FEATURES & SPECIFICATIONS INTENDED USE RDI 1x4 ft. smooth and uniform ambient lighting for all commercial and industrial environment. SIZE W x L x H in inches (mm) 11.56W x 48.0L x 5.5Dp (600 x 1220 x 140) LAMP 1, 2 lamp positions. MOUNTING Recessed inverted T-Bar ceilings. Grid mount. MATERIALS & FEATURES Housing is die-formed and embossed code 22 gage steel. Luminaire diffuser snaps into place; no tools are required for removal. Diffuser is perforated to maintain even brightness, and provided with an internal, acrylic overlay to obscure lamps. Direct / indirect mimics sky light appearance Recessed perforated center diffuser with acrylic overlay. - LISTING Fixture and Ballast: UL Listed. Ballast: Thermally protected, class P, HPF, Non PCB. TYPICAL OPTIONS AND ACCESSORIES Emergency ballasts, whips, and lenses. See options page at the end of the T02Grid section, or contact factory for more details. ORDERING INFORMATION Example: RDIRL12812PMV RDI RL 1 28 12 PMV Series Lamp Type [1] Ballast & Voltage [1] RDI Direct/Indirect, Center basket, Grid mount Lamp Positions 1, 2* Lamps Not Included *For 1x4 Add -12 after lamping to designate size. 32 48 in. T832 28 46 in. T5 54 46 in. T5HO Size 12 1x4 E120 Electronic, 120V E277 Electronic, 277V MV Electronic, Multivolt (120-277) H120 [2] Electronic, 120V, Hi-Lume H277 [2] Electronic, 277V, Hi-Lume HMV [2] Electronic, Multivolt, Hi-Lume G120 [3] Line Dimming, 120 Volt G277 [3] Line Dimming, 277 Volt GMV [3] Line or 0-10V dimming, Multivolt PMV* Electronic Program Start Notes Basket Style PF Perforated Basket RL Linear Ribbed Lens [2] HiLume and multivolt dimming ballasts available for T8 lamps only. [3] Dimming ballasts available for T8 & T5HO lamps only. *Electronic Ballast, 10% THO, Program Start. WP WP10 EM EM14 Options [1] 6ft whip, 3/18ga 6ft whip, 4/18ga Emergency ballast Emergency ballast, 1400Lumen EM14 ballast required for T5, TT5 & T5HO lamps
RDI 1x4 ft. DIMENSIONS SIDE VIEW 47 15/16 in. 47 3/4 in. BACK VIEW 2-7/8 in. K.O. ACCESS PLATE PHOTOMETRIC REFERENCE Lamping: 1 Lamp 28W T5 LER: 74.2 lpw
RDI 1x4 ft. Lamping: 2 Lamp 28W T5 LER: 69.1 lpw
FEATURES & SPECIFICATIONS INTENDED USE Specification grade, direct / indirect center diffuser luminaire provides smooth and uniform ambient lighting for all commercial and industrial buildings with recessed configurations. Reflected light from matte surfaces provide a softened sky light appearance to the modern office environment. SIZE W x L x H in inches (mm) 23.75W x 24.0L x 5.5Dp (600 x 610 x 140) LAMP 2 or 3 lamp positions MATERIALS & FEATURES Housing is die-formed and embossed code 22 gage steel. Luminaire body finish is high reflectance baked white enamel, with matte white reflectors. Wiring knockouts are provided on the back of housing. Center diffuser snaps into place; no tools are required for removal. Diffuser is perforated to maintain even brightness, and provided with an internal, acrylic overlay to obscure lamps. Direct / indirect mimics sky light appearance Matte white reflective surfaces for soft, uniform light distribution Recessed perforated center diffuser with acrylic overlay. RDI 2x2 ft. MOUNTING Recessed inverted T-Bar ceilings. Grid mount. LISTING Fixture and Ballast: UL Listed. Ballast: Thermally protected, class P, HPF, Non PCB. TYPICAL OPTIONS AND ACCESSORIES Emergency ballasts, whips, and lenses. See options page at the end of the T02Grid section, or contact factory for more details. ORDERING INFORMATION Example: RDI214E120 RDI 2 14 E120 Series RDI Direct/Indirect, Center basket, Grid mount Lamp Position 2 or 3 Lamps Not Included Lamp Type [1] 17 24 in. T8 14 22 in. T5 24 22 in. T5HO 40BX Biaxial (TT5) 2G11 4 Pin Ballast & Voltage [1] E120 Electronic, 120V E277 Electronic, 277V MV Electronic, Multivolt (120-277) H120 [2] Electronic, 120V, Hi-Lume H277 [2] Electronic, 277V, Hi-Lume HMV [2] Electronic, Multivolt, Hi-Lume G120 [3] Line Dimming, 120 Volt G277 [3] Line Dimming, 277 Volt GMV [3] Line or 0-10V dimming, Multivolt WP WP10 EM EM14 Options [1] 6ft whip, 3/18ga 6ft whip, 4/18ga Emergency ballast Emergency ballast, 1400Lumen EM14 ballast required for T5, TT5 & T5HO lamps Notes [1] See end of T02Grid for many additional lamps, ballasts, finishes, and options. [2] HiLume and multivolt dimming ballasts available for T8 lamps only. [3] Dimming ballasts available for T8 lamps only.
