Guide Specification: SOUNDSTOP Soundproofing Fiberboard Revision Date: May 2014

Similar documents
ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

GYPSUM AREA SEPARATION FIREWALLS GA

EcoTouch Insulation with PureFiber Technology

Underwriters Laboratories Testing Information

Fiberglas, Exterior Wall Thermal Insulation

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Guide Specifications for Maple Flooring Systems

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

eading Performance Solutions

Product Guide Specification

The Case for Cross Laminated Timber: Part 2

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CertainTeed. Shaftliner For A rea Separation Firewalls

H-Stud Area Separation Wall System

PART 1 GENERAL 1.1 SECTION INCLUDES

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Packaged Terminal Air Conditioner Wall Sleeve Installation

Division 9. SignaFlor Pad and Pour Flooring System

Gypsum Board Systems Manual

Asphalt Shingle Application Requirements

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

Lightweight Partition Design for Residential and Commercial Buildings

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Product Guide Specification

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Certification: Building Plans Examiner. Exam ID: B3

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Fire protection for townhouses that share a common wall. Area Separation Wall. Systems

Ducoterra Radiant Heating Panel Installation Manual

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

COMMERCIAL BUILDING APPLICATIONS

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

AUTHORIZATION TO MARK

MASTERFORMAT SPECIFICATION

GYPSUM BOARD AND PLASTER

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

FIRESTOPPING & SMOKE SEALS

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Mark Cramer Inspection Services, Inc.

Window Installation Instructions

Foundation. Foundation

GUIDELINE SPECIFICATIONS

GYPSUM BOARD Guide Specification. National Gypsum Company SECTION GYPSUM BOARD PART 1 - GENERAL 1.1 SECTION INCLUDES

CHAPTER 7: Building Systems ROOFING SYSTEMS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

SECTION METAL WALL PANELS

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

LP OSB Sheathing & Structural 1 Sheathing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

GreenGuard Housewrap Installation Guide

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Gold Bond BRAND. e2xp Tile Backer /NGC

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

CPA Steel Stud Framing Page 1 of 11

Rockwool Flexi Insulation Application Guide

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

application instructions

B. Related categories: The following categories contain requirements that relate to this section:

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Laminate Flooring T-Lock Angle-Drop Installation Instructions

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

2014 British Columbia Building Code Changes

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

SECTION PREFORMED METAL STANDING SEAM ROOFING

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

IMPACT DAMAGE RESISTANT WALL SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Preventing Ice Dams on Roofs

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Moisture Control. System Solutions to Prevent Mold

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

SECTION STANDING SEAM METAL ROOFING

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

Transcription:

Guide Specification: SOUNDSTOP Soundproofing Fiberboard Revision Date: May 2014 Section 09 81 13 Acoustic Board Insulation Specifier Notes: This guide specification is written according to the Construction Specifications Institute (CSI) MasterFormat 2004. The section must be carefully reviewed and edited by the architect or engineer to meet the requirements of the project. Coordinate this section with other specification sections and the drawings. Specifier Notes: SOUNDSTOP fiberboard is a high-quality, cost-effective solution to all sound deadening, soundproofing, or sound insulation needs. Meeting national codes and building standards, SOUNDSTOP is as versatile as it is effective, perfect in applications ranging from walls to ceilings to floors. SOUNDSTOP will exceed your expectations for a quality building product, unmatched in costeffectiveness and performance. SOUNDSTOP can be used in all homes and commercial buildings where noise and sound transmission from room to room needs to be eliminated. SOUNDSTOP takes shock or sound vibrations that travel through drywall and stops the movement of the sound or shock to the other side. SOUNDSTOP deadens sound transfer from shared walls, corridors, media rooms, workshops, laundries, etc. PART 1 GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of acoustic board insulation for walls, celings, and floor systems. 1.2 REFERENCES A. ASTM C 208-95 (2001) Standard Specification for Cellulosic Fiber Insulating Board. 1.3 SUBMITTALS A. Submit under provisions of Section 01 33 00. B. Product Data: Manufacturer's catalog data and installation instructions for all conditions. 1. All materials shall be manufactured by BLUE RIDGE FIBERBOARD, unless specified otherwise. 2. All materials shall be installed in accordance with printed installation instructions by BLUE RIDGE FIBERBOARD. C. Quality Assurance/Control Submittals: 1. Manufacturer's installation and safety data / instructions. 1.4 QUALITY ASSURANCE A. Manufacturer's Qualifications: 1. Minimum 50 years experience in producing fiber wall boards of the type specified herein. Project Name 8/6/2014 09 81 13-1 Acoustic Board Insulation

