purchasing our product. If there are any questions, or requests, please do not
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
MUSTANG II IFS COMPLETE PARTS PACKAGE
MUSTANG II IFS COMPLETE PARTS PACKAGE Your Southern Rods & Parts Mustang II IFS Parts Package contains the following items: 1 pr) Upper Control Arms (2023) 1) Upper Arm Bolt Kit (MP-001-A) 1 pr) Lower
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than
Parts#MB003-003 Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)
Installation Instructions Reverse Gear MAMBA (Monoblock for Cable operated) Read and become familiar with these installation instructions before start. Two Piece for H-D 5 Speed Trans., Cable operated
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject to change at anytime
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-54 Case IH CVX 1135 CVX 1145 CVX 1155 CVX 1170 CVX 1190 CVX 1195 CVX 135 CVX 145 CVX 155 CVX 175 CVX 195 New Holland TVT
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Front axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &
M O U N T I N G I N S T R U C T I O N S instructions This document is protected by copyright. The SICK AG company retains this right. Reproducing this document in whole or part is only permissible within
Competition 4 & 6 suspension Lift Toyota Landcruiser & nissan patrol
Competition 4 & 6 suspension Lift Toyota Landcruiser & nissan patrol Competition suspension Product Guidelines Guidelines for sale and recommendation of 4 (100mm) and 6 (150mm) Lifts for Toyota Landcruiser
2006 JUDY SERVICE GUIDE
2006 JUDY SERVICE GUIDE For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject
Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales
Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A
PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510
GPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual
STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER
14 14 STEERING HANDLEBAR/FRONT WHEEL/ SCHEMATIC DRAWING ------------------------------------------------- 14-1 SERVICE INFORMATION------------------------------------------------ 14-2 TROUBLESHOOTING-----------------------------------------------------
Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear
Section Brake Drum 6 Failure Analysis WARNING To prevent serious eye injury, always wear safe eye protection when you perform vehicle maintenance or service. Figure 6.1 ASBESTOS AND NON-ASBESTOS FIBERS
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
ASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS
ASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS BELT DRIVE ASSEMBLIES Part# 58-850 2 Old School Belt Drive Assembly - Polished Part# 58-851 2 Old School Belt Drive
Multi-Pitch Pitching Machine USER MANUAL
Multi-Pitch Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Multi-Pitch Pitching Machine. The Cimarron Multi-Pitch Pitching Machine is a high performance pitching machine
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
ALLDATA Online - 2006 Dodge Truck RAM 2500 Truck 2WD L6-5.9L DSL Turbo VI... Service and Repair
Page 1 of 15 Home Account Contact ALLDATA Log Out Help PAUL REDEHOFT Select Vehicle New TSBs Technician's Reference Component Search: OK 2006 Dodge Truck RAM 2500 Truck 2WD L6-5.9L DSL Turbo VIN C Conversion
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
758 Heavy-duty Ratchet Guy Wire Cutter
INSTRUCTION MANUAL 758 Heavy-duty Ratchet Guy Wire Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Solar Panels 2 Watt Solar Panel: SP101 5 Watt Solar Panel: SP102 01-752
AXLE SHAFTS - FRONT. 1998 Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION
AXLE SHAFTS - FRONT 1998 Pontiac Bonneville 1998-99 DRIVE AXLES FWD Axle Shafts - Cars - "C", "G" & "H" Bodies GM Aurora, Bonneville, Eighty Eight, LeSabre, LSS, Park Avenue, Regency, Riviera MODEL IDENTIFICATION
6 inch A-Arm Lift Kit WARNING: 16-018/16-019. installation instructions. will fit CLUB CAR DS. included:
Revised May 205 6-08/6-09 6 inch A-Arm Lift Kit will fit CLUB CAR DS installation instructions included: Rear Lift Blocks Main Suspension Assembly Spindles A-Arms Rear Shock Mounting Plates U-Bolts WARNING:
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
INSTRUCTION MANUAL (WINDOW WIPER)
INSTRUCTION MANUAL (WINDOW WIPER) SUBJECT CONTENTS PAGE 1. GENERAL 2 2. CONTRUCTION 2 2-1. STRAIGHT LINE TYPE WINDOW WIPER 2 2-2. CONTROL BOX 2 2-3. SPARE PARTS 2 3. MECHANISM AND OPERATION 2 3-1. STRAIGHT
Wind Direction Smart Sensor (S-WDA-M003)
(S-WDA-M003) The Wind Direction smart sensor is designed to work with HOBO Stations. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station. All sensor parameters
BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide
BUGGY SETUP GUIDE Volume 1 GOKARTSUSA GY6 150, CN250 Buggy Setup Guide GY6 150, CN250 DUNE BUGGY Buggy Setup Guide GOKARTSUSA.COM 2000 Highway 50 S. Lake Tahoe, CA 96150 Phone 800.603.1437 2 Table of Contents
Awning Instructions. Standard Manual 1.5m to 4.5m
Awning Instructions Standard Manual 1.5m to 4.5m English Standard Manual Instructions Contents Warning 1.5m 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830
Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
Cooling system components, servicing
19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap
2011-14 F250 6 RADIUS ARM KIT
92154000 Thank you for choosing Rough Country for your suspension needs. 2011-14 F250 6 RADIUS ARM KIT Rough Country recommends a certified technician installs this system. In addition to these instructions,
Model No: VS4815 1. SAFETY INSTRUCTIONS VS4800 2. INTRODUCTION & APPLICATIONS VS4815 3. CONTENTS. 2.1 Introduction. 2.
Instructions for: Petrol Engine Twin Camshaft Setting / Locking Tool Kit - (incorporating Vanos Alignment) - BMW N42 & N46 Engines Model No: VS4800 Associated kit: Camshaft/Carrier Bracket Remover & Installer
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit Product description BGAN fixed mount kit Although the BGAN satellite modem terminal is designed for portable use, the BGAN Fixed Mount