RDI 2x2 ft. DIMENSIONS All dimensions are inches. Specifications subject to change without notice. 5.50 in. 24.0 in. 23.82 in. 23.25 in. Access Plate on Center 1/2 Nom. EKO PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Lamp configurations shown are typical. Photometric data on these and other configurations available upon request. RCR Zonal cavity coefficients RDI 317 Spacing ratio. Along 1.2 Across 1.9 0 0.71 0.70 0.70 0.69 0.69 0.68 0.66 0.66 0.65 1 0.65 0.61 0.59 0.63 0.60 0.58 0.58 0.56 0.54 2 0.59 0.54 0.49 0.57 0.52 0.49 0.50 0.47 0.44 3 0.54 0.47 0.42 0.52 0.46 0.41 0.44 0.40 0.37 4 0.49 0.42 0.36 0.48 0.41 0.36 0.39 0.35 0.32 5 0.45 0.37 0.32 0.44 0.36 0.31 0.35 0.31 0.27 6 0.42 0.33 0.28 0.40 0.33 0.28 0.32 0.27 0.24 7 0.39 0.30 0.25 0.38 0.30 0.25 0.39 0.24 0.21 8 0.36 0.28 0.23 0.35 0.27 0.22 0.36 0.22 0.19 9 0.34 0.25 0.20 0.33 0.25 0.20 0.24 0.20 0.17 10 0.32 0.23 0.19 0.31 0.23 0.18 0.22 0.18 0.15 RCR Zonal cavity coefficients RDI 240BX. Spacing ratio. Along 1.2 Across 1.9 0 0.78 0.77 0.77 0.76 0.76 0.75 0.72 0.72 0.72 1 0.71 0.68 0.64 0.69 0.66 0.63 0.63 0.61 0.59 2 0.65 0.59 0.54 0.63 0.58 0.53 0.55 0.52 0.49 3 0.59 0.52 0.46 0.57 0.51 0.45 0.49 0.44 0.41 4 0.54 0.46 0.40 0.53 0.45 0.39 0.43 0.38 0.35 5 0.50 0.41 0.35 0.48 0.40 0.34 0.39 0.34 0.30 6 0.46 0.36 0.30 0.44 0.36 0.30 0.35 0.30 0.26 7 0.42 0.33 0.27 0.41 0.33 0.27 0.32 0.27 0.23 8 0.40 0.30 0.25 0.39 0.30 0.24 0.29 0.24 0.21 9 0.37 0.28 0.22 0.36 0.27 0.22 0.27 0.22 0.19 10 0.35 0.26 0.20 0.34 0.25 0.20 0.25 0.20 0.17 RCR Zonal cavity coefficients RDI 224 Spacing ratio. Along 1.2 Across 1.9 0 0.81 0.80 0.80 0.79 0.79 0.78 0.75 0.75 0.75 1 0.74 0.71 0.67 0.72 0.69 0.66 0.66 0.64 0.62 2 0.68 0.62 0.57 0.66 0.60 0.56 0.58 0.54 0.51 3 0.62 0.54 0.48 0.60 0.53 0.48 0.51 0.47 0.43 4 0.57 0.48 0.43 0.55 0.47 0.42 0.46 0.41 0.37 5 0.52 0.43 0.37 0.51 0.42 0.36 0.41 0.36 0.32 6 0.48 0.38 0.32 0.47 0.38 0.32 0.37 0.31 0.28 7 0.45 0.35 0.29 0.43 0.34 0.29 0.33 0.28 0.24 8 0.42 0.32 0.26 0.40 0.32 0.26 0.31 0.26 0.22 9 0.39 0.29 0.24 0.38 0.29 0.23 0.28 0.23 0.20 10 0.36 0.27 0.22 0.35 0.27 0.21 0.26 0.21 0.18 RCR Zonal cavity coefficients RDI 340BX Spacing ratio. Along 1.2 Across 1.9 0 0.70 0.70 0.69 0.68 0.68 0.68 0.65 0.65 0.64 1 0.64 0.61 0.58 0.62 0.59 0.57 0.57 0.55 0.53 2 0.58 0.53 0.49 0.56 0.52 0.48 0.50 0.46 0.44 3 0.53 0.46 0.41 0.51 0.45 0.41 0.44 0.40 0.36 4 0.49 0.41 0.36 0.47 0.40 0.35 0.39 0.35 0.31 5 0.45 0.37 0.31 0.43 0.36 0.31 0.35 0.30 0.27 6 0.41 0.33 0.27 0.40 0.32 0.27 0.31 0.27 0.23 7 0.38 0.30 0.25 0.37 0.29 0.24 0.28 0.24 0.21 8 0.36 0.27 0.22 0.35 0.27 0.22 0.26 0.22 0.19 9 0.33 0.25 0.20 0.32 0.25 0.20 0.24 0.20 0.17 10 0.31 0.23 0.18 0.30 0.23 0.18 0.22 0.18 0.15