1.5 DELIVERY, STORAGE, AND HANDLING A. Deliver materials in manufacturer's original packages or bundles bearing the brand name of the product. 1. Inspect the materials upon delivery to assure that specified products have been received. 2. Report damaged material immediately to the delivering carrier and note such damage on the carrier's freight bill of lading. B. Storage and Handling 1. Store materials inside, level, under cover. 2. Keep dry; protect from weather and damage from construction operations and other causes. 3. Store at a location where humidity and temperature duplicates those during installation and occupancy in order to stabilize SOUNDSTOP. 1.6 PRECAUTIONS A. BLUE RIDGE FIBERBOARD products must not be used in close proximity to chimneys, heater units, fireplaces, steam pipes, or other surfaces which could provide long term exposure to excessive heat (maximum 212 F) without adequate thermal protection. B. Consult the appropriate heating appliance manufacturer s instructions before installation. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: BLUE RIDGE FIBERBOARD, 250 Celotex Dr., Danville, VA, 24541. B. Requests for substitutions will be considered in accordance with provisions of Section 01 25 00 Substitution Procedures. C. Provide all structural wall sheathing boards from a single manufacturer. 2.2 MATERIALS Specifier Note: Consult manufacturer for specific recommendations of tested assembly constructions and STC ratings. A. Sound-Deadening Boards: SOUNDSTOP physical properties as follows: 1. Panel size: 4 0 (1,200 mm) x 8 0 (2,400 mm) or 9 0 (2,700 mm) x ½ (13 mm). 2. Density: 17.5-18 pcf (288 kg/cubic m). 3. Thermal Conductivity (k) max.: 0.38. 4. Tensile Strength (parallel to surface): 150 psi (1,034 KPa). 5. Tensile Strength (perpendicular to surface): 600 psi (28.7 KPa). 6. Water Absorption by Volume, max percent; ASTM C209 (2-h test): a. 2 hour immersion: 7 % maximum. 7. Expansion, 50 to 90% relative humidity: 0.5%. 8. Vapor Permeance, grains/hr. ft 2. in. HG (mg/s. sq.m. KPa): 5 (287). 9. Flammability (per NFPA rating): 1 or slight. 10. R-Value: 1.3. 11. Sound Transmission Coefficient (STC): 44-51. Project Name 8/6/2014 09 81 13-2 Acoustic Board Insulation

2.3 ACCESSORIES 12. Impact Noise Rating and Impact Isolation Class (floors): INR 3-14 and IIC 37-44 (est.). 13. Moisture content by weight, max.: 10%. Specifier Notes: Installation accessories are dependent on substrates and installation methods as recommended by the manufacturer. SOUNDSTOP must be installed behind drywall or under floor sheathing: select from the following according to project requirements. A. Drywall: ½ minimum thickness. B. Nails: 11 ga, 1 ½ long galvanized roofing nails, as required to penetrate wood framing ¾ (19 mm) minimum. C. Screws: Metal framing, self-tapping 1 ¼ drywall type steel screw. PART 3 EXECUTION 3.1 EXAMINATION A. Examine substrates upon which work will be installed. B. Verify framing member spacing complies with manufacturer s requirements depending on substrates and installation methods for different sound ratings. C. Verify environmental conditions are, and will continue to be, maintained in accordance with manufacturer s recommendations. D. Coordinate with responsible entity to perform corrective work on unsatisfactory substrates or conditions. E. Starting work by installer is acceptance of substrate and environmental conditions. 3.2 PREPARATION A. Follow manufacturer s instructions. Store in a well-ventilated area. Material must be kept dry before installation. 1. Acoustic board insulation panels must be installed in a clean, dry condition. 2. Ensure panels are thoroughly dry prior to closing in the structure. 3. Provide proper ventilation and use of respiratory protection as required by the manufacturer. 4. Avoid dust inhalation. 5. Use caution when creating large amounts of dust because of potential explosion hazard. 6. Refer to manufacturer s MSDS data for these and other precautions. 3.3 INSTALLATION A. Contact BLUE RIDGE FIBERBOARD for full product installation guides and precautions. B. Allow a 1/8 gap between adjoining sheets, around openings, and where SOUNDSTOP meets ceilings, floors, and walls. Apply acoustical caulk in these gap areas, including the perimeter of all floor/ceiling/wall junctures and electrical openings. Project Name 8/6/2014 09 81 13-3 Acoustic Board Insulation

C. SOUNDSTOP requires 1. Wood wall framing at 16 or 24 O.C. maximum. 2. Metal wall framing at 16 or 24 O.C. maximum. D. Panel ends are required to align with framing members. E. See manufacturer s recommendations for required blocking. F. Verify that appropriate framing section or drawing notes comply. G. Panel Application: Install in accordance with manufacturer s instructions. 1. Wall systems: Apply SOUNDSTOP vertically to framing. Specifier Notes: Follow gypsum wallboard manufacturers installation recommendations or SOUNDSTOP manufacturer s recommendations for specific STC ratings. a. Wood framed systems: fasten with 11Ga, galvanized roofing nails 1 1/2 long at 12 O.C. around perimeter and intermediately. b. Metal framed systems: Attach to structurally sound metal stud using 1 1/4 corrosion resistant, self tapping drywall steel screws at 16 O.C. around perimeter and intermediately. c. Install gypsum wallboard or other panels so panel joints are staggered 16 (400 mm) and do not coincide with sound board joints. 2. Floor systems: Apply SOUNDSTOP at right angles to subfloor. Specifier Notes: Floor system should not be used under partitions due to compressibility of SOUNDSTOP material. a. Overlay with sleepers and underlayment. b. Fasten as required. 3. Ceiling System: Install ceiling system according to manufacturer s instructions for specific STC, IIC and INR ratings. a. Space wood ceiling floor joists at 16 O.C. b. Apply SOUNDSTOP board across framing. c. Fasten will required nails at 24 O.C. along perimeter and intermediately. d. Seal perimeter with acoustical caulk e. Apply gypsum wallboard over SOUNDSTOP at right angles and fasten with 1 ¾ GWB-54 annular ring nails, 7 O.C.. f.. Tape and cement joints. g. Seal electrical outlet openings with acoustical caulk. 3.4 ADJUSTING AND CLEANING A. Follow manufacturer's instructions for replacement of damaged panels. B. During the course of the work and on completion of the work, remove excess materials, Equipment, and debris and dispose of properly away from premises. Project Name 8/6/2014 09 81 13-4 Acoustic Board Insulation

C. Leave Work in clean condition in accordance with Section 01 50 00 Temporary Facilities and Controls. 3.5 PROTECTION A. After application of SOUNDSTOP sheathing, it is recommended that the final finish be applied as soon as practical. B. If applied SOUNDSTOP should get wet, wait until it is completely dry before application of drywall finish. END OF SECTION Project Name 8/6/2014 09 81 13-5 Acoustic Board Insulation