Y800 Plus Digital Panel Meter for Process, Strain & Potentiometer Follower Signals

Similar documents
Contents. Document information

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

NC-12 Modbus Application

Experiment 5. Strain Gage Measurements

PIEZOMETER AIRFLOW MEASURING RING

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

1.44 kw Programmable DC Power Supplies XLN Series

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PRODUCT PROFILE FEATURES

DPI 260 SERIES: Digital Pressure Indicators

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Application/Connection Examples

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Temperature & Humidity SMS Alert Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

Centro-Matic Automatic Lubrication Systems System Controls

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Digital Pressure Measuring Instrument MDR480

Digital and Analog I/O

Measuring Temperature withthermistors a Tutorial David Potter

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Duct Humidity Transmitter

WEB log. Device connection plans

High Power Programmable DC Power Supplies PVS Series

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Telefon (+45) Telefax (+45) Installation and operating manual

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Wahl C50 Calibrator FEATURES

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

DCS Series 1 kw, 1.2 kw, & 3 kw

WEB log. Device connection plans

Loop Calibration and Maintenance

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

How To Use A Ds340 (Dsp)

Modular I/O System Analog and Digital Interface Modules

Rackmount Intelligent Pressure Scanners

1 Serial RS232 to Ethernet Adapter Installation Guide

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Multi-Range Programmable DC Power Supplies 9115 Series

40.3. Control Relays and Timers

AIS750 Series Alarm Annunciator

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Multi-Range Programmable DC Power Supplies 9115 Series

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Transmitter Interface Program

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

DC Electronic Loads 8500 series

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

IntesisBox KNX Modbus TCP master

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

EMBEDDED ACCESS CONTROL Hardware Installation Guide

TAC I/NETTM MR-AHU-HP. Application Specific Controller

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Physical Specifications (Custom design available.)

SOUND LEVEL METER 94405

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

EDI Distributor Control Interface Wiring and Setup Instructions

LOXONE 12 Channel Amplifier

Unidirectional Transmitter/ Receiver Units Introduction

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

O C M III. Open Channel Flow Monitor

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Subminiature Load Cell Model 8417

Model SRMD Setra Remote Monitoring Display

Electronic Control Devices The European Product Catalogue 2007

WEATHER STATION FOR SOLAR FARM MONITORING

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

FREQUENCY RESPONSE ANALYZERS

Temperature Transmitters ZTT series

PCS0100en Persy Control Services B.V. Netherlands

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

MLC TM Maximum Productivity and Versatility for Control without Compromise!

NEW. EVEN MORE data acquisition and test stand automation

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Product Information Sheet UH28CS-12kV Hi Pot Tester

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

1. SAFETY INFORMATION

Quick Connect. quick - simple - efficient.

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Transcription:

Features Y800 Plus Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200 ma and ±5A dc current ranges All ranges factory calibrated 99.99% full scale accuracy Scalable to ±99,999 for display in engineering units Up to 60 conversions per second Peak or valley capture & display Universal AC power: 85-264 Vac Built-in isolated excitation supply: 5, 10 or 24 Vdc Ratiometric compensation for variations in excitation voltage 1/8 DIN case sealed to NEMA-4X from front panel Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay output: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac Description Y800 Plus digital process and strain panel meters are a costeffective solution to monitoring and control applications which require zero and span adjustment for process signals such as 4-20 ma, 0-5 V, 0-10 V, or strain gauges. The meters are also suitable for potentiometer follower applications, where the transducer output is a changing resistance. The display is scalable to five digits from -99,999 to +99,999 from the front panel to read directly in engineering units, such as PSI. Three scaling methods are selectable: scale and offset, two-point method, and system-level calibration using actual transducer signals. All ranges are precalibrated at the factory, so that recalibration is not needed when changing ranges or signal conditioners. Strain gauges with a 20 mv output can be scaled to display up to 10,000 counts with a 4-wire ratiometric connection, while 200 mv outputs of can be scaled to display up to 99,999 counts. For higher sensitivity, 20 mv signals can be scaled to 99,999 counts with a 4- or 6-wire connection using the Y800 Plus load cell meter. A high input impedance of 1 Gohm is provided on 200.00 mv and 2.000 V ranges to minimize the load on the voltage signal. An isolated 5, 10 or 24 Vdc isolated excitation output is standard to power external transducers and transmitters. Up to 120 ma is provided at 10V to power four 350 ohm load cells in parallel. When powering strain gauges, load cells or potentiometers, the excitation output is monitored by the meter to eliminate errors due to voltage variations. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or a control signal at the rear connector, or be transmitted as serial data. Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time constant to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Y800 Plus meters may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