FEATURES & SPECIFICATIONS INTENDED USE Specification grade, direct / indirect center diffuser luminaire provides smooth and uniform ambient lighting for all commercial and industrial buildings with recessed configurations. Reflected light from matte surfaces provide a softened sky light appearance to the modern office environment. RDI 2x4 ft. SIZE W x L x H in inches (mm) 23.75W x 48.0L x 5.5Dp (600 x 1220 x 140) LAMP 2 or 3 lamp positions. MOUNTING Recessed inverted T-Bar ceilings. Grid mount. MATERIALS & FEATURES Housing is die-formed and embossed code 22 gage steel. Luminaire body finish is high reflectance baked white enamel, with matte white reflectors. Wiring knockouts are provided on the back of housing. Center diffuser snaps into place; no tools are required for removal. Diffuser is perforated to maintain even brightness, and provided with an internal, acrylic overlay to obscure lamps. Direct / indirect mimics sky light appearance Matte white reflective surfaces for soft, uniform light distribution Recessed perforated center diffuser with acrylic overlay. LISTING Fixture and Ballast: UL Listed. Ballast: Thermally protected, class P, HPF, Non PCB. TYPICAL OPTIONS AND ACCESSORIES Emergency ballasts, whips, and lenses. See options page at the end of the T02Grid section, or contact factory for more details. ORDERING INFORMATION Example: RDI 3 32 E120 RDI 3 32 E120 Series RDI Direct/Indirect, Center basket, Grid mount Lamp Positions 2 or 3 Lamps Not Included Lamp Type [1] 32 48 in. T8 28 26 in. T5 54 46 in. T5HO Ballast & Voltage [1] E120 Electronic, 120V E277 Electronic, 277V MV Electronic, Multivolt (120-277) H120 [2] Electronic, 120V, Hi-Lume H277 [2] Electronic, 277V, Hi-Lume HMV [2] Electronic, Multivolt, Hi-Lume G120 [3] Line Dimming, 120 Volt G277 [3] Line Dimming, 277 Volt GMV [3] Line or 0-10V dimming, Multivolt WP WP10 EM EM14 Options [1] 6ft whip, 3/18ga 6ft whip, 4/18ga Emergency ballast Emergency ballast, 1400Lumen Notes [1] See end of T02Grid for many additional lamps, ballasts, finishes, and options. [2] HiLume and multivolt dimming ballasts available for T8 lamps only. [3] Dimming ballasts available for T8 & T5HO lamps only. EM14 ballast required for T5, TT5 & T5HO lamps