Specifications DC Voltage DC Voltage Range Resolution Input Resistance Error at 25 C ±200.00 mv ±2.000 V ±20.000 V ±200.00 V ±600.0 V * ±300.0 V * 600.0 V range is not ETL certified. DC Current 10 µv 100 µv 1 mv 10 mv 100 mv 100 mv 1 GΩ 1 GΩ ± 0.4 V ± 0.4 V DC Current Range Resolution Input Resistance Error at 25 C ±2.0000 ma ±20.000 ma ±200.00 ma ±5.000 A 0.1 µa 1.0 µa 10 µa 1.0 ma 100 Ω 10 Ω 1 Ω 0.01 Ω ± 10 ma Display Readout Range Indicators 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. -99999 to 99999 or -99990 to 99990 (count by 10) Minus sign, 2 red LED lamps A-to-D Conversion Technique A-to-D rate Output update rate Display update rate Concurrent Slope (Pat 5,262,780) 60/s at 60 Hz, 50/s at 50 Hz 56/s at 60 Hz, 47/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz Accuracy Error at 25 C Span tempco Zero tempco 0.01% FS ± 2 counts (except 5A range) 0.003% of reading/ C 0.1 count/ C Noise Rejection CMR, DC to 60 Hz NMR at 50/60 Hz 130 db 90 db with min filtering Maximum Signal Max applied voltage Current protection 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges 25x for 2 ma, 8x for 20 ma, 2.5x for 200 ma, 1x for 5 A Power Voltage, standard Voltage, optional Frequency Power Isolation 85-264 Vac or 90-300 Vdc (DC operation is not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz Excitation Output (standard) Selectable levels Output isolation 5 Vdc ± 5%, 100 ma; 10 Vdc ± 5%, 120 ma; 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output levels Current compliance Voltage compliance Scaling Resolution 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (jumper selectable) 2 ma at 10V ( > 5 kω load) 12V at 20 ma (< 60Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale)

Isolation Relay Outputs (optional) Relay types Current ratings Output common Isolation 2 Form C contact relays or 4 Form A contact relays (normally open) 2 or 4 Form A, AC/DC solid state relays (normally open) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays Serial Data I/O (optional) Board selections Protocols Data rates Digital addresses Isolation Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Custom ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Custom ASCII) Signal Connections Environmental Operating temperature Storage temperature Relative humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Mechanical Application Examples

Potentiometer Application In potentiometric (or potentiometer follower) applications, the signal from a sliding contact voltage divider can be converted to engineering units such as position, level or percentage. By operating in a ratiometric mode, the meter will remove any effects caused by variations in the excitation supply. For use with a 1 kohm potentiometer, the recommended applied excitation voltage is 10 V, and a 2 kohm resistor should be placed in series with the excitation output and excitation return leads. This will allow the meter's 2.0000 V scale with a high input impedance of 1 Gohm to be used. Powering two-wire transmitters The isolated 24 Vdc, 50 ma excitation output, which is standard with all Y800 Plus meters, is ideal for powering two-wire, 4-20 ma transmitters. The same two wires are used to apply voltage and carry the output current. Inside the meter, the 4-20 ma current is dropped across a 10 ohm resistor and sets up a 40-200 mv voltage, which is then sensed by the meter and scaled to engineering units. Testing with peak detection Destructive testing is an ideal application for the Y800 Plus strain meter. Peak readings are automatically captured at rates up to 60 per second, while the display updates at a legible 3.5 readings per second. The peak reading can be recalled at the push of a button or be transmitted via RS-232 or RS-485. The meter provides isolated 10 Vdc power for up to four (4) the strain gauges and can be scaled to read out directly in engineering units from -99,999 to +99,999. Custom curve linearization The Y800 Plus DC meter with the Extended main board option allows exceptionally accurate custom curve linearization. For setup, up to 180 data points can be entered into a spreadsheet. The system then creates multiple non-linear spline-fit segments, which provide much better accuracy than linear segments. Illustrated, is the readout of volume of irregularly shaped tanks based on measured liquid level or pressure. Altimeters and thermistors are further applications. Rate from successive readings The Extended computer board allows the display of rate based on successive readings, for instance flow rate based on changes in liquid level or static pressure in a tank. In the above illustration, the meter displays the rate in gallons at which a horizontal tank is being emptied. The input to the meter can be nonlinear, since only the linearized readings are compared for the determination of rate.

Ordering Guide Create a model a model number in this format: Y810000P, IPC DPM Type Main Board Y8 Y800 Plus Digital Panel Meter 1 Standard Main Board, Green LEDs 2 Standard Main Board, Red LEDs 3 Extended Main Board, Green LEDs 4 Extended Main Board, Red LEDs Note: Extended capability is required for custom curve linearization or for display of time rate of change, such as flow rate from changing tank level or acceleration from changing speed. Power Relay Output Analog Output Digital Interface Signal Input 0 85-264 Vac 1 12-32 Vac & 10-48 Vdc. 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 1 RS232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter Process Signals (e.g., 4-20 ma, 0-5 V) P Field scalable. Default Scaling is 4-20 ma = 0-100.00 P1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. Strain Gage, Potentiometer Follower (4-wire ratio) SG Field Scalable. Default Scaling is 0-200 mv = 0-100.00 SG1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. Note: The same DC signal conditioner board can be user-configured for process, strain, potentiometer follower, DC Volts and DC Amps. It is precalibrated in EEPROM for all Y800 Plus DC Volt and DC Amp ranges. Add-on Options BL Blank Lens without Button Pads CBL01 RJ11-to-DB9 Cable CBL02 USB-to-DB9 Adapter CBL05 USB Cable, A to B IPC Splash-proof Cover BOX1 NEMA-4 Enclosure BOX2 NEMA-4 Enclosure plus IPC