RDI 2x4 ft. DIMENSIONS All dimensions are inches. Specifications subject to change without notice. 5.50 in. 48.0 in. 23.82 in. 23.25 in. Access Plate on Center 1/2 Nom. EKO PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Lamp configurations shown are typical. Photometric data on these and other configurations available upon request. RCR Zonal cavity coefficients RDI 232 Spacing ratio. Along 1.2 Across 1.9 0 0.77 0.76 0.76 0.75 0.75 0.74 0.72 0.71 0.71 1 0.70 0.66 0.63 0.68 0.65 0.62 0.62 0.60 0.58 2 0.64 0.58 0.53 0.62 0.56 0.52 0.54 0.50 0.47 3 0.58 0.50 0.45 0.56 0.49 0.44 0.47 0.43 0.39 4 0.53 0.45 0.39 0.51 0.44 0.38 0.42 0.37 0.33 5 0.49 0.40 0.33 0.47 0.39 0.33 0.37 0.32 0.29 6 0.45 0.35 0.29 0.43 0.35 0.29 0.34 0.29 0.25 7 0.41 0.32 0.26 0.40 0.32 0.26 0.31 0.26 0.22 8 0.39 0.29 0.24 0.38 0.29 0.23 0.28 0.23 0.20 9 0.36 0.27 0.21 0.35 0.26 0.21 0.26 0.21 0.18 10 0.34 0.25 0.19 0.33 0.24 0.19 0.24 0.19 0.16 RCR Zonal cavity coefficients RDI 254 Spacing ratio. Along 1.2 Across 1.9 0 0.89 0.88 0.88 0.87 0.86 0.86 0.82 0.83 0.83 1 0.81 0.77 0.74 0.79 0.76 0.72 0.72 0.70 0.67 2 0.74 0.67 0.62 0.72 0.66 0.61 0.63 0.59 0.56 3 0.67 0.59 0.53 0.65 0.58 0.52 0.56 0.51 0.47 4 0.62 0.52 0.46 0.60 0.51 0.45 0.50 0.44 0.40 5 0.57 0.47 0.40 0.55 0.46 0.39 0.44 0.39 0.34 6 0.52 0.42 0.35 0.51 0.41 0.35 0.40 0.34 0.30 7 0.49 0.38 0.31 0.47 0.37 0.31 0.36 0.31 0.26 8 0.45 0.35 0.28 0.44 0.34 0.28 0.33 0.28 0.24 9 0.42 0.32 0.26 0.41 0.31 0.25 0.31 0.25 0.21 10 0.40 0.29 0.23 0.39 0.29 0.23 0.28 0.23 0.19 RCR Zonal cavity coefficients RDI 332 Spacing ratio. Along 1.2 Across 1.9 0 0.68 0.68 0.67 0.66 0.66 0.66 0.63 0.63 0.62 1 0.62 0.56 0.56 0.60 0.57 0.55 0.55 0.53 0.51 2 0.56 0.51 0.47 0.54 0.50 0.46 0.48 0.45 0.42 3 0.51 0.44 0.39 0.49 0.43 0.39 0.42 0.38 0.35 4 0.47 0.39 0.34 0.45 0.39 0.34 0.37 0.33 0.29 5 0.43 0.35 0.30 0.42 0.34 0.29 0.33 0.29 0.25 6 0.39 0.31 0.26 0.38 0.31 0.26 0.30 0.25 0.22 7 0.37 0.28 0.23 0.36 0.28 0.23 0.27 0.23 0.19 8 0.34 0.26 0.21 0.33 0.25 0.21 0.25 0.20 0.17 9 0.32 0.24 0.19 0.31 0.23 0.19 0.23 0.18 0.16 10 0.30 0.22 0.17 0.29 0.21 0.17 0.21 0.17 0.14 RCR Zonal cavity coefficients RDI 354 Spacing ratio. Along 1.2 Across 1.9 0 0.84 0.83 0.82 0.82 0.81 0.81 0.78 0.77 0.77 1 0.76 0.73 0.69 0.74 0.71 0.68 0.68 0.66 0.63 2 0.70 0.63 0.58 0.68 0.62 0.57 0.60 0.56 0.52 3 0.63 0.55 0.50 0.62 0.54 0.49 0.52 0.48 0.44 4 0.58 0.49 0.43 0.57 0.48 0.42 0.47 0.41 0.37 5 0.53 0.44 0.37 0.52 0.43 0.37 0.42 0.36 0.32 6 0.49 0.39 0.33 0.48 0.39 0.33 0.37 0.32 0.28 7 0.46 0.36 0.29 0.44 0.35 0.29 0.34 0.29 0.25 8 0.43 0.33 0.27 0.42 0.32 0.26 0.31 0.26 0.22 9 0.40 0.30 0.24 0.39 0.30 0.24 0.29 0.24 0.20 10 0.37 0.28 0.22 0.36 0.27 0.22 0.26 0.22 0.18